965 resultados para central venous pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential source of CVC colonisation was assessed. Isolates of coagulase-negative staphylococci (CoNS) recovered from the skin and CVC components of 3 cardiothoracic surgery patients were characterised by pulsed-field gel electrophoresis (PFGE). The genetic heterogeneity of CoNS isolated from the skin was demonstrated and specific genotypes implicated in catheter colonisation. In addition, phenotypic and genotypic typing techniques were assessed for their ability to characterise strains of CoNS recovered from 33 patients who developed catheter-related bloodstream infection (CR-BSI) on a bone marrow transplant (BMT) unit and Siaphylococcus aureus recovered from 6 cardiothoracic surgery patients with surgical site infection (SSI) following median sternotomy. This epidemiological investigation revealed that common strains of CoNS and 51 aureus where not associated with infection in patients with CR-BSI or sternal SSI during the study period. Furthermore, there was no correlation between phenotypic and genotypic characterisation results. The variable expression of phenotypic traits within strains of staphylococci was evident whilst PFGE and randomly amplified polymorphic DNA (RAPD) were highly discriminatory for the molecular characterisation of S. aureus and CoNS. This was highlighted in 8 stem cell transplant (SCT) patients whereby it was demonstrated that routine identification and characterisation of CoNS by phenotypic techniques may not be adequate for the diagnosis of CR-BSI by current guidelines. The potential of the lipid S ELISA to facilitate the diagnosis of CR-BSI in 38 haematology/SCT patients and sternal SSI in 57 cardiothoracic surgery patients was also assessed. The ELISA proved to be a sensitive test for the rapid serodiagnosis of infection due to staphylococci in immunocompetent patients. The acridine orange leucocyte cytospin test (AOLC) was also evaluated for the rapid diagnosis of CR-BSI in 16 haematology/SCT patients with Hickman CVC in situ. Although the sensitivity of the test was low, it may provide a useful adjunct to conventional methods for the in situ sampling of catheters to predict and diagnose CR-BSI, preventing the unnecessary removal of CVC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intravascular catheters are one of the main causes of bacteraemia and septicaemia in hospitalised patients and continue to be associated with a significant morbidity and mortality. Two main types of infections occur, they can be either localised at the catheter insertion site of systemic with a septicaemia. The clinical parameters related to these infections are presented. The laboratory diagnosis of these infections is also extensively reviewed and recommendations are made as to the most appropriate diagnostic method to be used. © 2005 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

2002 Mathematics Subject Classification: 62P10.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and objectives Central venous catheterization of the internal jugular vein is a commonly performed invasive procedure associated with a significant morbidity and even mortality. Ultrasound-guided methods have shown to significantly improve the success of the technique and are recommended by various scientific societies, including the American Society of Anesthesiologists. The aim of this report is to describe an innovative ultrasound-guided central line placement of the internal jugular vein. Technique The authors describe an innovative ultrasound-guided central line placement of the internal jugular vein based on an oblique approach – the “Syringe-Free” approach. This technique allows immediate progression of the guide wire in the venous lumen, while maintaining a real-time continuous ultrasound image. Conclusions The described method adds to the traditional oblique technique the possibility of achieving a continuous real-time ultrasound-guided venipuncture and a guide wire insertion that does not need removing the probe from the puncture field, while having a single operator performing the whole procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the possibility of producing circulatory arrest by occlusion of the pulmonary trunk as an alternative to the venous inflow occlusion through the left hemithorax. Eight healthy mongrel dogs were divided in two groups. Group I underwent 4 minutes of outflow occlusion and Group II was submitted to 8 minutes of circulatory arrest. Outflow occlusion was performed through left thoracotomy and pericardiotomy by passing a Rumel tourniquet around the pulmonary trunk. Physical examination, electrocardiography, echocardiography, blood gas analyses, hemodynamic, and oxygen transport variables were obtained before and after the procedure. The dogs from Group I did not have any clinical, electrocardiographic, echocardiographic, or hemo-dynamic abnormalities after anesthetic recover. In the Group II, only one dog survived, which had no clinical, electrocardiographic, or echocardiographic abnormalities. In this last dog, just after releasing the occlusion, it was detected increases in the following parameters: heart rate (HR), systolic, diastolic and mean arterial blood pressure (SAP; DAP; MAP), pulmonary artery pressure (PAP), pulmonary wedge pressure (PWP), central venous pressure (CVP), cardiac output (CO), systolic index (SI), cardiac index (CI), left and right ventricular stroke work (LVSW; RVSW), oxygen delivery index (DO2), oxygen consumption index (VO2), and oxygen extraction (O2 ext). Moreover, the oxygen content of arterial and mixed venous blood (CaO2; CvO2), and the arterial and mixed venous partial pressure of oxygen (PaO2; PvO2) were decreased 5 minutes after circulatory arrest. Outflow occlusion is a feasible surgical procedure for period of 4 minutes of circulatory arrest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar os efeitos hemodinâmicos e metabólicos, após a administração de solução salina hipertônica (NaCL) 7,5% ou em associação ao hidroxietilamido (HES), em cães com hipovolemia induzida e tratados com cetamina. Após a indução da hipovolemia, administrou-se NaCl 7,5% (4,0ml kg-1) no grupo hipertônica levógira (GHL) e grupo hipertônica racêmica (GHR) ou HES 130/0,4 na mesma proporção de sangue retirado, associado a NaCl 7,5% (4ml kg-1) no grupo hipertônica colóide levógira (GHCL) e no grupo hipertônica colóide racêmica (GHCR). Após 30 minutos, administrou-se, por via IV, cetamina levógira (CL) (5mg kg-1) no GHL e GHCL ou cetamina racêmica (CR) (10mg kg-1) no GHR e GHCR. Empregou-se a análise de variância de uma única via com repetições múltiplas (ANOVA) e o teste de Student Newman Keuls (P£0,05). A frequência cardíaca e a pressão arterial sistólica foram menores após a hipovolemia e após a CR. As pressões arteriais média e diastólica foram menores após a hipovolemia e cetamina. A pressão venosa central foi maior após a administração do colóide. Os índices cardíaco e sistólico foram menores após a hipovolemia em todos os grupos e, após a fase de expansão no GHL e GHR. A pressão média da artéria pulmonar foi menor após a hipovolemia em todos os grupos. A pressão de oclusão da artéria pulmonar foi maior após o colóide. O índice do trabalho ventricular esquerdo foi menor após a hipovolemia no GHCL e GHCR. O índice da resistência periférica total foi maior após a hipovolemia e menor após a CL. Observou-se acidose metabólica após a hipovolemia e após a cetamina. Ocorreu acidose respiratória após a cetamina no GHL e GHR. Conclui-se que a administração de NaCl 7,5% associado ao HES 130/0,4 promove o restabelecimento imediato dos parâmetros hemodinâmicos e metabólicos no paciente hipovolêmico; a administração isolada de NaCl 7,5% não é capaz de restaurar a PAM no período imediato, mas melhora os demais parâmetros hemodinâmicos e metabólicos; a administração de CR ou CL produz efeitos hemodinâmicos e metabólicos similares no paciente hipovolêmico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o objetivo de avaliar um protocolo de diarréia osmótica induzida, foram utilizados 18 bezerros hígidos, com idade entre oito e 30 dias de vida, e peso variando de 37 a 50kg. A diarréia e a desidratação foram induzidas por meio da administração de leite integral (16,5mL kg-1), sacarose (4g kg-1), espirolactona e hidroclorotiazida (2mg kg-1), a cada oito horas, durante dois dias. O exame físico e as coletas de sangue para determinações de componentes do hemograma, hemogasometria e de constituintes bioquímicos foram realizados em T0 (0h), T1 (24hi) e T2 (48hi). O protocolo de indução da diarréia obteve 100% de eficiência, produzindo diarréia aquosa e desidratação intensa (13% do peso corpóreo) acompanhadas de azotemia pré-renal, aumento nos valores do hematócrito, hemoglobina e proteína total, hipercalemia, hiperlactemia, hiperfosfatemia, acidose metabólica e diminuição do défict de volume plasmático e da pressão venosa central.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose: Carbon dioxide pneumoperitoneum is associated with significant hypercarbia and acidosis. The aim of this study is to evaluate the effects of carbon dioxide and helium pneumoperitoneum on renal function. Materials and Methods: Thirty adult dogs were put randomly into one of three groups ( n = 10 animals each): group A - pneumoperitoneum not performed; group B - CO2 pneumoperitoneum; and group C - helium pneumoperitoneum. The groups were analyzed with consideration given to body weight, hematologic values, hemodynamic parameters ( heart rate, mean arterial pressure, central venous pressure, cardiac output, stroke volume, systemic vascular resistance, pulmonary vascular resistance, left cardiac work index, cardiac index, mean pulmonary artery pressure, and pulmonary capillary wedge pressure), and renal function ( plasma renin activity, urinary output, creatinine clearance, and sodium excretory fraction). Results: An accentuated decrease in urinary output was observed during pneumoperitoneum in groups B and C compared to the control group. In groups B and C, creatinine clearance declined significantly during pneumoperitoneum in comparison to group A, but after deflation a faster recovery of glomerular filtration was noticed for group C, and a significant increase in sodium excretory fraction was seen for group B. On the other hand, in comparison to the control group, group B had a significant increase in plasma renin activity, with late recovery of glomerular function. Conclusion: Helium ameliorates renal alterations when used for pneumoperitoneum, and it might be used for patients with compromised renal function who have to undergo laparoscopic surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and objectives: Cardiac positioning and stabilization during myocardial revascularization without extracorporeal circulation (ECC) may cause hemodynamic changes dependent to the surgical site. The objective of this study was to evaluate these changes during distal coronary anastomosis. Methods: Twenty adult patients undergoing myocardial revascularization without ECC were monitored by pulmonary artery catheter and transesophageal Echo Doppler. Hemodynamic data were collected at the following times before removing the stabilizer wall: (1) after volume adjustments, (2) at the beginning of distal anastomosis, and (3) after 5 minutes. Treated coronary arteries were grouped according to their location in the lateral, anterior, or posterior wall. Two-way ANOVA with repetition and Newman-Keuls post-test were used in the analysis. A p value < 0.05 was considered statically significant. Results: During myocardial revascularization without ECC, pulmonary artery wedge pressure showed elevation from 17.7 +/- 6.1 to 19.2 +/- 6.5 (p < 0.001) and 19.4 +/- 5.9 mmHg (p < 0.001), while the central venous pressure went from 13.9 +/- 5.4 to 14.9 +/- 5.9 mmHg (p = 0.007) and 15.1 +/- 6.0 mmHg (p = 0.006). Intermittent cardiac output was reduced from 4.70 +/- 1.43 to 4.23 +/- 1.22 (p < 0.001) and 4.26 +/- 1.25 L.min(-1) (p < 0.001). According to transesophageal Doppler, a significant group-time interaction was observed in cardiac output, which was reduced in the lateral group from 4.08 +/- 1.99 to 2.84 +/- 1.82 (p = 0.02) and 2.86 +/- 1.73 L.min(-1) (p = 0.02), and aortic blood flow, which went from 2.85 +/- 1.39 to 1.99 +/- 1.26 (p = 0.02) and 2.00 +/- 1.21 L.min(-1) (p = 0.02). Other hemodynamic changes were not observed during anastomoses. Conclusions: A significant hemodynamic deterioration was observed during myocardial revascularization without ECC. Transesophageal Doppler detected a decrease in cardiac output only in the lateral group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Hepatectomy remains a complex operation even in experienced hands. The objective of the present study was to describe our experience in liver resections, in the light of liver transplantation, emphasizing the indications for surgery, surgical techniques, complications, and results. Methods: The medical records of 53 children who underwent liver resection for primary or metastatic hepatic tumors were reviewed. Ultrasonography, computed tomographic (CT) scan, and needle biopsy were the initial methods used to diagnose malignant tumors. After neoadjuvant chemotherapy, tumor resectability was evaluated by another CT scan. Surgery was performed by surgeons competent in liver transplantation. As in liver living donor operation, vascular anomalies were investigated. The main arterial anomalies found were the right hepatic artery emerging from the superior mesenteric artery and left hepatic artery from left gastric artery. Hilar structures were dissected very close to liver parenchyma. The hepatic artery and portal vein were dissected and ligated near their entrance to the liver parenchyma to avoid damaging the hilar vessels of the other lobe. During dissection of the suprahepatic veins, the venous infusion was decreased to reduce central venous pressure and potential bleeding from hepatic veins and the vena cava. Results: Fifty-three children with hepatic tumors underwent surgical treatment, 47 patients underwent liver resections, and in 6 cases, liver transplantation was performed because the tumor was considered unresectable. There were 31 cases of hepatoblastoma, with a 9.6% mortality rate. Ten children presented with other malignant tumors-3 undifferentiated sarcomas, 2 hepatocellular carcinomas, 2 fibrolamellar hepatocellular carcinomas, a rhabdomyosarcoma, an immature ovarian teratoma, and a single neuroblastoma. These cases had a 50% mortality rate. Six children had benign tumors-4 mesenchymal hamartoma, 1 focal nodular hyperplasia, and a mucinous cystadenoma. All of these children had a favorable outcome. Hepatic resections included 22 right lobectomies, 9 right trisegmentectomies, 8 left lobectomies, 5 left trisegmentectomies, 2 left segmentectomies, and 1 case of monosegment (segment IV) resection. The overall mortality rate was 14.9%, and all deaths were related to recurrence of malignant disease. The mortality rate of hepatoblastoma patients was less than other malignant tumors (P = .04). Conclusion: The resection of hepatic tumors in children requires expertise in pediatric surgical practice, and many lessons learned from liver transplantation can be applied to hepatectomies. The present series showed no mortality directly related to the surgery and a low complication rate. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The functional haemodynamic variables pulse pressure variation (PPV), stroke volume variation (SVV), and systolic pressure variation (SPV) are widely used to assess haemodynamic status. However, it is not known how these perform during acute lung injury (ALI). This study evaluated the effects of different ventilatory strategies on haemodynamic parameters in pigs with ALI during normovolaemia and hypovolaemia. Methods. Eight anaesthetized Agroceres pigs [40 (1.9) kg] were instrumented with pulmonary artery, PiCCO, and arterial catheters and ventilated. Three ventilatory settings were randomly assigned for 10 min each: tidal volume (VT) 15 ml kg(-1) and PEEP 5 cm H(2)O, VT 8 ml kg(-1) and PEEP 13 cm H(2)O, or VT 6 ml kg(-1) and PEEP 13 cm H(2)O. Data were collected at each setting at baseline, after ALI (lung lavage+Tween 1.5%), and ALI with hypovolaemia (haemorrhage to 30% of estimated blood volume). Results. At baseline, high VT increased PPV, SVV, and SPV (P < 0.05 for all). During ALI, high VT significantly increased PPV and SVV [(P = 0.002 and P = 0.008) respectively.]. After ALI with hypovolaemia, ventilation at VT 6 ml kg(-1) and PEEP 13 cm H(2)O decreased the accuracy of functional haemodynamic variables to predict hypovolaemia, with the exception of PPV (area under the curve 0.875). The parameters obtained by PiCCO were less influenced by ventilatory changes. Conclusions. VT is the ventilatory parameter which influences functional haemodynamics the most. During ventilation with low VT and high PEEP, most functional variables are less able to accurately predict hypovolaemia secondary to haemorrhage, with the exception of PPV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.