934 resultados para buck converter,conducted emission,2-150kHz,DC-microgrid
Resumo:
Modern power networks incorporate communications and information technology infrastructure into the electrical power system to create a smart grid in terms of control and operation. The smart grid enables real-time communication and control between consumers and utility companies allowing suppliers to optimize energy usage based on price preference and system technical issues. The smart grid design aims to provide overall power system monitoring, create protection and control strategies to maintain system performance, stability and security. This dissertation contributed to the development of a unique and novel smart grid test-bed laboratory with integrated monitoring, protection and control systems. This test-bed was used as a platform to test the smart grid operational ideas developed here. The implementation of this system in the real-time software creates an environment for studying, implementing and verifying novel control and protection schemes developed in this dissertation. Phasor measurement techniques were developed using the available Data Acquisition (DAQ) devices in order to monitor all points in the power system in real time. This provides a practical view of system parameter changes, system abnormal conditions and its stability and security information system. These developments provide valuable measurements for technical power system operators in the energy control centers. Phasor Measurement technology is an excellent solution for improving system planning, operation and energy trading in addition to enabling advanced applications in Wide Area Monitoring, Protection and Control (WAMPAC). Moreover, a virtual protection system was developed and implemented in the smart grid laboratory with integrated functionality for wide area applications. Experiments and procedures were developed in the system in order to detect the system abnormal conditions and apply proper remedies to heal the system. A design for DC microgrid was developed to integrate it to the AC system with appropriate control capability. This system represents realistic hybrid AC/DC microgrids connectivity to the AC side to study the use of such architecture in system operation to help remedy system abnormal conditions. In addition, this dissertation explored the challenges and feasibility of the implementation of real-time system analysis features in order to monitor the system security and stability measures. These indices are measured experimentally during the operation of the developed hybrid AC/DC microgrids. Furthermore, a real-time optimal power flow system was implemented to optimally manage the power sharing between AC generators and DC side resources. A study relating to real-time energy management algorithm in hybrid microgrids was performed to evaluate the effects of using energy storage resources and their use in mitigating heavy load impacts on system stability and operational security.
Resumo:
Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available protection concepts and devices for AC systems in a DC network, were presented. A study was also conducted on the effect of changing the distribution architecture and distributing the storage assets on the various zones of the network on the system's dynamic security and stability. A practical shipboard power system was studied as an example of a hybrid AC/DC power system involving pulsed loads. Generally, the proposed hybrid AC/DC power system, besides most of the ideas, controls and algorithms presented in this dissertation, were experimentally verified at the Smart Grid Testbed, Energy Systems Research Laboratory. All the developments in this dissertation were experimentally verified at the Smart Grid Testbed.
Resumo:
Mytilus edulis were cultured for 3 months under six different seawater pCO2 levels ranging from 380 to 4000 µatm. Specimen were taken from Kiel Fjord (Western Baltic Sea, Germany) which is a habitat with high and variable seawater pCO2 and related shifts in carbonate system speciation (e.g., low pH and low CaCO3 saturation state). Hemolymph (HL) and extrapallial fluid (EPF) samples were analyzed for pH and total dissolved inorganic carbon (CT) to calculate pCO2 and [HCO3]. A second experiment was conducted for 2 months with three different pCO2 levels (380, 1400 and 4000 µatm). Boron isotopes (delta11B) were investigated by LA-MC-ICP-MS (Laser Ablation-Multicollector-Inductively Coupled Plasma-Mass Spectrometry) in shell portions precipitated during experimental treatment time. Additionally, elemental ratios (B/Ca, Mg/Ca and Sr/Ca) in the EPF of specimen from the second experiment were measured via ICP-OES (Inductively Coupled Plasma-Optical Emission Spectrometry). Extracellular pH was not significantly different in HL and EPF but systematically lower than ambient water pH. This is due to high extracellular pCO2 values, a prerequisite for metabolic CO2 excretion. No accumulation of extracellular [HCO3] was measured. Elemental ratios (B/Ca, Mg/Ca and Sr/Ca) in the EPF increased slightly with pH which is in accordance with increasing growth and calcification rates at higher seawater pH values. Boron isotope ratios were highly variable between different individuals but also within single shells. This corresponds to a high individual variability in fluid B/Ca ratios and may be due to high boron concentrations in the organic parts of the shell. The mean delta11B value shows no trend with pH but appears to represent internal pH (EPF) rather than ambient water pH.
Resumo:
Modern power networks incorporate communications and information technology infrastructure into the electrical power system to create a smart grid in terms of control and operation. The smart grid enables real-time communication and control between consumers and utility companies allowing suppliers to optimize energy usage based on price preference and system technical issues. The smart grid design aims to provide overall power system monitoring, create protection and control strategies to maintain system performance, stability and security. This dissertation contributed to the development of a unique and novel smart grid test-bed laboratory with integrated monitoring, protection and control systems. This test-bed was used as a platform to test the smart grid operational ideas developed here. The implementation of this system in the real-time software creates an environment for studying, implementing and verifying novel control and protection schemes developed in this dissertation. Phasor measurement techniques were developed using the available Data Acquisition (DAQ) devices in order to monitor all points in the power system in real time. This provides a practical view of system parameter changes, system abnormal conditions and its stability and security information system. These developments provide valuable measurements for technical power system operators in the energy control centers. Phasor Measurement technology is an excellent solution for improving system planning, operation and energy trading in addition to enabling advanced applications in Wide Area Monitoring, Protection and Control (WAMPAC). Moreover, a virtual protection system was developed and implemented in the smart grid laboratory with integrated functionality for wide area applications. Experiments and procedures were developed in the system in order to detect the system abnormal conditions and apply proper remedies to heal the system. A design for DC microgrid was developed to integrate it to the AC system with appropriate control capability. This system represents realistic hybrid AC/DC microgrids connectivity to the AC side to study the use of such architecture in system operation to help remedy system abnormal conditions. In addition, this dissertation explored the challenges and feasibility of the implementation of real-time system analysis features in order to monitor the system security and stability measures. These indices are measured experimentally during the operation of the developed hybrid AC/DC microgrids. Furthermore, a real-time optimal power flow system was implemented to optimally manage the power sharing between AC generators and DC side resources. A study relating to real-time energy management algorithm in hybrid microgrids was performed to evaluate the effects of using energy storage resources and their use in mitigating heavy load impacts on system stability and operational security.
Resumo:
Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available protection concepts and devices for AC systems in a DC network, were presented. A study was also conducted on the effect of changing the distribution architecture and distributing the storage assets on the various zones of the network on the system’s dynamic security and stability. A practical shipboard power system was studied as an example of a hybrid AC/DC power system involving pulsed loads. Generally, the proposed hybrid AC/DC power system, besides most of the ideas, controls and algorithms presented in this dissertation, were experimentally verified at the Smart Grid Testbed, Energy Systems Research Laboratory. All the developments in this dissertation were experimentally verified at the Smart Grid Testbed.
Resumo:
In recent years, the 380V DC and 48V DC distribution systems have been extensively studied for the latest data centers. It is widely believed that the 380V DC system is a very promising candidate because of its lower cable cost compared to the 48V DC system. However, previous studies have not adequately addressed the low reliability issue with the 380V DC systems due to large amount of series connected batteries. In this thesis, a quantitative comparison for the two systems has been presented in terms of efficiency, reliability and cost. A new multi-port DC UPS with both high voltage output and low voltage output is proposed. When utility ac is available, it delivers power to the load through its high voltage output and charges the battery through its low voltage output. When utility ac is off, it boosts the low battery voltage and delivers power to the load form the battery. Thus, the advantages of both systems are combined and the disadvantages of them are avoided. High efficiency is also achieved as only one converter is working in either situation. Details about the design and analysis of the new UPS are presented. For the main AC-DC part of the new UPS, a novel bridgeless three-level single-stage AC-DC converter is proposed. It eliminates the auxiliary circuit for balancing the capacitor voltages and the two bridge rectifier diodes in previous topology. Zero voltage switching, high power factor, and low component stresses are achieved with this topology. Compared to previous topologies, the proposed converter has a lower cost, higher reliability, and higher efficiency. The steady state operation of the converter is analyzed and a decoupled model is proposed for the converter. For the battery side converter as a part of the new UPS, a ZVS bidirectional DC-DC converter based on self-sustained oscillation control is proposed. Frequency control is used to ensure the ZVS operation of all four switches and phase shift control is employed to regulate the converter output power. Detailed analysis of the steady state operation and design of the converter are presented. Theoretical, simulation, and experimental results are presented to verify the effectiveness of the proposed concepts.
Resumo:
The world is quickly changing, and the field of power electronics assumes a pivotal role in addressing the challenges posed by climate change, global warming, and energy management. The introduction of wide-bandgap semiconductors, particularly gallium nitride (GaN), in contrast to the traditional silicon technology, is leading to lightweight, compact and evermore efficient circuitry. However, GaN technology is not mature yet and still presents reliability issues which constrain its widespread adoption. Therefore, GaN reliability is a hotspot for the research community. Extensive efforts have been directed toward understanding the physical mechanisms underlying the performance and reliability of GaN power devices. The goal of this thesis is to propose a novel in-circuit degradation analysis in order to evaluate the long-term reliability of GaN-based power devices accurately. The in-circuit setup is based on measure-stress-measure methodology where a high-speed synchronous buck converter ensures the stress while the measure is performed by means of full I-V characterizations. The switch from stress mode to characterization mode and vice versa is automatic thanks to electromechanical and solid-state relays controlled by external unit control. Because these relays are located in critical paths of the converter layout, the design has required a comprehensive study of electrical and thermal problems originated by the use of GaN technology. In addition, during the validation phase of the converter, electromagnetic-lumped-element circuit simulations are carried out to monitor the signal integrity and junction temperature of the devices under test. However, the core of this work is the in-circuit reliability analysis conducted with 80 V GaN HEMTs under several operating conditions of the converter in order to figure out the main stressors which contribute to the device's degradation.
Resumo:
Two studies demonstrate dissociation between children's understanding of pictorial representations (photos and drawings) and mental representations (beliefs). In Study 1, 37 preschoolers were tested on false belief, appearance-reality, false photo, and false drawing tasks. The false picture tasks were significantly easier, and no correlation was found between children's performances on false belief and false picture tasks. Ln Study 2, 30 children who failed a false belief pretest were randomly assigned to 3 training groups: Belief (trained on false belief tasks), Picture (trained on false picture tasks), or Control (trained on number conservation tasks). Training was conducted in 2 sessions over the course of 2 weeks, tasks were presented and feedback was provided. All children were posttested on theory of mind tasks, false picture tasks, and a number conservation task. The posttest results showed differential patterns of performance, with the Belief group scoring highest on the theory of mind posttests, the Picture group scoring highest on the false picture posttests, and the Control group scoring highest on the number conservation posttest. Results are discussed with respect to competing models of theory of mind development.
Resumo:
The hepatic disposition and metabolite kinetics of a homologous series of diflunisal O-acyl esters (acetyl, butanoyl, pentanoyl, anti hexanoyl) were determined using a single-pass perfused in situ rat liver preparation. The experiments were conducted using 2% BSA Krebs-Henseleit buffer (pH 7.4), and perfusions were performed at 30 mL/min in each liver. O-Acyl esters of diflunisal and pregenerated diflunisal were injected separately into the portal vein. The venous outflow samples containing the esters and metabolite diflunisal were analyzed by high performance liquid chromatography (HPLC). The normalized outflow concentration-time profiles for each parent ester and the formed metabolite, diflunisal, were analyzed using statistical moments analysis and the two-compartment dispersion model. Data (presented as mean +/- standard error for triplicate experiments) was compared using ANOVA repeated measures, significance level P < 0.05. The hepatic availability (AUC'), the fraction of the injected dose recovered in the outflowing perfusate, for O-acetyldiflunisal (C2D = 0.21 +/- 0.03) was significantly lower than the other esters (0.34-0.38). However, R-N/f(u), the removal efficiency number R-N divided by the unbound fraction in perfusate f(u), which represents the removal efficiency of unbound ester by the liver, was significantly higher for the most lipophilic ester (O-hexanoyldiflunisal, C6D = 16.50 +/- 0.22) compared to the other members of the series (9.57 to 11.17). The most lipophilic ester, C6D, had the largest permeability surface area (PS) product (94.52 +/- 38.20 mt min-l g-l liver) and tissue distribution value VT (35.62 +/- 11.33 mL g(-1) liver) in this series. The MTT of these O-acyl esters of diflunisal were not significantly different from one another. However, the metabolite diflunisal MTTs tended to increase with the increase in the parent ester lipophilicity (11.41 +/- 2.19 s for C2D to 38.63 +/- 9.81 s for C6D). The two-compartment dispersion model equations adequately described the outflow profiles for the parent esters and the metabolite diflunisal formed from the O-acyl esters of diflunisal in the liver.
Resumo:
The effects of 4 estrus synchronization treatments on intervals to and synchrony of estrus and ovulation, on timing of the preovulatory LH surge and associated changes in plasma progesterone, LH, FSH, and 17 beta-estradiol (E(2)) were investigated in 48 Bos indicus cows. Treatment 1 consisted of 2 injections of PGF(2 alpha) 14 d apart (n = 12); Treatment 2 of a subcutaneous 3-mg norgestomet implant and an intramuscular injection of 3 mg of norgestomet and 5 mg estradiol valerate, with the implant removed 10 d later (n = 12; norgestomet-estradiol); Treatment 3 of norgestomet-estradiol, with a subcutaneous injection of PMSG given at time of implant removal (Day 10; n = 12); and Treatment 4 of norgestomet implant (as for Treatments 2 and 3) inserted for 10 d, with an intramuscular injection of PGF(2 alpha) given at the time of implant removal (n = 12). The experiment was conducted in 2 replicates (24 cows/replicate, 6 cows/group). Estrus, ovulation and timing of the preovulatory surge of LH varied less in cows treated with norgestomet-estradiol and PMSG than in cows in Treatments 1 and 4 (P < 0.008). Treatment with PMSG;educed variation in ovulation times and timing of the LH surge in cows treated with norgestomet-estradiol (P < 0.02). Concentrations of E(2) were higher in cows in Treatments 2 and 3 on the final day of treatment and at about 6 h post ovulation compared with cows in Treatments 1 and 4 (P < 0.05). Different methods for synchronizing estrus did not alter sequential endocrine and behavioral changes in relation to the timing of the LH peak, and the results were consistent with current recommendations for insemination times in Bos taurus cattle. (C) 1997 by Elsevier Science Inc.
Resumo:
Objective:To determine the risk factors for the presence of moderate/severe vertebral fracture, specifically 25-hydroxyvitamin D (25-OHD). Study design: Cross-sectional study conducted for 2 years in the city of Sao Paulo, Brazil including community-dwelling elderly women. Methods: Bone mineral density (BMD), serum 25-OHD, intact parathyroid hormone (iPTH), calcium and estimated glomerular filtration rate (eGFR) were examined in 226 women without vertebral fractures (NO FRACTURE group) and 189 women with at least one moderate/severe vertebral fracture (FRACTURE group). Vertebral fracture assessment (VFA) was evaluated using both the Genant semiquantitative (SQ) approach and morphometry. Results: Patients in the NO FRACTURE group had lower age, increased height, higher calcium intake, and higher BMD compared to those patients in the FRACTURE group (p < 0.05). Of interest, serum levels of 25-OHD in the NO FRACTURE group were higher than those observed in the FRACTURE group (51.73 nmol/L vs. 42.31 nmol/L, p < 0.001). Reinforcing this finding, vitamin D insufficiency (25-OHD < 75 nmol/L) was observed less in the NO FRACTURE group (82.3% vs. 93.65%, p = 0.001). After adjustment for significant variables within the patient population (age, height, race, calcium intake, 25-OHD, eGFR and sites BMD), the logistic-regression analyses revealed that age (OR = 1.09, 95% Cl 1.04-1.14, p < 0.001) femoral neck BMD (OR = 0.7, 95% CI 0.6-0.82, p < 0.001) and 25-OHD <75 nmol/L (OR = 2.38, 95% CI 1.17-4.8, p = 0.016) remains a significant factor for vertebral fracture. Conclusion: Vitamin D insufficiency is a contributing factor for moderate/severe vertebral fractures. This result emphasizes the importance of including this modifiable risk factor in the evaluation of elderly women. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background and Aims: Submucosal injection of a viscoelastic solution prolongs submucosal lift, thus, facilitating endoscopic mucosal resection. Our objective was to assess the safety and clinical effectiveness of 0.4% hydroxypropyl methylcellulose (HPMC) as a submucosal injectant for endoscopic mucosal resection. Patients and Methods: A prospective, open-label, multicenter, phase 2 study was conducted at 2 academic institutions in Brazil. Eligible participants included patients with early gastrointestinal tumors larger than 10 mm. Outcomes evaluated included complete resection rates, volume of HPMC injected, duration of the submucosal cushion as assessed visually, histology of the resected leisons, and complication rates. Results: Over a 12-month period, 36 eligible patients with superficial neoplastic lesions (stomach 14, colon 11, rectum 5, esophagus 3, duodenum 3) were prospectively enrolled in the study. The mean size of the resected specimen was 20.4 mm (10 to 60 mm). The mean volume of 0.4% HPMC injected was 10.7 mL (range 4 to 35 mL). The mean duration of the submucosal fluid cushion was 27 minutes (range 9 to 70 min). Complete resection was successfully completed in 89%. Five patients (14%) developed immediate bleeding requiring endoclip and APC application. Esophageal perforation occurred in 1 patient requiring surgical intervention. There were no local or systemic adverse events related to HPMC use over the follow-up period (mean 2.2 mo). Conclusion: HPMC solution (0.4%) provides an effective submucosal fluid cushion and is safe for endoscopic resection of early gastrointestinal neoplastic lesions.
Resumo:
Cerebral toxoplasmosis is the most common cerebral mass lesion in AIDS patients in Brazil, and results in high mortality and morbidity, despite free access to HAART (highly active antiretroviral treatment). Molecular diagnosis based on conventional PCR (cnPCR) or real-time quantitative PCR (qrtPCR) has been indispensable for definitive diagnosis. We report here the evaluation of qrtPCR with blood and cerebrospinal fluid (CSF) samples from AIDS patients in Brazil. This prospective study was conducted for 2 years, analysing DNA samples extracted from 149 AIDS patients (98 blood and 51 CSF samples) with confirmed clinical and radiological diagnosis The laboratory diagnosis included cnPCR (with the B22/B23 primer set) and indirect immunofluorescence (IF). For qrtPCR, two primer sets were simultaneously designed based on described genes and using a 6-carboxyfluorescein dye-labelled TaqMan MGB (minor groove binder) probe One was Bug, which amplified a sequence from the B1 gene The other was the RETg, which amplified a PCR product of the 529 bp sequence. The overall cnPCR and qrtPCR results were positive results were observed in 33.6% (50) patients The sensitivities were 98% for cnPCR (B22/B23), and 86 and 98% for qrtPCR (B1Tg and RETg, respectively). Negative reactions were observed in 66 4% patients. The specificities were 97% for cnPCR and qrtPCR (B1Tg). and 88.8% for RETg These data show that RETg PCR is highly sensitive as it amplifies a repeat region with many copies; however, its specificity is lower than the other markers However, B1Tg PCR had good specificity, but lower sensitivity Among the patients, 20 had blood and CSF collected simultaneously Thus, their results permitted us to analyse and compare molecular, serological and clinical diagnosis for a better understanding of the different scenarios of laboratorial and clinical diagnosis. For nine patients with confirmed cerebral toxoplasmosis diagnosis, four scenarios were observed: (i) and (ii) negative molecular diagnosis for CSF and positive for blood with variable IF titres for the sera and CSF (negative or positive), (iii) positive molecular diagnosis with CSF and negative with blood, and (iv) positive molecular diagnosis in both samples. In the latter two situations, normally the IF titres in sera and CSF are variable. Other opportunistic infections were shown in 11 patients Despite the IF titres in sera and CSF being variable, all of them had negative molecular diagnosis for both samples qrtPCR allows for a rapid identification of Toxoplasma gondii DNA in patient samples; in a minority of cases discrepancies occur with the cnPCR.
Resumo:
Objective. This study evaluated the degree of conversion (DC), maximum rate of cure (R(p)(max)), and polymerization stress (PS) developed by an experimental dental composite subjected to different irradiant energies (3,6,12, 24, or 48J/cm(2)) under constant irradiance (500 mw/cm(2)). Methods. DC and R(p)(max) were monitored for 10 min on the bottom surface of 2-mm thick disks and on 150-mu m thick films (representing the top of the specimen) using ATR-FTIR. PS was monitored for 10 min in 2-mm thick disks bonded to two glass rods (O = 5 mm) attached to a universal testing machine. One-way ANOVA/Tukey tests were used and differences in DC and R(p)(max) between top and bottom surfaces were examined using Student`s t-test. Statistical testing was performed at a pre-set alpha of 0.05. Results. For a given surface, DC showed differences among all groups, except at the top between 24 and 48 J/cm(2). R(p)(max) was similar among all groups at the same surface and statistically higher at the top surface. PS also showed significant differences among all groups. Data for 48 J/cm(2) were not obtained due to specimen failure at the glass/composite interface. Significance. Increases in irradiant exposure led to significant increases in DC and PS, but had no effect on R(p)(max) (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para Obtenção do grau de Mestre em Engenharia Electrotécnica e Computadores