989 resultados para WHITE LIGHT


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose of reviewIn bladder cancer, discrimination between benign and malignant tissue may remain tricky with current endoscopic tools. On the basis of our recent experience with high-magnification cystoscopy, compared with other tools such as optical coherence tomography or confocal laser endomicroscopy, it is suggested here that this discrimination may well be feasible endoscopically. The clinical potential of these systems that are being developed as complementary tools to the current endoscopic equipment is reviewed.Recent findingsAt present, white-light cystoscopy, either assisted by fluorescence cystoscopy or narrow-band imaging, is proposed for the global cystoscopic examination of bladder cancer patients. Both techniques compete to help to reduce the recurrence rate by improving exophytic tumor detection, and the extent of carcinoma in situ and high-grade dysplasia. All of which are important prognosis factors for disease progression. In addition, recent findings on neoangiogenesis that accompanies early stage bladder cancer show that this may also be an important observable switch in bladder cancerogenesis, as it is found very early in tumor development. The high magnification cystoscopy as a complementary tool to fluorescence cystoscopy allows classification of the vessel patterns on fluorescence positive sites, and thus facilitates the discrimination between cancerous and noncancerous lesions. This information may be useful to reduce the false positive rate of fluorescence cystoscopy.SummaryEmerging technologies aiming at a real-time in-situ discrimination between benign and malignant tissue during endoscopic bladder exploration is a promising development for the monitoring of bladder cancer patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Résumé Objectifs : La thérapie photodynamique a pour but la destruction sélective du tissu néoplasique par interaction de lumière, d'oxygène et d'une substance photosensibilisatrice (la Protoporphyrine IX dans notre étude). Malgré une accumulation sélective du photosensibilisateur dans le tissu tumoral, la thérapie photodynamique du carcinome urothélial de la vessie peut endommager les cellules normales de l'épithélium urinaire. La prévention de ces lésions est importante pour la régénération de la muqueuse. Notre étude sur un modèle in vitro d'urothélium porcin étudie l'influence de la concentration du photosensibilisateur, des paramètres d'irradiation et de la production d'intermédiaires réactifs de l'oxygène (ROS) sur les effets photodynamique. Le but était de déterminer les conditions seuil pour épargner l'urothélium sain. Méthode: Dans une chambre de culture transparente à deux compartiments, des muqueuses vésicales de porc maintenues en vie ont été incubées avec une solution d'hexyl-aminolévulinate (HAL), le précurseur de la Protoporphyrine IX. Ces muqueuses ont ensuite été irradiées avec des doses lumineuses croissantes en lumière bleue et en lumière blanche, et les altérations cellulaires ont été évaluées par microscopie électronique à balayage et par un colorant fluorescent, le Sytox green. Nous avons également évalué la production d'intermédiaires réactifs de l'oxygène parla mesure de la fluorescence intracellulaire de Rhodamine 123 (R123), produit de l'oxydation de la Dihydrorhodamine 123 (DHR123) non fluorescente. Ces valeurs ont été corrélées avec celles du photo blanchiment de la PAIX. Résultats : Le taux de mortalité cellulaire était dépendant de la concentration de PAIX. Après 3 heures d'incubation, la valeur seuil de dose lumineuse pour la lumière bleu était de 0.15 et 0.75 J/cm2 (irradiance 30 et 75 mW/cm2, respectivement) et pour la lumière blanche de 0.55 J/cm2 (irradiante 30 mW/cm2). Le taux de photo blanchiment était inversement proportionnel à l'irradiante. Le système de détection des intermédiaires réactifs de l'oxygène DHR123/R123 a démontré une bonne corrélation avec les valeurs seuil pour toutes les conditions d'irradiation utilisées. Conclusions : Nous avons déterminé les doses lumineuses permettant d'épargner 50% des cellules urothéliales saines. L'utilisation d'une faible irradiante associée à des systèmes permettant de mesurer la production d'intermédiaires réactifs de l'oxygène dans les tissus irradiés pourrait améliorer la dosimétrie in vivo et l'efficacité de la thérapie photodynamique. Abstract Background and Objectives: Photodynamic therapy of superficial bladder cancer may cause damages to the normal surrounding bladder wall. Prevention of these is important for bladder healing. We studied the influence of photosensitizes concentration, irradiation parameters and production of reactive oxygen species (ROS) on the photodynamically induced damage in the porcine urothelium in vitro. The aim was to determine the threshold conditions for the cell survival. Methods: Living porcine bladder mucosae were incubated with solution of hexylester of 5-aminolevulinic acid (HAL). The mucosae were irradiated with increasing doses and cell alterations were evaluated by scanning electron microscopy and by Sytox green fluorescence. The urothelial survival score was correlated with Protoporphyrin IX (PpIX) photobleaching and intracellular fluorescence of Rhodamine 123 reflecting the ROS production. Results: The mortality ratio was dependent on PpIX concentration. After 3 hours of incubation, the threshold radiant exposures for blue light were 0.15 and 0.75 J/cm2 (irradiance 30 and 75 mW/cm2, respectively) and for white light 0.55 J/cm2 (irradiance 30 mW/cm2). Photobleaching rate increased with decreasing irradiance. Interestingly, the DHR123/R123 reporter system correlated well with the threshold exposures under all conditions used. Conclusions: we have determined radiant exposures sparing half of normal urothelial cells. We propose that the use of low irradiance combined with systems reporting the ROS production in the irradiated tissue could improve the in vivo dosimetry and optimize the PDT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The phytochrome-interacting factor PIF3 has been proposed to act as a positive regulator of chloroplast development. Here, we show that the pif3 mutant has a phenotype that is similar to the pif1 mutant, lacking the repressor of chloroplast development PIF1, and that a pif1pif3 double mutant has an additive phenotype in all respects. The pif mutants showed elevated protochlorophyllide levels in the dark, and etioplasts of pif mutants contained smaller prolamellar bodies and more prothylakoid membranes than corresponding wild-type seedlings, similar to previous reports of constitutive photomorphogenic mutants. Consistent with this observation, pif1, pif3, and pif1pif3 showed reduced hypocotyl elongation and increased cotyledon opening in the dark. Transfer of 4-d-old dark-grown seedlings to white light resulted in more chlorophyll synthesis in pif mutants over the first 2 h, and analysis of gene expression in dark-grown pif mutants indicated that key tetrapyrrole regulatory genes such as HEMA1 encoding the rate-limiting step in tetrapyrrole synthesis were already elevated 2 d after germination. Circadian regulation of HEMA1 in the dark also showed reduced amplitude and a shorter, variable period in the pif mutants, whereas expression of the core clock components TOC1, CCA1, and LHY was largely unaffected. Expression of both PIF1 and PIF3 was circadian regulated in dark-grown seedlings. PIF1 and PIF3 are proposed to be negative regulators that function to integrate light and circadian control in the regulation of chloroplast development.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective This paper reviews the development and clinical validation of photodynamic diagnosis (PDD) of bladder cancer. Methods The authors reviewed the literature on the development of PDD, in particular the evidence for the clinical efficacy of hexaminolevulinate PDD in the diagnosis of bladder cancer. Results After initial work on ultraviolet cystoscopy following oral tetracycline, the focus of PDD research shifted to the use of synthetic porphyrins. First, the prodrug delta-aminolevulinic acid (ALA) was shown to cause a transient but significant accumulation of protoporphyrin IX (PpIX) in malignant or premalignant bladder tissue. Excitation by blue light leads to PpIX fluorescence (red), which distinguishes tumour from normal tissue (blue). Hexaminolevulinate (HAL, Hexvix), an ester of ALA, was then developed and has greater bioavailability and stability than the parent compound. It has been approved for clinical use in the diagnosis of bladder cancer. Clinical studies have shown that HAL PDD detects tumours, including carcinoma in situ (CIS), that are missed by conventional white-light cystoscopy. Conclusions HAL PDD is a valuable aid to the detection of bladder tumours, including CIS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

White-light cystoscopy and cytology are the standard tools to diagnose bladder cancer. White-light cystoscopy is excellent to detect macroscopic exophytic tumors, but its sensitivity is poor for flat tumors such as carcinoma in situ. Use of fluorescence cystoscopy during transurethral bladder resection improve tumor detection, particulary for carcinoma in situ. Fluorescence cystoscopy reduce residual tumor rate, especially for voluminous and multifocal tumors with consecutive lower recurrence. Fluorescence is now recommended to diagnose and treat bladder cancer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Heterogeneous results of single studies with photodynamic diagnosis (PDD) in bladder cancer have been reported. A metaanalysis of prospective studies has now been performed. Material and Methods: The effect of PDD in addition to WLC on a) the diagnosis and b) the therapeutic outcome of primary or recurrent non-muscle invasive bladder cancer (NMIBC) investigated by cystoscopy or transurethral resection was analysed. An electronic database search was performed. Trials were included if they prospectively compared WLC with PDD in bladder cancer. Primary endpoints were additional detection rate, residual tumour at second resection and recurrence-free survival. Results: Significantly more tumour-positive patients were detected with PDD in all patients with non-muscle invasive tumours (= 20%) [95% confidence interval (CI): 8 to 35%] and in CIS patients (= 39%) (CI: 23 to 57%). Residual tumour was significantly less often found after PDD (odds ratio 0.28, CI: 0.15 to 0.52, p<0.0001). Recurrence-free survival was significantly higher at 12 and 24months in the PDD groups than in WLC only groups. Conclusions: More bladder tumour-positive patients are detected by PDD. Best results were found in CIS patients. Diagnosis with PDD results in a more complete resection and a longer recurrence-free survival.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONTEXT: Controversy exists regarding the therapeutic benefit and cost effectiveness of photodynamic diagnosis (PDD) with 5-aminolevulinic acid (5-ALA) or hexyl aminolevulinate (HAL) in addition to white-light cystoscopy (WLC) in the management of non-muscle-invasive bladder cancer (NMIBC). OBJECTIVE: To systematically evaluate evidence regarding the therapeutic benefits and economic considerations of PDD in NMIBC detection and treatment. EVIDENCE ACQUISITION: We performed a critical review of PubMed/Medline, Embase, and the Cochrane Library in October 2012 according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Identified reports were reviewed according to the Consolidated Standards of Reporting Trials (CONSORT) and Standards for the Reporting of Diagnostic Accuracy Studies (STARD) criteria. Forty-four publications were selected for inclusion in this analysis. EVIDENCE SYNTHESIS: Included reports used 5-ALA (in 26 studies), HAL (15 studies), or both (three studies) as photosensitising agents. PDD increased the detection of both papillary tumours (by 7-29%) and flat carcinoma in situ (CIS; by 25-30%) and reduced the rate of residual tumours after transurethral resection of bladder tumour (TURBT; by an average of 20%) compared to WLC alone. Superior recurrence-free survival (RFS) rates and prolonged RFS intervals were reported for PDD, compared to WLC in most studies. PDD did not appear to reduce disease progression. Our findings are limited by tumour heterogeneity and a lack of NMIBC risk stratification in many reports or adjustment for intravesical therapy use in most studies. Although cost effectiveness has been demonstrated for 5-ALA, it has not been studied for HAL. CONCLUSIONS: Moderately strong evidence exists that PDD improves tumour detection and reduces residual disease after TURBT compared with WLC. This has been shown to improve RFS but not progression to more advanced disease. Further work to evaluate cost effectiveness of PDD is required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Studies on hexaminolevulinate (HAL) cystoscopy report improved detection of bladder tumours. However, recent meta-analyses report conflicting effects on recurrence. OBJECTIVE: To assess available clinical data for blue light (BL) HAL cystoscopy on the detection of Ta/T1 and carcinoma in situ (CIS) tumours, and on tumour recurrence. DESIGN, SETTING, AND PARTICIPANTS: This meta-analysis reviewed raw data from prospective studies on 1345 patients with known or suspected non-muscle-invasive bladder cancer (NMIBC). INTERVENTION: A single application of HAL cystoscopy was used as an adjunct to white light (WL) cystoscopy. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: We studied the detection of NMIBC (intention to treat [ITT]: n=831; six studies) and recurrence (per protocol: n=634; three studies) up to 1 yr. DerSimonian and Laird's random-effects model was used to obtain pooled relative risks (RRs) and associated 95% confidence intervals (CIs) for outcomes for detection. RESULTS AND LIMITATIONS: BL cystoscopy detected significantly more Ta tumours (14.7%; p<0.001; odds ratio [OR]: 4.898; 95% CI, 1.937-12.390) and CIS lesions (40.8%; p<0.001; OR: 12.372; 95% CI, 6.343-24.133) than WL. There were 24.9% patients with at least one additional Ta/T1 tumour seen with BL (p<0.001), significant also in patients with primary (20.7%; p<0.001) and recurrent cancer (27.7%; p<0.001), and in patients at high risk (27.0%; p<0.001) and intermediate risk (35.7%; p=0.004). In 26.7% of patients, CIS was detected only by BL (p<0.001) and was also significant in patients with primary (28.0%; p<0.001) and recurrent cancer (25.0%; p<0.001). Recurrence rates up to 12 mo were significantly lower overall with BL, 34.5% versus 45.4% (p=0.006; RR: 0.761 [0.627-0.924]), and lower in patients with T1 or CIS (p=0.052; RR: 0.696 [0.482-1.003]), Ta (p=0.040; RR: 0.804 [0.653-0.991]), and in high-risk (p=0.050) and low-risk (p=0.029) subgroups. Some subgroups had too few patients to allow statistically meaningful analysis. Heterogeneity was minimised by the statistical analysis method used. CONCLUSIONS: This meta-analysis confirms that HAL BL cystoscopy significantly improves the detection of bladder tumours leading to a reduction of recurrence at 9-12 mo. The benefit is independent of the level of risk and is evident in patients with Ta, T1, CIS, primary, and recurrent cancer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32/33 (97%) cancerous biopsies and rejected 17/20 (85%) noncancerous lesions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article aims at evaluating the effects of different packaging and varied storage temperatures on the germination potential of seeds of Campomanesia adamantium Camb. O. Berg. The seeds were packaged in glass, aluminum foil and plastic containers, or maintained inside intact fruits at 5, 10 and 15 ºC during 0, 7, 14 and 21 days. After these periods the seeds were sown in Germitest® germination paper and maintained in incubation chambers at 25 ºC under constant white light for 42 days. Seed moisture contents were evaluated both before and after storage, as well as germination percentages, germination speed index, root and aerial portion of seedlings lengths, and total dry weights. All possible combinations of packing materials, temperatures and storage times were tested, with four repetitions of 25 seeds for each treatment. C. adamantium seeds showed initial water contents of 31.5%. Glass and aluminum packaging were efficient at maintaining the water content of the seeds, and provided greater germination speed index than the other packaging materials. Germination percentages, seedlings lengths and dry weights did not vary among the different temperatures tested. C. adamantium seeds can be stored for up to 21 days at temperatures between 5 and 15 ºC without altering their physiological quality. In terms of cost-benefit efficiencies, these seeds can be stored without significant damage for 21 days while still inside the fruits at temperatures of 5, 10 or 15 ºC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Luonnonvarojen ehtyminen ja ympäristön saastuminen on luonut kysyntää uusille, energiaa säästäville ja ympäristöystävällisille teknologioille. Valaistuksessa tällainen teknologia on led-tekniikka. Led-tekniikalla on useita etuja verrattuna kilpaileviin tekniikoihin kuten pitkä elinikä, ympäristöystävällisyys ja mekaaninen kestävyys. Ledejä käytetään nykyään laajalti erilaisissa erikoissovelluksissa, erityisesti jos vaatimuksena on valon värillisyys. Näihin päiviin asti ledien hinta ja heikko valontuotto ovat rajoittaneet led-valaisimien yleistymistä hehkulamppujen ja muiden valaisintyyppien korvaajina. Tekniikan nopea kehittyminen on tehnyt led-tekniikasta varteenotettavan vaihtoehdon myös yleisvalaistukseen. Uusimpien valkoisten ledien valotehokkuus on 2 - 5 -kertainen hehkulamppuun verrattuna. Led-tekniikassa on vielä paljon käyttämätöntä potentiaalia, tulevaisuudessa päästäneen 10 - 15 -kertaiseen valotehokkuuteen hehkulamppuun verrattuna. Työssä suunnitellaan mikrokontrolleripohjainen ohjausjärjestelmä valkoista valoa tuottavalle led-valaisimelle, jonka värisävyä ja kirkkautta käyttäjä voi säätää. Valkoinen valo synnytetään sekoittamalla neljän erivärisen led-rivin valoa. Mikrokontrolleri ohjaa kutakin led-riviä väriensekoitusteoriaan perustuen. Mikrokontrolleriohjaus huomioi myös ledien optisten ominaisuuksien muutokset lämpötilan suhteen. Mikrokontrolleriohjauksen suorituskyky todetaan käytännön mittauksilla.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chlorinated polymers (PVC, PVDC and E-CTFE) were irradiated with white light produced at the Brazilian Synchrotron Light Source (LNLS). The emitted gases were analyzed by mass spectrometry. The spectra were dominated by peaks related to hydrochloric acid, HCl, and chlorine (35Cl). The measured HCl intensity is used to evaluate the sensitivity of the polymers over a broad energy range. PVDC showed the greatest light sensitivity as compared to PVC and E-CTFE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Zn-TiO2nanocomposite films were prepared by electrodeposition, using an acidic zinc sulphate solution with TiO2 nanoparticles in suspension. The as-deposited samples have been heated in air at 450 ºC for 6 h. The XRD and SEM analyses pointed out to the metal matrix conversion from Zn to ZnO and a rich morphology of needles-shaped grains. These materials were used on the photoelectrochemical degradation of AO7, which was efficiently degraded, with 40% of color removal, after 2 h period at 1.0 V, under white light irradiation. The apparent first order rate constant of the photoelectrodegradation reaction was 4.12 x 10-3 min-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We tested the influence of the aril on seed germination in controlled conditions and on the removal of M. champaca seeds in natural environment. Germination assays were kept at 25 ± 2 °C under continuous white light. Removal experiments were carried out in three "old" (39 to 62-years old) and three "new" (15-years old) eucalypt stands in Horto Florestal Navarro de Andrade, Rio Claro, SP. The results show that the aril inhibits the germination and the seeds exhibit a positively photoblastic reaction. We found higher seed removal in old eucalypt stands than the new ones, probably due to the higher density of rodents in the old stands. In the new stands, we found higher seed removal of arillated seeds by ants. Ants are important to remove the aril of seeds dropped by birds, not only enhancing seed germination but also preventing seed predation by rodents.