939 resultados para continuous wave (CW)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a novel concept to determine the velocity and the location information of multiple mobile agents using Doppler radar has been introduced. Also, an expression for the minimum number of inline sensors needed to guarantee this estimation for n number of mobile agents has been obtained. Current methods use the time derivative of the displacement of adjacent position measurements to find the velocities of agents. This method is error prone, particularly, if the agents are accelerating. In our approach we incorporate direction-of-arrival (DOA) radar which tracks the location and the velocity of each and every agent in each measurement step.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

3-alkylpyrrole to the fabric surface. Direct applications of a conductive paint to the textile surface eliminate the exposure of the substrate to damaging oxidizing agents which allow the coating of more sensitive and delicate substrates. All textiles produced are tested for abrasion resistance and conductivity. For alkyl polypyrrole coated fabrics, the optimum carbon chain lengths are between n=10 and n=14, which result in optimum values of conductivity and solubility. The darkness of the tone is inversely related to the surface resistivity of the resulting conductive fabric. Therefore, deep black coatings have low resistivity whereas light gray coatings on a white fabric surface have higher surface resistivity. Longer alkyl chains result in higher surface resistivity in fabrics. The conductive coating of poly(3-decanylpyrrole) on the textile surface has a better abrasion resistance compared to that of an unsubstituted polypyrrole coating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the location and velocity estimation problem involving multiple targets using the phase difference and frequency shift of the returned Doppler modulated signal. The minimal receiver configuration that addresses the data association and missing information problem is presented for the case of linear arrays. Non-linearly modeled Doppler radar measurements are used to obtain an accurate estimate of the target dynamics progressively in a linear framework utilizing a recently developed robust state estimation approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have observed ultraviolet upconversion fluorescence from the 4D3/2 and 2P3/2 levels of Nd3+ in fluoroindate glass under infrared pumping. It was found that the excitation of a large population in the 4F3/2 metastable level allows to achieve strong upconversion emissions at 354 and 382 nm. A simple rate equation model reproduces the temporal behavior of the upconverted emission and allows us to estimate the energy transfer rate among three Nd3+ ions participating in the process. © 1997 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This year marks the 20th anniversary of functional near-infrared spectroscopy and imaging (fNIRS/fNIRI). As the vast majority of commercial instruments developed until now are based on continuous wave technology, the aim of this publication is to review the current state of instrumentation and methodology of continuous wave fNIRI. For this purpose we provide an overview of the commercially available instruments and address instrumental aspects such as light sources, detectors and sensor arrangements. Methodological aspects, algorithms to calculate the concentrations of oxy- and deoxyhemoglobin and approaches for data analysis are also reviewed. From the single-location measurements of the early years, instrumentation has progressed to imaging initially in two dimensions (topography) and then three (tomography). The methods of analysis have also changed tremendously, from the simple modified Beer-Lambert law to sophisticated image reconstruction and data analysis methods used today. Due to these advances, fNIRI has become a modality that is widely used in neuroscience research and several manufacturers provide commercial instrumentation. It seems likely that fNIRI will become a clinical tool in the foreseeable future, which will enable diagnosis in single subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a derivation and, based on it, an extension of a model originally proposed by V.G. Niziev to describe continuous wave laser cutting of metals. Starting from a local energy balance and by incorporating heat removal through heat conduction to the bulk material, we find a differential equation for the cutting profile. This equation is solved numerically and yields, besides the cutting profiles, the maximum cutting speed, the absorptivity profiles, and other relevant quantities. Our main goal is to demonstrate the model’s capability to explain some of the experimentally observed differences between laser cutting at around 1 and 10 μm wavelengths. To compare our numerical results to experimental observations, we perform simulations for exactly the same material and laser beam parameters as those used in a recent comparative experimental study. Generally, we find good agreement between theoretical and experimental results and show that the main differences between laser cutting with 1- and 10-μm beams arise from the different absorptivity profiles and absorbed intensities. Especially the latter suggests that the energy transfer, and thus the laser cutting process, is more efficient in the case of laser cutting with 1-μm beams.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wavelength bistability between 1245nm and 1295nm is demonstrated in a multi-section quantum-dot laser, controlled via the reverse bias on the saturable absorber. Continuous-wave or mode-locked regimes are achieved (output power up to 25mW and 17mW). © OSA/CLEO 2011.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Generation of continuous wave radiation at terahertz (THz) frequencies from a heterodyne source based on quantum-dot (QD) semiconductor materials is reported. The source comprises an active region characterised by multiple alternating photoconductive and QD carrier trapping layers and is pumped by two infrared optical signals with slightly offset wavelengths, allowing photoconductive device switching at the signals? difference frequency ~1 THz.(C) 2012 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present modulation instability analysis including azimuthal perturbations of steady-state continuous wave (CW) propagation in multicore-fiber configurations with a central core. In systems with a central core, a steady CW evolution regime requires power-controlled phase matching, which offers interesting spatial-division applications. Our results have general applicability and are relevant to a range of physical and engineering systems, including high-power fiber lasers, optical transmission in multicore fiber, and systems of coupled nonlinear waveguides. © 2013 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microwave Doppler radar has received considerable attention as a non-contact form of measuring human respiration; in particular for long term monitoring. One of the main challenges in converting this into a viable application is to suppress or separate the artefacts and other interfering signals from the desired respiration signal using a less complex and practically feasible design for regular and potentially real time use. Existing systems either require complex experimental setups or multiple Doppler radar modules to achieve this. In this paper, we propose an approach based on EMD-ICA and approximate entropy ideas to systematically separate received Doppler shifted signal into distinct components and reconstruct the desired respiration pattern pertaining to respective physiological activity. Indeed this allows suppression of the undesirable artefacts and interference from other competing signals. Practical experiments confirmed comparable performance of the proposed method to the measurements obtained through chest straps which are widely used clinically for monitoring respiration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental trials of autogenous deep penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 5.0 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser output power, welding velocity and defocusing distance on the morphology, welding depth and width as well as quality of the welded seam were investigated. Results show that full keyhole welding is not formed on both K4.18 and 42CrMo side, simultaneously, due to the relatively low output power. Partial fusion is observed on the welded seam near 42CrMo side because of the large disparity of thermal-physical and high-temperature mechanical properties of these two materials. Tile rnicrohardness of the laser-welded joint was also examined and analyzed. It is suggested that applying negative defocusing in the range of Raylei length can increase the welding depth and improve tile coupling efficiency of the laser materials interaction. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of gamma-FeCr0.29Ni0.16C0.06 austenite solid solution dendrites as the dominant and very small amount of super-fine dispersed Ni3Al gamma' phase and Laves particles as well as MC needle-like carbides distributed in the interdendritic regions. Although the microhardness of the laser-welded seam was lower than that of the base metal, the strength of the joint was equal to that of the base metal and the fracture mechanism showed fine ductility. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文报导了采用半导体激光器泵浦的高效连续可调谐Yb:LYSO激光器的输出特性。LYSO晶体同时具有LSO晶体良好的激光性能和YSO晶体易于生长且成本低廉的优点,实验中我们采用5at%掺杂的Yb:LYSO晶体进行研究,获得了最大输出功率2.84W、输出波长1085nm、光-光转换效率54.5%的高效输出。并且得到了1030-1111nm,一共81nm的波长调谐范围,这是目前我们所知道的从Yb:LYSO激光器获得的最宽的调谐输出。