82 resultados para collimator


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to investigate to what extent it is possible to use the secondary collimator jaws to reduce the transmitted radiation through the multileaf collimator (MLC) during an intensity modulated radiation therapy (IMRT). A method is developed and introduced where the jaws follow the open window of the MLC dynamically (dJAW method). With the aid of three academic cases (Closed MLC, Sliding-gap, and Chair) and two clinical cases (prostate and head and neck) the feasibility of the dJAW method and the influence of this method on the applied dose distributions are investigated. For this purpose the treatment planning system Eclipse and the Research-Toolbox were used as well as measurements within a solid water phantom were performed. The transmitted radiation through the closed MLC leads to an inhomogeneous dose distribution. In this case, the measured dose within a plane perpendicular to the central axis differs up to 40% (referring to the maximum dose within this plane) for 6 and 15 MV. The calculated dose with Eclipse is clearly more homogeneous. For the Sliding-gap case this difference is still up to 9%. Among other things, these differences depend on the depth of the measurement within the solid water phantom and on the application method. In the Chair case, the dose in regions where no dose is desired is locally reduced by up to 50% using the dJAW method instead of the conventional method. The dose inside the chair-shaped region decreased up to 4% if the same number of monitor units (MU) as for the conventional method was applied. The undesired dose in the volume body minus the planning target volume in the clinical cases prostate and head and neck decreased up to 1.8% and 1.5%, while the number of the applied MU increased up to 3.1% and 2.8%, respectively. The new dJAW method has the potential to enhance the optimization of the conventional IMRT to a further step.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC source model (with target, primary collimator, and flattening filter photon subsources and an electron subsource) for 6- and 18-MV photon beams when the energy and radial distributions of initial electrons striking a linac target change. For this purpose, phase-space data (PSD) was calculated for various mean electron energies striking the target, various normally distributed electron energy spread, and various normally distributed electron radial intensity distributions. All PSD was analyzed in terms of energy, fluence, and energy fluence distributions, which were compared between the different parameter sets. The energy spread was found to have a negligible influence on the subsource distributions. The mean energy and radial intensity significantly changed the target subsource distribution shapes and intensities. For the primary collimator and flattening filter subsources, the distribution shapes of the fluence and energy fluence changed little for different mean electron energies striking the target, however, their relative intensity compared with the target subsource change, which can be accounted for by a scaling factor. This study indicates that adjustments to MC source models can likely be limited to adjusting the target subsource in conjunction with scaling the relative intensity and energy spectrum of the primary collimator, flattening filter, and electron subsources when the energy and radial distributions of the initial electron-beam change.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A major barrier to widespread clinical implementation of Monte Carlo dose calculation is the difficulty in characterizing the radiation source within a generalized source model. This work aims to develop a generalized three-component source model (target, primary collimator, flattening filter) for 6- and 18-MV photon beams that match full phase-space data (PSD). Subsource by subsource comparison of dose distributions, using either source PSD or the source model as input, allows accurate source characterization and has the potential to ease the commissioning procedure, since it is possible to obtain information about which subsource needs to be tuned. This source model is unique in that, compared to previous source models, it retains additional correlations among PS variables, which improves accuracy at nonstandard source-to-surface distances (SSDs). In our study, three-dimensional (3D) dose calculations were performed for SSDs ranging from 50 to 200 cm and for field sizes from 1 x 1 to 30 x 30 cm2 as well as a 10 x 10 cm2 field 5 cm off axis in each direction. The 3D dose distributions, using either full PSD or the source model as input, were compared in terms of dose-difference and distance-to-agreement. With this model, over 99% of the voxels agreed within +/-1% or 1 mm for the target, within 2% or 2 mm for the primary collimator, and within +/-2.5% or 2 mm for the flattening filter in all cases studied. For the dose distributions, 99% of the dose voxels agreed within 1% or 1 mm when the combined source model-including a charged particle source and the full PSD as input-was used. The accurate and general characterization of each photon source and knowledge of the subsource dose distributions should facilitate source model commissioning procedures by allowing scaling the histogram distributions representing the subsources to be tuned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Detailed knowledge of the characteristics of the radiation field shaped by a multileaf collimator (MLC) is essential in intensity modulated radiotherapy (IMRT). A previously developed multiple source model (MSM) for a 6 MV beam was extended to a 15 MV beam and supplemented with an accurate model of an 80-leaf dynamic MLC. Using the supplemented MSM and the MC code GEANT, lateral dose distributions were calculated in a water phantom and a portal water phantom. A field which is normally used for the validation of the step and shoot technique and a field from a realistic IMRT treatment plan delivered with dynamic MLC are investigated. To assess possible spectral changes caused by the modulation of beam intensity by an MLC, the energy spectra in five portal planes were calculated for moving slits of different widths. The extension of the MSM to 15 MV was validated by analysing energy fluences, depth doses and dose profiles. In addition, the MC-calculated primary energy spectrum was verified with an energy spectrum which was reconstructed from transmission measurements. MC-calculated dose profiles using the MSM for the step and shoot case and for the dynamic MLC case are in very good agreement with the measured data from film dosimetry. The investigation of a 13 cm wide field shows an increase in mean photon energy of up to 16% for the 0.25 cm slit compared to the open beam for 6 MV and of up to 6% for 15 MV, respectively. In conclusion, the MSM supplemented with the dynamic MLC has proven to be a powerful tool for investigational and benchmarking purposes or even for dose calculations in IMRT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Study of behavior and influence of a multileaf collimator (MLC) on dose calculation, verification, and portal energy spectra in the case of intensity-modulated fields obtained with a step-and-shoot or a dynamic technique. METHODS: The 80-leaf MLC for the Varian Clinac 2300 C/D was implemented in a previously developed Monte Carlo (MC) based multiple source model (MSM) for a 6 MV photon beam. Using this model and the MC program GEANT, dose distributions, energy fluence maps and energy spectra at different portal planes were calculated for three different MLC applications. RESULTS: The comparison of MC-calculated dose distributions in the phantom and portal plane, with those measured with films showed an agreement within 3% and 1.5 mm for all cases studied. The deviations mainly occur in the extremes of the intensity modulation. The MC method allows to investigate, among other aspects, dose components, energy fluence maps, tongue-and-groove effects and energy spectra at portal planes. CONCLUSION: The MSM together with the implementation of the MLC is appropriate for a number of investigations in intensity-modulated radiation therapy (IMRT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within ±1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). METHODS As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. RESULTS The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V95% increased from 90% to 96% and V107% decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. CONCLUSIONS MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). METHODS This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. RESULTS For 15 × 34, 5 × 5, and 2 × 2 cm(2) fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. CONCLUSIONS The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Doctoral Thesis entitled Contribution to the analysis, design and assessment of compact antenna test ranges at millimeter wavelengths aims to deepen the knowledge of a particular antenna measurement system: the compact range, operating in the frequency bands of millimeter wavelengths. The thesis has been developed at Radiation Group (GR), an antenna laboratory which belongs to the Signals, Systems and Radiocommunications department (SSR), from Technical University of Madrid (UPM). The Radiation Group owns an extensive experience on antenna measurements, running at present four facilities which operate in different configurations: Gregorian compact antenna test range, spherical near field, planar near field and semianechoic arch system. The research work performed in line with this thesis contributes the knowledge of the first measurement configuration at higher frequencies, beyond the microwaves region where Radiation Group features customer-level performance. To reach this high level purpose, a set of scientific tasks were sequentially carried out. Those are succinctly described in the subsequent paragraphs. A first step dealed with the State of Art review. The study of scientific literature dealed with the analysis of measurement practices in compact antenna test ranges in addition with the particularities of millimeter wavelength technologies. Joint study of both fields of knowledge converged, when this measurement facilities are of interest, in a series of technological challenges which become serious bottlenecks at different stages: analysis, design and assessment. Thirdly after the overview study, focus was set on Electromagnetic analysis algorithms. These formulations allow to approach certain electromagnetic features of interest, such as field distribution phase or stray signal analysis of particular structures when they interact with electromagnetic waves sources. Properly operated, a CATR facility features electromagnetic waves collimation optics which are large, in terms of wavelengths. Accordingly, the electromagnetic analysis tasks introduce an extense number of mathematic unknowns which grow with frequency, following different polynomic order laws depending on the used algorithmia. In particular, the optics configuration which was of our interest consisted on the reflection type serrated edge collimator. The analysis of these devices requires a flexible handling of almost arbitrary scattering geometries, becoming this flexibility the nucleus of the algorithmia’s ability to perform the subsequent design tasks. This thesis’ contribution to this field of knowledge consisted on reaching a formulation which was powerful at the same time when dealing with various analysis geometries and computationally speaking. Two algorithmia were developed. While based on the same principle of hybridization, they reached different order Physics performance at the cost of the computational efficiency. Inter-comparison of their CATR design capabilities was performed, reaching both qualitative as well as quantitative conclusions on their scope. In third place, interest was shifted from analysis - design tasks towards range assessment. Millimetre wavelengths imply strict mechanical tolerances and fine setup adjustment. In addition, the large number of unknowns issue already faced in the analysis stage appears as well in the on chamber field probing stage. Natural decrease of dynamic range available by semiconductor millimeter waves sources requires in addition larger integration times at each probing point. These peculiarities increase exponentially the difficulty of performing assessment processes in CATR facilities beyond microwaves. The bottleneck becomes so tight that it compromises the range characterization beyond a certain limit frequency which typically lies on the lowest segment of millimeter wavelength frequencies. However the value of range assessment moves, on the contrary, towards the highest segment. This thesis contributes this technological scenario developing quiet zone probing techniques which achieves substantial data reduction ratii. Collaterally, it increases the robustness of the results to noise, which is a virtual rise of the setup’s available dynamic range. In fourth place, the environmental sensitivity of millimeter wavelengths issue was approached. It is well known the drifts of electromagnetic experiments due to the dependance of the re sults with respect to the surrounding environment. This feature relegates many industrial practices of microwave frequencies to the experimental stage, at millimeter wavelengths. In particular, evolution of the atmosphere within acceptable conditioning bounds redounds in drift phenomena which completely mask the experimental results. The contribution of this thesis on this aspect consists on modeling electrically the indoor atmosphere existing in a CATR, as a function of environmental variables which affect the range’s performance. A simple model was developed, being able to handle high level phenomena, such as feed - probe phase drift as a function of low level magnitudes easy to be sampled: relative humidity and temperature. With this model, environmental compensation can be performed and chamber conditioning is automatically extended towards higher frequencies. Therefore, the purpose of this thesis is to go further into the knowledge of millimetre wavelengths involving compact antenna test ranges. This knowledge is dosified through the sequential stages of a CATR conception, form early low level electromagnetic analysis towards the assessment of an operative facility, stages for each one of which nowadays bottleneck phenomena exist and seriously compromise the antenna measurement practices at millimeter wavelengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CATR facilities are attractive antenna measurement facilities. Main reasons which contribute to this fact lie on its inherent reduced volume, on-the-fly measurements and the extension of both to a wide range of frequencies. However, these features rely on the assumption that the field collimation scheme is able to generate a plane wave distribution (quiet zone) where the AUT is to be placed and operated in RX mode. Unfortunately, electromagnetic theory states that this field distribution is not possible to be generated by a finite size scatterer operated as the collimator of a nonzero wavelength time-harmonic propagating field. This is the background of this paper, where two well-known electromagnetic field collimators will be discussed: the serrated edge reflector and the blended rolled edge reflector. To reach this purpose, electromagnetic hybrid analysis techniques developed at Technical University of Madrid will be applied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La óptica anidólica es una rama de la óptica cuyo desarrollo comenzó a mediados de la década de 1960. Este relativamente nuevo campo de la óptica se centra en la transferencia eficiente de la luz, algo necesario en muchas aplicaciones, entre las que destacamos los concentradores solares y los sistemas de iluminación. Las soluciones de la óptica clásica a los problemas de la transferencia de energía de la luz sólo son adecuadas cuando los rayos de luz son paraxiales. La condición paraxial no se cumple en la mayoría de las aplicaciones para concentración e iluminación. Esta tesis contiene varios diseños free-form (aquellos que no presentan ninguna simetría, ni de rotación ni lineal) cuyas aplicaciones van destinadas a estos dos campos. El término nonimaging viene del hecho de que estos sistemas ópticos no necesitan formar una imagen del objeto, aunque no formar la imagen no es una condición necesaria. Otra palabra que se utiliza a veces en lugar de nonimaging es la palabra anidólico, viene del griego "an+eidolon" y tiene el mismo significado. La mayoría de los sistemas ópticos diseñados para aplicaciones anidólicas no presentan ninguna simetría, es decir, son free-form (anamórficos). Los sistemas ópticos free-form están siendo especialmente relevantes durante los últimos años gracias al desarrollo de las herramientas para su fabricación como máquinas de moldeo por inyección y el mecanizado multieje. Sin embargo, solo recientemente se han desarrollado técnicas de diseño anidólicas capaces de cumplir con estos grados de libertad. En aplicaciones de iluminación el método SMS3D permite diseñar dos superficies free-form para controlar las fuentes de luz extensas. En los casos en que se requiere una elevada asimetría de la fuente, el objeto o las restricciones volumétricos, las superficies free-form permiten obtener soluciones de mayor eficiencia, o disponer de menos elementos en comparación con las soluciones de simetría de rotación, dado que las superficies free-form tienen más grados de libertad y pueden realizar múltiples funciones debido a su naturaleza anamórfica. Los concentradores anidólicos son muy adecuados para la captación de energía solar, ya que el objetivo no es la reproducción de una imagen exacta del sol, sino sencillamente la captura de su energía. En este momento, el campo de la concentración fotovoltaica (CPV) tiende hacia sistemas de alta concentración con el fin de compensar el gasto de las células solares multi-unión (MJ) utilizadas como receptores, reduciendo su área. El interés en el uso de células MJ radica en su alta eficiencia de conversión. Para obtener sistemas competitivos en aplicaciones terrestres se recurre a sistemas fotovoltaicos de alta concentración (HCPV), con factores de concentración geométrica por encima de 500x. Estos sistemas se componen de dos (o más) elementos ópticos (espejos y/o lentes). En los sistemas presentados a lo largo de este trabajo se presentan ejemplos de concentradores HCPV con elementos reflexivos como etapa primaria, así como concentradores con elementos refractivos (lente de Fresnel). Con la necesidad de aumentar la eficiencia de los sistemas HCPV reales y con el fin de proporcionar la división más eficiente del espectro solar, células conteniendo cuatro o más uniones (con un potencial de alcanzar eficiencias de más del 45% a una concentración de cientos de soles) se exploran hoy en día. En esta tesis se presenta una de las posibles arquitecturas de división del espectro (spectrum-splitting en la literatura anglosajona) que utilizan células de concentración comercial. Otro campo de aplicación de la óptica nonimaging es la iluminación, donde es necesario proporcionar un patrón de distribución de la iluminación específico. La iluminación de estado sólido (SSL), basada en la electroluminiscencia de materiales semiconductores, está proporcionando fuentes de luz para aplicaciones de iluminación general. En la última década, los diodos emisores de luz (LED) de alto brillo han comenzado a reemplazar a las fuentes de luz convencionales debido a la superioridad en la calidad de la luz emitida, elevado tiempo de vida, compacidad y ahorro de energía. Los colimadores utilizados con LEDs deben cumplir con requisitos tales como tener una alta eficiencia, un alto control del haz de luz, una mezcla de color espacial y una gran compacidad. Presentamos un colimador de luz free-form con microestructuras capaz de conseguir buena colimación y buena mezcla de colores con una fuente de LED RGGB. Una buena mezcla de luz es importante no sólo para simplificar el diseño óptico de la luminaria sino también para evitar hacer binning de los chips. La mezcla de luz óptica puede reducir los costes al evitar la modulación por ancho de pulso y otras soluciones electrónicas patentadas para regulación y ajuste de color. Esta tesis consta de cuatro capítulos. Los capítulos que contienen la obra original de esta tesis son precedidos por un capítulo introductorio donde se presentan los conceptos y definiciones básicas de la óptica geométrica y en el cual se engloba la óptica nonimaging. Contiene principios de la óptica no formadora de imagen junto con la descripción de sus problemas y métodos de diseño. Asimismo se describe el método de Superficies Múltiples Simultáneas (SMS), que destaca por su versatilidad y capacidad de controlar varios haces de rayos. Adicionalmente también se describe la integración Köhler y sus aplicaciones en el campo de la energía fotovoltaica. La concentración fotovoltaica y la iluminación de estado sólido son introducidas junto con la revisión de su estado actual. El Segundo y Tercer Capítulo contienen diseños ópticos avanzados con aplicación en la concentración solar principalmente, mientras que el Cuarto Capítulo describe el colimador free-form con surcos que presenta buena mezcla de colores para aplicaciones de iluminación. El Segundo Capítulo describe dos concentradores ópticos HCPV diseñados con el método SMS en tres dimensiones (SMS3D) que llevan a cabo integración Köhler en dos direcciones con el fin de proporcionar una distribución de irradiancia uniforme libre de aberraciones cromáticas sobre la célula solar. Uno de los diseños es el concentrador XXR free-form diseñado con el método SMS3D, donde el espejo primario (X) y la lente secundaria (R) se dividen en cuatro sectores simétricos y llevan a cabo la integración Köhler (proporcionando cuatro unidades del array Köhler), mientras que el espejo intermedio (X) presenta simetría rotacional. Otro concentrador HCPV presentado es el Fresnel-RXI (FRXI) con una lente de Fresnel funcionando como elemento primario (POE) y una lente RXI como elemento óptico secundario (SOE), que presenta configuración 4-fold con el fin de realizar la integración Köhler. Las lentes RXI son dispositivos nonimaging conocidos, pero su aplicación como elemento secundario es novedosa. Los concentradores XXR y FRXI Köhler son ejemplos académicos de muy alta concentración (más de 2,000x, mientras que los sistemas convencionales hoy en día no suelen llegar a 1,000x) preparados para las células solares N-unión (con N>3), que probablemente requerirán una mayor concentración y alta uniformidad espectral de irradiancia con el fin de obtener sistemas CPV terrestres eficientes y rentables. Ambos concentradores están diseñados maximizando funciones de mérito como la eficiencia óptica, el producto concentración-aceptancia (CAP) y la uniformidad de irradiancia sobre la célula libre de la aberración cromática (integración Köhler). El Tercer Capítulo presenta una arquitectura para la división del espectro solar basada en un módulo HCPV con alta concentración (500x) y ángulo de aceptancia alto (>1º) que tiene por objeto reducir ambas fuentes de pérdidas de las células triple unión (3J) comerciales: el uso eficiente del espectro solar y la luz reflejada de los contactos metálicos y de la superficie de semiconductor. El módulo para la división del espectro utiliza el espectro solar más eficiente debido a la combinación de una alta eficiencia de una célula de concentración 3J (GaInP/GaInAs/Ge) y una de contacto posterior (BPC) de concentración de silicio (Si), así como la técnica de confinamiento externo para la recuperación de la luz reflejada por la célula 3J con el fin de ser reabsorbida por la célula. En la arquitectura propuesta, la célula 3J opera con su ganancia de corriente optimizada (concentración geométrica de 500x), mientras que la célula de silicio trabaja cerca de su óptimo también (135x). El módulo de spectrum-splitting consta de una lente de Fresnel plana como POE y un concentrador RXI free-form como SOE con un filtro paso-banda integrado en él. Tanto POE como SOE realizan la integración Köhler para producir homogeneización de luz sobre la célula. El filtro paso banda envía los fotones IR en la banda 900-1,150nm a la célula de silicio. Hay varios aspectos prácticos de la arquitectura del módulo presentado que ayudan a reducir la complejidad de los sistemas spectrum-splitting (el filtro y el secundario forman una sola pieza sólida, ambas células son coplanarias simplificándose el cableado y la disipación de calor, etc.). Prototipos prueba-de-concepto han sido ensamblados y probados a fin de demostrar la fabricabilidad del filtro y su rendimiento cuando se combina con la técnica de reciclaje de luz externa. Los resultados obtenidos se ajustan bastante bien a los modelos y a las simulaciones e invitan al desarrollo de una versión más compleja de este prototipo en el futuro. Dos colimadores sólidos con surcos free-form se presentan en el Cuarto Capítulo. Ambos diseños ópticos están diseñados originalmente usando el método SMS3D. La segunda superficie ópticamente activa está diseñada a posteriori como una superficie con surcos. El diseño inicial de dos espejos (XX) está diseñado como prueba de concepto. En segundo lugar, el diseño RXI free-form es comparable con los colimadores RXI existentes. Se trata de un diseño muy compacto y eficiente que proporciona una muy buena mezcla de colores cuando funciona con LEDs RGB fuera del eje óptico como en los RGB LEDs convencionales. Estos dos diseños son dispositivos free-form diseñados con la intención de mejorar las propiedades de mezcla de colores de los dispositivos no aplanáticos RXI con simetría de revolución y la eficiencia de los aplanáticos, logrando una buena colimación y una buena mezcla de colores. La capacidad de mezcla de colores del dispositivo no-aplanático mejora añadiendo características de un aplanático a su homólogo simétrico sin pérdida de eficiencia. En el caso del diseño basado en RXI, su gran ventaja consiste en su menor coste de fabricación ya que el proceso de metalización puede evitarse. Aunque algunos de los componentes presentan formas muy complejas, los costes de fabricación son relativamente insensibles a la complejidad del molde, especialmente en el caso de la producción en masa (tales como inyección de plástico), ya que el coste del molde se reparte entre todas las piezas fabricadas. Por último, las últimas dos secciones son las conclusiones y futuras líneas de investigación. ABSTRACT Nonimaging optics is a branch of optics whose development began in the mid-1960s. This rather new field of optics focuses on the efficient light transfer necessary in many applications, among which we highlight solar concentrators and illumination systems. The classical optics solutions to the problems of light energy transfer are only appropriate when the light rays are paraxial. The paraxial condition is not met in most applications for the concentration and illumination. This thesis explores several free-form designs (with neither rotational nor linear symmetry) whose applications are intended to cover the above mentioned areas and more. The term nonimaging comes from the fact that these optical systems do not need to form an image of the object, although it is not a necessary condition not to form an image. Another word sometimes used instead of nonimaging is anidolic, and it comes from the Greek “an+eidolon” and has the same meaning. Most of the optical systems designed for nonimaging applications are without any symmetry, i.e. free-form. Free-form optical systems become especially relevant lately with the evolution of free-form tooling (injection molding machines, multi-axis machining techniques, etc.). Nevertheless, only recently there are nonimaging design techniques that are able to meet these degrees of freedom. In illumination applications, the SMS3D method allows designing two free-form surfaces to control very well extended sources. In cases when source, target or volumetric constrains have very asymmetric requirements free-form surfaces are offering solutions with higher efficiency or with fewer elements in comparison with rotationally symmetric solutions, as free-forms have more degrees of freedom and they can perform multiple functions due to their free-form nature. Anidolic concentrators are well suited for the collection of solar energy, because the goal is not the reproduction of an exact image of the sun, but instead the collection of its energy. At this time, Concentration Photovoltaics (CPV) field is turning to high concentration systems in order to compensate the expense of multi-junction (MJ) solar cells used as receivers by reducing its area. Interest in the use of MJ cells lies in their very high conversion efficiency. High Concentration Photovoltaic systems (HCPV) with geometric concentration of more than 500x are required in order to have competitive systems in terrestrial applications. These systems comprise two (or more) optical elements, mirrors and/or lenses. Systems presented in this thesis encompass both main types of HCPV architectures: concentrators with primary reflective element and concentrators with primary refractive element (Fresnel lens). Demand for the efficiency increase of the actual HCPV systems as well as feasible more efficient partitioning of the solar spectrum, leads to exploration of four or more junction solar cells or submodules. They have a potential of reaching over 45% efficiency at concentration of hundreds of suns. One possible architectures of spectrum splitting module using commercial concentration cells is presented in this thesis. Another field of application of nonimaging optics is illumination, where a specific illuminance distribution pattern is required. The Solid State Lighting (SSL) based on semiconductor electroluminescence provides light sources for general illumination applications. In the last decade high-brightness Light Emitting Diodes (LEDs) started replacing conventional light sources due to their superior output light quality, unsurpassed lifetime, compactness and energy savings. Collimators used with LEDs have to meet requirements like high efficiency, high beam control, color and position mixing, as well as a high compactness. We present a free-form collimator with microstructures that performs good collimation and good color mixing with RGGB LED source. Good light mixing is important not only for simplifying luminaire optical design but also for avoiding die binning. Optical light mixing may reduce costs by avoiding pulse-width modulation and other patented electronic solutions for dimming and color tuning. This thesis comprises four chapters. Chapters containing the original work of this thesis are preceded by the introductory chapter that addresses basic concepts and definitions of geometrical optics on which nonimaging is developed. It contains fundamentals of nonimaging optics together with the description of its design problems, principles and methods, and with the Simultaneous Multiple Surface (SMS) method standing out for its versatility and ability to control several bundles of rays. Köhler integration and its applications in the field of photovoltaics are described as well. CPV and SSL fields are introduced together with the review on their background and their current status. Chapter 2 and Chapter 3 contain advanced optical designs with primarily application in solar concentration; meanwhile Chapter 4 portrays the free-form V-groove collimator with good color mixing property for illumination application. Chapter 2 describes two HCPV optical concentrators designed with the SMS method in three dimensions (SMS3D). Both concentrators represent Köhler integrator arrays that provide uniform irradiance distribution free from chromatic aberrations on the solar cell. One of the systems is the XXR free-form concentrator designed with the SMS3D method. The primary mirror (X) of this concentrator and secondary lens (R) are divided in four symmetric sectors (folds) that perform Köhler integration; meanwhile the intermediate mirror (X) is rotationally symmetric. Second HCPV concentrator is the Fresnel-RXI (FRXI) with flat Fresnel lens as the Primary Optical Element (POE) and an RXI lens as the Secondary Optical Element (SOE). This architecture manifests 4-fold configuration for performing Köhler integration (4 array units), as well. The RXI lenses are well-known nonimaging devices, but their application as SOE is novel. Both XXR and FRXI Köhler HCPV concentrators are academic examples of very high concentration (more than 2,000x meanwhile conventional systems nowadays have up to 1,000x) prepared for the near future N-junction (N>3) solar cells. In order to have efficient and cost-effective terrestrial CPV systems, those cells will probably require higher concentrations and high spectral irradiance uniformity. Both concentrators are designed by maximizing merit functions: the optical efficiency, concentration-acceptance angle (CAP) and cell-irradiance uniformity free from chromatic aberrations (Köhler integration). Chapter 3 presents the spectrum splitting architecture based on a HCPV module with high concentration (500x) and high acceptance angle (>1º). This module aims to reduce both sources of losses of the actual commercial triple-junction (3J) solar cells with more efficient use of the solar spectrum and with recovering the light reflected from the 3J cells’ grid lines and semiconductor surface. The solar spectrum is used more efficiently due to the combination of a high efficiency 3J concentration cell (GaInP/GaInAs/Ge) and external Back-Point-Contact (BPC) concentration silicon (Si) cell. By employing external confinement techniques, the 3J cell’s reflections are recovered in order to be re-absorbed by the cell. In the proposed concentrator architecture, the 3J cell operates at its optimized current gain (at geometrical concentration of 500x), while the Si cell works near its optimum, as well (135x). The spectrum splitting module consists of a flat Fresnel lens (as the POE), and a free-form RXI-type concentrator with a band-pass filter embedded in it (as the SOE), both POE and SOE performing Köhler integration to produce light homogenization. The band-pass filter sends the IR photons in the 900-1,150nm band to the Si cell. There are several practical aspects of presented module architecture that help reducing the added complexity of the beam splitting systems: the filter and secondary are forming a single solid piece, both cells are coplanar so the heat management and wiring is simplified, etc. Two proof-of-concept prototypes are assembled and tested in order to prove filter manufacturability and performance, as well as the potential of external light recycling technique. Obtained measurement results agree quite well with models and simulations, and show an opened path to manufacturing of the Fresnel RXI-type secondary concentrator with spectrum splitting strategy. Two free-form solid V-groove collimators are presented in Chapter 4. Both free-form collimators are originally designed with the SMS3D method. The second mirrored optically active surface is converted in a grooved surface a posteriori. Initial two mirror (XX) design is presented as a proof-of-concept. Second, RXI free-form design is comparable with existing RXI collimators as it is a highly compact and a highly efficient design. It performs very good color mixing of the RGGB LED sources placed off-axis like in conventional RGB LEDs. Collimators described here improve color mixing property of the prior art rotationally symmetric no-aplanatic RXI devices, and the efficiency of the aplanatic ones, accomplishing both good collimation and good color mixing. Free-form V-groove collimators enhance the no-aplanatic device's blending capabilities by adding aplanatic features to its symmetric counterpart with no loss in efficiency. Big advantage of the RXI design is its potentially lower manufacturing cost, since the process of metallization may be avoided. Although some components are very complicated for shaping, the manufacturing costs are relatively insensitive to the complexity of the mold especially in the case of mass production (such as plastic injection), as the cost of the mold is spread in many parts. Finally, last two sections are conclusions and future lines of investigation.