915 resultados para Total hip arthroplasty revision surgery · tabular reconstruction · Bone loss · Ceramics
Resumo:
The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.
Resumo:
BACKGROUND: Recent studies have suggested that tenotomy and repair of the subscapularis tendon carried out for anterior approaches to the shoulder can be followed by failure of the tendon repair and by changes resulting in permanent loss of subscapularis function. We hypothesized that release of the subscapularis with use of a superficial osteotomy of the lesser tuberosity followed by repair of the two opposing bone surfaces would lead to consistent bone-to-bone healing, which would be possible to monitor radiographically, and would lead to satisfactory clinical and structural outcomes. METHODS: Thirty-nine shoulders in thirty-six consecutive patients who, at an average age of fifty-seven years, had undergone total shoulder replacement through an anterior approach involving an osteotomy of the lesser tuberosity were evaluated at an average of thirty-nine months. Assessment included a standardized interview and physical examination, scoring according to the system described by Constant and Murley, and imaging with conventional radiography and computed tomography to assess healing of the osteotomy site and changes in the subscapularis. RESULTS: The osteotomized tuberosity fragment healed in an anatomical position in all shoulders, and no cuff tendon ruptures were observed. At the time of follow-up, thirty-three (89%) of thirty-seven shoulders evaluated with a belly-press test had a negative result and twenty-seven (75%) of thirty-six shoulders evaluated with a lift-off test had an unequivocally normal result. Fatty infiltration of the subscapularis muscle increased after the operation (p < 0.0001) and was at least stage two in eleven (32%) of thirty-four shoulders. The fatty infiltration had progressed by one stage in eight (24%) of the thirty-four shoulders, by two stages in five shoulders (15%), and by three stages in two shoulders (6%). CONCLUSIONS: Osteotomy of the lesser tuberosity provides an easy anterior approach for total shoulder replacement and is followed by consistent bone-to-bone healing, which can be monitored, and good subscapularis function. In the presence of documented anatomical healing of the osteotomy site, postoperative fatty infiltration of the subscapularis muscle remains unexplained and needs to be investigated further as it is associated with a poorer clinical outcome.
Resumo:
Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measuring leg length. Guided by the navigation system, cups were placed in 40.8 degrees +/- 2 degrees of operative abduction (range, 35 degrees -50 degrees) and 30.8 degrees +/- 3.2 degrees (range, 19 degrees -43 degrees) of operative anteversion. We subsequently measured radiographic abduction on plain anteroposterior pelvic radiographs and calculated abduction and anteversion. Radiographically, 97.1 % of the cups were in the safe zone for abduction and 92.4% for anteversion. The mean incision length was less than 8 cm for 327 of the 344 hips. Leg length change measured intraoperatively was 6.6 +/- 4.1 mm (range, -2-22), similar to measurements from the pre- and postoperative magnification-corrected radiographs. Computer assistance during THA increased the consistency of component positioning and allowed reliable measurement of leg length change during surgery.
Resumo:
The occurrence of audible squeaking in some patients with ceramic-on-ceramic (CoC) hip prostheses is a cause for concern. Considering multifactor contributing to this phenomenon, many studies have been conducted over the last decade. Great efforts have been put on understanding the mechanics of the hip squeaking to gain a deep insight into factors resulting in sound emission from hip articulation. Disruption of fluid-film lubrication and friction were reported as main potential causes of hip squeaking, while patient and surgical factors as well as design and material of hip implants were identified as affecting factors. This review article therefore summarised the recent available literature on this subject to provide a platform for future developments. Moreover, high wear rates and ceramic liner fracture as viable consequences of hip squeaking were discussed.
Resumo:
We evaluated midterm patient-reported outcomes and satisfaction with total hip arthroplasty in patients who had severe juvenile idiopathic arthritis. Thirty-one patients (49 hips), with a mean age of 29 years (range, 16-43 years), reported low hip pain and stiffness at follow-up (mean, 7 years; range, 3-17 years). Up to 92% were satisfied with their ability to perform various activities; 96% were satisfied with pain relief. A mean postoperative flexion arc of 96° was observed. Final 36-Item Short Form Health Survey, EuroQol in 5 dimensions, Western Ontario and McMaster Universities Arthritis Index, and Harris Hip scores were lower than reference populations, particularly for mobility, physical functioning, and social functioning subscores. Young adults with end-stage hip involvement and severe longstanding juvenile idiopathic arthritis expressed high satisfaction with total hip arthroplasty, which improved range of motion, pain, and stiffness, despite poor performance on widely used outcome measures.
Resumo:
Introducción. Las imágenes obtenidas mediante rayos X, determinan una conducta clínica en ortopedia y son analizadas por parte del cirujano en el momento previo a realizar un acto quirúrgico. El planeamiento pre quirúrgico basado en radiografías de cadera, permite predecir el tamaño de los componentes protésicos a utilizar en un reemplazo de cadera. Con el advenimiento de las radiografías digitales, existe la falsa percepción de que estas tienen corregido el factor de magnificación. La corrección de dicho factor requiere un protocolo de calibración de imágenes, aún no implementado en la Fundación Santa Fe de Bogotá (FSFB). Como consecuencia, las radiografías de cadera actualmente resultan magnificadas. Materiales y métodos. Fueron seleccionados 73 pacientes con reemplazo articular total de la cadera intervenidos en la FSFB. Para cada paciente, se estableció la dimensión de la cabeza protésica en la radiografía de cadera obtenida mediante el sistema de radiología digital (PACS-IMPAX) y su tamaño fue comparado con el de la cabeza femoral implantada. Resultados. La concordancia entre los dos observadores al medir la dimensión radiológica de los componentes protésicos fue excelente y el coeficiente de magnificación promedio de 1.2 (20%). Este será introducido al PACS-IMPAX para ajustar el tamaño definitivo de la radiografía. Conclusión. El ajuste del PACS-IMPAX permite obtener radiografías en las cuales se refleja con mayor precisión el tamaño de los segmentos anatómicos y de los componentes protésicos.
Resumo:
OBJECTIVES The aim of the present longitudinal study was to investigate bacterial colonization of the internal implant cavity and to evaluate a possible association with peri-implant bone loss. METHODS A total of 264 paper point samples were harvested from the intra-implant cavity of 66 implants in 26 patients immediately following implant insertion and after 3, 4, and 12 months. Samples were evaluated for Aggregatibacter actinomycetemcomitans, Fusobacterium nucleatum, Porphyromonas gingivalis, Prevotella intermedia, Treponema denticola, and Tannerella forsythia as well as total bacterial counts by real-time PCR. Bone loss was evaluated on standardized radiographs up to 25 months after implant insertion. For the statistical analysis of the data, mixed effects models were fitted. RESULTS There was an increase in the frequency of detection as well as in the mean counts of the selected bacteria over time. The evaluation of the target bacteria revealed a significant association of Pr. intermedia at 4 and 12 months with peri-implant bone loss at 25 months (4 months: P = 0.009; 12 months: P = 0.021). CONCLUSIONS The present study could demonstrate a progressive colonization by periodontopathogenic bacteria in the internal cavities of two-piece implants. The results suggest that internal colonization with Pr. intermedia was associated with peri-implant bone loss.
Resumo:
We compared revision and mortality rates of 4668 patients undergoing primary total hip and knee replacement between 1989 and 2007 at a University Hospital in New Zealand. The mean age at the time of surgery was 69 years (16 to 100). A total of 1175 patients (25%) had died at follow-up at a mean of ten years post-operatively. The mean age of those who died within ten years of surgery was 74.4 years (29 to 97) at time of surgery. No change in comorbidity score or age of the patients receiving joint replacement was noted during the study period. No association of revision or death could be proven with higher comorbidity scoring, grade of surgeon, or patient gender. We found that patients younger than 50 years at the time of surgery have a greater chance of requiring a revision than of dying, those around 58 years of age have a 50:50 chance of needing a revision, and in those older than 62 years the prosthesis will normally outlast the patient. Patients over 77 years old have a greater than 90% chance of dying than requiring a revision whereas those around 47 years are on average twice as likely to require a revision than die. This information can be used to rationalise the need for long-term surveillance and during the informed consent process.
Resumo:
INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.
Resumo:
Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.
Resumo:
Large-headed total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) with metal-on-metal (MoM) bearings became popular during the last decade. Recently, it has become evident that the large-head MoM hip implants are associated with increased revision rates despite their theoretical advantages. The purpose of this study was to evaluate the early results of primary MoM hip replacements and of acetabular revisions. I analyzed retrospectively the results of four MoM implant designs and the survival rate of acetabular revisions with impaction bone grafting, as documented in the Turku University Hospital database. Further, I evaluated the correlation between femoral head size and dislocation rate, and used the Finnish Arthroplasty Register data to compare the survival of three large-head MoM THAs to analogous HRAs. The early results for the Magnum M2A–ReCap THA were good. A larger head size decreased the risk of dislocation. Articular surface replacement (ASR) THA yielded inferior results compared to analogous HRA. For two other designs the results were similar. The R3–Synergy THA yielded inferior results compared to the reference implants. The survival of acetabular reconstructions with impaction bone grafting was inferior compared to previous reports. In conclusion, the early results of the Biomet ReCap–Magnum design were promising, and large head sizes decreased the dislocation rate. The survival of different MoM hip implant designs varied. The survival of new designs and techniques may be inferior to those reported by the clinics where implants are developed. An important caveat is that early promising results of new devices may rapidly worsen. New implants need to be introduced in a controlled fashion to the market; here, arthroplasty registers are a valuable tool that needs to be used.
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
Increased risk of bleeding after major orthopedic surgery (MOS) has been widely documented in general population. However, this complication has not been studied in elderly patients. The purpose of this study is to determine whether the risk of major bleeding after MOS is higher in elderly patients, compared with those operated at a younger age. Methods: This retrospective cohort study included total hip and total knee arthroplasty patients operated during 5 consecutive years. The main outcome was the occurrence of major bleeding. Patients with other causes of bleeding were excluded. Relative risks (RRs) and confidence intervals (CIs) were calculated, anda multivariate analysis was performed. Results: A total of 1048 patients were included, 56% of patients were hip arthroplasties. At the time of surgery, 553 (53%) patients were older than 70 years. Patients aged >70 years showed an increased risk of major bleeding (RR: 2.42 [95% CI: 1.54-3.81]). For hip arthroplasty, the RR of bleeding was 2.61 (95%CI: 1.50-4.53) and 2.25 (95% CI: 1.03-4.94) for knee arthroplasty. After multivariate analysis, age was found to be independently associated with higher risk of major bleeding. Conclusion: According to European Medicines Agency criteria, patients aged 70 years are at a higher risk of major bleeding after MOS, result of a higher frequency of blood transfusions in this group of patients. Standardized protocols for blood transfusion in these patients are still required.
Resumo:
The aim of this study was to estimate the additional cost of treatment of a group of nosocomial infections in a tertiary public hospital. A retrospective observational cohort study was conducted by means of analyzing the medical records of 34 patients with infection after total knee arthroplasty, diagnosed in 2006 and 2007, who met the criteria for nosocomial infection according to the Centers for Disease Control and Prevention. To estimate the direct costs of treatment for these patients, the following data were gathered: length of hospital stay, laboratory tests, imaging examinations, and surgical procedures performed. Their costs were estimated from the minimum values according to the Brazilian Medical Association. The estimated cost of the antibiotics used was also obtained. The total length of stay in the ward was 976 days, at a cost of US$ 18,994.63, and, in the intensive care unit, it was 34 days at a cost of US$ 5,031.37. Forty-two debridement procedures were performed, at a cost of US$ 5,798.06, and 1965 tests (laboratory and imaging) were also performed, at a cost of US$ 15,359.25. US$ 20,845.01 was spent on antibiotics and US$ 1,735.16 on vacuum assisted closure therapy, microsurgical flaps, implant removal, spacer use, and surgical revision. The total additional cost of these cases of hospital infection in 2006 and 2007 was of US$ 91,843.75. Based on that, we demonstrate that the high cost of treatment for hospital infections emphasizes the importance of taking measures to prevent and control hospital infection.