903 resultados para activity, detection, monitoring, wearable, sensors, accelerometer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research has included the efforts in designing, assembling and structurally and functionally characterizing supramolecular biofunctional architectures for optical biosensing applications. In the first part of the study, a class of interfaces based on the biotin-NeutrAvidin binding matrix for the quantitative control of enzyme surface coverage and activity was developed. Genetically modified ß-lactamase was chosen as a model enzyme and attached to five different types of NeutrAvidin-functionalized chip surfaces through a biotinylated spacer. All matrices are suitable for achieving a controlled enzyme surface density. Data obtained by SPR are in excellent agreement with those derived from optical waveguide measurements. Among the various protein-binding strategies investigated in this study, it was found that stiffness and order between alkanethiol-based SAMs and PEGylated surfaces are very important. Matrix D based on a Nb2O5 coating showed a satisfactory regeneration possibility. The surface-immobilized enzymes were found to be stable and sufficiently active enough for a catalytic activity assay. Many factors, such as the steric crowding effect of surface-attached enzymes, the electrostatic interaction between the negatively charged substrate (Nitrocefin) and the polycationic PLL-g-PEG/PEG-Biotin polymer, mass transport effect, and enzyme orientation, are shown to influence the kinetic parameters of catalytic analysis. Furthermore, a home-built Surface Plasmon Resonance Spectrometer of SPR and a commercial miniature Fiber Optic Absorbance Spectrometer (FOAS), served as a combination set-up for affinity and catalytic biosensor, respectively. The parallel measurements offer the opportunity of on-line activity detection of surface attached enzymes. The immobilized enzyme does not have to be in contact with the catalytic biosensor. The SPR chip can easily be cleaned and used for recycling. Additionally, with regard to the application of FOAS, the integrated SPR technique allows for the quantitative control of the surface density of the enzyme, which is highly relevant for the enzymatic activity. Finally, the miniaturized portable FOAS devices can easily be combined as an add-on device with many other in situ interfacial detection techniques, such as optical waveguide lightmode spectroscopy (OWLS), the quartz crystal microbalance (QCM) measurements, or impedance spectroscopy (IS). Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) allows for an absolute determination of intrinsic rate constants describing the true parameters that control interfacial hybridization. Thus it also allows for a study of the difference of the surface coupling influences between OMCVD gold particles and planar metal films presented in the second part. The multilayer growth process was found to proceed similarly to the way it occurs on planar metal substrates. In contrast to planar bulk metal surfaces, metal colloids exhibit a narrow UV-vis absorption band. This absorption band is observed if the incident photon frequency is resonant with the collective oscillation of the conduction electrons and is known as the localized surface plasmon resonance (LSPR). LSPR excitation results in extremely large molar extinction coefficients, which are due to a combination of both absorption and scattering. When considering metal-enhanced fluorescence we expect the absorption to cause quenching and the scattering to cause enhancement. Our further study will focus on the developing of a detection platform with larger gold particles, which will display a dominant scattering component and enhance the fluorescence signal. Furthermore, the results of sequence-specific detection of DNA hybridization based on OMCVD gold particles provide an excellent application potential for this kind of cheap, simple, and mild preparation protocol applied in this gold fabrication method. In the final chapter, SPFS was used for the in-depth characterizations of the conformational changes of commercial carboxymethyl dextran (CMD) substrate induced by pH and ionic strength variations were studied using surface plasmon resonance spectroscopy. The pH response of CMD is due to the changes in the electrostatics of the system between its protonated and deprotonated forms, while the ionic strength response is attributed from the charge screening effect of the cations that shield the charge of the carboxyl groups and prevent an efficient electrostatic repulsion. Additional studies were performed using SPFS with the aim of fluorophore labeling the carboxymethyl groups. CMD matrices showed typical pH and ionic strength responses, such as high pH and low ionic strength swelling. Furthermore, the effects of the surface charge and the crosslink density of the CMD matrix on the extent of stimuli responses were investigated. The swelling/collapse ratio decreased with decreasing surface concentration of the carboxyl groups and increasing crosslink density. The study of the CMD responses to external and internal variables will provide valuable background information for practical applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in biomedical signal acquisition systems for motion analysis have led to lowcost and ubiquitous wearable sensors which can be used to record movement data in different settings. This implies the potential availability of large amounts of quantitative data. It is then crucial to identify and to extract the information of clinical relevance from the large amount of available data. This quantitative and objective information can be an important aid for clinical decision making. Data mining is the process of discovering such information in databases through data processing, selection of informative data, and identification of relevant patterns. The databases considered in this thesis store motion data from wearable sensors (specifically accelerometers) and clinical information (clinical data, scores, tests). The main goal of this thesis is to develop data mining tools which can provide quantitative information to the clinician in the field of movement disorders. This thesis will focus on motor impairment in Parkinson's disease (PD). Different databases related to Parkinson subjects in different stages of the disease were considered for this thesis. Each database is characterized by the data recorded during a specific motor task performed by different groups of subjects. The data mining techniques that were used in this thesis are feature selection (a technique which was used to find relevant information and to discard useless or redundant data), classification, clustering, and regression. The aims were to identify high risk subjects for PD, characterize the differences between early PD subjects and healthy ones, characterize PD subtypes and automatically assess the severity of symptoms in the home setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Membranproteine spielen eine wichtige Rolle bei physiologischen Prozessen wie Signalweiterleitung oder Immunreaktion. Deshalb stehen sie im Fokus der pharmakologischen Wirkstoffentwicklung und es besteht großes Interesse, Membranproteinbasierte Biosensoren zu entwickeln, die sich z.B. als Screening-Plattformen eignen. Allerdings stellt die Handhabung von Membranproteinen wegen ihrer amphiphilen Struktur eine große Herausforderung dar. Membranproteine werden meist in Zellkultur oder in bakteriellen Expressionssystemen synthetisiert. Diese Verfahren liefern aber oft nur eine geringe Ausbeute und erlauben wenig Kontrolle über die Expressionsbedingungen. Als alternativer Ansatz bietet sich stattdessen die in vitro Synthese von Proteinen an, die in einer zellfreien Umgebung stattfindet. Ziel der vorliegenden Arbeit war die Etablierung eines miniaturisierten Analysesystems, das Aktivitätsmessungen an in vitro synthetisierten Ionenkanälen erlaubt. Dafür wurde ein Labon- Chip entwickelt, der elektrochemische und optische Nachweismethoden in parallelen Anätzen ermöglicht. Als amphiphile Umgebung für die Inkorporation von Membranproteinen wurden vier verschieden biomimetische Membranaufbauten hinsichtlich ihrer Dichtigkeit und ihrer Reproduzierbarkeit untersucht. Als Methode fanden insbesondere die Impedanzspektroskpie und die Oberflächenplasmonen-Resonanzspektroskopie Anwendung. Die peptide cushioned Bilyer Lipid Membranes (pcBLM) eignete sich dabei am besten für Untersuchungen an Membranproteinen. Zur Detektion der Ionenkanalaktivität wurde eine neue Messmethode etabliert, die auf der Messung der Impedanz bei fester Frequenz basiert und u.a. eine Aussage über die Änderung des Membranwiderstandes bei Aktivierung erlaubt. Am Beispiel des nicotinischen Acetylcholinrezeptors (nAchR) konnte gezeigt werden, dass sich die Aktivität von Ionenkanälen mit dem entwickelten Chip-System nachweisen ließ. Die Spezifität der Methode konnte durch verschiedene Kontrollen wie die Zugabe eines nicht-aktivierenden Liganden oder Inhibition des Rezeptors nachgewiesen werden. Weiterhin konnte die in vitro Synthese des Ionenkanals a7 nAchR durch Radioaktivmarkierung nachgewiesen werden. Die Inkorporation des Rezeptors in die biomimetischen Membranen wurde mit Immunodetektion und elektrochemischen Methoden untersucht. Es zeigte sich, dass die funktionelle Inkorporation des a7 nAchR davon abhing, welcher biomimetische Membranaufbau verwendet wurde.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il recente sviluppo commerciale di smartphone, tablet e simili dispositivi, ha portato alla ricerca di soluzioni hardware e software dotate di un alto livello di integrazione, in grado di supportare una potenza di calcolo e una versatilità di utilizzo sempre più crescenti, pur mantenendo bassi i consumi e le dimensioni dei dispositivi. Questo sviluppo ha consentito parallelamente a simili tecnologie di trovare applicazione in tanti altri settori, tra i quali quello biomedicale. Il lavoro esposto in questa tesi si inserisce nel contesto appena descritto e, in particolare, consiste nello sviluppo di un sistema WBAN ideato per garantire maggiore flessibilità, controllo e personalizzazione nella terapia riabilitativa dei pazienti affetti da Morbo di Parkinson. In questo campo è stata dimostrata l'efficacia, in termini di miglioramento delle condizioni di vita dell'individuo, dell'esercizio fisico e in particolare di una serie di fisioterapie riabilitative specifiche. Tuttavia manca ancora uno strumento in grado di garantire più indipendenza, continuità e controllo,per le persone affette da MP, durante l'esecuzione di questi esercizi; senza che sia strettamente necessario l'intervento di personale specializzato per ogni seduta fisioterapeutica. Inoltre manca un sistema che possa essere comodamente trasportato dal paziente nelle attività di tutti i giorni e che consenta di registrare e trasmettere eventi particolari legati alla patologia, come blocchi motori e cadute accidentali. Il presente lavoro di tesi tratta della realizzazione di un Firmware per la gestione di un Nodo Centrale che funge da master in una rete WBAN a tre nodi. L'obbiettivo è quello di integrare in tale firmware le funzioni di acquisizione dati dai sensori on-board, comunicazione tra i nodi della rete e gestione delle periferiche hardware secondarie; in particolare per lo sviluppo è stato usato un Sistema Operativo Real-Time (RTOS) del quale sono esposti vantaggi e svantaggi dell’utilizzo.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabajo de Tesis ha abordado el objetivo de dar robustez y mejorar la Detección de Actividad de Voz en entornos acústicos adversos con el fin de favorecer el comportamiento de muchas aplicaciones vocales, por ejemplo aplicaciones de telefonía basadas en reconocimiento automático de voz, aplicaciones en sistemas de transcripción automática, aplicaciones en sistemas multicanal, etc. En especial, aunque se han tenido en cuenta todos los tipos de ruido, se muestra especial interés en el estudio de las voces de fondo, principal fuente de error de la mayoría de los Detectores de Actividad en la actualidad. Las tareas llevadas a cabo poseen como punto de partida un Detector de Actividad basado en Modelos Ocultos de Markov, cuyo vector de características contiene dos componentes: la energía normalizada y la variación de la energía. Las aportaciones fundamentales de esta Tesis son las siguientes: 1) ampliación del vector de características de partida dotándole así de información espectral, 2) ajuste de los Modelos Ocultos de Markov al entorno y estudio de diferentes topologías y, finalmente, 3) estudio e inclusión de nuevas características, distintas de las del punto 1, para filtrar los pulsos de pronunciaciones que proceden de las voces de fondo. Los resultados de detección, teniendo en cuenta los tres puntos anteriores, muestran con creces los avances realizados y son significativamente mejores que los resultados obtenidos, bajo las mismas condiciones, con otros detectores de actividad de referencia. This work has been focused on improving the robustness at Voice Activity Detection in adverse acoustic environments in order to enhance the behavior of many vocal applications, for example telephony applications based on automatic speech recognition, automatic transcription applications, multichannel systems applications, and so on. In particular, though all types of noise have taken into account, this research has special interest in the study of pronunciations coming from far-field speakers, the main error source of most activity detectors today. The tasks carried out have, as starting point, a Hidden Markov Models Voice Activity Detector which a feature vector containing two components: normalized energy and delta energy. The key points of this Thesis are the following: 1) feature vector extension providing spectral information, 2) Hidden Markov Models adjustment to environment and study of different Hidden Markov Model topologies and, finally, 3) study and inclusion of new features, different from point 1, to reject the pronunciations coming from far-field speakers. Detection results, taking into account the above three points, show the advantages of using this method and are significantly better than the results obtained under the same conditions by other well-known voice activity detectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate-specific antigen (PSA) is important in tumour detection, monitoring disease progression and tumour recurrence. however, PSA is not a cancerspecific marker as levels can also be elevated in benign prostatic disease. A number of different mRNA transcripts of PSA have also been identified in prostatic tissue, but have not been fully characterized (PSA 424, PSA 525, Schulz transcript). Tissue specimens from transurethral resection of the prostate (TURP) or radical prostatectomy were obtained from 17 men with BPH and 15 men with prostate cancer. Total RNA was extracted, and reverse-transcriptionpolymerase chain reaction (RT-PCR) and Southern analysis carried out using transcript-specific primers and probes to determine which mRNA PSA transcripts were expressed. Real-time PCR was performed to determine transcript levels between the two groups using transcript-specific primers and SYBR green fluorescence. Values obtained were normalized to a standard housekeeping gene, B2-microglobulin. Transcripts amplified by RT-PCR and real-time PCR were confirmed by DNA sequencing. Our results show that the transcripts were present in some, but not all, BPH and cancer samples indicating that they are not specific to either BPH or cancer. Analysis of real-time PCR normalized values using a Student’s t -test, shows that there is a significant difference between the two groups for PSA 424, but not wild-type PSA, PSA 525 or the Schulz transcript. Although a larger cohort of samples is needed to further confirm these results, these findings suggest that mRNA levels of PSA 424 may have some utility as a diagnostic or prognostic marker in prostate cancer detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The integration of quantitative data from movement analysis technologies is reshaping the analysis of athletes’ performances and injury mitigation, e.g., anterior cruciate ligament (ACL) rupture. Most of the movement assessments are performed in laboratory environments. Recent progress provides the chance to shift the paradigm to a more ecological approach with sport-specific elements and a closer examination of “real” movement patterns associated with performance and (ACL) injury risk. The present PhD thesis aimed at investigating the on-field motion patterns related to performance and injury prevention in young football players. The objectives of the thesis were: (I) in-lab measures of high-dynamics movements were used to validate wearable inertial sensors technology; (II) in-laboratory and on-field agility movement tasks were compared to inspect the effect of football-specific environment; (III) on-field analysis was conducted to challenge wearable sensors technology in the assessment of dangerous movement patterns towards the ACL rupture; (IV) an overview of technologies that could shape present and future assessment of ACL injury risk in daily practice was presented. The validity of wearables in the assessment of high-dynamics movements was confirmed. Relevant differences emerged between the movements performed in a laboratory setting and on the football pitch, supporting the inclusion of an ecological dynamics approach in preventive protocols. The on-field analysis of football-specific movement tasks demonstrated good reliability of wearable sensors and the presence of residual dangerous patterns in the injured players. A tool to inspect at-risk movement patterns on the field through objective measurements was presented. It discussed how potential alternatives to wearable inertial sensors embrace artificial intelligence and closer collaboration between clinical and technical expertise. The present thesis was meant to contribute to setting the basis for data-driven prevention protocols. A deeper comprehension of injury-related principles and counteractions will contribute to preserving athletes’ careers and health over time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Stress is a phenomenon that on some level affects everyone’s lives on a daily basis. The autonomic nervous system controls the varying levels of stress at any given time. The responses of the autonomic nervous system adjust the body to cope with changing external and internal conditions. During high-stress situations the body is forced into a state of heightened alertness, which passes when the stressor is removed. The stressor can be any external or internal event that causes the body to respond. Stress is a very versatile phenomenon that can be both a cause and an indicator of other medical conditions, for example cardiovascular disease. Stress detection can therefore be helpful in identifying these conditions and monitoring the overall emotional state of a person. Electrodermal activity (EDA) is one of the most easily implemented ways to monitor the activity of the autonomic nervous system. EDA describes changes occurring in the various electrical properties of the skin, including skin conductivity and resistance. Increased emotional sweating has been proven to be one possible indication of stress. On the surface of the skin, increased sweating translates to increased skin conductivity, which can be observed through EDA measurements. This makes electrodermal activity a very useful tool in a wide range of applications where it is desirable to observe changes in a person’s stress level. EDA can be recorded by using specialized body sensors placed on specific locations on the body. Most commonly used recording sites are the palms of the hands due to the high sweat gland density on those areas. Measurement is done using at least two electrodes attached to the skin, and recording the electrical conductance between them. This thesis implements a prototype of a wireless EDA measurement system. The feasibility of the prototype is also verified with a small group of test subjects. EDA was recorded from the subjects while they were playing a game of Tetris. The goal was to observe variations in the measured EDA that would indicate changes in the subjects’ stress levels during the game. The analysis of the obtained measurement results confirmed the connection between stress and recorded EDA. During the game, random occurrences of lowered skin resistance were clearly observable, which indicates points in the game where the player felt more anxious. A wireless measurement system has the potential of offering more flexible and comfortable long-term measuring of EDA, and could be utilized in a wide range of applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Various fall-detection solutions have been previously proposed to create a reliable surveillance system for elderly people with high requirements on accuracy, sensitivity and specificity. In this paper, an enhanced fall detection system is proposed for elderly person monitoring that is based on smart sensors worn on the body and operating through consumer home networks. With treble thresholds, accidental falls can be detected in the home healthcare environment. By utilizing information gathered from an accelerometer, cardiotachometer and smart sensors, the impacts of falls can be logged and distinguished from normal daily activities. The proposed system has been deployed in a prototype system as detailed in this paper. From a test group of 30 healthy participants, it was found that the proposed fall detection system can achieve a high detection accuracy of 97.5%, while the sensitivity and specificity are 96.8% and 98.1% respectively. Therefore, this system can reliably be developed and deployed into a consumer product for use as an elderly person monitoring device with high accuracy and a low false positive rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tracking activities during daily life and assessing movement parameters is essential for complementing the information gathered in confined environments such as clinical and physical activity laboratories for the assessment of mobility. Inertial measurement units (IMUs) are used as to monitor the motion of human movement for prolonged periods of time and without space limitations. The focus in this study was to provide a robust, low-cost and an unobtrusive solution for evaluating human motion using a single IMU. First part of the study focused on monitoring and classification of the daily life activities. A simple method that analyses the variations in signal was developed to distinguish two types of activity intervals: active and inactive. Neural classifier was used to classify active intervals; the angle with respect to gravity was used to classify inactive intervals. Second part of the study focused on extraction of gait parameters using a single inertial measurement unit (IMU) attached to the pelvis. Two complementary methods were proposed for gait parameters estimation. First method was a wavelet based method developed for the estimation of gait events. Second method was developed for estimating step and stride length during level walking using the estimations of the previous method. A special integration algorithm was extended to operate on each gait cycle using a specially designed Kalman filter. The developed methods were also applied on various scenarios. Activity monitoring method was used in a PRIN’07 project to assess the mobility levels of individuals living in a urban area. The same method was applied on volleyball players to analyze the fitness levels of them by monitoring their daily life activities. The methods proposed in these studies provided a simple, unobtrusive and low-cost solution for monitoring and assessing activities outside of controlled environments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this elaborate, a textile-based Organic Electrochemical Transistor (OECT) was first developed for the determination of uric acid in wound exudate based on the conductive polymer poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), which was then coupled to an electrochemically gated textile transistor consisting of a composite of iridium oxide particles and PEDOT:PSS for pH monitoring in wound exudate. In that way a sensor for multiparameter monitoring of wound health status was assembled, including the ability to differentiate between a wet-dry status of the smart bandage by implementing impedance measurements exploiting the OECT architecture. Afterwards, for both wound management as well as generic health status tracking applications, a glass-based calcium sensor was developed employing polymeric ion-selective membranes on a novel architecture inspired by the Wrighton OECT configuration, which was later converted to a Proof-of-Concept textile prototype for wearable applications. Lastly, in collaboration with the King Abdullah University of Science and Technology (KAUST, Thuwal, Saudi Arabia) under the supervision of Prof. Sahika Inal, different types of ion-selective thiophene-based monomers were used to develop ion-selective conductive polymers to detect sodium ion by different methods, involving standard potentiometry and OECT-based approaches. The textile OECTs for uric acid detection performances were optimized by investigating the geometry effect on the instrumental response and the properties of the different textile materials involved in their production, with a special focus on the final application that implies the operativity in flow conditions to simulate the wound environment. The same testing route was followed for the multiparameter sensor and the calcium sensor prototype, with a particular care towards the ion-selective membrane composition and electrode conditioning protocol optimization. The sodium-selective polymer electrosynthesis was optimized in non-aqueous environments and was characterized by means of potentiostatic and potentiodynamic techniques coupled with Quartz Crystal Microbalance and spectrophotometric measurements.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A single reaction interface flow analysis (SIFA) system for the monitoring of mannitol in pharmaceutical formulations and human urine is presented. The developed approach takes advantage of the mannitol scavenger aptitude to inhibit the chemiluminescent reaction between luminol and myoglobin in the absence of H(2)O(2). The SIFA system facilitated the fully automation of the developed methodology, allowing the in-line reproducible handling of chemical species with a very short lifetime as is the case of the hydroxyl radical generated in the abovementioned luminol/myoglobin reaction. The proposed methodology allowed the determination of mannitol concentrations between 25 mmol L(-1) and 1 mol L(-1), with good precision (R.S.D. < 4.7%, n = 3) and a sampling frequency of about 60 h(-1). The procedure was applied to the determination of mannitol in pharmaceuticals and in human urine samples Without any pretreatment process. The results obtained for pharmaceutical formulations were statistically comparable to those provided by the reference method (R.D. < 4.6%); recoveries values obtained in the analysis of spiked urine samples (between 94.9 and 105.3% of the added amount) were also satisfactory. (C) 2008 Elsevier B.V. All rights reserved.