983 resultados para VISUAL INSPECTION
Resumo:
In this work, a steel heated pultrusion die was designed, developed and manufactured to produce U200 glass fibre reinforced thermosetting matrix (GRP) profiles. The finite element analysis (FEA) was used to predict and optimise the developed die heating by using cylindrical electrical powered cartridges. To assess the new die performance it was mounted in the 120 kN pultrusion line of the Portuguese company Vidropol SA and used to produce continuously U200 profiles able to meet all requirements specified for the E23 grade accordingly to the European Standard EN 13706: 2002. After setting up the type, orientation and sequence of layers in laminate, orthophthalic, isophthalic and bisphenolic unsaturated polyester as well as vinylester resins were used to produce glass fibre reinforced U 200 composite profiles. An appropriated catalyst system was selected and the processing variables optimised for each case, namely, pultrusion pull-speed and die temperature. Finally, the produced U200 profiles were submitted to visual inspection, calcination and mechanical tests, namely, flexural, tensional and interlaminar shear strength (ILSS) tests, to assess their accomplishment with the EN 13706 requirements.
Resumo:
In this work, a new steel heated pultrusion die was designed, developed and manufactured to produce U200 glass fibre reinforced thermosetting matrix (GRP) profiles. The finite element analysis (FEA) was used to predict and optimise the developed die heating by using cylindrical electrical powered cartridges. To assess the new die performance it was mounted in the 120 kN pultrusion line of the Portuguese company Vidropol SA and used to produce continuously U200 profiles able to meet all requirements specified for the E23 grade accordingly to the European Standard EN 13706: 2002. After setting up the type, orientation and sequence of layers in the U 200 laminate, different types of thermosetting resins were used in its production. Orthophthalic, isophthalic and bisphenolic unsaturated polyester as well as vinylester resins were used to produce glass fibre reinforced U 200 composite profiles. All applied resins were submitted to SPI gel tests in order to select the more appropriated catalyst system and optimise the processing variables to be used in each case, namely, pultrusion pull-speed and die temperature. The best pultrusion operational conditions were selected by varying and monitoring the pull-speed and die temperature and, at the same time, measuring the temperature on the manufactured U 200 profile during processing. Finally, the produced U200 profiles were submitted to visual inspection, calcination and mechanical tests, namely, flexural, tensional and interlaminar shear strength (ILSS) tests, to assess their accomplishment with the EN 13706 requirements.
Resumo:
Dissertação de mestrado integrado em Materials Engineering
Resumo:
COST Action TU1406 aims to address the European economic and societal needs by standardizing the condition assessment and maintenance level of roadway bridges. Currently, bridge quality control plans vary from country to country and, in some cases, within the same country. This therefore urges the establishment of a European guideline to surpass the lack of a standard methodology to assess bridge condition and to define quality control plans for roadway bridges. Such a guideline will comprise specific recommendations for assessing performance indicators as well as for the definition of performance goals, bringing together different stakeholders (e.g. universities, institutes, operators, consultants and owners) from various scientific disciplines (e.g. on-site testing, visual inspection, structural engineering, sustainability, etc.) in order to establish a common transnational language. COST Action TU1406 Workshops aim to facilitate the exchange of ideas and experiences between active researchers and practitioners as well as to stimulate discussions on new and emerging issues in line with the conference topics. This first Workshop essentially focuses on WG1 issues, namely, intends to address performance indicators, how these are assessed (e.g. visual inspection, nondestructive tests and monitoring systems), with what frequency and what values are generally obtained. The main outcomes, given in this eBook, were really important, not only for WG1 developments, but also for all the other WGs and for the Action itself.
Resumo:
OBJECTIVE: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. METHODS: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. RESULTS: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. CONCLUSION: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.
Resumo:
Dissertação de mestrado Integrado em Engenharia Civil
Resumo:
La regeneració òssia és un procés estudiat per experts de tot el món. Aquests experts estudien materials capaços d’accelerar el procés de formació de teixit ossi en zones on s’han produït defectes ossis. Després d’un determinat període de temps de l’aplicació dels materials d’estudi en la zona on hi havia una manca de teixit ossi, s’obtenen imatges d’aquesta zona on l’expert mitjançant l’ inspecció visual d’aquestes imatges avalua si l’os s’ha regenerat bé o no. El problema d’aquest mètode d’avaluació es que requereix d’un expert on la valoració d’aquest és subjectiva i difícil de quantificar, el que pot provocar que hi hagi discordança entre experts. Amb la finalitat de aprofitar les imatges en que es basa l’expert per avaluar la capacitat de regeneració òssia dels materials d’estudi es proposa realitzar un anàlisi quantitatiu de la regeneració òssia basat en el processament d’imatge. L’algorisme dissenyat es capaç de classificar imatges de la mandíbula en: imatges de regeneració bona i dolenta mitjançant la parametrització de l’histograma de nivells de grisos de la imatge, solucionant la falta d’objectivitat del mètode d’avaluació de la regeneració òssia i la necessitat d’un expert per realitzar-la.
Resumo:
OBJECTIVE : To determine the prevalence of patient-ventilator asynchrony in patients receiving non-invasive ventilation (NIV) for acute respiratory failure. DESIGN : Prospective multicenter observation study. SETTING : Intensive care units in three university hospitals. METHODS: Patients consecutively admitted to ICU were included. NIV, performed with an ICU ventilator, was set by the clinician. Airway pressure, flow, and surface diaphragmatic electromyography were recorded continuously for 30 min. Asynchrony events and the asynchrony index (AI) were determined from visual inspection of the recordings and clinical observation. RESULTS: A total of 60 patients were included, 55% of whom were hypercapnic. Auto-triggering was present in 8 (13%) patients, double triggering in 9 (15%), ineffective breaths in 8 (13%), premature cycling 7 (12%) and late cycling in 14 (23%). An AI > 10%, indicating severe asynchrony, was present in 26 patients (43%), whose median (25-75 IQR) AI was 26 (15-54%). A significant correlation was found between the magnitude of leaks and the number of ineffective breaths and severity of delayed cycling. Multivariate analysis indicated that the level of pressure support and the magnitude of leaks were weakly, albeit significantly, associated with an AI > 10%. Patient comfort scale was higher in pts with an AI < 10%. CONCLUSION: Patient-ventilator asynchrony is common in patients receiving NIV for acute respiratory failure. Our results suggest that leaks play a major role in generating patient-ventilator asynchrony and discomfort, and point the way to further research to determine if ventilator functions designed to cope with leaks can reduce asynchrony in the clinical setting.
Resumo:
Three hundred and thirteen extracts from 136 Brazilian plant species belonging to 36 families were tested for their suppressive activity on phytohemaglutinin (PHA) stimulated proliferation of human peripheral blood mononuclear cells (PBMC). The proliferation was evaluated by the amount of [³H]-thymidine incorporated by the cells. Twenty extracts inhibited or strongly reduced the proliferation in a dose-dependent manner at doses between 10 and 100 µg/ml. Three of these extracts appeared to be non-toxic to lymphocytes, according to the trypan blue permeability assay and visual inspection using optical microscopy. Bioassay-guided fractionation of Alomia myriadenia extract showed that myriadenolide, a labdane diterpene known to occur in this species, could account for the observed activity of the crude extract. Using a similar protocol, an active fraction of the extract from Gaylussacia brasiliensis was obtained. Analysis of the ¹H and13C NMR spectra of this fraction indicates the presence of an acetylated triterpene whose characterization is underway. The extract of Himatanthus obovatus is currently under investigation.
Resumo:
BACKGROUND: Accurate catalogs of structural variants (SVs) in mammalian genomes are necessary to elucidate the potential mechanisms that drive SV formation and to assess their functional impact. Next generation sequencing methods for SV detection are an advance on array-based methods, but are almost exclusively limited to four basic types: deletions, insertions, inversions and copy number gains. RESULTS: By visual inspection of 100 Mbp of genome to which next generation sequence data from 17 inbred mouse strains had been aligned, we identify and interpret 21 paired-end mapping patterns, which we validate by PCR. These paired-end mapping patterns reveal a greater diversity and complexity in SVs than previously recognized. In addition, Sanger-based sequence analysis of 4,176 breakpoints at 261 SV sites reveal additional complexity at approximately a quarter of structural variants analyzed. We find micro-deletions and micro-insertions at SV breakpoints, ranging from 1 to 107 bp, and SNPs that extend breakpoint micro-homology and may catalyze SV formation. CONCLUSIONS: An integrative approach using experimental analyses to train computational SV calling is essential for the accurate resolution of the architecture of SVs. We find considerable complexity in SV formation; about a quarter of SVs in the mouse are composed of a complex mixture of deletion, insertion, inversion and copy number gain. Computational methods can be adapted to identify most paired-end mapping patterns.
Resumo:
Obtaining automatic 3D profile of objects is one of the most important issues in computer vision. With this information, a large number of applications become feasible: from visual inspection of industrial parts to 3D reconstruction of the environment for mobile robots. In order to achieve 3D data, range finders can be used. Coded structured light approach is one of the most widely used techniques to retrieve 3D information of an unknown surface. An overview of the existing techniques as well as a new classification of patterns for structured light sensors is presented. This kind of systems belong to the group of active triangulation method, which are based on projecting a light pattern and imaging the illuminated scene from one or more points of view. Since the patterns are coded, correspondences between points of the image(s) and points of the projected pattern can be easily found. Once correspondences are found, a classical triangulation strategy between camera(s) and projector device leads to the reconstruction of the surface. Advantages and constraints of the different patterns are discussed
Resumo:
The purpose of this research was to summarize existing nondestructive test methods that have the potential to be used to detect materials-related distress (MRD) in concrete pavements. The various nondestructive test methods were then subjected to selection criteria that helped to reduce the size of the list so that specific techniques could be investigated in more detail. The main test methods that were determined to be applicable to this study included two stress-wave propagation techniques (impact-echo and spectral analysis of surface waves techniques), infrared thermography, ground penetrating radar (GPR), and visual inspection. The GPR technique was selected for a preliminary round of “proof of concept” trials. GPR surveys were carried out over a variety of portland cement concrete pavements for this study using two different systems. One of the systems was a state-of-the-art GPR system that allowed data to be collected at highway speeds. The other system was a less sophisticated system that was commercially available. Surveys conducted with both sets of equipment have produced test results capable of identifying subsurface distress in two of the three sites that exhibited internal cracking due to MRD. Both systems failed to detect distress in a single pavement that exhibited extensive cracking. Both systems correctly indicated that the control pavement exhibited negligible evidence of distress. The initial positive results presented here indicate that a more thorough study (incorporating refinements to the system, data collection, and analysis) is needed. Improvements in the results will be dependent upon defining the optimum number and arrangement of GPR antennas to detect the most common problems in Iowa pavements. In addition, refining highfrequency antenna response characteristics will be a crucial step toward providing an optimum GPR system for detecting materialsrelated distress.
Resumo:
Moisture sensitivity of Hot Mix Asphalt (HMA) mixtures, generally called stripping, is a major form of distress in asphalt concrete pavement. It is characterized by the loss of adhesive bond between the asphalt binder and the aggregate (a failure of the bonding of the binder to the aggregate) or by a softening of the cohesive bonds within the asphalt binder (a failure within the binder itself), both of which are due to the action of loading under traffic in the presence of moisture. The evaluation of HMA moisture sensitivity has been divided into two categories: visual inspection test and mechanical test. However, most of them have been developed in pre-Superpave mix design. This research was undertaken to develop a protocol for evaluating the moisture sensitivity potential of HMA mixtures using the Nottingham Asphalt Tester (NAT). The mechanisms of HMA moisture sensitivity were reviewed and the test protocols using the NAT were developed. Different types of blends as moisture-sensitive groups and non-moisture-sensitive groups were used to evaluate the potential of the proposed test. The test results were analyzed with three parameters based on performance character: the retained flow number depending on critical permanent deformation failure (RFNP), the retained flow number depending on cohesion failure (RFNC), and energy ratio (ER). Analysis based on energy ratio of elastic strain (EREE ) at flow number of cohesion failure (FNC) has higher potential to evaluate the HMA moisture sensitivity than other parameters. If the measurement error in data-acquisition process is removed, analyses based on RFNP and RFNC would also have high potential to evaluate the HMA moisture sensitivity. The vacuum pressure saturation used in AASHTO T 283 and proposed test has a risk to damage specimen before the load applying.
Resumo:
: Objectives Physicochemical incompatibilities between intravenous drugs are a recurrent problem in intensive care units. The present study was aimed at investigating the physical compatibility of remifentanil and sufentanil with other drugs (insulin, midazolam, propofol, potassium chloride, magnesium sulfate, furosemide, heparin, monobasic potassium phosphate) that are frequently administered together intravenously. In addition, the physicochemical compatibility of three common associations of drugs was evaluated in glass tube tests and during dynamic simulated Y site administrations (remifentanil-insulin-midazolam; remifentanil-insulin-propofol; sufentanil-insulin-midazolam). Methods Physical compatibility was verified by visual inspection of the various mixtures (two, three or four drugs) in glass tubes and by pH determination of the mixtures collected during simulated Y site administrations. Solutions were considered as compatible in the absence of any visual change in the solution and of any significant variation in pH value. In addition, chemical stability was checked during in vitro dynamic simulations. The solutions were prepared in 50 ml syringes, placed on syringe pumps and connected to a Swan-Ganz catheter; the liquid collected at the tip was assayed by high performance liquid chromatography. Results In the visual examinations, only the associations of remifentanil and furosemide were incompatible. The three assayed associations were compatible in the tested proportion range over 24 h. Conclusions Remifentanil was physically compatible with the tested drugs, except for furosemide (Lasix; Sanofi-Aventis, 250 mg/25 ml) and physicochemically compatible with insulin and midazolam and insulin and propofol. Sufentanil was physically compatible with all tested drugs and physicochemically compatible with insulin and midazolam
Resumo:
The chemical resistance of ceramic tiles is the subject of the European Standard UNE-EN ISO 10545-13. In order to evaluate the effect of aqueous solutions of several chemicals agents on the aspect of the tile surface, this standard establishes a series of tests at room temperature followed by visual inspection. According to this standard the tiles of this study are classified as being of maximum resistance (UHA). However operating conditions can be more aggressive than those detailed in the standard. So, a systematic study has been undertaken. In the present work, the effect of aqueous solutions of several organic and inorganic acids on the tile surface is evaluated. Samples immersed in different solutions are subjected to the following conditions: T= 60º C; pH=2 and to agitation processes. Visual analysis, as well as optical microscopy and scanning electron microscopy (SEM) were performed in order to determine the possible variation of the superficial aspect of tiles. Moreover, atomic absorption spectrophotometry has been used in order to obtain quantitative information concerning the solubility of system M (III)-L (M= Fe; L= H2O or L= ligand). The results obtained show, in all cases, a progressive dissolution of iron oxide precipitates presents in the ceramic body