994 resultados para cardiac valve
Resumo:
BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.
Resumo:
BACKGROUND The purpose of this study was to assess the incidence of neurological complications in patients with infective endocarditis, the risk factors for their development, their influence on the clinical outcome, and the impact of cardiac surgery. METHODS AND RESULTS This was a retrospective analysis of prospectively collected data on a multicenter cohort of 1345 consecutive episodes of left-sided infective endocarditis from 8 centers in Spain. Cox regression models were developed to analyze variables predictive of neurological complications and associated mortality. Three hundred forty patients (25%) experienced such complications: 192 patients (14%) had ischemic events, 86 (6%) had encephalopathy/meningitis, 60 (4%) had hemorrhages, and 2 (1%) had brain abscesses. Independent risk factors associated with all neurological complications were vegetation size ≥3 cm (hazard ratio [HR] 1.91), Staphylococcus aureus as a cause (HR 2.47), mitral valve involvement (HR 1.29), and anticoagulant therapy (HR 1.31). This last variable was particularly related to a greater incidence of hemorrhagic events (HR 2.71). Overall mortality was 30%, and neurological complications had a negative impact on outcome (45% of deaths versus 24% in patients without these complications; P<0.01), although only moderate to severe ischemic stroke (HR 1.63) and brain hemorrhage (HR 1.73) were significantly associated with a poorer prognosis. Antimicrobial treatment reduced (by 33% to 75%) the risk of neurological complications. In patients with hemorrhage, mortality was higher when surgery was performed within 4 weeks of the hemorrhagic event (75% versus 40% in later surgery). CONCLUSIONS Moderate to severe ischemic stroke and brain hemorrhage were found to have a significant negative impact on the outcome of infective endocarditis. Early appropriate antimicrobial treatment is critical, and transitory discontinuation of anticoagulant therapy should be considered.
Resumo:
BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.
Resumo:
A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.
Resumo:
Five days after surgical repair of pectus excavatum, this 7-year-old boy had a right-sided Kirschner wire protruding beneath the skin. The wire was repositioned blindly. Severe congestive heart failure developed. Surgical exploration showed a pierced right atrium, a torn septal leaflet of the tricuspid valve and noncoronary aortic cusp, and a large traumatic ventricular septal defect. The outcome and the indications and possible complications of surgery are discussed.
Resumo:
OBJECTIVE To evaluate immediate transcatheter aortic valve implantation (TAVI) results and medium-term follow-up in very elderly patients with severe and symptomatic aortic stenosis (AS). METHODS This multicenter, observational and prospective study was carried out in three hospitals. We included consecutive very elderly (> 85 years) patients with severe AS treated by TAVI. The primary endpoint was to evaluate death rates from any cause at two years. RESULTS The study included 160 consecutive patients with a mean age of 87 ± 2.1 years (range from 85 to 94 years) and a mean logistic EuroSCORE of 18.8% ± 11.2% with 57 (35.6%) patients scoring ≥ 20%. Procedural success rate was 97.5%, with 25 (15.6%) patients experiencing acute complications with major bleeding (the most frequent). Global mortality rate during hospitalization was 8.8% (n = 14) and 30-day mortality rate was 10% (n = 16). Median follow up period was 252.24 ± 232.17 days. During the follow-up period, 28 (17.5%) patients died (17 of them due to cardiac causes). The estimated two year overall and cardiac survival rates using the Kaplan-Meier method were 71% and 86.4%, respectively. Cox proportional hazard regression showed that the variable EuroSCORE ≥ 20 was the unique variable associated with overall mortality. CONCLUSIONS TAVI is safe and effective in a selected population of very elderly patients. Our findings support the adoption of this new procedure in this complex group of patients.
Resumo:
Background: Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Methods: Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Results: Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 mu g/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 mu g/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Conclusions: Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report confirms that this procedure is feasible and safe, and provides good results with low incidence of postoperative renal disorders. (Ann Thorac Surg 2010; 89: 1925-33) (C) 2010 by The Society of Thoracic Surgeons
Resumo:
BACKGROUND: The clinical profile and outcome of nosocomial and non-nosocomial health care-associated native valve endocarditis are not well defined. OBJECTIVE: To compare the characteristics and outcomes of community-associated and nosocomial and non-nosocomial health care-associated native valve endocarditis. DESIGN: Prospective cohort study. SETTING: 61 hospitals in 28 countries. PATIENTS: Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the ICE-PCS (International Collaboration on Endocarditis Prospective Cohort Study) from June 2000 to August 2005. MEASUREMENTS: Clinical and echocardiographic findings, microbiology, complications, and mortality. RESULTS: Health care-associated native valve endocarditis was present in 557 (34%) of 1622 patients (303 with nosocomial infection [54%] and 254 with non-nosocomial infection [46%]). Staphylococcus aureus was the most common cause of health care-associated infection (nosocomial, 47%; non-nosocomial, 42%; P = 0.30); a high proportion of patients had methicillin-resistant S. aureus (nosocomial, 57%; non-nosocomial, 41%; P = 0.014). Fewer patients with health care-associated native valve endocarditis had cardiac surgery (41% vs. 51% of community-associated cases; P < 0.001), but more of the former patients died (25% vs. 13%; P < 0.001). Multivariable analysis confirmed greater mortality associated with health care-associated native valve endocarditis (incidence risk ratio, 1.28 [95% CI, 1.02 to 1.59]). LIMITATIONS: Patients were treated at hospitals with cardiac surgery programs. The results may not be generalizable to patients receiving care in other types of facilities or to those with prosthetic valves or past injection drug use. CONCLUSION: More than one third of cases of native valve endocarditis in non-injection drug users involve contact with health care, and non-nosocomial infection is common, especially in the United States. Clinicians should recognize that outpatients with extensive out-of-hospital health care contacts who develop endocarditis have clinical characteristics and outcomes similar to those of patients with nosocomial infection. PRIMARY FUNDING SOURCE: None.
Resumo:
Background and aim of the study: Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. Methods: A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. Results: According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Conclusion: Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is recommended when reoperation is indicated, without waiting for clinical manifestations of structural valve disease.
Resumo:
ABSTRACT: Transapical aortic valve replacement is an established technique performed in high-risk patients with symptomatic aortic valve stenosis and vascular disease contraindicating trans-vascular and trans-aortic procedures. The presence of a left ventricular apical diverticulum is a rare event and the treatment depends on dimensions and estimated risk of embolisation, rupture, or onset of ventricular arrhythmias. The diagnosis is based on standard cardiac imaging and symptoms are very rare. In this case report we illustrate our experience with a 81 years old female patient suffering from symptomatic aortic valve stenosis, respiratory disease, chronic renal failure and severe peripheral vascular disease (logistic euroscore: 42%), who successfully underwent a transapical 23 mm balloon-expandable stent-valve implantation through an apical diverticulum of the left ventricle. Intra-luminal thrombi were absent and during the same procedure were able to treat the valve disease and to successfully exclude the apical diverticulum without complications and through a mini thoracotomy. To the best of our knowledge, this is the first time that a transapical procedure is successfully performed through an apical diverticulum.
Resumo:
OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.
Resumo:
BACKGROUND: The timing of cardiac surgery after stroke in infective endocarditis (IE) remains controversial. We examined the relationship between the timing of surgery after stroke and the incidence of in-hospital and 1-year mortalities. METHODS: Data were obtained from the International Collaboration on Endocarditis-Prospective Cohort Study of 4794 patients with definite IE who were admitted to 64 centers from June 2000 through December 2006. Multivariate logistic regression and Cox regression analyses were performed to estimate the impact of early surgery on hospital and 1-year mortality after adjustments for other significant covariates. RESULTS: Of the 857 patients with IE complicated by ischemic stroke syndromes, 198 who underwent valve replacement surgery poststroke were available for analysis. Overall, 58 (29.3%) patients underwent early surgical treatment vs 140 (70.7%) patients who underwent late surgical treatment. After adjustment for other risk factors, early surgery was not significantly associated with increased in-hospital mortality rates (odds ratio, 2.308; 95% confidence interval [CI], .942-5.652). Overall, probability of death after 1-year follow-up did not differ between 2 treatment groups (27.1% in early surgery and 19.2% in late surgery group, P = .328; adjusted hazard ratio, 1.138; 95% CI, .802-1.650). CONCLUSIONS: There is no apparent survival benefit in delaying surgery when indicated in IE patients after ischemic stroke. Further observational analyses that include detailed pre- and postoperative clinical neurologic findings and advanced imaging data (eg, ischemic stroke size), may allow for more refined recommendations on the optimal timing of valvular surgery in patients with IE and recent stroke syndromes.
Resumo:
Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.
Resumo:
Background: Transcatheter aortic valve implantations (TAVI) are indicated in high risk patients requiring aortic valve replacement (AVR). However, CT-scans, coronary angiograms and intraoperative aortographies can induce contrast-related nephro-toxicity with a concrete risk of acute postoperative renal failure, especially in severely diseased patients. To prevent this complication, we routinely perform transapical (TA) TAVI guided by transesophageal echocardiogram and fluoroscopy without angiography. Material and Methods: From November 2008 to December 2009, 31 high-risk patients suffering from severe symptomatic aortic stenosis underwent TA-TAVI in our institution. The preoperative imaging assessment (cardiac CT-scan and coronary angiogram) was performed no less than 10 days before the TA-TAVI in all patients (to recover the renal function) with a low-dose protocol for injected contrast medium (equivalent to the patient's weight for the CT-scan). During the TA-TAVI, the stent-valve positioning was performed without any contrast injection. Results: 32 consecutive stent-valve were successfully positioned in 31 patients (mean age 80.76 8 8.3 years; mean EuroSCORE: 32.2 8 12.9%) through a transapical access (1 patient required 2 valves for valve embolisation). The mean preoperative creatinine and urea blood levels were 102.6 8 67.7 _ g/dl (range 53-339 _ g/dl) and 8.45 8 4.9 mmol/l, respectively. A chronic renal insufficiency affected 12 patients (38.7%) with 1 patient in pre-dialysis. Postoperatively, no patient developed acute myocardial infarction, atrio-ventricular block or acute renal insufficiency (mean creatinine level: 89.7 8 64.55 _ g/dl; urea level: 7.11 8 3.47 mmol/l) and the 30-days mortality was 9.67% (3 patients). Conclusion: Specific preoperative and intraoperative protocols that require lowdoses or absence of contrast medium are useful to preserve the renal function in high risk patients operated for TAVI.