954 resultados para Test reliability


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: The aim of this study was to test the reliability and construct validity of a reactive agility test (RAT), designed for Australian Football (AF).

Methods: Study I tested the reliability of the RAT, with 20 elite junior AF players (17.44 ± 0.55 y) completing the test on two occasions separated by 1 wk. Study II tested its construct validity by comparing the performance of 60 participants (16.60 ± 0.50 y) spread over three aged-matched population groups: 20 athletes participating in a State Under-18 AF league who had represented their state at national competitions (elite), 20 athletes participating in the same league who had not represented their state (subelite), and 20 healthy males who did not play AF (controls).

Results:
Test-retest reliability reported a strong correlation (0.91), with no significant difference (P = .22) between the mean results (1.74 ± 0.07 s and 1.76 ± 0.07 s) obtained (split 2+3). Nonparametric tests (Kruskal-Wallis and Mann-Whitney) revealed both AF groups performed significantly faster on all measures than the control group (ranging from P = .001 to .005), with significant differences also reported between the two AF groups (ranging from P = .001 to .046). Stepwise discriminant analyses found total time discriminated between the groups, correctly classifying 75% of the participants.

Conclusions:
The RAT used within this study demonstrates evidence of reliability and construct validity. It further suggests the ability of a reactive component within agility test designs to discriminate among athletes of different competition levels, highlighting its importance within training activities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose. The purposes of the study were to investigate the test-retest reliability and the validity of new versions of the Melbourne Edge Test (MET) and the High/Low Contrast Visual Acuity (H/LCVA) chart and to investigate the agreement between the original and new versions.

Methods. The MET original photographic version, MET new light box version, H/LCVA Chart original photographic version, H/LCVA Chart new printed version, and the Pelli-Robson chart were administered twice to one eye of 22 subjects with low vision and 20 soft contact lenses wearers.

Results. For the low vision group, the test-retest 95% limits of agreement were ±5.2 dB for the MET new light box version and ±0.39 logarithm of the minimum angle of resolution (logMAR) for the LCVA component of the H/LCVA new printed version. For the soft contact lens group, the test-retest 95% limits of agreement were ±2.1 dB for the MET new light box version and ± 0.26 logMAR for the LCVA component of the H/LCVA new printed version. Moderate to high correlations were obtained between contrast sensitivity tests, thus providing evidence of validity. Scores obtained for the new test versions were significantly higher than the original versions (p < 0.01).

Conclusions. Of all the tests administered, the MET original photographic version and the Pelli-Robson Chart had the highest test-retest reliability for the low vision group. For the soft contact lens group, the H/LCVA original version (low contrast letters, 18% Weber) and the Pelli-Robson Chart had the highest reliability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Design:: Reliability Study - cross sectional. Methods: Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. Results: A total of 37 children (65% girls) aged 4-8 years (M= 6.2, SD=0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC= 0.93), and for individual skills, highest for the dribble (ICC= 0.94) followed by strike (ICC= 0.85), overhand throw (ICC= 0.84), underhand roll (ICC= 0.82), kick (ICC= 0.80) and the catch (ICC= 0.71). The strike and the throw had more components with less agreement. Conclusions: Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Breaks in prolonged sitting may have beneficial cardiometabolic and musculoskeletal health outcomes. Desk-based work settings are an important environment to promote and support breaks in sitting time. However, few studies have reported the psychometric properties of self-report measures to assess the frequency and duration of breaks from sitting. This study examined the concurrent validity and test-retest reliability of the Workplace Sitting Breaks Questionnaire (SITBRQ) designed to assess frequency and duration of breaks in sitting within desk-based work settings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.

Relevância:

40.00% 40.00%

Publicador: