941 resultados para average current control


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Huoli ympäristön tilasta ja fossiilisten polttoaineiden hinnan nousu ovat vauhdittaneet tutkimusta uusien energialähteiden löytämiseksi. Polttokennot ovat yksi lupaavimmista tekniikoista etenkin hajautetun energiantuotannon, varavoimalaitosten sekä liikennevälineiden alueella. Polttokenno on tehonlähteenä kuitenkin hyvin epäideaalinen, ja se asettaa tehoelektroniikalle lukuisia erityisvaatimuksia. Polttokennon kytkeminen sähköverkkoon on tavallisesti toteutettu käyttämällä galvaanisesti erottavaa DC/DC hakkuria sekä vaihtosuuntaajaa sarjassa. Polttokennon kulumisen estämiseksi tehoelektroniikalta vaaditaan tarkkaa polttokennon lähtövirran hallintaa. Perinteisesti virran hallinta on toteutettu säätämällä hakkurin tulovirtaa PI (Proportional and Integral) tai PID (Proportional, Integral and Derivative) -säätimellä. Hakkurin epälineaarisuudesta johtuen tällainen ratkaisu ei välttämättä toimi kaukana linearisointipisteestä. Lisäksi perinteiset säätimet ovat herkkiä mallinnusvirheille. Tässä diplomityössä on esitetty polttokennon jännitettä nostavan hakkurin tilayhtälökeskiarvoistusmenetelmään perustuva malli, sekä malliin perustuva diskreettiaikainen integroiva liukuvan moodin säätö. Esitetty säätö on luonteeltaan epälineaarinen ja se soveltuu epälineaaristen ja heikosti tunnettujen järjestelmien säätämiseen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This bachelor’s thesis is a part of the research project realized in the summer 2011 in Lappeenranta University of Technology. The goal of the project was to develop an automation concept for controlling the electrically excited synchronous motor. Thesis concentrates on the implementation of the automation concept into the ABB’s AC500 programmable logic enviroment. The automation program was developed as a state machine with the ABB’s PS501 Control Builder software. For controlling the automation program is developed a fieldbus control and with CodeSys Visualization Tool a local control with control panel. The fieldbus control is done to correspond the ABB drives communication profile and the local control is implemented with a function block which feeds right control words into the statemachine. A field current control of the synchronous motor is realized as a method presented in doctoral thesis of Olli Pyrhönen (Pyrhönen 1998). The Method combines stator flux and torque based openloop control and power factor based feedback control.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työssä tutkitaan mahdollisuutta hyödyntää sähkömoottorien nopeudensäätöön suunniteltuja kaupallisia taajuusmuuttajia osana aktiivisesti säädetyn magneettilaakeroinnin säätöjärjestelmää. Magneettilaakerijärjestelmän ohjaamiseksi tarvitaan vahvistin, jonka tehtävänä on muuntaa paikkasäätöjärjestelmältä tuleva ohjearvo virraksi, jännitteeksi tai magneettivuoksi voiman tuottamiseksi laakerikäämityksellä. Nykyaikaiset modernit taajuusmuuttajat mahdollistavat säätöalgoritmien suorittamisen sekä liitynnän muuhun automaatiojärjestelmään kenttäväylien kautta. Tämän järjestelmäintegraation myötä olisi mahdollista rakentaa modulaarinen säätöjärjestelmä hyödyntäen luotettavaksi todettuja teollisuusautomaatiotuotteita vain muutamalla itse magneettilaakerijärjestelmään liittyvällä tuotteella. Haluttaessa hyödyntää kolmivaiheinen taajuusmuuttaja mahdollisimman tehokkaasti magneettilaakerin teholähteenä tulee laakerikäämityksien kytkeytymistä taajuusmuuttajaan tarkastella tarkemmin. Kirjallisuustutkimuksessa keskitytään taajuusmuuttajan tehokytkimien muodostaman vaihtosuuntaajan eri rakennevaihtoehtojen sekä virtasäädön dynaamisten ominaisuuksien tarkasteluun. Soveltuvien rakennevaihtoehtojen sekä virtasäädön suorituskyky todennetaan simuloinnein ja lopuksi todellisella koelaitteistolla. Magneettilaakeroinnilla varustetun sähkökoneen roottorin onnistunut leijuttaminen viiden vapausasteen suhteen paikkasäädettynä sekä mittauksien tulokset osoittavat, ettei taajuusmuuttajien järjestelmäarkkitehtuurista löydy merkittäviä esteitä muuttajien hyödyntämiseksi magneettilaakerisovelluksissa.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The globalization of trade in fish has created many challenges for the developing world specifically with regard to food safety and quality. International organisations have established a good basis for standards in international trade. Whilst these requirements are frequently embraced by the major importers (such as Japan, the EU and the USA), they often impose additional safety requirements and regularly identify batches which fail to meet their strict standards. Creating an effective national seafood control system which meets both the internal national needs as well the requirements for the export market can be challenging. Many countries adopt a dual system where seafood products for the major export markets are subject to tight control whilst the majority of the products (whether for the local market or for more regional trade) are less tightly controlled. With regional liberalization also occurring, deciding on appropriate controls is complex. In the Sultanate of Oman, fisheries production is one of the countries' chief sources of economic revenue after oil production and is a major source of the national food supply. In this paper the structure of the fish supply chain has been analysed and highlighted the different routes operating for the different markets. Although much of the fish are consumed within Oman, there is a major export trade to the local regional markets. Much smaller quantities meet the more stringent standards imposed by the major importing countries and exports to these are limited. The paper has considered the development of the Omani fish control system including the key legislative documents and the administrative structures that have been developed. Establishing modern controls which satisfy the demands of the major importers is possible but places additional costs on businesses. Enhanced controls such as HACCP and other management standards are required but can be difficult to justify when alternative markets do not specify these. These enhanced controls do however provide additional consumer protection and can bring benefits to local consumers. The Omani government is attempting to upgrade the system of controls and has made tremendous progress toward the implementation of HACCP and introducing enhanced management systems into its industrial sector. The existence of strengthened legislative and government support, including subsidies, has encouraged some businesses to implement HACCP. The current control systems have been reviewed and a SWOT analysis approach used to identify key factors for their future development. The study shows that seafood products in the supply chain are often exposed to lengthy handling and distribution process before reaching the consumers, a typical issue faced by many developing countries. As seafood products are often perishable, they safety is compromised if not adequately controlled. The enforcement of current food safety laws in the Sultanate of Oman is shared across various government agencies. Consequently, there is a need to harmonize all regulatory requirements, enhancing the domestic food protection and to continue to work towards a fully risk-based approach in order to compete successfully in the global market.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: O vírus da dengue é transmitido pela picada do mosquito Aedes aegypti e, o atual programa de controle não atinge o objetivo de impedir sua transmissão. Este trabalho objetivou analisar a relação entre a distribuição espaço-temporal de casos de dengue e os indicadores larvários no município de Tupã, de janeiro de 2004 a dezembro de 2007. MÉTODOS: Foram construídos indicadores larvários por quarteirão e totalidade do município. Utilizou-se o método cross-lagged correlation para avaliar a correlação entre casos de dengue e indicadores larvários. Foi utilizado estimador kernel para análise espacial. RESULTADOS: A correlação cruzada defasada entre casos de dengue e indicadores larvários foi significativa. Os mapas do estimador Kernel da positividade de recipientes indicam uma distribuição heterogênea, ao longo do período estudado. Nos dois anos de transmissão, a epidemia ocorreu em diferentes regiões. CONCLUSÕES: Não ficou evidenciada relação espacial entre infestação larvária e ocorrência de dengue. A incorporação de técnicas de geoprocessamento e análise espacial no programa, desde que utilizados imediatamente após a realização das atividades, podem contribuir com as ações de controle, indicando os aglomerados espaciais de maior incidência.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS¡APPC). In the VS¡APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cold atmospheric plasma treatment of microorganisms and living tissues has become a popular topic in modern plasma physics and in medical science. The plasma is capable of bacterial inactivation and noninflammatory tissue modification, which makes it an attractive tool for treatment of skin diseases, open injuries and dental caries. Because of their enhanced plasma chemistry, Dielectric Barrier Discharges (DBDs) have been widely investigated for some emerging applications such as biological and chemical decontamination of media at ambient conditions. Despite the high breakdown voltage in air at atmospheric pressure, the average current of DBD discharges is low. Therefore, a DBD can be applied in direct contact with biological objects without causing any damage. In this work a 60 Hz DBD reactor, which generates cold atmospheric plasma inside Petri dishes with bacterial culture, is investigated. Samples of Staphylococcus aureus, a Gram-positive bacterium and Escherichia coil a Gram-negative bacterium were selected for this study. The bacterial suspensions were evenly spread on agar media planted in Petri dishes. The reactor electrodes were placed outside the Petri dish, thus eliminating the risk of samples microbial contamination. The covered Petri dish with agar medium in it serves as dielectric barrier during the treatment. The plasma processing was conducted at same discharge power (similar to 1.0 W) with different exposure time. Sterilization of E. coil and S. aureus was achieved for less than 20 min. Plasma induced structural damages of bacteria were investigated by Scanning Electron Microscopy. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One of the main problems with dengue is the control of Aedes aegypti, its major vector. In Brazil, the current control program for Ae. aegypti and Aedes albopictus populations includes larval density surveys. An interesting alternative is the use of a distinct index, the Premise Condition Index (PCI). This tool relates conditions of property, such as houses and yards, and the degree of shade with the occurrence of Aedes sp. oviposition, and is calculated as scores from 3 to 9. The lowest score indicates property in good condition and an unfavorable breeding environment, while the highest score indicates property at high risk for infestation by Aedes sp. The present study is based on the application of the PCI in an urban area of Botucatu, Brazil to confirm its effectiveness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Traditionally, an (X) over bar -chart is used to control the process mean and an R-chart to control the process variance. However, these charts are not sensitive to small changes in process parameters. A good alternative to these charts is the exponentially weighted moving average (EWMA) control chart for controlling the process mean and variability, which is very effective in detecting small process disturbances. In this paper, we propose a single chart that is based on the non-central chi-square statistic, which is more effective than the joint (X) over bar and R charts in detecting assignable cause(s) that change the process mean and/or increase variability. It is also shown that the EWMA control chart based on a non-central chi-square statistic is more effective in detecting both increases and decreases in mean and/or variability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The authors present an offline switching power supply with multiple isolated outputs and unity power factor with the use of only one power processing stage, based on the DC-DC SEPIC (single ended primary inductance converter) modulated by variable hysteresis current control. The principle of operation, the theoretical analysis, the design procedure, an example, and simulation results are presented. A laboratory prototype, rated at 160 W, operating at a maximum switching frequency of 100 kHz, with isolated outputs rated at +5 V/15 A -5 V/1 A, +12 V/6 A and -12 V/1 A, has been built given an input power factor near unity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work proposes a new isolated high power factor 12kW power supply based on an 18-pulse transformer arrangement. Three full-bridge converters are used for isolation and to balance the DC-link currents, without current sensing or a current controller. The topology provides a regulated DC output with a very simple control strategy. Simulation and experimental results are presented in this paper.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paperwork presents a Pulse Width Modulation (PWM) speed controller for an electric mini-baja-type car. A battery-fed 1-kW three-phase induction motor provides the electric vehicle traction. The open-loop speed control is implemented with an equal voltage/frequency ratio, in order to maintain a constant amount of torque on all velocities. The PWM is implemented by a low-cost 8-bit microcontroller provided with optimized ROM charts for distinct speed value implementations, synchronized transition between different charts and reduced odd harmonics generation. This technique was implemented using a single passenger mini-baja vehicle, and the essays have shown that its application resulted on reduced current consumption, besides eliminating mechanical parts. Copyright © 2007 by ABCM.