986 resultados para bland-Altman method
Resumo:
This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-Altman plots revealed a positive bias in plasma compared to serum but the difference was not considered clinically significant. The results indicate that lithium-heparin plasma samples are suitable for measurement of equine SAA using this method. Use of either serum or plasma allows for greater flexibility when it comes to sample collection although care should be taken when comparing data between measurements from different sample types.
Resumo:
BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are non-oxidative minor metabolites of ethanol. They are detectable in various body fluids shortly after initial consumption of ethanol and have a longer detection time frame than the parent compound. They are regarded highly sensitive and specific markers of recent alcohol uptake. This study evaluates the determination of EtG and EtS from dried blood spots (DBS), a simple and cost-effective sampling method that would shorten the time gap between offense and blood sampling and lead to a better reflectance of the actual impairment. METHODS: For method validation, EtG and EtS standard and quality control samples were prepared in fresh human heparinized blood and spotted on DBS cards, then extracted and measured by an LC-ESI-MS/MS method. Additionally, 76 heparinized blood samples from traffic offense cases were analyzed for EtG and EtS as whole blood and as DBS specimens. The results from these measurements were then compared by calculating the respective mean values, by a matched-paired t test, by a Wilcoxon test, and by Bland-Altman and Mountain plots. RESULTS AND DISCUSSION: Calibrations for EtG and EtS in DBS were linear over the studied calibration range. The precision and accuracy of the method met the requirements of the validation guidelines that were employed in the study. The stability of the biomarkers stored as DBS was demonstrated under different storage conditions. The t test showed no significant difference between whole blood and DBS in the determination of EtG and EtS. In addition, the Bland-Altman analysis and Mountain plot confirmed that the concentration differences that were measured in DBS specimens were not relevant.
Resumo:
CHARACTERIZATION OF THE COUNT RATE PERFORMANCE AND EVALUATION OF THE EFFECTS OF HIGH COUNT RATES ON MODERN GAMMA CAMERAS Michael Stephen Silosky, B.S. Supervisory Professor: S. Cheenu Kappadath, Ph.D. Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and measurement of system dead time (τ) is important for quantitative SPECT. The CRP of three modern gamma cameras was characterized using established methods (Decay and Dual Source) under a variety of experimental conditions. For the Decay method, input count rate was plotted against observed count rate and fit to the paralyzable detector model (PDM) to estimate τ (Rates method). A novel expression for observed counts as a function of measurement time interval was derived and the observed counts were fit to this expression to estimate τ (Counts method). Correlation and Bland-Altman analysis were performed to assess agreement in estimates of τ between methods. The dependencies of τ on energy window definition and incident energy spectrum were characterized. The Dual Source method was also used to estimate τ and its agreement with the Decay method under identical conditions and the effects of total activity and the ratio of source activities were investigated. Additionally, the effects of count rate on several performance metrics were evaluated. The CRP curves for each system agreed with the PDM at low count rates but deviated substantially at high count rates. Estimates of τ for the paralyzable portion of the CRP curves using the Rates and Counts methods were highly correlated (r=0.999) but with a small (~6%) difference. No significant difference was observed between the highly correlated estimates of τ using the Decay or Dual Source methods under identical experimental conditions (r=0.996). Estimates of τ increased as a power-law function with decreasing ratio of counts in the photopeak to the total counts and linearly with decreasing spectral effective energy. Dual Source method estimates of τ varied as a quadratic with the ratio of the single source to combined source activities and linearly with total activity used across a large range. Image uniformity, spatial resolution, and energy resolution degraded linearly with count rate and image distorting effects were observed. Guidelines for CRP testing and a possible method for the correction of count rate losses for clinical images have been proposed.
Resumo:
The use of the SenseWear™ armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 ± 1.48 METs and 32.1 ± 34.0 kcal in favour of the OM system, while for men values of 2.33 ± 1.82 METs and 75.8 ± 50.8 kcal were recorded.
Resumo:
Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.
Resumo:
Background: CO2 monitoring is recommended for thoracic telescopic procedures and for spontaneous breathing general anesthesia in children. During flexible bronchoscopy (FB) in children, the various currently available methods of CO2 measurements are limited. The CO2 falls and increases have been reported in FB but it is unknown whether airway lesions predispose to CO2 change. The aim of this study was to describe and validate endoscopic intratracheal CO2 measurements in children undergoing FB under spontaneously breathing GA. Methods: Endtidal CO2 (PECO2) measurements at the start (Start-CO2) and end (End-CO2) of FB on 100 consecutive children were performed using a newly designed endoscopic intratracheal method. To validate the method blood gas sampling was simultaneously performed in 28 children and results analyzed using the Bland and Altman method, intraclass correlation and 95% range for repeatability. Results: End-CO2 and CO2-change (End-CO2 minus Start-CO2) were significantly different in children with airway lesions (CO2 change: no lesion = 3 mmHg, extrathoracic airway lesion = 4.5, intrathoracic airway lesion = 8, P = 0.038). There was no significant difference in Start-CO2 values among the groups. CO2-change in those aged > 12 months was similar to those >12 months. Intratracheal CO2 measurements were comparable with arterial blood values in the Bland and Altman plots. The intraclass correlation was 0.69 and 95% range for repeatability was 3.7-4.17 mmHg. Conclusions: Midtracheal PECO2 provides a useful estimate of PaCO2 for monitoring the respiratory status of children undergoing FB. The presence of airway lesions rather than age is associated with significant increased PCO2 rise.
Resumo:
Purpose: To compare corneal thickness measurements using Orbscan II (OII) and ultrasonic (US) pachymetry in normal and in keratoconic eyes. Setting: Eye Department, Heartlands and Solihull NHS Trust, Birmingham, United Kingdom. Methods: Central corneal thickness (CCT) was measured by means of OII and US pachymetry in 1 eye of 72 normal subjects and 36 keratoconus patients. The apical corneal thickness (ACT) in keratoconus patients was also evaluated using each method. The mean of the difference, standard deviation (SD), and 95% limits of agreement (LoA = mean ± 2 SD), with and without applying the default linear correction factor (LCF), were determined for each sample. The Student t test was used to identify significant differences between methods, and the correlation between methods was determined using the Pearson bivariate correlation. Bland-Altman analysis was performed to confirm that the results of the 2 instruments were clinically comparable. Results: In normal eyes, the mean difference (± 95% LoA) in CCT was 1.04 μm ± 68.52 (SD) (P>.05; r = 0.71) when the LCF was used and 46.73 ± 75.40 μm (P = .0001; r = 0.71) without the LCF. In keratoconus patients, the mean difference (± 95% LoA) in CCT between methods was 42.46 ± 66.56 μm (P<.0001: r = 0.85) with the LCF, and 2.51 ± 73.00 μm (P>.05: r = 0.85) without the LCF. The mean difference (± 95% LoA) in ACT for this group was 49.24 ± 60.88 μm (P<.0001: r = 0.89) with the LCF and 12.71 ± 68.14 μm (P = .0077; r = 0.89) when the LCF was not used. Conclusions: This study suggests that OII and US pachymetry provide similar readings for CCT in normal subjects when an LCF is used. In keratoconus patients, OII provides a valid clinical tool for the noninvasive assessment of CCT when the LCF is not applied. © 2004 ASCRS and ESCRS.
Resumo:
Purpose. The purpose of the study was to examine Jamaican adolescents in a school setting, for risk factors of type 2 diabetes mellitus (T2DM) and cardiovascular diseases (CVDs). Methods. A descriptive epidemiological cross-sectional study of 276 Jamaican adolescents (112 males and 164 females) ages 14-19 years (15.6±1.2), randomly selected from grades 9-12 from ten high schools on the island. Thirteen risk factors were examined. Risk factors were compared with BMI levels and demographics. A sub-study validated finger prick testing of fasting blood glucose, total cholesterol, and HbA1c versus venous testing in 59 subjects. Results. Prevalence of overweight was 33.0% (n=91) with mean BMI of 23.74±7.74. Approximately 66.7% of subjects reported ≥ 3 risk factors. The number of T2DM and CVDs risk factors increased for subjects with BMI above 25. One third of the overweight subjects were classified with the metabolic syndrome. High BMI was associated with high waist circumference (r = .767, p < .01), high waist-to-hip ratio (r = .180, p < .01), presence of Acanthosis Nigricans (r = .657, p < .01), high total cholesterol (r = .158, p < .01), family history of T2DM (r = .157, p < .01), and hypertension (r = .422, p < .01). Regression analyses significantly predicted gender and physical activity (p < .001), and total number of risk factors for T2DM and CVDs (p < .001). Paired samples t-tests revealed no significant differences between methods of testing for TC and HbA1c (p < .01) but not for FBG (p > .05). Percentage bias for the methods of blood testing met the reference standards for fasting blood glucose but not for total cholesterol and HbA1c. Bland Altman tests of agreement between the two methods indicated good agreement for all three tests. Conclusion. Jamaican adolescents are at high risk for T2DM and CVDs as seen in other study populations. Effective programs to prevent T2DM and CVDs are needed. Family history of diseases, anthropometric measures, and gender identified more subjects at risk than did the biochemical measures. Comparison between finger prick and venous blood methods suggested that finger prick is an adequate method to screen for risk factors in children and adolescents.
Resumo:
Purpose: The purpose of the study was to examine Jamaican adolescents in a school setting, for risk factors of type 2 diabetes mellitus (T2DM) and cardiovascular diseases (CVDs). Methods: A descriptive epidemiological cross-sectional study of 276 Jamaican adolescents (112 males and 164 females) ages 14-19 years (15.6±1.2), randomly selected from grades 9-12 from ten high schools on the island. Thirteen risk factors were examined. Risk factors were compared with BMI levels and demographics. A sub-study validated finger prick testing of fasting blood glucose, total cholesterol, and HbAlc versus venous testing in 59 subjects. Results: Prevalence of overweight was 33.0% (n=91) with mean BMI of 23.74±7.74. Approximately 66.7% of subjects reported > 3 risk factors. The number of T2DM and CVDs risk factors increased for subjects with BMI above 25. One third of the overweight subjects were classified with the metabolic syndrome. High BMI was associated with high waist circumference (r =.767, p (r = .180, p.05). Percentage bias for the methods of blood testing met the reference standards for fasting blood glucose but not for total cholesterol and HbAlc. Bland Altman tests of agreement between the two methods indicated good agreement for all three tests. Conclusion: Jamaican adolescents are at high risk for T2DM and CVDs as seen in other study populations. Effective programs to prevent T2DM and CVDs are needed. Family history of diseases, anthropometric measures, and gender identified more subjects at risk than did the biochemical measures. Comparison between finger prick and venous blood methods suggested that finger prick is an adequate method to screen for risk factors in children and adolescents.
Resumo:
O presente estudo teve como principal objetivo rever a versão original do Protocolo de Avaliação da Qualidade Vocal da Universidade de Aveiro (PAQVUA), criar o respetivo manual, comprovar a validade de conteúdo do PAQVUA assim como a sua fiabilidade inter e intra avaliador. Para rever a versão original do PAQVUA, foi efetuada uma revisão narrativa da literatura, com o objetivo de encontrar informação que revelasse a pertinência, da versão original do protocolo, para assim se efetuarem as alterações necessárias. Para analisar a validade de conteúdo recorreu-se a um painel de peritos, num total de seis, especialistas na área da voz que avaliaram as provas do PAQVUA, folha de registo e manual. Os peritos avaliaram todos os componentes do PAQVUA através do preenchimento de um questionário com o objetivo de se comprovar a relevância, clareza e precisão de cada uma das provas de avaliação e também o conteúdo do seu manual. Para além disso pretendeu-se também comprovar a fiabilidade inter e intra avaliador do PAQVUA. Para isso, o mesmo protocolo foi aplicado duas vezes por duas avaliadoras diferentes e também foi aplicado em dois momentos temporais diferentes por uma só avaliadora. A amostra teve um total de doze participantes. Para analisar estatisticamente os resultados da validade de conteúdo utilizou-se o método gráfico Bland e Altman modificado e o Coeficiente de Correlação Intraclasses (CCI). Para a fiabilidade inter e intra avaliador recorreu-se ao Coeficiente de Correlação de Spearman (ρ) e ao Kappa de Cohen (k). Relativamente aos resultados obtidos com o método Bland e Altman modificado, verificou-se a existência de concordância entre os peritos através da análise dos gráficos, sendo que a maioria dos pontos se encontrou dentro dos limites esperados de concordância. Quanto aos valores do CCI (entre 0.379 e 0.479), estes revelaram uma correlação regular. No que concerne à fiabilidade inter avaliador, os resultados de correlação e concordância apresentaram-se relevantes, com valores de ρ (de Spearman) superiores a 0.700 e valores de k (de Cohen) superiores a 0.600, na maioria dos casos. O mesmo foi constatado para a fiabilidade intra avaliador. Desta forma pode concluir-se que a nova versão do PAQVUA apresenta validade de conteúdo sendo tal comprovado pelo método de Bland-Altman modificado e pelos valores do CCI. Quanto à fiabilidade inter e intra avaliador, pode afirmar-se que o PAQVUA é fiável, porém como a amostra em estudo é pequena, o que a torna pouco representativa, esta conclusão carece de fundamento com base num estudo mais alargado. Apesar da limitação referida, acredita-se que este protocolo é uma mais-valia para o estudo da patologia vocal em ambiente clínico, assim como para a investigação científica nesta área, pois através do PAQVUA podem-se recolher diversas informações relacionadas com a voz, úteis para uma intervenção terapêutica baseada em evidências científicas.
Resumo:
The purpose of the present study was to investigate percentage body fat (%BF) differences in three Spanish dance disciplines and to compare skinfold and bioelectrical impedance predictions of body fat percentage in the same sample. Seventy-six female dancers, divided into three groups, Classical (n=23), Spanish (n=29) and Flamenco (n=24), were measured using skinfold measurements at four sites: triceps, subscapular, biceps and iliac crest, and whole body multi-frequency bioelectrical impedance (BIA). The skin-fold measures were used to predict body fat percentage via Durnin and Womersley's and Segal, Sun and Yannakoulia equations by BIA. Differences in percent fat mass between groups (Classical, Spanish and Flamenco) were tested by using repeated measures analysis (ANOVA). Also, Pearson's product-moment correlations were performed on the body fat percentage values obtained using both methods. In addition, Bland-Altman plots were used to assess agreement, between anthropometric and BIA methods. Repeated measures analysis of variance did not found differences in %BF between modalities (p<0.05). Fat percentage correlations ranged from r= 0.57 to r=0.97 (all, p<0.001). Bland-Altman analysis revealed differences between BIA Yannakoulia as a reference method with BIA Segal (-0.35 ± 2.32%, 95%CI: -0.89to 0.18, p=0.38), with BIA Sun (-0.73 ± 2.3%, 95%CI: -1.27 to -0.20, p=0.014) and Durnin-Womersley (-2.65 ± 2,48%, 95%CI: -3.22 to -2.07, p<0.0001). It was concluded that body fat percentage estimates by BIA compared with skinfold method were systematically different in young adult female ballet dancers, having a tendency to produce underestimations as %BF increased with Segal and Durnin-Womersley equations compared to Yannakoulia, concluding that these methods are not interchangeable.
Resumo:
Regular physical activity (PA) decreases mortality risk in survivors of breast and colorectal cancer. Such impacts of exercise have prompted initiatives designed both to promote and adequately monitor PA in cancer survivors. This study examines the validity of 2 widely used self-report methods for PA determination, the International Physical Activity Questionnaire short version (IPAQ-SF) and Global Physical Activity Questionnaire (GPAQ). Both instruments were compared with the triaxial accelerometry (Actigraph) method as an objective reference standard. Study participants were 204 cancer survivors (both sexes, aged 18-79 years). Compared with accelerometry, both questionnaires significantly overestimated PA levels (across all intensities) and underestimated physical inactivity levels. No differences were detected between the 2 questionnaires except for a shorter inactivity time estimated by GPAQ (p=0.001). The Bland and Altman method confirmed that both questionnaires overestimated all PA levels. Receiver operating characteristic (ROC) analysis classified IPAQ and GPAQ as fair and poor predictors, respectively, of the proportions of survivors fulfilling international PA recommendations (≥150 min·week-1 of moderate-vigorous PA). IPAQ-SF showed a higher sensitivity but lower specificity than GPAQ. Our data do not support the use of IPAQ-SF or GPAQ to determine PA or inactivity levels in cancer survivors.
Resumo:
The aim of this study is to test the feasibility and reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) evaluations of the fetal brains in cases of twin-twin transfusion syndrome (TTTS). From May 2011 to June 2012, 24 patients with severe TTTS underwent MRI scans for evaluation of the fetal brains. Datasets were analyzed offline on axial DW images and apparent diffusion coefficient (ADC) maps by two radiologists. The subjective evaluation was described as the absence or presence of water diffusion restriction. The objective evaluation was performed by the placement of 20-mm(2) circular regions of interest on the DW image and ADC maps. Subjective interobserver agreement was assessed by the kappa correlation coefficient. Objective intraobserver and interobserver agreements were assessed by proportionate Bland-Altman tests. Seventy-four DW-MRI scans were performed. Sixty of them (81.1%) were considered to be of good quality. Agreement between the radiologists was 100% for the absence or presence of diffusion restriction of water. For both intraobserver and interobserver agreement of ADC measurements, proportionate Bland-Altman tests showed average percentage differences of less than 1.5% and 95% CI of less than 18% for all sites evaluated. Our data demonstrate that DW-MRI evaluation of the fetal brain in TTTS is feasible and reproducible.
Resumo:
PURPOSE: To compare the 2% ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2% ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física