952 resultados para ULTRASOUND VELOCITY
Resumo:
In high-velocity open channel flows, the measurements of air-water flow properties are complicated by the strong interactions between the flow turbulence and the entrained air. In the present study, an advanced signal processing of traditional single- and dual-tip conductivity probe signals is developed to provide further details on the air-water turbulent level, time and length scales. The technique is applied to turbulent open channel flows on a stepped chute conducted in a large-size facility with flow Reynolds numbers ranging from 3.8 E+5 to 7.1 E+5. The air water flow properties presented some basic characteristics that were qualitatively and quantitatively similar to previous skimming flow studies. Some self-similar relationships were observed systematically at both macroscopic and microscopic levels. These included the distributions of void fraction, bubble count rate, interfacial velocity and turbulence level at a macroscopic scale, and the auto- and cross-correlation functions at the microscopic level. New correlation analyses yielded a characterisation of the large eddies advecting the bubbles. Basic results included the integral turbulent length and time scales. The turbulent length scales characterised some measure of the size of large vortical structures advecting air bubbles in the skimming flows, and the data were closely related to the characteristic air-water depth Y90. In the spray region, present results highlighted the existence of an upper spray region for C > 0.95 to 0.97 in which the distributions of droplet chord sizes and integral advection scales presented some marked differences with the rest of the flow.
Resumo:
In high-velocity free-surface flows, air is continuously being trapped and released through the free-surface. Such high-velocity highly-aerated flows cannot be studied numerically because of the large number of relevant equations and parameters. Herein an advanced signal processing of traditional single- and dual-tip conductivity probes provides some new information on the air-water turbulent time and length scales. The technique is applied to turbulent open channel flows in a large-size facility. The auto- and cross-correlation analyses yield some characterisation of the large eddies advecting the bubbles. The transverse integral turbulent length and time scales are related to the step height: i.e., Lxy/h ~ 0.02 to 0.2, and T.sqrt(g/h) ~ 0.004 to 0.04. The results are irrespective of the Reynolds numbers. The present findings emphasise that turbulent dissipation by large-scale vortices is a significant process in the intermediate zone between the spray and bubbly flow regions (0.3 < C < 0.7). Some self-similar relationships were observed systematically at both macroscopic and microscopic levels. The results are significant because they provide a picture general enough to be used to characterise the air-water flow field in prototype spillways.
Resumo:
In his study of the 'time of arrival' problem in the nonrelativistic quantum mechanics of a single particle, Allcock [1] noted that the direction of the probability flux vector is not necessarily the same as that of the mean momentum of a wave packet, even when the packet is composed entirely of plane waves with a common direction of momentum. Packets can be constructed, for example for a particle moving under a constant force, in which probability flows for a finite time in the opposite direction to the momentum. A similar phenomenon occurs for the Dirac electron. The maximum amount of probabilitiy backflow which can occur over a given time interval can be calculated in each case.
Resumo:
Background. Increased life expectancy in men during the last thirty years is largely due to the decrease in mortality from cardiovascular disease in the age group 29-69 yr. This change has resulted in a change in the disease profile of the population with conditions such as aneurysm of the abdominal aorta (AAA) becoming more prevalent. The advent of endoluminal treatment for AAA has encouraged prophylactic intervention and fuelled the argument to screen for the disease. The feasibility of inserting an endoluminal graft is dependent on the morphology and growth characteristics of the aneurysm. This study used data from a randomized controlled trial of ultrasound screening for AAA in men aged 65-83 yr in Western Australia for the purpose of determining the norms of the living anatomy in the pressurized infrarenal aorta. Aims. To examine (1) the diameters of the infra-renal aorta in aneurysmal and non-aneurysmal cases, (2) the implications for treatment modalities, with particular reference to endoluminal grafting, which is most dependent on normal and aneurysmal morphology, and (3) any evidence to support the notion that northern Europeans are predisposed to aneurysmal disease. Methods. Using ultrasound, a randomized control trial was established in Western Australia to assess the value of a screening program in males aged 65-83 yr, The infra-renal aorta was defined as aneurysmal if the maximum diameter was 30 mm or more. Aortic diameter was modelled both as a continuous tin mm) and as a binary outcome variable, for those men who had an infra-renal diameter of 30 mm or more. ANOVA and linear regression were used for modelling aortic diameter as a continuum, while chi-square analysis and logistic regression were used in comparing men with and without the diagnosis of AAA. Findings. By December 1998, of 19.583 men had been invited to undergo ultrasound screening for AAA, 12.203 accepted the invitation (corrected response fraction 70.8%). The prevalence of AAA increased with age from 4.8% at 65 yr to 10.8% at 80 yr (chi (2) = 77.9, df = 3, P<0.001). The median (IQR) diameter for the non-aneurysmal group was 21.4 mm (3.3 mm) and there was an increase (<chi>(2) = 76.0, df = 1, P<0.001) in the diameter of the infra-renal aorta with age. Since 27 mm is the 95th centile for the non-aneurysmal infra-renal aorta, a diameter of 30 mm or more is justified as defining an aneurysm. The risk of AAA was higher in men of Australian (OR = 1.0) and northern European origin (OR = 1.0, 95%CL: 0.9. 1.2) compared with those of Mediterranean origin (OR = 0.5, 99%CL: 0.4, 0.7). Conclusion. Although screening has not yet been shown to reduce mortality from AAA. these population-based data assist the understanding of aneurysmal disease and the further development and use of endoluminal grafts for this condition. (C) 2001 Published by Elsevier Science Ltd on behalf of The International Society for Cardiovascular Surgery.
Resumo:
A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V-1 Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.
Resumo:
In experiments on isolated animal muscle, the force produced during active lengthening contractions can be up to twice the isometric force, whereas in human experiments lengthening force shows only modest, if any, increase in force. The presence of synergist and antagonist muscle activation associated with human experiments in situ may partly account for the difference between animal and human studies. Therefore, this study aimed to quantify the force-velocity relationship of the human soleus muscle and assess the likelihood that co-activation of antagonist muscles was responsible for the inhibition of torque during submaximal voluntary plantar flexor efforts. Seven subjects performed submaximal voluntary lengthening, shortening(at angular, velocities of +5, -5, +15, -15 and +30, and -30degrees s(-1)) and isometric plantar flexor efforts against an ankle torque motor. Angle-specific (90degrees) measures of plantar flexor torque plus surface and intramuscular electromyography from soleus, medial gastrocnemius and tibialis anterior were made. The level of activation (30% of maximal voluntary isometric effort) was maintained by providing direct visual feedback of the soleus electromyogram to the subject. In an attempt to isolate the contribution of soleus to the resultant plantar flexion torque, activation of the synergist and antagonist muscles were minimised by: (1) flexing the knee of the test limb, thereby minimising the activation of gastrocnemius, and (2) applying an anaesthetic block to the common peroneal nerve to eliminate activation of the primary antagonist muscle, tibialis anterior and the synergist muscles, peroneus longus and peroneus brevis. Plantar flexion torque decreased significantly (P<0.05) after blocking the common peroneal nerve which was likely due to abolishing activation of the peroneal muscles which are synergists for plantar flexion. When normalised to the corresponding isometric value, the force-velocity relationship between pre- and post-block conditions was not different. In both conditions, plantar flexion torques during shortening actions were significantly less than the isometric torque and decreased at faster velocities. During lengthening actions, however, plantar flexion torques were not significantly different from isometric regardless of angular velocity. It was concluded that the apparent inhibition of lengthening torques during voluntary activation is not due to co-activation of antagonist muscles. Results are presented as mean (SEM).
Resumo:
Real-time ultrasound imaging provides an unrivalled opportunity to observe muscle morphology and contraction. This has obvious potential for clinical practice and the tool is beginning to be adopted into physical therapy. The implementation of ultrasound imaging has become particularly widespread for assessment of size and activation of deep trunk muscles, such as the transversus abdominis and lumbar multifidus, and for assessment of the pelvic floor muscles. The obvious benefit for these areas is that ultrasound permits observation of muscles that are difficult to assess through noninvasive means. This realization of the clinical potential of ultrasound imaging has been paralleled by an explosion of clinical and physiological research. However, despite the enthusiasm for utilization of ultrasound imaging, a question that is critical to address is whether ultrasound can actually improve rehabilitation.
Resumo:
The present fundamental knowledge of fluid turbulence has been established primarily from hot- and cold-wire measurements. Unfortunately, however, these measurements necessarily suffer from contamination by noise since no certain method has previously been available to optimally filter noise from the measured signals. This limitation has impeded our progress of understanding turbulence profoundly. We address this limitation by presenting a simple, fast-convergent iterative scheme to digitally filter signals optimally and find Kolmogorov scales definitely. The great efficacy of the scheme is demonstrated by its application to the instantaneous velocity measured in a turbulent jet.
Resumo:
Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
Objectives: The aim of this study was to determine the correlation between ductus venosus (DV) Doppler velocimetry and fetal cardiac troponin T (cTnT). Study design: Between March 2007 and March 2008, 89 high-risk pregnancies were prospectively studied. All patients delivered by cesarean section and the Doppler exams were performed on the same day. Multiple regression included the following variables: maternial age, parity, hypertension, diabetes, gestational age at delivery, umbilical artery (UA) S/D ratio, diagnosis of absent or reversed end-diastolic flow velocity (AREDV) in the UA, middle cerebral artery (MCA) pulsatility index (131), and DV pulsatility index for veins (PIV). Immediately after delivery, UA blood samples were obtained for the measurement of pH and cTnT levels. Statistical analysis included the Kruskal-Wallis test and multiple regressions. Results: The results showed a cTnT concentration at birth >0.05 ng/ml in nine (81.8%) of AREDV cases, a proportion significantly higher than that observed in normal UA S/D ratio and UA S/D ratio >p95 with positive diastolic blood flow (7.7 and 23.1%, respectively, p < 0.001). A positive correlation Was found between abnormal DV-PIV and elevated cTnT levels in the UA. Multiple regression identified DV-PIV and a diagnosis of AREDV as independent factors associated with abnormal fetal cTnT levels (p < 0.0001, F(2.86) = 63.5, R = 0.7722). Conclusion: DV-PIV was significantly correlated with fetal cTnT concentrations at delivery. AREDV and abnormal DV flow represent severe cardiac compromise, with increased systemic venous pressure, and a rise in right ventricular afterload, demonstrated by myocardial damage and elevated fetal cTnT. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
OBJECTIVE To evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO). METHODS We evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW. Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded. After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction. RESULTS The UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g. We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups. CONCLUSION Despite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.