973 resultados para Thickness swelling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the association between retinal nerve fibre layer (RNFL) thickness and diabetic peripheral neuropathy in people with type 2 diabetes, and specifically those at higher risk of foot ulceration. Methods RNFL thicknesses was measured globally and in four quadrants (temporal, superior, nasal and inferior) at 3.45 mm diameter around the optic nerve head using optical coherence tomography (OCT). Severity of neuropathy was assessed using the Neuropathy Disability Score (NDS). Eighty-two participants with type 2 diabetes were stratified according to NDS scores (0-10) as: none, mild, moderate, and severe neuropathy. A control group was additionally included (n=17). Individuals with NDS≥ 6 (moderate and severe neuropathy) have been shown to be at higher risk of foot ulceration. A linear regression model was used to determine the association between RNFL and severity of neuropathy. Age, disease duration and diabetic retinopathy levels were fitted in the models. Independent t-test was employed for comparison between controls and the group without neuropathy, as well as for comparison between groups with higher and lower risk of foot ulceration. Analysis of variance was used to compare across all NDS groups. Results RNFL thickness was significantly associated with NDS in the inferior quadrant (b= -1.46, p=0.03). RNFL thicknesses globally and in superior, temporal and nasal quadrants did not show significant associations with NDS (all p>0.51). These findings were independent of the effect of age, disease duration and retinopathy. RNFL was thinner for the group with NDS ≥ 6 in all quadrants but was significant only inferiorly (p<0.005). RNFL for control participants was not significantly different from the group with diabetes and no neuropathy (superior p=0.07, global and all other quadrants: p>0.23). Mean RNFL thickness was not significantly different between the four NDS groups globally and in all quadrants (p=0.08 for inferior, P>0.14 for all other comparisons). Conclusions Retinal nerve fibre layer thinning is associated with neuropathy in people with type 2 diabetes. This relationship is strongest in the inferior retina and in individuals at higher risk of foot ulceration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To quantitatively assess and compare the quality of life (QoL) of women with a self-reported diagnosis of lower limb lymphedema (LLL), to women with lower limb swelling (LLS), and to women without LLL or LLS following treatment for endometrial cancer. Methods 1399 participants in the Australian National Endometrial Cancer Study were sent a follow-up questionnaire 3–5 years after diagnosis. Women were asked if they had experienced swelling in the lower limbs and, if so, whether they had received a diagnosis of lymphedema by a health professional. The 639 women who responded were categorised as: Women with LLL (n = 68), women with LLS (n = 177) and women without LLL or LLS (n = 394). Multivariable-adjusted generalized linear models were used to compare women’s physical and mental QoL by LLL status. Results On average, women were 65 years of age and 4 years after diagnosis. Women with LLL had clinically lower physical QoL (M= 41.8, SE= 1.4) than women without LLL or LLS (M= 45.1, SE= 0.8, p = .07), however, their mental QoL was within the normative range (M= 49.6; SE= 1.1 p = 1.0). Women with LLS had significantly lower physical (M= 41.0, SE= 1.0, p = .003) and mental QoL (M= 46.8; SE= 0.8, p < .0001) than women without LLL or LLS (Mental QoL: M= 50.6, SE= 0.8). Conclusion Although LLL was associated with reductions in physical QoL, LLS was related to reductions in both physical and mental QoL 3-5 years after cancer treatment. Early referral to evidence-based lymphedema programs may prevent long-term impairments to women’s QoL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Australian masonry standard allows either prism tests or correction factors based on the block height and mortar thickness to evaluate masonry compressive strength. The correction factor helps the taller units with conventional 10 mm mortar being not disadvantaged due to size effect. In recent times, 2-4 mm thick, high-adhesive mortars and H blocks with only the mid-web shell are used in masonry construction. H blocks and thinner and higher adhesive mortars have renewed interest of the compression behaviour of hollow concrete masonry and hence is revisited in this paper. This paper presents an experimental study carried out to examine the effects of the thickness of mortar joints, the type of mortar adhesives and the presence of web shells in the hollow concrete masonry prisms under axial compression. A non-contact digital image correlation technique was used to measure the deformation of the prisms and was found adequate for the determination of strain fi eld of the loaded face shells subjected to axial compression. It is found that the absence of end web shells lowers the compressive strength and stiffness of the prisms and the thinner and higher adhesive mortars increase the compressive strength and stiffness, while lowering the Poisson's ratio. © Institution of Engineers Australia, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamic light scattering (DLS) has become a primary nanoparticle characterization technique with applications from materials characterization to biological and environmental detection. With the expansion in DLS use from homogeneous spheres to more complicated nanostructures, comes a decrease in accuracy. Much research has been performed to develop different diffusion models that account for the vastly different structures but little attention has been given to the effect on the light scattering properties in relation to DLS. In this work, small (core size < 5 nm) core-shell nanoparticles were used as a case study to measure the capping thickness of a layer of dodecanethiol (DDT) on Au and ZnO nanoparticles by DLS. We find that the DDT shell has very little effect on the scattering properties of the inorganic core and hence can be ignored to a first approximation. However, this results in conventional DLS analysis overestimating the hydrodynamic size in the volume and number weighted distributions. By introducing a simple correction formula that more accurately yields hydrodynamic size distributions a more precise determination of the molecular shell thickness is obtained. With this correction, the measured thickness of the DDT shell was found to be 7.3 ± 0.3 Å, much less than the extended chain length of 16 Å. This organic layer thickness suggests that on small nanoparticles, the DDT monolayer adopts a compact disordered structure rather than an open ordered structure on both ZnO and Au nanoparticle surfaces. These observations are in agreement with published molecular dynamics results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deformation of a rectangular block into an annular wedge is studied with respect to the state of swelling interior to the block. Nonuniform swelling fields are shown to generate these flexure deformations in the absence of resultant forces and bending moments. Analytical expressions for the deformation fields demonstrate these effects for both incompressible and compressible generalizations of conventional hyperelastic materials. Existing results in the absence of a swelling agent are recovered as special cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using retinal imaging, the nature and extent of compromise of retinal structural integrity has been characterized in individuals suffering from diabetic peripheral neuropathy. These findings extend our understanding of the pathological processes involved in diabetic neuropathy and offer novel ophthalmic approaches to the diagnosis and monitoring of this debilitating condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the film thickness and postannealing temperature on visible photoluminescence (PL) from Si Nx films synthesized by plasma-assisted radio frequency magnetron sputtering on Si O2 buffer layers is investigated. It is shown that strong visible PL is achieved at annealing temperatures above 650 °C. The optimum annealing temperature for the maximum PL yield strongly depends on the film thickness and varies from 800 to 1200°C. A comparative composition-structure-property analysis reveals that the PL intensity is directly related to the content of the Si-O and Si-N bonds in the Si Nx films. Therefore, sufficient oxidation and moderate nitridation of Si Nx Si O2 films during the plasma-based growth process are crucial for a strong PL yield. Excessively high annealing temperatures lead to weakened Si-N bonds in thinner Si Nx films, which eventually results in a lower PL intensity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations. Methods Scheimpflug imaging was captured before, immediately following and 3 hours after a short period (3 hours) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear. Results Small but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels three hours after lens removal. During the three hour recovery period significant corneal thinning (-13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = -0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean -0.144 ± 0.075 μm, p = 0.02). Conclusions Flattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human choroid is capable of rapidly changing its thickness in response to a variety of stimuli. However little is known about the role of the autonomic nervous system in the regulation of the thickness of the choroid. Therefore, we investigated the effect of topical parasympatholytic and sympathomimetic agents upon the choroidal thickness and ocular biometrics of young healthy adult subjects. Fourteen subjects (mean age 27.9 ± 4 years) participated in this randomized, single-masked, placebo-controlled study. Each subject had measurements of choroidal thickness (ChT) and ocular biometrics of their right eye taken before, and then 30 and 60 min following the administration of topical pharmacological agents. Three different drugs: 2% homatropine hydrobromide, 2.5% phenylephrine hydrochloride and a placebo (0.3% hydroxypropyl methylcellulose) were tested in all subjects; each on different days (at the same time of the day) in randomized order. Participants were masked to the pharmacological agent being used at each testing session. The instillation of 2% homatropine resulted in a small but significant increase in subfoveal ChT at 30 and 60 min after drug instillation (mean change 7 ± 3 μm and 14 ± 2 μm respectively; both p < 0.0001). The parafoveal choroid also exhibited a similar magnitude, significant increase in thickness with time after 2% homatropine (p < 0.001), with a mean change of 7 ± 0.3 μm and 13 ± 1 μm (in the region located 0.5 mm from the fovea center), 6 ± 1 μm and 12.5 ± 1 μm (1 mm from the fovea center) and 6 ± 2 μm and 12 ± 2 μm (1.5 mm from the fovea center) after 30 and 60 min respectively. Axial length decreased significantly 60 min after homatropine (p < 0.01). There were also significant changes in lens thickness (LT) and anterior chamber depth (ACD) (p < 0.05) associated with homatropine instillation. No significant changes in choroidal thickness, or ocular biometrics were found after 2.5% phenylephrine or placebo at any examination points (p > 0.05). In human subjects, significant increases in subfoveal and parafoveal choroidal thickness occurred after administration of 2% homatropine and this implies an involvement of the parasympathetic system in the control of choroidal thickness in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To examine macular retinal thickness and retinal layer thickness with spectral domain optical coherence tomography (OCT) in a population of children with normal ocular health and minimal refractive errors. Methods High resolution macular OCT scans from 196 children aged from 4 to 12 years (mean age 8 ± 2 years) were analysed to determine total retinal thickness and the thickness of 6 different retinal layers across the central 5 mm of the posterior pole. Automated segmentation with manual correction was used to derive retinal thickness values. Results The mean total retinal thickness in the central 1 mm foveal zone was 255 ± 16 μm, and this increased significantly with age (mean increase of 1.8 microns per year) in childhood (p<0.001). Age-related increases in thickness of some retinal layers were also observed, with changes of highest statistical significance found in the outer retinal layers in the central foveal region (p<0.01). Significant topographical variations in thickness of each of the retinal layers were also observed (p<0.001). Conclusions Small magnitude, statistically significant increases in total retinal thickness and retinal layer thickness occur from early childhood to adolescence. The most prominent changes appear to occur in the outer retinal layers of the central fovea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim Retinal tissue integrity in relation to diabetic neuropathy is not known. The aim of this study was to investigate retinal tissue thickness in relation to diabetic peripheral neuropathy (DPN) with and without diabetic retinopathy (DR). Methods Full retinal thickness at the parafoveal and perifoveal macula and neuro-retinal thickness around the optic nerve head (ONH) and at the macula was examined using spectral domain optical coherence tomography. The eye on the hand-dominant side of 85 individuals with type 1 diabetes and 66 individuals with type 2 diabetes, with or without DR and DPN, were compared to the eyes (n=45) of age-matched non-diabetic controls. Diabetic neuropathy was defined as Neuropathy Disability Score (NDS) ≥3 on a scale of 0-10. A general linear model was used to examine the relationship between diabetic neuropathy and foveal, parafoveal and perifoveal retinal thickness and neuro-retinal thickness, in relation to DR status, age, gender, HbA1c levels and duration of diabetes. A p-value of <0.05 was considered statistically significant. Results Perifoveal retinal thickness is reduced with increasing severity of neuropathy, especially in the inferior hemisphere (p=0.004); this effect was not related to age (p=0.088). For every unit increase in NDS score, the inferior perifoveal retinal thickness reduced by 1.64 μm. Neuro-retinal thickness around the ONH decreased with increasing severity of neuropathy (p<0.014 for average and hemisphere thicknesses); for every unit increase in NDS, neuro-retinal thickness around the ONH reduced by 1.23 μm. Retinal thickness in the parafovea was increased in the absence of DR (p<0.017 for average and hemisphere thicknesses). Neuro-retinal thickness at the macula was inversely related to age alone (p<0.001). All retinal parameters, except the inferior perifovea, reduced with advancing age (p<0.007 for all). Conclusions Diabetic neuropathy is associated with changes in full retinal thickness and neuro-retinal layers. This may represent a second threat to vision integrity, in addition to the better-characterised retinopathy. This study provides new knowledge about the anatomical aspects of the retinal tissue in relation to neuropathy and retinopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To assess the effects of eye rubbing on corneal thickness (CT) and intraocular pressure (IOP) measurements obtained 0-30min after habitual eye rubbing in symptomatic patients. METHODS Measurements of IOP and CT were obtained at five locations (central, temporal, superior, nasal and inferior) before, and every 5min for 30min interval after 30s of eye rubbing, for 25 randomly selected eyes of 14 subjects with ocular allergy and 11 age-matched normals. Differences in measurements were calculated in each group [Baseline measurements minus measurements recorded at each time interval after eye rubbing (for IOP), and for each corneal location (for CT)] and comparison were then made between groups (allergic versus control) for differences in any observed effects. RESULTS Within groups, baseline mean IOPs in the allergic patient-group (14.2±3.0 mm Hg) and in the control group (13.1±1.9 mm Hg) were similar at all times, after eye rubbing (P >0.05, for all). The maximum reduction in IOP was 0.8 mm Hg in the control subjects and the maximum increase was also 0.8 mm Hg in the allergic subjects. Between groups (allergic versus control), the changes in IOP remained under 1 mm Hg at all times (P=0.2) after 30min of eye rubbing. Between 0 and 30min of CT measurements after eye rubbing, the mean central CT (CCT), inferior CT (ICT), superior CT (SCT), temporal CT (TCT) and nasal CT (NCT) did not vary significantly from baseline values in the control and allergic-subject groups (P>0.05, for both). Between both groups, changes in CT were similar at all locations (P>0.05) except for the TC which was minimally thinner by about 4.4 µm (P=0.001) in the allergic subjects than in the control subjects, 30min following 30s of eye rubbing. CONCLUSION IOP measured in allergic subjects after 30s of habitual eye rubbing was comparable with that obtained in normal subjects at all times between 0 and 30min. Although, CT in the allergic subjects were similar to those of the control subjects at all times, it varied between +10 and -7.5 µm following eye rubbing, with the temporal cornea showing consistent reductions in thickness in the subjects with allergy. However, this reduction was minimal and was considered to not be clinically relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rheological property of F-actin cytoskeleton is significant to the restructuring of cytoskeleton under a variety of cell activities. This study numerically validates the rheological property of F-actin cytoskeleton is not only a result of kinetic energy dissipation of F-actin, but also greatly depends on the configuration remodeling of networks structure. Both filament geometry and crosslinker properties can affect the remodeling of F-actin cytoskeleton. The crosslinker unbinding is found to dissipate energy and induce prominent stress relaxation in the F-actin adjacent to cross-linkages. Coupled with F-actin elasticity, the energy dissipation and stress relaxation are more significant in bundled F-actin networks than in single F-actin networks.