977 resultados para VENOUS DOPPLER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. Late portal vein thrombosis (PVT) can be extremely well tolerated, although portal hypertension and other consequences of the long-term deprivation of portal inflow to the graft may be hazardous, especially in young children. Recently, the ""Rex shunt"" has been used successfully to treat these patients. We now report the initial experience with this novel technique. Methods. A 3-year-old girl with PVT at 7 months after whole organ cadaveric liver transplant displayed portal hypertension with an episode of gastrointestinal bleeding, requiring a mesenteric-portal surgical shunt (""Rex shunt"") using a left internal jugular vein autograft. Results. Upon current follow-up of 6 months, postoperative Doppler ultrasound confirmed shunt patency. Endoscopic status was significantly improved after surgery with resolution of portal hypertension. There was no recurrence of bleeding. Conclusions. The mesenteric-portal shunt (""Rex shunt""), using a left internal jugular vein autograft, should be considered for children with late PVT after liver transplantation. Although this is an initial experience, we may conclude that this technique is feasible, with great potential benefits and low risks for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The incidence of venous lesions following transvenous cardiac device implantation is high. Previous implantation of temporary leads ipsilateral to the permanent devices, and a depressed left ventricular ejection fraction have been associated with an increased risk of venous lesions, though the effects of preventive strategies remain controversial. This randomized trial examined the effects of warfarin in the prevention of these complications in high-risk patients. Method: Between February 2004 and September 2007, we studied 101 adults who underwent a first cardiac device implantation, and who had a left ventricular ejection fraction <= 0.40, or a temporary pacing system ipsilateral to the permanent implant, or both. After device implantation, the patients were randomly assigned to warfarin to a target international normalized ratio of 2.0-3.5, or to placebo. Clinical and laboratory evaluations were performed regularly up to 6 months postimplant. Venous lesions were detected at 6 months by digital subtraction venography. Results: Venous obstructions of various degrees were observed in 46 of the 92 patients (50.0%) who underwent venography. The frequency of venous obstructions was 60.4% in the placebo, versus 38.6% in the warfarin group (P = 0.018), corresponding to an absolute risk reduction of 22% (relative risk = 0.63; 95% confidence interval = 0.013-0.42). Conclusions: Warfarin prophylaxis lowered the frequency of venous lesions after transvenous devices implantation in high-risk patients. (PACE 2009; 32:S247-S251)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To examine the effects of betamethasone administration on umbilical artery (UA), middle cerebral artery (MCA) and ductus venosus (DV) Doppler flow. Design. Longitudinal prospective study. Setting: Fetal Surveillance Unit, Department of Obstetrics and Gynecology, University of Sao Paulo, Sao Paulo, Brazil. Population. Thirty-two singleton pregnancies complicated by fetal growth restriction with absent end-diastolic flow in the UA. Methods. Pulsatility index (PI) of the UA, MCA and DV was measured from 26 to 34 weeks prior to and within 24 or 48 hours after starting betamethasone treatment course. Analysis of variance for repeated measures was used to determine the changes in the fetal hemodynamic Doppler flow following maternal corticosteroid administration. Main outcome measures. Improvement of UA-PI within 24 hours and DV-PIV (venous pulsatility) within 48 hours from the first betamethasone dose. Results. Mean gestational age at delivery was 29.3 (1.8) weeks and birthweight was 806.6 (228.2) g. A reduction in the UA-PI was observed in 29 (90.6%) cases, with return of end-diastolic flow in 22 (68.7%). The mean UA-PI were 2.84 (0.52) before corticosteroid administration, 2.07 (0.56) within 24 hours and 2.42 (0.75) after 48 hours, with a significant difference along the evaluations (p0.001). No significant changes in the MCA Doppler were observed. DV-PIV decreased from 1.06 (0.23) prior corticosteroids administration to 0.73 (0.16) within 24 hours and 0.70 (0.19) after 48 hours (p0.001). Conclusions. There was reduction in the umbilical artery and in the DV pulsatility indices within 24 hours from betamethasone administration that was maintained up to 48 hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The ACCM/PALS guidelines address early correction of paediatric septic shock using conventional measures. In the evolution of these recommendations, indirect measures of the balance between systemic oxygen delivery and demands using central venous or superior vena cava oxygen saturation ( ScvO(2) >= 70%) in a goal-directed approach have been added. However, while these additional goal-directed endpoints are based on evidence-based adult studies, the extrapolation to the paediatric patient remains unvalidated. Objective: The purpose of this study was to compare treatment according to ACCM/PALS guidelines, performed with and without ScvO(2) goal-directed therapy, on the morbidity and mortality rate of children with severe sepsis and septic shock. Design, participants and interventions: Children and adolescents with severe sepsis or fluid-refractory septic shock were randomly assigned to ACCM/PALS with or without ScvO(2) goal-directed resuscitation. Measurements: Twenty-eight-day mortality was the primary endpoint. Results: Of the 102 enrolled patients, 51 received ACCM/PALS with ScvO(2) goal-directed therapy and 51 received ACCM/PALS without ScvO(2) goal-directed therapy. ScvO(2) goal-directed therapy resulted in less mortality ( 28-day mortality 11.8% vs. 39.2%, p = 0.002), and fewer new organ dysfunctions ( p = 0.03). ScvO(2) goal-directed therapy resulted in more crystalloid ( 28 ( 20-40) vs. 5 ( 0-20) ml/kg, p < 0.0001), blood transfusion ( 45.1% vs. 15.7%, p = 0.002) and inotropic ( 29.4% vs. 7.8%, p = 0.01) support in the first 6 h. Conclusions: This study supports the current ACCM/PALS guidelines. Goal-directed therapy using the endpoint of a ScvO(2) = 70% has a significant and additive impact on the outcome of children and adolescents with septic shock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose-Plasma glutathione peroxidase (GPx-3) is a major antioxidant enzyme in plasma and the extracellular space that scavenges reactive oxygen species produced during normal metabolism or after oxidative insult. A deficiency of this enzyme increases extracellular oxidant stress, promotes platelet activation, and may promote oxidative posttranslational modification of fibrinogen. We recently identified a haplotype (H-2) in the GPx-3 gene promoter that increases the risk of arterial ischemic stroke among children and young adults. Methods-The aim of this study is to identify possible relationships between promoter haplotypes in the GPx-3 gene and cerebral venous thrombosis (CVT). We studied the GPx-3 gene promoter from 23 patients with CVT and 123 young controls (18 to 45 years) by single-stranded conformational polymorphism and sequencing analysis. Results-Over half of CVT patients (52.1%) were heterozygous (H1H2) or homozygous (H2H2) carriers of the H-2 haplotype compared with 12.2% of controls, yielding a more than 10-fold independent increase in the risk of CVT (OR=10.7; 95% CI, 2.70 to 42.36; P<0.0001). Among women, the interaction of the H2 haplotype with hormonal risk factors increased the OR of CVT to almost 70 (P<0.0001). Conclusions-These findings show that a novel GPx-3 promoter haplotype is a strong, independent risk factor for CVT. As we have previously shown that this haplotype is associated with a reduction in transcriptional activity, which compromises antioxidant activity and antithrombotic benefits of the enzyme, these results suggest that a deficiency of GPx-3 leads to a cerebral venous thrombophilic state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated 16 pregnant women with gestational age between 20 and 32 weeks in acute severe hypertension which were randomly allocated to receive either hydralazine or labetalol. Blood pressure and Doppler ultrasound parameters from maternal uterine and fetal middle cerebral and umbilical arteries were assessed during acute severe hypertension and after treatment. A significant reduction in systolic and diastolic blood pressure was observed in both groups. A significant change in Doppler parameters was observed only in pregnant women who received hydralazine: an increase in uterine arteries resistance index. We concluded that both drugs were highly effective in reducing blood pressure in these women. Despite the observed increase in resistance index of uterine arteries associated with hydralazine, the use of hydralazine and labetalol were not related to any significant changes in fetal Doppler, which is reassuring about the safety of these drugs when treating acute severe hypertension in pregnancy. (E-mail: wpmartins@gmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aims of this study were to assess the feasibility of performing a complete fetal echocardiographic study during the first trimester of pregnancy, to establish the best week to accomplish a complete evaluation, and to find a relationship between the diameters of the cardiac valves and gestational age. Methods: 46 fetuses with normal nuchal translucency and venous duct Doppler velocimetry were submitted to echocardiographic studies by the transvaginal approach between the 11 + 0 and 14 + 6 weeks of gestation. A complete echocardiographic evaluation was defined as an examination in which the three basic planes, four-chamber, longitudinal and short-axis views, were obtained. Results: The rates of complete echocardiography evaluation were 37, 85 and 100% at 11, 12 and 13-14 weeks, respectively. The longitudinal view was the easiest to obtain and the short-axis view was the most difficult one. The diameter of the cardiac valves was compared with the crown-rump length (CRL) and there was no statistically significant difference between either the diameters of the mitral and tricuspid or the aortic and pulmonary valves. A linear growth curve was constructed to demonstrate the diameter correlations. Conclusions: The study demonstrated the feasibility of a complete fetal echocardiographic evaluation by the transvaginal approach during the first trimester of gestation. The rate of a complete evaluation increased along the period and reached 100% when the CRL was 64 mm or 13 weeks of gestational age. There was a linear correlation between the cardiac valve diameters and the CRL revealing a relationship between the cardiac and fetal development. The absence of a statistically significant difference between the left and right valve dimensions possibly means that there is no predominance of right or left chambers during this period of evaluation. Copyright (C) 2007 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a 2-year-old child with extrahepatic portal venous obstruction, hepatoportal sclerosis and pulmonary thromboembolism whose sole hypercoagulability factor was the presence of anti-phospholipid antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. Methods: A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Results: Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). Conclusion: The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although the influence of respiration on ventricular filling, as evaluated by Doppler technique, and the evaluation of diastolic velocities of mitral valve annulus (MVA), as measured by Doppler tissue imaging (DTI), can provide valuable information for the study of left ventricular (LV) diastolic function, the concomitant effects of aging, tidal volume (TV), and respiratory rate (RR) on these velocities have not been quantitatively investigated. Methods: We evaluated 12 normal male volunteers (Group I) aged 20-26 years (mean: 22.8) and 8 normal subjects aged 41 to 54 years old (mean: 45.9) (Group II). Using DTI we measured peak early (E-a) and late (A(a)) velocities of longitudinal axis expansion at lateral and medial MVA. Doppler mitral and tricuspid flow velocities were measured: peak early (E) and late (A) inflow velocity, early (E-i) and late (A(i)) flow integral, and deceleration time of peak early mitral flow velocity (DT). Respiratory cycles were simultaneously recorded at RR of 9, 12, 15, and 18 cycles/min and TV of 600 and 900 mL during respiration (RESP). Results and conclusions: (1) E, A, and A(i) in MV had negligible change during respiration, but E-i was significantly reduced during inspiration; (2) DT reduced slightly with inspiration, but the change was significant only with TV of 900 mL; (3) an important increase of E in right ventricular flow was observed during inspiration; (4) variations of RR and TV did not significantly influence right and left ventricular inflow in normal subjects, in the conditions of this investigation; (5) a significant increase of E-a at medial MVA was documented during inspiration only in young subjects; (6) a significant decrease of A(a) at medial MVA was observed during inspiration in both groups of volunteers; (7) RR and TV did not influence MVA velocities in young and adult subjects; (8) a consistent reduction in E-a and a significant increase in A(a) were observed with increasing age; (9) these changes were more conspicuous and consistent than those documented in ventricular filling when young and middle-age men are compared, suggesting that the DTI is more sensitive to detect changes in diastolic function; and (10) in addition, these data suggest that, for evaluation of diastolic function, in clinical context, it is not necessary to control rigorously RR or TV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the pharmacokinetics of intravenous ciprofloxacin 200 mg every 8 h in critically ill patients on continuous veno-venous haemodiafiltration (CVVHDF), one form of continuous renal replacement therapy (CRRT). Design and setting: Open, prospective clinical study in a multidisciplinary, intensive care unit in a university-affiliated tertiary referral hospital. Patients: Sis critically ill patients with acute renal failure on CVVHDF. Interventions: Timed blood and ultrafiltrate samples were collected to allow pharmacokinetics and clearances to be calculated of initial and subsequent doses of 200 mg intravenous ciprofloxacin. CVVHD was performed with 1 l/h of dialysate and 2 l/h of predilution filtration solution, producing 3 lih of dialysis effluent. The blood was pumped at 200 ml/min using a Gambro BMM-10 blood pump through a Hospal AN69HF haemofilter,. Measurements and results: Ten pharmacokinetic profiles were measured. The CVVHDF displayed a urea clearance of 42 +/- 3 ml/min, and removed ciprofloxacin with a clearance of 37 +/- 7 ml/min. This rate was 2-2.5 greater than previously published for ciprofloxacin in other forms of CRRT. On average the CVVHDF was responsible for clearing a fifth of all ciprofloxacin eliminated (21 +/- 10%). The total body clearance of ciprofloxacin was 12.2 +/- 4.3 l/h. The trough concentration following the initial dose was 0.7 +/- 0.3 mg/l. The area under the plasma concentration time curves over a 24-h period ranged from 21 to 55 mg .h l(-1). Conclusions: Intravenous ciprofloxacin 600 mg/day in critically ill patients using this form of CRRT produced adequate plasma levels for many resistant microbes found in intensive care units.