79 resultados para autograft


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Dentoalveolar trauma, especially when involving front teeth, negatively affect the patient’s life; in particular, tooth avulsion is a complex injury that affects multiple tissues, and no treatment option offers stable long-term outcomes. The aim of this study was to report a case of reconstruction of atrophic anterior alveolar ridge after tooth loss, performed with autograft harvested from the chin, and subsequent prosthetic rehabilitation with the use of an osseointegrated implant. Case report A 23-years-old Caucasian girl, presented an atrophic alveolar bone in the area of tooth 11, as a result of tooth resorption 10 years after a tooth reimplantation procedure. Reconstruction was performed with autogenous bone harvested from the chin. After 6-months healing period to allow autograft incorporation, a dental implant was inserted. After further 6- months, a screw-retained implant supported metal-ceramic prosthesis was fabricated. Results The prosthetic rehabilitation was successful, and after a follow-up period of 5 years, the achieved result was stable.Conclusion It can be concluded that the autogenous bone graft harvested from the chin, is a safe and effective option for alveolar ridge defects reconstruction, allowing a subsequent placement of a dental implant supporting a prosthetic restoration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the capacity of natural latex membrane to accelerate and improve the regeneration quality of the of rat sciatic nerves. METHODS: Forty male adult Wistar rats were used, anesthetized and operated to cut the sciatic nerve and receive an autograft or a conduit made with a membrane derived from natural latex (Hevea brasiliensis). Four or eight weeks after surgery, to investigate motor nerve recovery, we analyzed the neurological function by walking pattern (footprints analysis and computerized treadmill), electrophysiological evaluation and histological analysis of regenerated nerve (autologous nerve graft or tissue cables between the nerve stumps), and anterior tibial and gastrocnemius muscles. RESULTS: All functional and morphological analysis showed that the rats transplanted with latex conduit had a better neurological recovery than those operated with autologous nerve: quality of footprints, performance on treadmill (p<0.01), electrophysiological response (p<0.05), and quality of histological aspects on neural regeneration. CONCLUSION: The data reported showed behavioral and functional recovery in rats implanted with latex conduit for sciatic nerve repair, supporting a complete morphological and physiological regeneration of the nerve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il rachide è stato suddiviso in tre colonne da Denis: anteriore e centrale comprendono la metà anteriore del corpo vertebrale, la metà posteriore e l’inizio dei peduncoli, mentre la colonna posteriore comprende l’arco e i peduncoli stessi. In caso di resezione o lesione della colonna anteriore e media è indicata la ricostruzione. Diverse tecniche e materiali possono essere usati per ricostruire il corpo vertebrale. Innesti vascolarizzati, autograft, allograft sono stati usati, così come impianti sintetici di titanio o materiale plastico come il PEEK (Poly etere etere ketone). Tutti questi materiali hanno vantaggi e svantaggi in termini di proprietà intrinseche, resistenza meccanica, modulo di elasticità, possibilità di trasmissione malattie, capacità di fondersi con l’osso ospite o meno. Le soluzioni più usate sono le cage in titanio o carbonio, il PMMA ( Poli methil metacrilato), gli innesti ossei massivi. Si è effettuato uno studio di coorte retrospettivo paragonando due gruppi di pazienti oncologici spinali trattati da due chirurghi esperti in un centro di riferimento, con vertebrectomia e ricostruzione della colonna anteriore: un gruppo con cage in carbonio o titanio, l’altro gruppo con allograft massivo armato di innesto autoplastico o mesh in titanio. Si sono confrontati i risultati in termini di cifosi segmenterai evolutiva, fusione ossea e qualità di vita del paziente. Il gruppo delle cage in carbonio / titanio ha avuto risultati leggermente migliori dal punto di vista biomeccanico ma non statisticamente significativo, mentre dal punto di vista della qualità di vita i risultati sono stati migliori nel gruppo allograft. Non ci sono stati fallimenti meccanici della colonna anteriore in entrambi i gruppi, con un Fu tra 12 e 60 mesi. Si sono paragonati anche i costi delle due tecniche. In conclusione l’allogar è una tecnica sicura ed efficace, con proprietà meccaniche solide, soprattutto se armato con autograft o mesi in titanio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obturator anterior hip dislocation is very rare. Poor results are described in patients with additional large transchondral fractures and treatment of these injuries remains challenging. Appropriate treatment recommendations are missing in the literature. This case report introduces surgical hip dislocation for osteochondral autograft transplantation with graft harvest from the nonweightbearing area of the head-neck junction as a salvage procedure in a large femoral head defect. We report the treatment and outcome of a 48-year-old man who sustained an anterior dislocation of the left hip after a motorcycle accident. After initial closed reduction in the emergency room, imaging analysis revealed a large osteochondral defect of the femoral head within the weightbearing area (10 × 20 mm, depth: 5 mm). The hip was exposed with a surgical hip dislocation using a trochanteric osteotomy. An osteochondral autograft was harvested from a nonweightbearing area of the femoral head and transferred into the defect. The patient was prospectively examined clinically and radiologically. Two years postoperatively, the patient was free of pain and complaints. The function of the injured hip was comparable to that of the contralateral, healthy hip and showed satisfying radiologic results. Surgical hip dislocation with a trochanteric flip osteotomy is a simple, one-step technique that allows full inspection of the hip to treat osteochondral femoral defects by osteochondral transplantation. The presented technique, used as a salvage procedure in a large femoral head defect, yielded good clinical and satisfying radiologic outcomes at the midterm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone graft incorporation depends on the orchestrated activation of numerous growth factors and cytokines in both the host and the graft. Prominent in this signaling cascade is BMP2. Although BMP2 is dispensable for bone formation, it is required for the initiation of bone repair; thus understanding the cellular mechanisms underlying bone regeneration driven by BMP2 is essential for improving bone graft therapies. In the present study, we assessed the role of Bmp2 in bone graft incorporation using mice in which Bmp2 has been removed from the limb prior to skeletal formation (Bmp2(cKO)). When autograft transplantations were performed in Bmp2cKO mice, callus formation and bone healing were absent. Transplantation of either a vital wild type (WT) bone graft into a Bmp2(cKO) host or a vital Bmp2(cKO) graft into a WT host also resulted in the inhibition of bone graft incorporation. Histological analyses of these transplants show that in the absence of BMP2, periosteal progenitors remain quiescent and healing is not initiated. When we analyzed the expression of Sox9, a marker of chondrogenesis, on the graft surface, we found it significantly reduced when BMP2 was absent in either the graft itself or the host, suggesting that local BMP2 levels drive periosteal cell condensation and subsequent callus cell differentiation. The lack of integrated healing in the absence of BMP2 was not due to the inability of periosteal cells to respond to BMP2. Healing was achieved when grafts were pre-soaked in rhBMP2 protein, indicating that periosteal progenitors remain responsive in the absence of BMP2. In contrast to the requirement for BMP2 in periosteal progenitor activation in vital bone grafts, we found that bone matrix-derived BMP2 does not significantly enhance bone graft incorporation. Taken together, our data show that BMP2 signaling is not essential for the maintenance of periosteal progenitors, but is required for the activation of these progenitors and their subsequent differentiation along the osteo-chondrogenic pathway. These results indicate that BMP2 will be among the signaling molecules whose presence will determine success or failure of new bone graft strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: A novel biphasic calcium phosphate (CaP) granulate consisting of hydroxyapatite (HA) and beta-tricalciumphosphate (TCP) was compared with pure HA and pure TCP and with autograft as positive control. MATERIALS AND METHODS: Four standardized bone defects were prepared in both mandibular angles of 16 minipigs and grafted with autogenous bone chips, HA, HA/TCP (60% : 40%), or TCP. Histologic and histomorphometric analysis of bone formation and graft degradation followed healing periods of 2, 4, 8, and 24 weeks. RESULTS: 2 weeks: more bone formation in defects filled with autograft than with the three CaP materials (P<0.05). 4 weeks: bone formation differed significantly (P<0.05) between all four materials (autograft>TCP>HA/TCP>HA). 8 weeks: more bone formation in defects with autograft and TCP than with HA/TCP (P<0.05), and HA/TCP had more bone formation than HA (P<0.05). 24 weeks: no difference in bone formation between the groups. Autograft and TCP resorbed quickly and almost completely over 8 weeks, whereas HA/TCP and HA showed limited degradation over 24 weeks. CONCLUSION: All defects healed with mature lamellar bone and intimate contact between bone and the remaining graft material. The rate of bone formation corresponded to the content of TCP in the CaP materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study reviews our experience with the Ross procedure in infants and young children. METHODS: From September 1993 to September 2004, 52 children less than 15 years of age underwent a Ross procedure. The patients ranged in age from 4 days to 15 years old (median, 5 years). Fifteen patients (29%) were less than 2 years of age. The predominant indication for the Ross procedure was aortic stenosis. Sixteen patients underwent a Ross-Konno procedure for severe left ventricular outflow tract obstruction. Thirty-four patients had 48 previous interventions. Preoperatively, 6 patients showed severe left ventricular dysfunction, and 2 of the patients required ventilation and inotropic support. Concomitant procedures were performed in 8 patients. Three patients had a mitral valve replacement, 2 patients had a ventricular septal defect closure and an aortic arch reconstruction, 2 patients had aortic arch reconstructions, and 1 patient had resection of a coarctation and a ventricular septal defect closure. RESULTS: Patients were followed up for a median of 43 months (range, 1 to 130). Overall survival was 85% +/- 5% at 1 and 82% +/- 5% at 2, 5, and 10 years. Hospital mortality was 5 of 52 patients (9.6%). All deaths occurred in neonates or infants less than 2 months of age, who needed urgent surgery. Three patients died late of noncardiac causes. At last follow-up, all patients were classified in New York Heart Association functional class I or II. No patient had endocarditis of the autograft or the right ventricular outflow tract replacement. During the follow-up, no event of thrombembolism was observed. No patient required the insertion of a permanent pacemaker. Overall freedom from reoperation is 57% +/- 15% at 10 years. One patient required the replacement of the autograft at 6 months postoperatively. The development of mild aortic insufficiency was observed in 24 patients, and moderate aortic insufficiency in 1 patient during follow-up. Freedom from reoperation for the right ventricular outflow tract replacement is 60% +/- 15% at 10 years. CONCLUSIONS: The Ross procedure represents an attractive approach to aortic valve disease in young children. However, a high early mortality rate has to be considered when performing this procedure in neonates or infants who present in critical preoperative condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The objective of the study was to evaluate tissue reactions such as bone genesis, cartilage genesis and graft materials in the early phase of lumbar intertransverse process fusion in a rabbit model using computed tomography (CT) imaging with CT intensity (Hounsfield units) measurement, and to compare these data with histological results. MATERIALS AND METHODS: Lumbar intertransverse process fusion was performed on 18 rabbits. Four graft materials were used: autograft bone (n = 3); collagen membrane soaked with recombinant human bone morphogenetic protein-2 (rhBMP-2) (n = 5); granular calcium phosphate (n = 5); and granular calcium phosphate coated with rhBMP-2 (n = 5). All rabbits were euthanized 3 weeks post-operatively and lumbar spines were removed for CT imaging and histological examination. RESULTS: Computed tomography imaging demonstrated that each fusion mass component had the appropriate CT intensity range. CT also showed the different distributions and intensities of bone genesis in the fusion masses between the groups. Each component of tissue reactions was identified successfully on CT images using the CT intensity difference. Using CT color mapping, these observations could be easily visualized, and the results correlated well with histological findings. CONCLUSIONS: The use of CT intensity is an effective approach for observing and comparing early tissue reactions such as newly synthesized bone, newly synthesized cartilage, and graft materials after lumbar intertransverse process fusion in a rabbit model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Osteochondral autograft transfer (OAT) aims at restoring normal articular cartilage surface geometry and articular contact mechanics. To date, no studies have evaluated the contact mechanics of the canine stifle following OAT. Additionally, there are no studies that evaluated the role of the meniscus in contact mechanics following OAT in human or canine femorotibial joints. The objective of this study was to measure the changes in femorotibial contact areas (CA), mean contact pressure (MCP) and peak contact pressure (PCP) before and after osteochondral autograft transplantation (OAT) of a simulated lateral femoral condylar cartilage defect with an intact lateral meniscus and following lateral meniscectomy. RESULTS With an intact lateral meniscus, creation of an osteochondral defect caused a decrease in MCP and PCP by 11% and 30%, respectively, compared to the intact stifle (p < 0.01). With an intact meniscus, implanting an osteochondral graft restored MCP and PCP to 96% (p = 0.56) and 92% (p = 0.41) of the control values. Lateral meniscectomy with grafting decreased CA by 54% and increased PCP by 79% compared to the intact stifle (p < 0.01). CONCLUSIONS OAT restored contact pressures in stifles with a simulated lateral condylar defect when the meniscus was intact. The lateral meniscus has a significant role in maintaining normal contact pressures in both stifles with a defect or following OAT. Meniscectomy should be avoided when a femoral condylar defect is present and when performing OAT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To test a non-glycosylated recombinant human bone morphogenetic protein-2 (ngly-rhBMP-2)/fibrin composite, which has been shown experimentally to enhance healing of bone defects in rodents, in a clinical case series of dogs and cats undergoing treatment for fracture non-unions and arthrodesis. METHODS A ngly-rhBMP-2/fibrin composite was applied in 41 sites in 38 dogs and cats for which a cancellous bone autograft was indicated, replacing the graft. RESULTS Bridging of the bone defect with functional bone healing was achieved in 90 per cent of the arthrodesis and fracture nonunions treated in this manner. CLINICAL SIGNIFICANCE This prospective clinical study demonstrates the beneficial effects of ngly-rhBMP-2 in a specially designed fibrin matrix on the treatment of bone defects, and validates the use of this composite as an alternative to bone autografts in dogs and cats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Anterior cruciate ligament (ACL) injuries are very common; in Germany incidence of ACL ruptures is estimated at 32 per 100 000 in the general population and in the sports community this rate more than doubles. Current gold standard for anterior cruciate lig- ament repair is reconstruction using an autograft [1]. However, this approach has shown some limitations. A new method has been her- alded by the Knee Team at the Bern University Hospital (Inselspital) and the Sonnenhof clinic called Dynamic Intraligamentary Stabilization (DIS), which keeps ACL remnants in place in order to promote biologi- cal healing and makes use of a dynamic screw system [2]. The aim of this study was to investigate the cytocompatibility of collagen patches in combination with DIS to support regeneration of the ACL. The spe- cific hypothesis we tested was whether MSCs would differentiate towards TCs in co-culture. Materials and methods: Primary Tenocytes (TCs) and human bone marrow derived mesenchymal stem cells (MSCs) were harvested from ACL removed during knee prothesis or from bone marrow aspirations (Ethical Permit 187/10). Cells were seeded on two types of three dimensional carriers currently approved for cartilage repair, Novocart (NC, B. Brown) and Chondro-Gide (CG, Geistlich). These scaffolds comprise collagen structures with interconnecting pores originally developed for seeding of chondrocytes in the case of CG. ~40k cells were seeded on punched zylindrical cores of 8 mm in Ø and cultured on CG or NC patches for up to 7 days. The cells were either cultured as TC only, MSC only or co-cultured in a 1:1 mix on the scaffolds and on both sides of culture inserts (PET, high density pore Ø 0.4 mm, BD, Fal- con) with cell-cell contact. We monitored DNA content, GAG and HOP-content, tracked the cells using DIL and DIO fluorescent dyes (Molecular Probes, Life technologies) and confocal laser scanning and SEM microscopy as well as RT-PCR of tenocyte specific markers (i.e. col 1 and 3, TNC, TNMD, SCXA&B, and markers of dedifferentiation ACAN, col2, MMP3, MMP13). Finally, H&E stain was interpreted on cryosections and SEM images of cells on the scaffold were taken. Results: ThecLSMimagesshowedcellproliferationoverthe7dayson both matrices, however, on CG there were much fewer MSCs attached than on NC. SEM images showed a roundish chondrocyte-like pheno- type of cells on CG whereas on NC the phenotype was more teno- cyte-like (Fig. 1). Gene expression of both, MSC and TC seem to confirm a more favorable environment in 3D for both patches rather than monolayer control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To evaluate use of a surgical technique commonly used in humans for treatment of cervical spondylotic myelopathy (CSM) in dogs. DESIGN Prospective case series. ANIMALS Dogs with CSM (n=10). METHODS Dogs weighing >30 kg that had CSM at 1 vertebral articulation were eligible for inclusion. Dogs had vertebral column distraction/fusion performed using a cortical ring allograft, cancellous autograft, and a spinal locking plate. Dogs were evaluated temporally by repeat neurological examinations and by client perception of postsurgical outcome, determined by telephone interview. RESULTS Nine dogs survived the immediate postoperative period. Seven of 8 dogs had moderate to complete improvement without recurrence (mean follow-up, 2.48 years). The most common postsurgical complications were screw loosening (n=4) and plate shifting (2), neither of which required surgical revision. One dog had pseudoarthrosis that may have negatively impacted outcome. CONCLUSION Treatment of single level CSM in dogs with ring allograft and a spinal locking plate system may lead to successful outcomes. The major problems encountered with included cost of the implants and adjusting the system designed for humans to fit the vertebral column of a dog. CLINICAL RELEVANCE For dogs with CSM at a single level, the use of a spinal locking plate in combination with a cortical ring allograft can be an effective surgical treatment. Costs of the implants as well as anatomic differences in dogs make this type of surgery less appealing.