963 resultados para Tricuspid valve
Resumo:
INTRODUCTION: The main clinical manifestations of Whipple's disease are weight loss, arthropathy, diarrhea and abdominal pain. Cardiac involvement is frequently described. However, endocarditis is rare and is not usually the initial presentation of the disease. To the best of our knowledge, this is the first reported case of a patient with Tropheryma whipplei tricuspid endocarditis without any other valve involved and not presenting signs of arthralgia and abdominal involvement. CASE PRESENTATION: We report a case of a 50-year-old Caucasian man with tricuspid endocarditis caused by Tropheryma whipplei, showing signs of severe shock and an absence of other more classic clinical signs of Whipple's disease, such as arthralgia, abdominal pain and diarrhea. Tropheryma whipplei was documented by polymerase chain reaction of the blood and pleural fluid. The infection was treated with a combined treatment of doxycycline, hydroxychloroquine and sulfamethoxazole-trimethoprim for one year. CONCLUSION: Tropheryma whipplei infectious endocarditis should always be considered when facing a blood-culture negative endocarditis particularly in right-sided valves. Although not standardized yet, treatment of Tropheryma whipplei endocarditis should probably include a bactericidal antibiotic (such as doxycycline) and should be given over a prolonged period of time (a minimum of one year).
Resumo:
In a patient with staphylococcus lugdunensis prosthetic aortic valve endocarditis and coronary septic embolism accompanied by antero-lateral myocardial infarction, embolic material was successfully aspirated from the bifurcation of the left anterior descending coronary artery and the first diagonal branch. A good angiographic result was documented six months thereafter when the patient presented with a second complication, pulsatile compression of the left main coronary artery by an abscess cavity originating between the aortic and mitral annulus, leading to congestive heart failure. The patient underwent successful surgical replacement of the aortic valve prosthesis with concomitant patch reconstruction of the annulus as well as tricuspid annuloplasty.
Resumo:
Transcatheter aortic valve replacement (TAVR) has been established as a less invasive alternative to open-heart surgery in inoperable or high-risk patients presenting with symptomatic severe aortic valve stenosis. The feasibility and efficacy of valve-in-valve implantation in degenerated surgical aortic bioprostheses have also been described and can currently be considered a valuable treatment option in patients deemed unsuitable for repeat cardiac surgery. However, the clinical use of TAVR devices is not limited to the treatment of the tricuspid stenotic aortic valve. Several additional indications including treatment of the bicuspid stenotic aortic valve, aortic regurgitation, and valve-in-valve or valve-in-ring implantation in the mitral or tricuspid position as well as treatment of pure mitral, tricuspid, or pulmonary regurgitation have been described. The purpose of the present review is to summarize the available evidence concerning the emerging off-label use of TAVR devices in current clinical practice. Case examples have been selected to highlight the main procedural steps of each particular intervention.
Resumo:
OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).
Resumo:
L’évaluation de la sténose aortique (SA) par échocardiographie Doppler aboutit à une classification discordante de la sévérité chez environ 30 % des patients. La tomodensitométrie qui mesure la calcification valvulaire aortique, un indice de sévérité anatomique, peut alors être utile pour corroborer la sévérité de la SA. De précédentes études ont montré une bonne corrélation entre la sévérité hémodynamique mesurée par échocardiographie Doppler et la sévérité anatomique définie par la calcification valvulaire aortique mesurée par tomodensitométrie. Cependant, l’impact du phénotype de la valve aortique (bicuspide versus tricuspide) et de l’âge sur cette relation entre sévérité hémodynamique et sévérité anatomique reste inconnu. Or, ces deux facteurs sont hautement impliqués dans le développement de la SA. En effet, les patients ayant une valve aortique bicuspide ont une prédisposition à développer une SA, et ce, généralement plus tôt que les patients avec une valve aortique tricuspide. L’hypothèse principale de l’étude est que le phénotype de la valve aortique et l’âge influencent la relation entre la sévérité hémodynamique et la calcification valvulaire aortique de la SA. L’objectif principal de l’étude est d’évaluer l’impact du phénotype de la valve aortique et de l’âge sur la relation entre la sévérité hémodynamique et la calcification valvulaire aortique de la SA.
Resumo:
Le rétrécissement valvulaire aortique (RVA) est causé par une calcification et une fibrose progressive de la valve aortique. Le risque de développer la maladie augmente avec l’âge. À cause de l’augmentation de l’espérance de vie, le RVA est devenu un problème de santé publique. Le RVA est fatal en absence de traitement médical. Actuellement, la chirurgie est le seul traitement pour le stade sévère de la maladie, mais près de 50% des individus avec RVA n’y sont pas éligibles, principalement due à la présence de comorbidités. Plusieurs processus biologiques ont été associés à la maladie, mais les voies moléculaires spécifiques et les gènes impliqués dans le développement et la progression du RVA ne sont pas connus. Il est donc urgent de découvrir les gènes de susceptibilité pour le RVA afin d’identifier les personnes à risque ainsi que les biomarqueurs et les cibles thérapeutiques pouvant mener au développement de médicaments pour inverser ou limiter la progression de la maladie. L’objectif de cette thèse de doctorat était d’identifier la base moléculaire du RVA. Des approches modernes en génomique, incluant l’étude de gènes candidats et le criblage génomique par association (GWAS), ont été réalisées à l’aide de collections d’ADN provenant d’un grand nombre de patients bien caractérisés pour le RVA. Des études complémentaires en transciptomique ont comparé le profil d’expression global des gènes entre des valves calcifiées et non-calcifiées à l’aide de biopuces à ADN et de séquençage de l’ARN. Une première étude a identifié des variations dans le gène NOTCH1 et suggère pour la première fois la présence d’un polymorphisme commun dans ce gène conférant une susceptibilité au RVA. La deuxième étude a combiné par méta-analyse deux GWAS de patients provenant de la ville de Québec et Paris (France) aux données transcriptomiques. Cette étude de génomique intégrative a confirmé le rôle de RUNX2 dans le RVA et a permis l’identification d’un nouveau gène de susceptibilité, CACNA1C. Les troisième et quatrième études sur l’expression des gènes ont permis de mieux comprendre les bases moléculaires de la calcification des valves aortiques bicuspides et ainsi d’identifier de nouvelles cibles thérapeutiques pour le RVA. Les données générées par ce projet sont la base de futures découvertes importantes qui permettront d’améliorer les options de traitement et la qualité de vie des patients atteints du RVA.
Resumo:
Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.
Resumo:
To evaluate the efficacy and safety of intravitreal bevacizumab (IVB) in eyes with neovascular glaucoma (NVG) undergoing Ahmed glaucoma valve (AGV) implantation. This was a multicentre, prospective, randomized clinical trial that enrolled 40 patients with uncontrolled neovascular glaucoma that had undergone panretinal photocoagulation and required glaucoma drainage device implantation. Patients were randomized to receive IVB (1.25 mg) or not during Ahmed valve implant surgery. Injections were administered intra-operatively, and 4 and 8 weeks after surgery. After a mean follow-up of 2.25 ± 0.67 years (range 1.5-3 years), both groups showed a significant decrease in IOP (p < 0.05). There was no difference in IOP between groups except at the 18-month interval, when IOP in IVB group was significantly lower (14.57 ± 1.72 mmHg vs. 18.37 ± 1.06 mmHg - p = 0.0002). There was no difference in survival success rates between groups. At 24 months, there was a trend to patients treated with IVB using less antiglaucoma medications than the control group (p = 0.0648). Complete regression of rubeosis iridis was significantly more frequent in the IVB group (80%) than in the control group (25%) (p = 0.0015). Intravitreal bevacizumab may lead to regression of new vessels both in the iris and in the anterior chamber angle in patients with neovascular glaucoma undergoing Ahmed glaucoma valve implantation. There is a trend to slightly lower IOPs and number of medications with IVB use during AGV implantation for neovascular glaucoma.
Resumo:
Continued assessment of temporal trends in mortality and epidemiology of specific cardiovascular diseases in South America is needed to provide a scientific basis for rational allocation of the limited healthcare resources and introduction of strategies to reduce risk and predict the future burden of cardiovascular disease. The epidemiology of cardiomyopathies, adult valve disease and heart failure (HF) in South America is reviewed here. Diseases of the circulatory system are the main cause of death based on data from about 50% of the South American population. Among the cardiovascular causes of death, cerebrovascular disease is predominant followed by ischaemic heart disease, other heart diseases and hypertensive disease. Of note, cerebrovascular disease is the main cause of death in women, and race also influenced cardiovascular mortality rates. HF is the most important cardiovascular reason for admission to hospital due to cardiovascular disease of ischaemic, idiopathic dilated cardiomyopathic, valvular, hypertensive and chagasic aetiologies. Also, mortality due to HF is high, especially owing to Chagas' disease. HF and aetiologies associated with HF are responsible for 6.3% of deaths. Rheumatic fever is the leading cause of valvular heart disease. The findings have important public health implications because the allocation of healthcare resources, and strategies to reduce the risk of HF should also consider controlling Chagas' disease and rheumatic fever in South American countries.
Resumo:
Among several process variability sources, valve friction and inadequate controller tuning are supposed to be two of the most prevalent. Friction quantification methods can be applied to the development of model-based compensators or to diagnose valves that need repair, whereas accurate process models can be used in controller retuning. This paper extends existing methods that jointly estimate the friction and process parameters, so that a nonlinear structure is adopted to represent the process model. The developed estimation algorithm is tested with three different data sources: a simulated first order plus dead time process, a hybrid setup (composed of a real valve and a simulated pH neutralization process) and from three industrial datasets corresponding to real control loops. The results demonstrate that the friction is accurately quantified, as well as ""good"" process models are estimated in several situations. Furthermore, when a nonlinear process model is considered, the proposed extension presents significant advantages: (i) greater accuracy for friction quantification and (ii) reasonable estimates of the nonlinear steady-state characteristics of the process. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Eight different models to represent the effect of friction in control valves are presented: four models based on physical principles and four empirical ones. The physical models, both static and dynamic, have the same structure. The models are implemented in Simulink/Matlab (R) and compared, using different friction coefficients and input signals. Three of the models were able to reproduce the stick-slip phenomenon and passed all the tests, which were applied following ISA standards. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Freeze-drying of biological tissues allows for dry storage and gamma ray sterilization, which may improve their use as a medical prosthesis. The objective of this study was to evaluate the rehydration characteristics and hydrodynamic performance of prosthetic valves before and after lyophilization. Two size 23 bovine pericardium aortic valve prostheses from different manufacturers were evaluated in a Shelhigh (Union, NJ, USA) pulse duplicator (80 ppm, 5 L/min) before and after lyophilization. Flow and transvalvular pressure gradient were registered in vitro and in vivo, and images of opening and closing of the prosthesis were obtained in the pulse duplicator in a digital camera. Rehydration was evaluated by comparison of dry valve weight with valve weight after 15 min, and 1, 24, 48, and 72 h in saline solution, inside the pulse duplicator. In vivo performance was assessed by surgical implantation in Santa Ines young male sheep in the pulmonary position after 30 min rehydration with 0.9% saline. Transvalvular pressure gradient and flow measurements were obtained immediately after implantation and 3 months after surgery when valves were explanted. Captured images showed a change in the profile opening and closing of valve prosthesis after lyophilization. The gradient measured (in vitro) in two valves was 17.08 +/- 0.57 and 18.76 +/- 0.70 mm Hg before lyophilization, and 34.24 +/- 0.59 and 30.40 +/- 0.97 mm Hg after lyophilization. Rehydration of both lyophilized valves was approximately 82%. Drying changed the profile of the opening and closing of valve prostheses, and increased on average by 83% the gradient in vitro tests. The result of the in vivo tests suggests maintaining pressure levels of the animal with the lyophilized prostheses within acceptable levels.
Resumo:
The `biomimetic` approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD`s inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber, variable throttle and reservoir, connected by silicone tubings. The reservoir sat on an elevated platform, allowing adjustment of ventricular preload between 0 and 11 mmHg. To allow for sterile gaseous exchange between the circuit interior and exterior, a 0.2 mu m filter was placed at the reservoir. Pressure and flow were registered downstream of the TE valve. The circuit was filled with culture medium and fitted in a standard 5% CO(2) incubator set at 37 degrees C. Pressure and flow waveforms were similar to those obtained under physiological conditions for the pulmonary circulation. The `cardiomimetic` approach presented here represents a new perspective to conventional biomimetic approaches in TE, with potential advantages. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
Background. Human aortic valve allografts elicit a cellular and humoral immune response. It is not clear whether this is important in promoting valve damage. We investigated the changes in morphology, cell populations, and major histocompatibility complex antigen distribution in the rat aortic valve allograft. Methods. Fresh heart valves from Lewis rats were transplanted into the abdominal aorta of DA rats. Valves from allografted, isografted, and presensitized recipient rats were examined serially with standard morphologic and immunohistochemical techniques. Results. In comparison with isografts, the allografts were infiltrated and thickened by increased numbers of CD4(+) and CD8(+) lymphocytes, macrophages, and fibroblasts. Thickening of the valve wall and leaflet and the density of the cellular infiltrate was particularly evident after presensitization. Endothelial cells were frequently absent in presensitized allografts whereas isografts had intact endothelium. Cellular major histocompatibility complex class I and II antigens in the allograft were substantially increased. A long-term allograft showed dense fibrosis and disruption of the media with scattered persisting donor cells. Conclusions. The changes in these aortic valve allograft experiments are consistent with an allograft immune response and confirm that the response can damage aortic valve allograft tissue. (C) 1998 by The Society of Thoracic Surgeons.