962 resultados para Vacuum-tubes.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of drying trials show that vacuum drying produces material of the same or better quality than is currently being produced by conventional methods within 41 to 66 % of the drying time, depending on the species. Economic analysis indicates positive or negative results depending on the species and the size of drying operation. Definite economic benefits exist by vacuum drying over conventional drying for all operation sizes, in terms of drying quality, time and economic viability, for E. marginata and E. pilularis. The same applies for vacuum drying C. citriodora and E. obliqua in larger drying operations (kiln capacity 50 m3 or above), but not for smaller operations at this stage. Further schedule refinement has the ability to reduce drying times further and may improve the vacuum drying viability of the latter species in smaller operations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An earlier superfluid aether model pairing fermionic and antifermionic fields is invoked to explain Rauch's time dependent neutron interference results which now suggest that microobjects are waves and particles simultaneously. The covariant superfluid provides a medium which carries real Einstein-de Broglie “pilot” waves. Further consequences are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experimental results of delay time of a vacuum gap triggered by an exploding wire plasma have been reported. It consists of explosion delay time and propagation delay time. The explosion delay time has been found to be dependent on the parameters of the exploding wire and the exploding wire circuit and is independent of vacuum gap configuration. The propagation delay time depends on the properties of the exploding wire plasma and vacuum gap parameters such as the number of injection slots, gap spacing, gap polarity, etc. In the absence of prebreakdown current in the vacuum gap, the breakdown can be initiated only after the plasma completely bridges the gap spacing. Under this specific condition, it has been shown that the delay time data can be used to calculate the plasma velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulsatile flow of an incompressible viscous fluid in a cylindrical tube of varying cross section is investigated for small Reynolds numbers. The solutions consist of a stedy and an oscillatory part. The shear stress distribution on the wall is evaluated and discussed in detail for special geometries like tapered tubes, locally constricted tubes and peristaltic tubes. The existence of separation in the flow field is noticed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The self-triggering action of the TVG under DC conditions using the same power source as the main circuit is described. Because of the low impedance of the power source compared with the thyratron pulse generator, the TVG can be triggered with voltages as low as 85 V. It is found that circuit conditions influence the minimum stable arc currents that can be sustained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Explosive driven micro blast waves are generated in the laboratory using NONEL tubes. The explosive mixture coated to the inner walls of the plastic Nonel tube comprises of HMX and Aluminum ( 18mg/m). The detonation is triggered electrically to generate micro blast waves from the open end of the tube. Flow visualization and over pressure measurements have been carried out to understand the propagation dynamics of these micro-blast waves in both confined and unconfined domains. The classical cubic root law used for large scale blast correlation appears to hold good even for these micro-blasts generated in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transport of live fish is a crucial step to establish fish culture in captivity, and is especially challenging for species that have not been commonly cultured before, therefore transport and handling methods need to be optimized and tailored. This study describes the use of tuna tubes for small-scale transport of medium-sized pelagic fish from the Scombridae family. Tuna tubes are an array of vertical tubes that hold the fish, while fresh seawater is pumped up the tubes and through the fish mouth and gills, providing oxygen and removing wastes. In this study, 19 fish were captured using rod and line and 42% of the captured fish were transported alive in the custom-designed tuna tubes to an on-shore holding tank: five mackerel tuna (Euthynnus affinis) and three leaping bonito (Cybiosarda elegans). Out of these, just three (15.8% of total fish) acclimatized to the tank's condition. Based on these results, we discuss an improved design of the tuna tubes that has the potential to increase survival rates and enable a simple and low cost method of transporting of live pelagic fish.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The propagation characteristics of a visco-elastic fluid in a distensible tube tube are studied. The linear visco-elastic nature of the fluid is described by a complex coefficient of viscosity η*. The equation of motion of the vessel wall takes into account the pulsatile nature of the wall. Results are presented for wave propagation velocity, the resistance and the reactance of the fluid and the wall impedance. It is seen that the visco-elastic influence is significant for high values of the frequency of oscillation in various arterial vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple triggered vacuum gap has previously been described by the authors in this journal (see ibid., vol.5, 415, 1972). Further studies have resulted in improvement of the performance with regard to sensitivity and consistency of the trigger characteristics and immunity from bridging due to metal particles eroded from the arc. The earlier design suffered from rather frequent bridging of the auxiliary gap and showed rather wide scatter in its trigger characteristics. In the present design thermally stable materials like fused quartz, machinable ceramic 'Supramica 500' (Mycalex Corporation of America), lead titanate, barium titanate (LCC HTD) and silicon carbide have been used to insulate the trigger electrode from the cathode. Consistent triggerings free from bridging, at relatively low voltages of 200-400 V have been obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flow of single large liquid bubbles under gravity in closed tubes is studied here for the case when the liquid bubble exhibits micropolar behaviour. The film thickness, velocity profile in the bubble and film, and nonNewtonian effects are studied and compared with those for the correspondingNewtonian fluid. The investigation is restricted to the case where the bubble length is far greater than the tube radius.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Firing delays of a simple triggered vacuum gap are reported in this paper. The effects of insulating materials in the auxiliary gap, auxiliary gap current, main gap current and electrode separation on the delay have been investigated. The presence of insulating material in the auxiliary gap having low auxiliary gap resistance appears to exhibit large delay. Delay decreases considerably with increase of current in the auxiliary and the main gaps, but it increases with increase of electrode separation. The scatter in the delay is less than 25 ps and 500 ps with supramica (Mycalex Corporation of America) and silicon carbide respectively at lower values of auxiliary gap current and it becomes negligible for supramica at auxiliary gap currents greater than 6A. This investigation appears to indicate that the simple device can be used as a fast switch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relative abundance distributions of multiply-charged ionic species have been measured for the RF spark and vacuum vibrator are ion sources, for a number of elements. An attempt has been made to explain the observed charge state distribution on the basis of models for the arc and spark plasma. The difficulties in the way of explaining the observed charge state distributions, using the LTE model with Saha distribution as well as the corona model, are pointed out. The distribution can be explained by a diffusion-dominated plasma model with known or calculated values for ionization cross-sections, the single impact model being suitable for the RF spark and the multiple impact model for the vibrator arc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-voltage and high-current switching delay characteristics of a simple triggered vacuum gap (TVG) are described using lead zirconate titanate as the dielectric material in the auxiliary gap. This TVG has superior performance at high currents (up to 14 kA was studied) with regard to delay, reliable firing and extended life as compared to the one using either supramica or silicon carbide. The total delay consists of three intervals: to break down the auxiliary gap, to propagate the trigger plasma and to break down the main gap. The data on the influence of the various parameters like the trigger voltage, current, energy and the main circuit energy are given. It has been found that the delay due to the first two intervals is small compared to the third.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of inviscid incompressible flow in a tube of sinusoidally perturbed circular cross section with wall injection has been made. The velocity and pressure fields have been obtained. Measurements of axial velocity profiles and pressure distribution have been made in a simulated star shaped tube with wall injection. The static pressure at the star recess is found to be more than that at the star point, this feature being in conformity with the analytical result. Flow visualisation by photography of injected smoke seems to show simple diffusion rather than strong vortices in the recess.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arc voltage - current characteristics and threshold current densities occuring during the formation of anode spots in triggered vacuum gaps are reported. Single pulses of 1.65 ms arcing time, which correspond to switching surge currents, are used in the study with copper and aluminum anodes. The threshold values are 1.75 times the values reported earlier using the longer, 8 mis, arcing time. They are found to depend upon the duration of arcing time as well as upon electrode material, surface conditions, electrode size and contact separation. Lateral inhomogenity in the electrode geometry appears to reduce the threshold value by promoting early formation of anode spots.