972 resultados para bacteremia-catheter
Resumo:
Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.
Resumo:
Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.
Resumo:
iii. Catheter-related bloodstream infection (CR-BSI) diagnosis usually involves catheter withdrawal. An alternative method for CR-BSI diagnosis is the differential time to positivity (DTP) between peripheral and catheter hub blood cultures. This study aims to validate the DTP method in short-term catheters. The results show a low prevalence of CR-BSI in the sample (8.4%). The DTP method is a valid alternative for CR-BSI diagnosis in those cases with monomicrobial cultures (80% sensitivity, 99% specificity, 92% positive predictive value, and 98% negative predictive value) and a cut-off point of 17.7 hours for positivity of hub blood culture may assess in CR-BSI diagnosis.
Resumo:
Els catéters venosos centrals són necessaris per al maneig del pacient crític però poden ser l´origen d´una bacteriemia. Aquest estudi prospectiu de cohort té com a objectiu determinar la utilitat de l´aplicació d´unes mesures bàsiques de prevenció per disminuir la incidència de bacteriemia associada a catéter. Els resultats de l´estudi confirmen que l´aplicació d´aquest sistema d´intervenció múltiple basat en l´evidencia redueix de forma significativa les bacteriemies associades a catéter a la nostra UCI.
Resumo:
La sospita de bacterièmia relacionada a catèter (BRC) necessita la retirada d’aquest, confirmant-se a posteriori només en un 15-25%. La diferencia en el temps de positivització d´ hemocultius (DTP) ha demostrat ser un mètode fiable per el diagnòstic de BRC evitant la retirada del catèter. Amb la intenció de comprovar la utilitat clínica de la DTP, l’hem comparada amb un mètode diagnòstic estàndard. Hem inclòs 133 pacients ingressats a una unitat de cures intensives portadors de catèters venosos centrals. 56 pacients s’han aleatoritzats. No hem trobat diferències significatives en quant a morbi-mortalitat en els 2 grups havent evitat 70% de retirada innecessària de catèters en el grup de DTP.
Resumo:
A new, investigational, parenteral form of sparfloxacin was compared with ceftriaxone in the treatment of experimental endocarditis caused by either of three penicillin-susceptible streptococci or one penicillin-resistant streptococcus. Both drugs have prolonged half-lives in serum, allowing single daily administration to humans. Sparfloxacin had relatively low MICs (0.25 to 0.5 mg/liter) for all four organisms and was also greater than or equal to eight times more effective than the other quinolones against 21 additional streptococcal isolates recovered from patients with bacteremia. Ceftriaxone MICs were 0.032 to 0.064 mg/liter for the penicillin-susceptible strains and 2 mg/liter for the resistant isolate. Both antibiotics resulted in moderate bacterial killing in vitro. Rats with catheter-induced aortic vegetations were inoculated with 10(7) CFU of the test organisms. Antibiotic treatment was started 48 h later and lasted either 3 or 5 days. The drugs were injected at doses which mimicked the kinetics in human serum produced by one intravenous injection of 400 mg of sparfloxacin (i.e., the daily dose expected to be given to human adults) and 2 g of ceftriaxone. Both antibiotics significantly decreased the bacterial densities in the vegetations. However, sparfloxacin was slower than ceftriaxone in its ability to eradicate valvular infection caused by penicillin-susceptible bacteria. While this difference was quite marked after 3 days of therapy, it tended to vanish when treatment was prolonged to 5 days. In contrast, sparfloxacin was very effective against the penicillin-resistant isolate, an organism against which ceftriaxone therapy failed in vivo. No sparfloxacin-resistant mutant was selected during therapy. Thus, in the present experimental setting, this new, investigational, parenteral form of sparfloxacin was effective against severe infections caused by both penicillin-susceptible and penicillin-resistant streptococci.
Resumo:
Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
Resumo:
Over the past two decades, nosocomial infections caused by extended-spectrum beta-lactamase (ESBL)-producing Klebsiella spp. have become a major problem all around the world. This situation is of concern because there are limited antimicrobial options to treat patients infected with these pathogens, and also because this kind of resistance can spread to a wide variety of Gram-negative bacilli. Our objectives wereto evaluate among in-patients at a publicuniversity tertiary-care hospital with documented infection due to Klebsiella spp., which were the risk factors (cross-sectional analysis) and the clinical impact (prospective cohort) associated with an ESBL-producing strain. Study subjects were all patients admitted at the study hospital between April 2002 and October 2003, with a clinically and microbiologically confirmed infection caused by Klebsiella spp. at any body site, except infections restricted to the urinary tract. Of the 104 patients studied, 47 were infected with an ESBL-producing strain and 57 with a non-ESBL-producing strain. Independent risk factors associated with infection with an ESBL-producing strain were young age, exposure to mechanical ventilation, central venous catheter, use of any antimicrobial agent, and particularly use of a 4th generation cephalosporin or a quinolone. Length of stay was significant longer for patients infected with ESBL-producing strains than for those infected with non-ESBL-producing strains, although fatality rate was not significantly affected by ESBL-production in this cohort. In fact, mechanical ventilation and bacteremia were the only variables withindependent association withdeath detected in this investigation.
Resumo:
We describe a case of bacteremia due to an as yet unclassified Acinetobacter genomic species 17-like strain. The recognition of this microorganism as non-Acinetobacter baumannii may have important epidemiological implications, as it relieves the hospital of the implementation of barrier precautions for patients infected or colonized as may be necessary with a multiresistant A. baumannii epidemic.
Resumo:
Extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli, particularly those producing CTX-M types of ESBL, are emerging pathogens. Bacteremia caused by these organisms represents a clinical challenge, because the organisms are frequently resistant to the antimicrobials recommended for treatment of patients with suspected E. coli sepsis. METHODS:A cohort study was performed that included all episodes of bloodstream infection due to ESBL-producing E. coli during the period from January 2001 through March 2005. Data on predisposing factors, clinical presentation, and outcome were collected. ESBLs were characterized using isoelectric focusing, polymerase chain reaction, and sequencing. RESULTS: Forty-three episodes (8.8% of cases of bacteremia due to E. coli) were included; 70% of the isolates produced a CTX-M type of ESBL. The most frequent origins of infection were the urinary (46%) and biliary tracts (21%). Acquisition was nosocomial in 21 cases (49%), health care associated in 14 cases (32%), and strictly community acquired in 8 cases (19%). Thirty-eight percent and 25% of patients had obstructive diseases of the urinary and biliary tracts, respectively, and 38% had recently received antimicrobials. Nine patients (21%) died. Compared with beta-lactam/beta-lactamase-inhibitor and carbapenem-based regimens, empirical therapy with cephalosporins or fluoroquinolones was associated with a higher mortality rate (9% vs. 35%; P=.05) and needed to be changed more frequently (24% vs. 78%; P=.001). CONCLUSIONS: ESBL-producing E. coli is a significant cause of bloodstream infection in hospitalized and nonhospitalized patients in the context of the emergence of CTX-M enzymes. Empirical treatment of sepsis potentially caused by E. coli may need to be reconsidered in areas where such ESBL-producing isolates are present.
Resumo:
Streptococcus pneumoniae remains an important cause of bacteremia worldwide. Last years, a decrease of S. pneumoniae penicillin-resistant isolates has been observed. The objective of this study was to describe the episodes of bacteremia due to S. pneumoniae during a period of 11 years. Epidemiological and clinical data, serotypes causing bacteremia, antibiotic susceptibility and prognosis factors were studied. Over a period of 11 years, all the episodes of S. pneumoniae bacteremia were analysed. Their clinical and microbiological features were recorded. Statistical analysis was carried out to determine risk factors for pneumococcal bacteremia and predictors of fatal outcome. Finally, 67 S. pneumoniae bacteremia episodes were included in this study. The majority of cases were produced in white men in the middle age of their life. The main predisposing factors observed were smoking, antimicrobial and/or corticosteroids administration, chronic pulmonary obstructive disease and HIV infection, and the most common source of bacteremia was the low respiratory tract. The main serotypes found were 19A, 1, 14 and 7F. Seventy-seven percent of these isolates were penicillin-susceptible, and the mortality in this serie was really low. Statistical significance was observed between age, sex and race factors and the presence of bacteremia, and there was relationship between the patient’s condition and the outcome. In our study, S. pneumoniae bacteremia is mainly from community-acquired origin mainly caused in men in the median age of the life. 40% of bacteremias were caused by serotypes 19A, 1, 7F and 14. During the period of study the incidence of bacteremia was stable and the mortality rate was very low.
Resumo:
The diagnosis of infections involving internal or external neurosurgical drainage devices is challenging, and to our knowledge no single reliable microbiological test exists. We used sonication to study bacterial colonization in 14 explanted external ventricular drains (EVD) and 13 ventriculo-peritoneal shunt (VPS) devices. This technique dislodges biofilm bacteria from the surface of implanted materials before culture. Removed devices were sonicated in saline (40 kHz, 1 minute, 0.25 W/cm(2)), the resulting fluid was cultured aerobically and anaerobically at 37°C, and bacterial growth was counted. Ventricular cerebrospinal fluid (CSF) was cultured separately. In the EVD group, sonication cultures grew significantly more bacteria (64%, 9/14) than cultures of aspirated ventricular CSF (14%, 2/14). In the VPS group the difference was not significant. Positive sonication cultures of EVD catheters yielded a median of >100 colony forming units (CFU) (range, 60-800). For positive sonication cultures of VPS, the median was 1000 CFU (range, 20-100,000). All patients with bacteria in their CSF also had positive sonication cultures from the removed device. Of the five patients with sterile or presumably contaminated CSF cultures but positive sonication cultures of removed shunts, one became afebrile after removal of the EVD, two developed meningitis and two remained asymptomatic. Sonication culture of EVD appears to improve the microbiological assessment of device-related infection and it corroborates with CSF cultures of revision surgery for VPS. Sonication of the removed EVD tip may raise awareness for the onset of meningitis.