975 resultados para Treatment planning
Resumo:
PURPOSE Hodgkin lymphoma (HL) is a highly curable disease. Reducing late complications and second malignancies has become increasingly important. Radiotherapy target paradigms are currently changing and radiotherapy techniques are evolving rapidly. DESIGN This overview reports to what extent target volume reduction in involved-node (IN) and advanced radiotherapy techniques, such as intensity-modulated radiotherapy (IMRT) and proton therapy-compared with involved-field (IF) and 3D radiotherapy (3D-RT)- can reduce high doses to organs at risk (OAR) and examines the issues that still remain open. RESULTS Although no comparison of all available techniques on identical patient datasets exists, clear patterns emerge. Advanced dose-calculation algorithms (e.g., convolution-superposition/Monte Carlo) should be used in mediastinal HL. INRT consistently reduces treated volumes when compared with IFRT with the exact amount depending on the INRT definition. The number of patients that might significantly benefit from highly conformal techniques such as IMRT over 3D-RT regarding high-dose exposure to organs at risk (OAR) is smaller with INRT. The impact of larger volumes treated with low doses in advanced techniques is unclear. The type of IMRT used (static/rotational) is of minor importance. All advanced photon techniques result in similar potential benefits and disadvantages, therefore only the degree-of-modulation should be chosen based on individual treatment goals. Treatment in deep inspiration breath hold is being evaluated. Protons theoretically provide both excellent high-dose conformality and reduced integral dose. CONCLUSION Further reduction of treated volumes most effectively reduces OAR dose, most likely without disadvantages if the excellent control rates achieved currently are maintained. For both IFRT and INRT, the benefits of advanced radiotherapy techniques depend on the individual patient/target geometry. Their use should therefore be decided case by case with comparative treatment planning.
Resumo:
Little data concerning the perceived success of implant therapy in comparison with endodontic treatment exists. While the criteria used to measure the outcome of each modality are not the same, it is not clear if this is appreciated by practicing dentists. The purpose of the study was to evaluate the perceived outcome of implant therapy in comparison to endodontic treatment. A 23 question Web-based survey was distributed to 648 dentists who matriculated from the University of Connecticut School Of Dental Medicine over the past 30 years. The response rate was 47%. Sixty-seven percent of respondents were general dentists. Forty-nine percent of respondents did not know different criteria exist in the literature and are used to evaluate implant and root canal treatment. Fifty-four percent of dentists felt the prognosis of implant therapy was the same as or better than endodontic treatment of teeth with vital pulps. Thirty percent of responders thought root canal treatment of teeth with necrotic pulp was superior to implants and only 16% thought retreatment was preferable. Treatment planning for implant placement vs. retreatment of a restorable tooth was 46% and 32%, respectively. A third of the respondents felt that the role of endodontics will decline in the future. Dentists’ primary source of information regarding implant therapy was continuing education; however, their primary source of information regarding endodontic treatment was their dental program. Dentists felt the prognosis of implant therapy was as good or superior to endodontic treatment of teeth with vital, necrotic or previously treated pulps.
Resumo:
The purpose of this study, based on secondary data from attendees at a substance abuse clinic for the Kickapoo Healing Grounds in Eagle Pass, Texas, is two fold: (1) to elucidate neuro-behavioral performance of volatile substance abusers in the Kickapoo tribe and (2) to determine factors associated with their treatment completion and rehabilitation as measured by their employment at follow-up. Volatile substance abuse (VSA) is associated with a host of neurological manifestations, and secondary prevention or clinical treatment and rehabilitation remains the mainstay of control efforts. Very little is known about VSA in general, and especially among Native American populations. It is anticipated that the results will help determine and assist other tribes and non-tribal substance abuse centers with treatment planning for volatile substance abusers among Native American populations. ^
Resumo:
External beam radiation therapy is used to treat nearly half of the more than 200,000 new cases of prostate cancer diagnosed in the United States each year. During a radiation therapy treatment, healthy tissues in the path of the therapeutic beam are exposed to high doses. In addition, the whole body is exposed to a low-dose bath of unwanted scatter radiation from the pelvis and leakage radiation from the treatment unit. As a result, survivors of radiation therapy for prostate cancer face an elevated risk of developing a radiogenic second cancer. Recently, proton therapy has been shown to reduce the dose delivered by the therapeutic beam to normal tissues during treatment compared to intensity modulated x-ray therapy (IMXT, the current standard of care). However, the magnitude of stray radiation doses from proton therapy, and their impact on this incidence of radiogenic second cancers, was not known. ^ The risk of a radiogenic second cancer following proton therapy for prostate cancer relative to IMXT was determined for 3 patients of large, median, and small anatomical stature. Doses delivered to healthy tissues from the therapeutic beam were obtained from treatment planning system calculations. Stray doses from IMXT were taken from the literature, while stray doses from proton therapy were simulated using a Monte Carlo model of a passive scattering treatment unit and an anthropomorphic phantom. Baseline risk models were taken from the Biological Effects of Ionizing Radiation VII report. A sensitivity analysis was conducted to characterize the uncertainty of risk calculations to uncertainties in the risk model, the relative biological effectiveness (RBE) of neutrons for carcinogenesis, and inter-patient anatomical variations. ^ The risk projections revealed that proton therapy carries a lower risk for radiogenic second cancer incidence following prostate irradiation compared to IMXT. The sensitivity analysis revealed that the results of the risk analysis depended only weakly on uncertainties in the risk model and inter-patient variations. Second cancer risks were sensitive to changes in the RBE of neutrons. However, the findings of the study were qualitatively consistent for all patient sizes and risk models considered, and for all neutron RBE values less than 100. ^
Resumo:
Proton therapy is growing increasingly popular due to its superior dose characteristics compared to conventional photon therapy. Protons travel a finite range in the patient body and stop, thereby delivering no dose beyond their range. However, because the range of a proton beam is heavily dependent on the tissue density along its beam path, uncertainties in patient setup position and inherent range calculation can degrade thedose distribution significantly. Despite these challenges that are unique to proton therapy, current management of the uncertainties during treatment planning of proton therapy has been similar to that of conventional photon therapy. The goal of this dissertation research was to develop a treatment planning method and a planevaluation method that address proton-specific issues regarding setup and range uncertainties. Treatment plan designing method adapted to proton therapy: Currently, for proton therapy using a scanning beam delivery system, setup uncertainties are largely accounted for by geometrically expanding a clinical target volume (CTV) to a planning target volume (PTV). However, a PTV alone cannot adequately account for range uncertainties coupled to misaligned patient anatomy in the beam path since it does not account for the change in tissue density. In order to remedy this problem, we proposed a beam-specific PTV (bsPTV) that accounts for the change in tissue density along the beam path due to the uncertainties. Our proposed method was successfully implemented, and its superiority over the conventional PTV was shown through a controlled experiment.. Furthermore, we have shown that the bsPTV concept can be incorporated into beam angle optimization for better target coverage and normal tissue sparing for a selected lung cancer patient. Treatment plan evaluation method adapted to proton therapy: The dose-volume histogram of the clinical target volume (CTV) or any other volumes of interest at the time of planning does not represent the most probable dosimetric outcome of a given plan as it does not include the uncertainties mentioned earlier. Currently, the PTV is used as a surrogate of the CTV’s worst case scenario for target dose estimation. However, because proton dose distributions are subject to change under these uncertainties, the validity of the PTV analysis method is questionable. In order to remedy this problem, we proposed the use of statistical parameters to quantify uncertainties on both the dose-volume histogram and dose distribution directly. The robust plan analysis tool was successfully implemented to compute both the expectation value and its standard deviation of dosimetric parameters of a treatment plan under the uncertainties. For 15 lung cancer patients, the proposed method was used to quantify the dosimetric difference between the nominal situation and its expected value under the uncertainties.
Resumo:
This qualitative investigation primarily employing a phenomenological perspective and psychoanalytic interview approach intends to provide contextual understanding of group dynamics in sex offender treatment involving individuals with strong features of personality disorders or Axis II psychopathology according to the Diagnostic and Statistical Manual of Mental Disorder (4 ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000). Of note, this study particularly focuses on the cluster B type (Narcissistic, Borderline, Histrionic, and Antisocial Personality Disorders), based on the assumption that this type is more interpersonally operational in its nature. The present study is based on semi-structured interviews of three clinicians who arecurrently providing group treatment for sex offenders. The interview was designed to elicit the participants' clinical observations of group dynamics involving group members with features of the Axis II, Cluster B type. In this study, 11 therapeutic factors postulated by Yalom (2005) were utilized to qualitatively investigate group dynamics. Analyses of qualitative data highlighted how group members with features of the Axis II, Cluster B type may distinctively affect group dynamics. Based on the results, group members with Axis II diagnoses, as reported bythe therapists who responded to this study, were observed to present with altruistic behaviors in group. In addition, motivation appeared to be one of the most influential factors in promoting and maintaining therapeutic group behaviors. Group members with antisocial features appeared to present with low motivation for treatment, and individualswith a pervasive history of criminal institutionalization seemed more prone to disengagement in group. Individuals with borderline and histrionic traits seemed to be interpersonally oriented and affectively engaged in group process. Persons with a narcissistic tendency also appeared to be interpersonally invested and showed altruistic behaviors, yet the importance of confirming their superiority seemed to outweigh the need for acceptance or approval from other group members. As briefly discussed above, the qualitative analyses of the current data showed that individuals with Axis II disorders, Cluster B type uniquely affect group dynamics, which suggest clinical considerations foreffective treatment planning, maintenance, and outcomes.
Resumo:
Liver cancer accounts for nearly 10% of all cancers in the US. Intrahepatic Arterial Radiomicrosphere Therapy (RMT), also known as Selective Internal Radiation Treatment (SIRT), is one of the evolving treatment modalities. Successful patient clinical outcomes require suitable treatment planning followed by delivery of the microspheres for therapy. The production and in vitro evaluation of various polymers (PGCD, CHS and CHSg) microspheres for a RMT and RMT planning are described. Microparticles with a 30±10 µm size distribution were prepared by emulsion method. The in vitro half-life of the particles was determined in PBS buffer and porcine plasma and their potential application (treatment or treatment planning) established. Further, the fast degrading microspheres (≤ 48 hours in vitro half-life) were labeled with 68Ga and/or 99mTc as they are suitable for the imaging component of treatment planning, which is the primary emphasis of this dissertation. Labeling kinetics demonstrated that 68Ga-PGCD, 68Ga-CHSg and 68Ga-NOTA-CHSg can be labeled with more than 95% yield in 15 minutes; 99mTc-PGCD and 99mTc-CHSg can also be labeled with high yield within 15-30 minutes. In vitro stability after four hours was more than 90% in saline and PBS buffer for all of them. Experiments in reconstituted hemoglobin lysate were also performed. Two successful imaging (RMT planning) agents were found: 99mTc-CHSg and 68Ga-NOTA-CHSg. For the 99mTc-PGCD a successful perfusion image was obtained after 10 minutes, however the in vivo degradation was very fast (half-life), releasing the 99mTc from the lungs. Slow degrading CHS microparticles (> 21 days half-life) were modified with p-SCN-b-DOTA and labeled with 90 Y for production of 90Y-DOTA-CHS. Radiochemical purity was evaluated in vitro and in vivo showing more than 90% stability after 72 and 24 hours respectively. All agents were compared to their respective gold standards (99mTc-MAA for 68Ga-NOTA-CHSg and 99m Tc-CHSg; 90Y-SirTEX for 90Y-DOTA-CHS) showing superior in vivo stability. RMT and RMT planning agents (Therapy, PET and SPECT imaging) were designed and successfully evaluated in vitro and in vivo.
Resumo:
Knowledge-based radiation treatment is an emerging concept in radiotherapy. It
mainly refers to the technique that can guide or automate treatment planning in
clinic by learning from prior knowledge. Dierent models are developed to realize
it, one of which is proposed by Yuan et al. at Duke for lung IMRT planning. This
model can automatically determine both beam conguration and optimization ob-
jectives with non-coplanar beams based on patient-specic anatomical information.
Although plans automatically generated by this model demonstrate equivalent or
better dosimetric quality compared to clinical approved plans, its validity and gener-
ality are limited due to the empirical assignment to a coecient called angle spread
constraint dened in the beam eciency index used for beam ranking. To eliminate
these limitations, a systematic study on this coecient is needed to acquire evidences
for its optimal value.
To achieve this purpose, eleven lung cancer patients with complex tumor shape
with non-coplanar beams adopted in clinical approved plans were retrospectively
studied in the frame of the automatic lung IMRT treatment algorithm. The primary
and boost plans used in three patients were treated as dierent cases due to the
dierent target size and shape. A total of 14 lung cases, thus, were re-planned using
the knowledge-based automatic lung IMRT planning algorithm by varying angle
spread constraint from 0 to 1 with increment of 0.2. A modied beam angle eciency
index used for navigate the beam selection was adopted. Great eorts were made to assure the quality of plans associated to every angle spread constraint as good
as possible. Important dosimetric parameters for PTV and OARs, quantitatively
re
ecting the plan quality, were extracted from the DVHs and analyzed as a function
of angle spread constraint for each case. Comparisons of these parameters between
clinical plans and model-based plans were evaluated by two-sampled Students t-tests,
and regression analysis on a composite index built on the percentage errors between
dosimetric parameters in the model-based plans and those in the clinical plans as a
function of angle spread constraint was performed.
Results show that model-based plans generally have equivalent or better quality
than clinical approved plans, qualitatively and quantitatively. All dosimetric param-
eters except those for lungs in the automatically generated plans are statistically
better or comparable to those in the clinical plans. On average, more than 15% re-
duction on conformity index and homogeneity index for PTV and V40, V60 for heart
while an 8% and 3% increase on V5, V20 for lungs, respectively, are observed. The
intra-plan comparison among model-based plans demonstrates that plan quality does
not change much with angle spread constraint larger than 0.4. Further examination
on the variation curve of the composite index as a function of angle spread constraint
shows that 0.6 is the optimal value that can result in statistically the best achievable
plans.
Resumo:
PURPOSE: Radiation therapy is used to treat cancer using carefully designed plans that maximize the radiation dose delivered to the target and minimize damage to healthy tissue, with the dose administered over multiple occasions. Creating treatment plans is a laborious process and presents an obstacle to more frequent replanning, which remains an unsolved problem. However, in between new plans being created, the patient's anatomy can change due to multiple factors including reduction in tumor size and loss of weight, which results in poorer patient outcomes. Cloud computing is a newer technology that is slowly being used for medical applications with promising results. The objective of this work was to design and build a system that could analyze a database of previously created treatment plans, which are stored with their associated anatomical information in studies, to find the one with the most similar anatomy to a new patient. The analyses would be performed in parallel on the cloud to decrease the computation time of finding this plan. METHODS: The system used SlicerRT, a radiation therapy toolkit for the open-source platform 3D Slicer, for its tools to perform the similarity analysis algorithm. Amazon Web Services was used for the cloud instances on which the analyses were performed, as well as for storage of the radiation therapy studies and messaging between the instances and a master local computer. A module was built in SlicerRT to provide the user with an interface to direct the system on the cloud, as well as to perform other related tasks. RESULTS: The cloud-based system out-performed previous methods of conducting the similarity analyses in terms of time, as it analyzed 100 studies in approximately 13 minutes, and produced the same similarity values as those methods. It also scaled up to larger numbers of studies to analyze in the database with a small increase in computation time of just over 2 minutes. CONCLUSION: This system successfully analyzes a large database of radiation therapy studies and finds the one that is most similar to a new patient, which represents a potential step forward in achieving feasible adaptive radiation therapy replanning.
Resumo:
Background: Benefits of mobile phone deployment for children <5 in low-resource settings remain unproven. The target population of the current demonstration study in Bushenyi District, Uganda, presented with acute fever, pneumonia, or diarrhoea and were treated by community health workers (CHWs) providing integrated community case management (iCCM). Methods: An observational study was conducted in five parishes (47 villages) served by CHWs well versed in iCCM with supplemental training in mobile phone use. Impact was assessed by quantitative measures and qualitative evaluation through household surveys, focus group discussions, and key informant interviews. Results: CHWs in targeted sites improved child healthcare through mobile phone use coupled with iCCM. Of acutely ill children, 92.6% were correctly managed. Significant improvements in clinical outcomes compared to those obtained by CHWs with enhanced iCCM training alone were unproven in this limited demonstration. Nonetheless, qualitative evaluation showed gains in treatment planning, supply management, and logistical efficiency. Provider confidence and communications were enhanced as was ease and accuracy of record keeping. Conclusion: Mobile phones appear synergistic with iCCM to bolster basic supportive care for acutely ill children provided by CHWs. The full impact of expanded mobile phone deployment warrants further evaluation prior to scaling up in low-resource settings.
Resumo:
Liver cancer accounts for nearly 10% of all cancers in the US. Intrahepatic Arterial Radiomicrosphere Therapy (RMT), also known as Selective Internal Radiation Treatment (SIRT), is one of the evolving treatment modalities. Successful patient clinical outcomes require suitable treatment planning followed by delivery of the microspheres for therapy. The production and in vitro evaluation of various polymers (PGCD, CHS and CHSg) microspheres for a RMT and RMT planning are described. Microparticles with a 30±10 µm size distribution were prepared by emulsion method. The in vitro half-life of the particles was determined in PBS buffer and porcine plasma and their potential application (treatment or treatment planning) established. Further, the fast degrading microspheres (≤ 48 hours in vitro half-life) were labeled with 68Ga and/or 99mTc as they are suitable for the imaging component of treatment planning, which is the primary emphasis of this dissertation. Labeling kinetics demonstrated that 68Ga-PGCD, 68Ga-CHSg and 68Ga-NOTA-CHSg can be labeled with more than 95% yield in 15 minutes; 99mTc-PGCD and 99mTc-CHSg can also be labeled with high yield within 15-30 minutes. In vitro stability after four hours was more than 90% in saline and PBS buffer for all of them. Experiments in reconstituted hemoglobin lysate were also performed. Two successful imaging (RMT planning) agents were found: 99mTc-CHSg and 68Ga-NOTA-CHSg. For the 99mTc-PGCD a successful perfusion image was obtained after 10 minutes, however the in vivo degradation was very fast (half-life), releasing the 99mTc from the lungs. Slow degrading CHS microparticles (> 21 days half-life) were modified with p-SCN-b-DOTA and labeled with 90Y for production of 90Y-DOTA-CHS. Radiochemical purity was evaluated in vitro and in vivo showing more than 90% stability after 72 and 24 hours respectively. All agents were compared to their respective gold standards (99mTc-MAA for 68Ga-NOTA-CHSg and 99mTc-CHSg; 90Y-SirTEX for 90Y-DOTA-CHS) showing superior in vivo stability. RMT and RMT planning agents (Therapy, PET and SPECT imaging) were designed and successfully evaluated in vitro and in vivo.
Resumo:
Alpha-particle emitters, notably used in 224Ra-DaRT, have emerged as effective in overcoming radiation resistance and providing targeted cancer therapy. These emitters cause DNA double-strand breaks, visualizable in human lymphocytes. The 224Ra DaRT technique, using a decay chain from seeds, extends alpha particle range, achieving complete tumor destruction while sparing healthy tissue. This thesis examines a biokinetic model, validated with patient data, and a feasibility study on skin squamous cell carcinomas are discussed. The study reports 75% tumor complete response rate and 48% patients experiencing acute grade 2 toxicity, resolving within a month. An observed abscopal effect (AE), where tumor regression occurs at non-irradiated sites, is examined, highlighting DaRT's potential in triggering anti-tumor immune responses. This effect, coupled with DaRT's high-linear energy transfer (LET), suggests its superiority over low-LET radiation in certain clinical scenarios. Improvements to DaRT, including the use of an external radio-opaque template for treatment planning, are explored. This advancement aids in determining source numbers for optimal tumor coverage, enhancing DaRT’s safety. The thesis outlines a typical DaRT procedure, from tumor measurements to source assessment and administration, emphasizing the importance of precise seed positioning. Furthermore, the thesis discusses DaRT's potential in treating prostate cancer, a prevalent global health issue, by offering an alternative to traditional salvage therapies. DaRT seeds, delivering alpha particle-based interstitial radiation, require precision in seed insertion due to their limited tissue range. In conclusion, the thesis advocates for DaRT's role in treating solid tumors, emphasizing its improved radiobiological potency and potential benefits over beta and gamma source-based therapies. Ongoing studies are assessing DaRT's feasibility in treating various solid tumors, including pancreatic, breast, prostate, and vulvar malignancies, suggesting a promising future in cancer treatment.
Resumo:
INTRODUÇÃO: a tomografia computadorizada (TC) permite a visualização do osso alveolar que recobre os dentes por vestibular e lingual. OBJETIVO: o propósito deste estudo foi expor e discutir as implicações da morfologia do osso alveolar, visualizado por meio da TC, sobre o diagnóstico e plano de tratamento ortodôntico. MÉTODOS: foram descritas as evidências sobre a inter-relação entre características dentofaciais e a morfologia das tábuas ósseas vestibular e lingual, assim como evidências sobre a repercussão da movimentação ortodôntica sobre o nível e espessura dessas estruturas periodontais. RESULTADOS: pacientes adultos podem apresentar deiscências ósseas previamente ao tratamento ortodôntico, principalmente na região dos incisivos inferiores. Os pacientes com padrão de crescimento vertical parecem apresentar menor espessura das tábuas ósseas vestibular e lingual no nível do ápice dos dentes permanentes, comparados a pacientes com padrão de crescimento horizontal. O movimento dentário vestibulolingual descentraliza os dentes do rebordo alveolar e ocasiona deiscências ósseas. CONCLUSÃO: a morfologia do rebordo alveolar constitui um fator limitante para a movimentação dentária e deve ser considerada, de forma individual, na realização do plano de tratamento ortodôntico.
Resumo:
OBJETIVO: esta revisão de literatura visa avaliar, através de literatura específica, a sensibilidade e especificidade do exame de ressonância magnética (RM) para o diagnóstico dos desarranjos internos da articulação temporomandibular (ATM). METODOLOGIA: tanto artigos que utilizaram ATM de cadáveres para comparar achados anatômicos aos achados de ressonância magnética (RM), como artigos que compararam achados clínicos com achados de RM foram utilizados. Através dos achados desses artigos, as propriedades de sensibilidade e especificidade da RM para o diagnóstico de desarranjos internos da ATM foram calculadas. Com isso, a confiabilidade e a aplicabilidade do exame de RM no diagnóstico dos desarranjos internos da ATM foram discutidas. RESULTADOS: encontrou-se sensibilidade de 90% e especificidade de 88% da RM para desarranjos internos da ATM. CONCLUSÃO: o exame de RM de ATM possui ótima sensibilidade e especificidade para o diagnóstico dos desarranjos internos da ATM. Porém, tal exame deve ser solicitado com cautela, apenas nos casos onde a imagem seja indispensável para o plano de tratamento.
Resumo:
The strategy used to treat HCV infection depends on the genotype involved. An accurate and reliable genotyping method is therefore of paramount importance. We describe here, for the first time, the use of a liquid microarray for HCV genotyping. This liquid microarray is based on the 5'UTR - the most highly conserved region of HCV - and the variable region NS5B sequence. The simultaneous genotyping of two regions can be used to confirm findings and should detect inter-genotypic recombination. Plasma samples from 78 patients infected with viruses with genotypes and subtypes determined in the Versant (TM) HCV Genotype Assay LiPA (version I; Siemens Medical Solutions, Diagnostics Division, Fernwald, Germany) were tested with our new liquid microarray method. This method successfully determined the genotypes of 74 of the 78 samples previously genotyped in the Versant (TM) HCV Genotype Assay LiPA (74/78, 95%). The concordance between the two methods was 100% for genotype determination (74/74). At the subtype level, all 3a and 2b samples gave identical results with both methods (17/17 and 7/7, respectively). Two 2c samples were correctly identified by microarray, but could only be determined to the genotype level with the Versant (TM) HCV assay. Genotype ""1'' subtypes (1a and 1b) were correctly identified by the Versant (TM) HCV assay and the microarray in 68% and 40% of cases, respectively. No genotype discordance was found for any sample. HCV was successfully genotyped with both methods, and this is of prime importance for treatment planning. Liquid microarray assays may therefore be added to the list of methods suitable for HCV genotyping. It provides comparable results and may readily be adapted for the detection of other viruses frequently co-infecting HCV patients. Liquid array technology is thus a reliable and promising platform for HCV genotyping.