996 resultados para electrical heating elements
Resumo:
In this paper, a methodology for the integral energy performance characterization (thermal, daylighting and electrical behavior) of semi-transparent photovoltaic modules (STPV) under real operation conditions is presented. An outdoor testing facility to analyze simultaneously thermal, luminous and electrical performance of the devices has been designed, constructed and validated. The system, composed of three independent measurement subsystems, has been operated in Madrid with four prototypes of a-Si STPV modules, each one corresponding to a specific degree of transparency. The extensive experimental campaign, continued for a whole year rotating the modules under test, has validated the reliability of the testing facility under varying environmental conditions. The thermal analyses show that both the solar protection and insulating properties of the laminated prototypes are lower than those achieved by a reference glazing whose characteristics are in accordance with the Spanish Technical Building Code. Daylighting analysis shows that STPV elements have an important lighting energy saving potential that could be exploited through their integration with strategies focused to reduce illuminance values in sunny conditions. Finally, the electrical tests show that the degree of transparency is not the most determining factor that affects the conversion efficiency.
Resumo:
Within the building energy saving strategies, BIPV (building integrated photovoltaic systems) present a promising potential based on the close relationship existing between these multifunctional systems and the overall building energy balance. Building integration of STPV (semi-transparent photovoltaic) elements affects deeply the building energy demand since it influences the heating, cooling and lighting loads as well as the local electricity generation. This work analyses over different window-to-wall ratios the overall energy performance of five STPV elements, each element having a specific degree of transparency, in order to assess the energy saving potential compared to a conventional solar control glass compliant with the local technical standard. The prior optical characterization, focused to measure the spectral properties of the elements, was experimentally undertaken. The obtained data were used to perform simulations based on a reference office building using a package of specific software tools (DesignBuilder, EnergyPlus, PVsyst, and COMFEN) to take proper account of the STPV peculiarities. To evaluate the global energy performance of the STPV elements a new Energy Balance Index was formulated. The results show that for intermediate and large façade openings the energy saving potential provided by the STPV solutions ranges between 18% and 59% compared to the reference glass.
Resumo:
La presente tesis doctoral presenta una serie de estudios en el campo del patrimonio basados en metodologías de monitorización mediante redes de sensores y técnicas no invasivas con el objetivo de realizar nuevas aportaciones a la conservación preventiva mediante el seguimiento de los daños de deterioro o la prevención de los mismos. Las metodologías de monitorización mediante el despliegue de redes tridimensionales basadas en data loggers abordan estudios microclimáticos, de confort y energéticos a corto plazo, donde se establecen conclusiones relativas a la eficiencia energética de tres sistemas de calefacción muy utilizados en iglesias de la región centro de la Península Ibérica, abordando aspectos de afección de los mismos en el confort de los ocupantes o en el deterioro de los elementos patrimoniales o constructivos. Se desplegaron además distintas plataformas de redes de sensores inalámbricas procediendo a analizar en esta tesis cuál es la que presenta mejores resultados en el ámbito del patrimonio con el objetivo de una monitorización a largo plazo y considerando aspectos de comunicaciones, consumo y configuración de las redes. Una vez conocida la plataforma que presenta mejores resultados comparativos se muestra una metodología de estudio de la calidad de las comunicaciones en múltiples escenarios de patrimonio cultural y natural con la misma, que servirá para establecer una serie de aspectos a considerar en el despliegue de redes de sensores inalámbricas en futuros escenarios a monitorizar. Al igual que ocurre con las redes de sensores basadas en data loggers, las tareas de monitorización desarrolladas en esta tesis mediante el despliegue de las distintas plataformas inalámbricas ha permitido la detección de numerosos fenómenos de deterioro que son descritos a lo largo de la investigación y cuyo seguimiento supone una aportación a la prevención de daños en los distintos escenarios. Asimismo en el desarrollo de la tesis se realiza una aportación para la conservación preventiva mediante la monitorización con distintas técnicas no invasivas como la termografía infrarroja, las medidas de humedad superficial mediante protimeter, las técnicas de prospección de resistividad eléctrica de alta resolución o la prospección georradar. De este modo se desarrollan distintas aportaciones y conclusiones acerca de las ventajas y/o limitaciones de uso de las mismas analizando la idoneidad de aplicar cada una de ellas en distintas fases de análisis o con distintas capacidades de detección o caracterización de los daños. El estudio de imbricación de dichas técnicas ha sido desarrollado en un escenario real que presenta graves daños por humedad, habiendo sido posible la caracterización del origen de los mismos. ABSTRACT This doctoral dissertation discusses field research conducted to monitor heritage assets with sensor networks and other non-invasive techniques. The aim pursued was to contribute to conservation by tracking or preventing decay-induced damage. Monitoring methodologies based on three-dimensional data logger networks were used in short-term micro-climatic, comfort and energy studies to draw conclusions about the energy efficiency of three heating systems widely used in central Iberian churches. The impact of these systems on occupant comfort and decay of heritage or built elements was also explored. Different wireless sensor platforms were deployed and analysed to determine which delivered the best results in the context of long-term heritage monitoring from the standpoints of communications, energy demand and network architecture. A methodology was subsequently designed to study communication quality in a number of cultural and natural heritage scenarios and help establish the considerations to be borne in mind when deploying wireless sensor networks for heritage monitoring in future. As in data logger-based sensor networks, the monitoring conducted in this research with wireless platforms identified many instances of decay, described hereunder. Tracking those situations will help prevent damage in the respective scenarios. The research also contributes to preventive conservation based on non-invasive monitoring using techniques such as infrared thermography, protimeter-based surface damp measurements, high resolution electrical resistivity surveys and georadar analysis. The conclusions drawn address the advantages and drawbacks of each technique and its suitability for the various phases of analysis and capacity to detect or characterise damage. This dissertation also describes the intermeshed usage of these techniques that led to the identification of the origin of severe damp-induced damage in a real scenario.
Resumo:
La hipótesis que inspiró esta tesis sostiene que la integración de componentes fotovoltaicos en los cerramientos opacos y sombreamientos de huecos acristalados de edificios de oficinas en sitios ubicados en bajas latitudes, tomando como el ejemplo el caso concreto de Brasil, podría incrementar su eficiencia energética. Esta posibilidad se basa en el bloqueo de una parte significativa de la irradiación solar incidente en estos edificios, reduciendo así las cargas térmicas para la climatización y a la vez transformándola en energía eléctrica, a tal punto que se amortizan los costes de inversión en plazos aceptables a través de los ahorros en la demanda de energía. Para verificar esta hipótesis de partida se ha propuesto como objetivo general analizar la integración de elementos fotovoltaicos en cubiertas, muros opacos y sombreamiento de huecos acristalados desde la óptica del balance energético térmico y eléctrico. Inicialmente se presenta y analiza el estado del arte en los temas estudiados y la metodología de investigación, de carácter teórico basada en cálculos y simulaciones. A partir de un modelo tipo de edificio de oficinas situado en Brasil, se definen cuatro casos de estudio y una serie de parámetros, los cuales se analizan para siete latitudes ubicadas entre -1,4° y -30°, separadas las unas de las otras por aproximadamente 5°. Se presentan y discuten los resultados de más de 500 simulaciones para los siguientes conceptos: - recurso solar, desde la perspectiva de la disponibilidad de irradiación solar en distintas superficies de captación apropiadas para la integración de sistemas solares fotovoltaicos en edificaciones en bajas latitudes; - análisis de sombras, con objetivo de identificar los ángulos de sombras vertical (AVS) para protección de huecos acristalados en edificios de oficinas; - balance energético térmico, para identificar el efecto térmico del apantallamiento provocado por componentes fotovoltaicos en cubiertas, muros opacos y parasoles en ventanas en las cargas de refrigeración y consecuentemente en las demandas de energía eléctrica; - balance energético eléctrico, contrastando los resultados del balance térmico con la energía potencialmente generada en las envolventes arquitectónicas bajo estudio; - análisis económico, basado en un escenario de precios de la tecnología fotovoltaica de un mercado maduro y en la política de inyección a la red marcada por la actual normativa brasileña. Se han verificado los potenciales de ahorro económico que los sistemas activos fotovoltaicos podrían aportar, y asimismo se calculan diversos indicadores de rentabilidad financiera. En suma, esta investigación ha permitido extraer conclusiones que contribuyen al avance de la investigación y entender las condiciones que propician la viabilidad de la aplicación de componentes fotovoltaicas en las envolventes de edificios en Brasil, y hasta un cierto punto en otros países en latitudes equivalentes. ABSTRACT The hypothesis that inspired this thesis sustains that integration of photovoltaic components in the opaque envelope and shading elements of office buildings placed at low-latitude countries, using the specific case of Brazil, could increase its energy efficiency. This is possible because those components block a significant part of the incident solar irradiation, reducing its heating effect on the building and transforming its energy into electricity in such a way that the extra investments needed can be paid back in acceptable periods given the electricity bill savings they produce. In order to check this hypothesis, the main goal was to analyze the thermal and electrical performance of photovoltaic components integrated into roofs, opaque façades and window shadings. The first step is an introduction and discussion of the state of the art in the studied subjects, as well as the chosen methodology (which is theoretical), based on calculations and simulations. Starting from an office building located in Brazil, four case studies and their parameters are defined, and then analyzed, for seven cities located between latitudes -1.4° and -30°, with an approximate distance of 5° separating each one. Results of more than 500 simulations are presented and discussed for the following concepts: - Solar resource, from the perspective of irradiation availability on different surfaces for the integration of photovoltaic systems in buildings located at low latitudes; - Shading analysis, in order to determine the vertical shading angles (VSA) for protection of the glazed surfaces on office buildings; - Thermal energy balance, to identify the screening effect caused by photovoltaic components on roofs, opaque façades and window shadings on the cooling loads, and hence electricity demands; - Electric energy balance, comparing thermal energy balance with the energy potentially generated using the active skin of the buildings; - Economic analysis, based on a mature-market scenario and the current net metering rules established by the Brazilian government, to identify the potential savings these photovoltaic systems could deliver, as well as several indicators related to the return on the investment. In short, this research has led to conclusions that contribute to the further development of knowledge in this area and understanding of the conditions that favor the application of photovoltaic components in the envelope of office buildings in Brazil and, to a certain extent, in other countries at similar latitudes.
Resumo:
The temperature in a ferromagnetic nanostripe with a notch subject to Joule heating has been studied in detail. We first performed an experimental real-time calibration of the temperature versus time as a 100 ns current pulse was injected into a Permalloy nanostripe. This calibration was repeated for different pulse amplitudes and stripe dimensions and the set of experimental curves were fitted with a computer simulation using the Fourier thermal conduction equation. The best fit of these experimental curves was obtained by including the temperature-dependent behavior of the electrical resistivity of the Permalloy and of the thermal conductivity of thesubstrate(SiO2). Notably, a nonzero interface thermal resistance between the metallic nanostripe and thesubstrate was also necessary to fit the experimental curves. We found this parameter pivotal to understand ourresults and the results from previous works. The higher current density in the notch, together with the interface thermal resistance, allows a considerable increase of the temperature in the notch, creating a large horizontal thermal gradient. This gradient, together with the high temperature in the notch and the larger current density close to the edges of the notch, can be very influential in experiments studying the current assisted domain wall motion.
Resumo:
In the last decades, an increasing interest in the research field of wide bandgap semiconductors was observed, mostly due to the progressive approaching of silicon-based devices to their theoretical limits. 4H-SiC is an example among these, and is a mature compound for applications. The main advantages offered 4H-SiC in comparison with silicon are an higher breakdown field, an higher thermal conductivity, a higher operating temperature, very high hardness and melting point, biocompatibility, but also low switching losses in high frequencies applications and lower on-resistances in unipolar devices. Then, 4H-SiC power devices offer great performance improvement; moreover, they can work in hostile environments where silicon power devices cannot function. Ion implantation technology is a key process in the fabrication of almost all kinds of SiC devices, owing to the advantage of a spatially selective doping. This work is dedicated to the electrical investigation of several differently-processed 4H-SiC ion- implanted samples, mainly through Hall effect and space charge spectroscopy experiments. It was also developed the automatic control (Labview) of several experiments. In the work, the effectiveness of high temperature post-implant thermal treatments (up to 2000°C) were studied and compared considering: (i) different methods, (ii) different temperatures and (iii) different duration of the annealing process. Preliminary p + /n and Schottky junctions were also investigated as simple test devices. 1) Heavy doping by ion implantation of single off-axis 4H-SiC layers The electrical investigation is one of the most important characterization of ion-implanted samples, which must be submitted to mandatory post-implant thermal treatment in order to both (i) recover the lattice after ion bombardment, and (ii) address the implanted impurities into lattice sites so that they can effectively act as dopants. Electrical investigation can give fundamental information on the efficiency of the electrical impurity activation. To understand the results of the research it should be noted that: (a) To realize good ohmic contacts it is necessary to obtain spatially defined highly doped regions, which must have conductivity as low as possible. (b) It has been shown that the electrical activation efficiency and the electrical conductivity increase with the annealing temperature increasing. (c) To maximize the layer conductivity, temperatures around 1700°C are generally used and implantation density high till to 10 21 cm -3 . In this work, an original approach, different from (c), is explored by the using very high annealing temperature, around 2000°C, on samples of Al + -implant concentration of the order of 10 20 cm -3 . Several Al + -implanted 4H-SiC samples, resulting of p-type conductivity, were investigated, with a nominal density varying in the range of about 1-5∙10 20 cm -3 and subjected to two different high temperature thermal treatments. One annealing method uses a radiofrequency heated furnace till to 1950°C (Conventional Annealing, CA), the other exploits a microwave field, providing a fast heating rate up to 2000°C (Micro-Wave Annealing, MWA). In this contest, mainly ion implanted p-type samples were investigated, both off-axis and on-axis <0001> semi-insulating 4H-SiC. Concerning p-type off-axis samples, a high electrical activation of implanted Al (50-70%) and a compensation ratio below 10% were estimated. In the work, the main sample processing parameters have been varied, as the implant temperature, CA annealing duration, and heating/cooling rates, and the best values assessed. MWA method leads to higher hole density and lower mobility than CA in equivalent ion implanted layers, resulting in lower resistivity, probably related to the 50°C higher annealing temperature. An optimal duration of the CA treatment was estimated in about 12-13 minutes. A RT resistivity on the lowest reported in literature for this kind of samples, has been obtained. 2) Low resistivity data: variable range hopping Notwithstanding the heavy p-type doping levels, the carrier density remained less than the critical one required for a semiconductor to metal transition. However, the high carrier densities obtained was enough to trigger a low temperature impurity band (IB) conduction. In the heaviest doped samples, such a conduction mechanism persists till to RT, without significantly prejudice the mobility values. This feature can have an interesting technological fall, because it guarantee a nearly temperature- independent carrier density, it being not affected by freeze-out effects. The usual transport mechanism occurring in the IB conduction is the nearest neighbor hopping: such a regime is effectively consistent with the resistivity temperature behavior of the lowest doped samples. In the heavier doped samples, however, a trend of the resistivity data compatible with a variable range hopping (VRH) conduction has been pointed out, here highlighted for the first time in p-type 4H-SiC. Even more: in the heaviest doped samples, and in particular, in those annealed by MWA, the temperature dependence of the resistivity data is consistent with a reduced dimensionality (2D) of the VRH conduction. In these samples, TEM investigation pointed out faulted dislocation loops in the basal plane, whose average spacing along the c-axis is comparable with the optimal length of the hops in the VRH transport. This result suggested the assignment of such a peculiar behavior to a kind of spatial confinement into a plane of the carrier hops. 3) Test device the p + -n junction In the last part of the work, the electrical properties of 4H-SiC diodes were also studied. In this case, a heavy Al + ion implantation was realized on n-type epilayers, according to the technological process applied for final devices. Good rectification properties was shown from these preliminary devices in their current-voltage characteristics. Admittance spectroscopy and deep level transient spectroscopy measurements showed the presence of electrically active defects other than the dopants ones, induced in the active region of the diodes by ion implantation. A critical comparison with the literature of these defects was performed. Preliminary to such an investigation, it was assessed the experimental set up for the admittance spectroscopy and current-voltage investigation and the automatic control of these measurements.
Resumo:
O óxido de zinco é um material semicondutor que apresenta alta transparência óptica no espectro visível, alta energia de ligação de éxcitons e piezoeletricidade. Por suas propriedades, ele é utilizado na área de sensores, eletrodos transparentes e dispositivos optoeletrônicos. No entanto, sua utilização ainda é limitada pela dificuldade de obtenção de condutividade tipo p, cujo principal dopante é o nitrogênio, devido à assimetria de dopagem ocasionada por defeitos intrínsecos do material, dopagem em valências diferentes das esperadas e formação de níveis de aceitadores profundos na banda proibida. A aplicação em dispositivos piezoelétricos também exige alta resistividade e ótimas propriedades cristalinas. Muitos processos de deposição estabelecidos hoje ainda utilizam altas temperaturas, o que impede sua deposição sobre superfícies ou substratos sensíveis a altas temperaturas. O objetivo deste trabalho é desenvolver técnicas de deposição de filmes de ZnO, principalmente em baixas temperaturas ( 100°C), pelo método de magnetron sputtering de rádio frequência, para avaliar a influência dos gases de processo nas características estruturais, estequiométricas, elétricas e ópticas dos filmes. Para isso, foram obtidos filmes utilizando pressão total de argônio, e pressões parciais de argônio e oxigênio e argônio e nitrogênio, utilizando alvo cerâmico de óxido de zinco ou alvo metálico de zinco. Para alvo de ZnO, filmes com condutividade tipo n foram obtidos em ambiente de argônio, em condições que geraram deficiências de oxigênio. Filmes altamente resistivos foram obtidos com a utilização de pressão parcial de oxigênio no gás de processo, em condições que resultaram em filmes estequiométricos, inclusive com condutividade tipo p. Condutividade tipo p mais alta foi observada, apenas por ponta quente, para uma amostra obtida em argônio logo após a utilização de nitrogênio na câmara de processo, que provavelmente sofreu influência da dopagem não intencional do cobre, que foi identificado como um contaminante do processo devido à estrutura da câmara. Para alvo de Zn, observou-se a formação de nitreto de zinco, que demonstrou alta capacidade de oxidação em ambiente atmosférico, e portanto, transforma-se naturalmente ao longo do tempo ou por processos de oxidação térmica em ZnO dopado com nitrogênio. Filmes de ZnO produzidos a partir de nitreto de zinco foram os únicos dos testados que apresentaram fotoluminescência característica do ZnO, mesmo para processos onde não houve aquecimento intencional.
Resumo:
In this research, strain-sensing and damage-sensing functional properties of cement composites have been studied on a conventional reinforced concrete (RC) beam. Carbon nanofiber (CNFCC) and fiber (CFCC) cement composites were used as sensors on a 4 m long RC beam. Different casting conditions (in situ or attached), service location (under tension or compression) and electrical contacts (embedded or superficial) were compared. Both CNFCC and CFCC were suitable as strain sensors in reversible (elastic) sensing condition testing. CNFCC showed higher sensitivities (gage factor up to 191.8), while CFCC only reached gage factors values of 178.9 (tension) or 49.5 (compression). Furthermore, damage-sensing tests were run, increasing the applied load progressively up to the RC beam failure. In these conditions, CNFCC sensors were also strain sensitive, but no damage sensing mechanism was detected for the strain levels achieved during the tests. Hence, these cement composites could act as strain sensors, even for severe damaged structures near to their collapse.
Resumo:
This article shows the research carried out by the authors focused on how the shape of structural reinforced concrete elements treated with electrochemical chloride extraction can affect the efficiency of this process. Assuming the current use of different anode systems, the present study considers the comparison of results between conventional anodes based on Ti-RuO2 wire mesh and a cement-based anodic system such as a paste of graphite-cement. Reinforced concrete elements of a meter length were molded to serve as laboratory specimens, to closely represent authentic structural supports, with circular and rectangular sections. Results confirm almost equal performances for both types of anode systems when electrochemical chloride extraction is applied to isotropic structural elements. In the case of anisotropic ones, such as rectangular sections with no uniformly distributed rebar, differences in electrical flow density were detected during the treatment. Those differences were more extreme for Ti-RuO2 mesh anode system. This particular shape effect is evidenced by obtaining the efficiencies of electrochemical chloride extraction in different points of specimens.
Resumo:
This research studies the self-heating produced by the application of an electric current to conductive cement pastes with carbonaceous materials. The main parameters studied were: type and percentage of carbonaceous materials, effect of moisture, electrical resistance, power consumption, maximum temperature reached and its evolution and ice melting kinetics are the main parameters studied. A mathematical model is also proposed, which predicts that the degree of heating is adjustable with the applied voltage. Finally, the results have been applied to ensure that cementitious materials studied are feasible to control ice layers in transportation infrastructures.
Resumo:
"Contract No. AF33(616)-310 RDO No. R-112-110 SR-6f2"
Resumo:
"Credit is largely due to Frank D. Graham ... for the authorship of the Guides, and for the original sketches illustrating electrical principles and construction."--Pref. to no. 1.
Resumo:
A phased-array antenna with switched-beam elements used to combat interference in an indoor wireless communication system is described. The array uses I-bit phase shifters applied to its elements in order to point its main beam in a desired direction and internal switching of elements in order to form nulls towards interference. The array's capability of suppressing interference is verified by studying its radiation patterns and by performing interference-rejection experiments in an indoor multipath environment. (c) 2005 Wiley Periodicals, Inc.
Resumo:
The design, development, and testing of an X-band 137-element passive reflect away capable of incorporating active devices such as transistor amplifiers is presented. In order to avoid grating lobes in the radiation pattern, the interelement spacing is minimized using dual-feed aperture-coupled patch antenna elements. Far-field radiation pattern results are presented and compared with the predicted radiation patterns. (C) 1999 John Wiley & Sons, Inc.
Resumo:
The object of this thesis is to develop a method for calculating the losses developed in steel conductors of circular cross-section and at temperatures below 100oC, by the direct passage of a sinusoidally alternating current. Three cases are considered. 1. Isolated solid or tubular conductor. 2. Concentric arrangement of tube and solid return conductor. 3. Concentric arrangement of two tubes. These cases find applications in process temperature maintenance of pipelines, resistance heating of bars and design of bus-bars. The problems associated with the non-linearity of steel are examined. Resistance heating of bars and methods of surface heating of pipelines are briefly described. Magnetic-linear solutions based on Maxwell's equations are critically examined and conditions under which various formulae apply investigated. The conditions under which a tube is electrically equivalent to a solid conductor and to a semi-infinite plate are derived. Existing solutions for the calculation of losses in isolated steel conductors of circular cross-section are reviewed, evaluated and compared. Two methods of solution are developed for the three cases considered. The first is based on the magnetic-linear solutions and offers an alternative to the available methods which are not universal. The second solution extends the existing B/H step-function approximation method to small diameter conductors and to tubes in isolation or in a concentric arrangement. A comprehensive experimental investigation is presented for cases 1 and 2 above which confirms the validity of the proposed methods of solution. These are further supported by experimental results reported in the literature. Good agreement is obtained between measured and calculated loss values for surface field strengths beyond the linear part of the d.c. magnetisation characteristic. It is also shown that there is a difference in the electrical behaviour of a small diameter conductor or thin tube under resistance or induction heating conditions.