974 resultados para Tear film stability
Resumo:
The aim of this study was to describe long-term follow-up and difference in immune reactions in the tear film following penetrating keratoplasty (PK) in horses when differently preserved corneas were utilised. This report describes for the first time the use of corneal grafts preserved in tissue culture media in equine PK. Eight experimental horses with normal eyes were included and freshly harvested, frozen or preserved corneal grafts were used for the PK. The graft-taking technique and storage, PK surgery, postoperative treatments and complications are described. The mean postoperative follow-up time was 286 days. Tear film samples taken before and periodically after surgery were measured for IgM, IgG and IgA contents by direct ELISA. All grafts were incorporated into the donor horse but were rejected to some degree. The differently harvested corneal grafts healed in the same manner and looked similar. Preoperatively, the clear corneas meant low risk for graft failure, and the fresh or stored tissues provided intact endothelium, although there were no clear graft sites postoperatively. The presence of IgA, IgG and IgM was demonstrated in the tear film from the early postoperative period. IgG levels were lower than IgA or IgM and had a constant baseline in every case, as IgA and IgM had great variability with time and an individual pattern in each eye.
Resumo:
A Ceratoconjuntivite Seca (KCS Keratoconjunctivitis Sicca) é uma desordem imunomediada e resulta de alterações do componente aquoso do filme lacrimal e da deficiência dos componentes lipídicos e mucoso.Seu diagnóstico é baseado no Teste Lacrimal de Schirmer (TLS) e no Teste de Ruptura do Filme Lacrimal (TRFL) e tem como sinais clínicos: secreção mucopurulenta, hiperemia conjuntival, blefaroespasmos, fotofobia, incômodo, dor, vascularização, opacidade corneana e pigmentação, além de cegueira em casos avançados. O tratamento convencional consiste em aplicações diárias de Ciclosporina 0,2% ou Tacrolimus 0,03% (pomada ou colírio oftálmicos), que apesar de controlar a doença, são custosos, não curativos e exigem alto comprometimento da interação paciente-proprietário. A terapia celular usando células-tronco (CT) traz uma nova esperança para doenças sem tratamento efetivo. Neste trabalho utilizamos CT mesenquimais (CTM) obtidas a partir de membrana amniótica (CTMA) de cães obtidas a partir do descarte destes tecidos em campanhas de castrações em diferentes tempos gestacionais, sem formação tumoral quando submetidas ao teste tumorigênico durante 60 dias. Dois animais com KCS crônica foram tratados com duas injeções de CTMA com intervalo de 30 dias, sendo a primeira de 0,5x106 células e a segunda de 1x106 células em cada glândula. Na segunda semana após a terapia foi observado aumento da TLS sugerindo um benéficio da terapia que foi diminuindo com o passar das semanas. O TRFL oscilou durante os testes e não apresentou diferenças significativas. A terapia celular utilizando CTMA de cães melhorou a condição ocular nos dois casos em momentos e parâmetros variados, com repercussão na melhoria da superfície, mas não houve regressão do quadro clínico. Investigações futuras em estágios menos avançados da doença podem ajudar a elucidar os mecanismos pelos quais esse efeito foi obtido
Resumo:
Purpose: To evaluate and characterize the clinical profile of young asymptomatic or minimally symptomatic patients without diagnosis of dry eye but showing signs compatible with dry eye syndrome (DES). Methods: Prospective study including a total of 50 consecutive subjects with ages ranging from 18 to 40 years that were identified as asymptomatic or minimally symptomatic by means of the Ocular Surface Disease Index (OSDI) (score of <22). In all patients, a complete battery of tests for the diagnosis of DES was performed including the evaluation of the tear film break-up time (TFBUT), the level of corneal and conjunctival staining, and the eyelid and Meibomian morphology. Results: The OSDI score was significantly higher in women than in men (median: 12.5 vs. 5.3, P=0.01). Low grades of ocular surface staining, dysfunction of Meibomian gland expression, and alteration of quality of Meibomian secretions were observed in 56%, 58%, and 84% of eyes, respectively. More eyes with some dysfunction of Meibomian gland expressibility had a TFBUT less than 5 sec (P=0.033). A statistically significant difference in the OSDI score was found between patients with and without systemic allergies (P=0.036) and between male and female (P=0.01). Likewise, the OSDI score was significantly higher in those women wearing contact lenses compared with those not wearing them (P=0.012). Conclusions: Asymptomatic or minimally symptomatic young subjects may present low grades of clinical signs compatible with DES, with a trend to more symptomatology in women and allergic patients. These outcomes should be confirmed in future studies with larger samples.
Resumo:
PURPOSE: To perform advanced analysis of the corneal deformation response to air pressure in keratoconics compared with age- and sex-matched controls. METHODS: The ocular response analyzer was used to measure the air pressure-corneal deformation relationship of 37 patients with keratoconus and 37 age (mean 36 ± 10 years)- and sex-matched controls with healthy corneas. Four repeat air pressure-corneal deformation profiles were averaged, and 42 separate parameters relating to each element of the profiles were extracted. Corneal topography and pachymetry were performed with the Orbscan II. The severity of the keratoconus was graded based on a single metric derived from anterior corneal curvatures, difference in astigmatism in each meridian, anterior best-fit sphere, and posterior best-fit sphere. RESULTS: Most of the biomechanical characteristics of keratoconic eyes were significantly different from normal eyes (P <0.001), especially during the initial corneal applanation. With increasing keratoconus severity, the cornea was thinner (r = -0.407, P <0.001), the speed of corneal concave deformation past applanation was quicker (dive; r = -0.314, P = 0.01), and the tear film index was lower (r = -0.319, P = 0.01). The variance in keratoconus severity could be accounted for by the corneal curvature and central corneal thickness (r = 0.80) with biomechanical characteristics contributing an additional 4% (total r = 0.84). The area under the receiver operating characteristic curve was 0.919 ± 0.025 for keratometry alone, 0.965 ± 0.014 with the addition of pachymetry, and 0.972 ± 0.012 combined with ocular response analyzer biomechanical parameters. CONCLUSIONS: Characteristics of the air pressure-corneal deformation profile are more affected by keratoconus than the traditionally extracted corneal hysteresis and corneal resistance factors. These biomechanical metrics slightly improved the detection and severity prediction of keratoconus above traditional keratometric and pachymetric assessment of corneal shape.
Resumo:
Purpose: To examine the objective clinical performance of ‘comfort-enhanced’ daily disposable contact lenses over a 16-h day. Methods: Four contact lenses (Hilafilcon B, Etafilcon A Plus, Nelfilcon A and Nelfilcon A Plus) were evaluated in an investigator masked, open label trial at the end of a week’s bilateral wear. Pre-lens noninvasive tear break-up time (PL-NITBUT), tear prism height, bulbar hyperaemia and ocular surface temperature (OST) were measured with the lens in situ at 8, 12 and 16 h of wear. Results: There was no difference between how many hours the lenses types were worn each day (F = 0.90, p = 0.44). The PL-NITBUT decreased with the duration of daily lens wear (F = 32.0, p < 0.001) and was more stable with Nelfilcon A Plus (F = 6.00, p = 0.002) than with the other lenses evaluated. Bulbar blood vessels increased in coverage (F = 11.5, p < 0.001) but not overall redness (F = 0.0, p = 0.99) with the duration of daily lens wear, but there was no difference between the lenses (p > 0.05). The tear prism height decreased with the duration of daily wear (F = 27.0, p < 0.001) and differed between lenses (F = 2.9, p = 0.04). The OST decreased with the duration of lens wear (F = 119.7, p < 0.001) and was reduced by daily disposable lens wear (F = 7.88, p < 0.001), but did not differ between lenses (F = 0.88, p = 0.45). Conclusions: Objective measures of tear film indicated a difference between the lenses evaluated for PLNITBUT and tear prism height, but not for wearing time or bulbar conjunctival hyperaemia. Therefore clinical benefits of daily disposable ‘comfort enhancing’ contact lenses can be measured, but challenges remain in producing contact lenses that do not compromise anterior eye physiology over the whole day. 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose Dry eye is a common complaint often encountered in optometric practice. However, it is a difficult condition to treat as clinical signs do not always correlate with patient symptoms. Essential fatty acids (EFA), particularly omega-3 EFA, may be effective in dealing with the underlying causes. Methods A literature review was carried out on the PubMed, ScienceDirect and Ovid databases. Searches included keywords such as ‘dry eye’, ‘essential fatty acids’ and ‘nutrition’ to find articles relating to the treatment of dry eye syndrome (DES) with omega-3 EFAs. Results Omega-3 and -6 EFAs need to be consumed together within a reasonable ratio to be effective. Currently, typical diets in developed countries lack omega-3 EFA and this results in an overexposure to omega-6. Omega-3 supplementation has an anti-inflammatory effect, inhibiting creation of omega-6 prostaglandin precursors. Omega-3 EFAs also demonstrate anti-inflammatory action in the lacrimal gland preventing apoptosis of the secretory epithelial cells. Supplementation clears meibomitis, allowing a thinner, more elastic lipid layer to protect the tear film and cornea. Conclusion Dietary supplementation of omega-3 EFA has already proven to be effective in coronary heart disease and arthritis. Safety is not a concern as it works synergistically with omega-6 in the body. Evidence suggests that supplementation with omega-3 EFA may be beneficial in the treatment and prevention of DES.
Resumo:
Soft contact lens wear has become a common phenomenon in recent times. The contact lens when placed in the eye rapidly undergoes change. A film of biological material builds up on and in the lens matrix. The long term wear characteristics of the lens ultimately depend on this process. With time distinct structures made up of biological material have been found to build up on the lens. A fuller understanding of this process and how it relates to the lens chemistry could lead to contact lenses that are better tolerated by the eye. The tear film is a complex biological fluid, it is this fluid that bathes the lens during wear. It is reasonable to suppose that it is material derived from this source that accumulates on the lens. To understand this phenomenon it was decided to investigate the make up and conformation of the protein species that are found on and in the lens. As inter individual variations in tear fluid composition have been found it is important to be able to study the proteins on a single lens. Many of the analytical techniques used in bio research are not suitable for this study because of the lack of sensitivity. Work with poly acrylamide electrophoresis showed the possibility of analyzing the proteins extracted from a single lens. The development of a biotin avidin electro-blot and an enzyme linked aniibody electro-blot, lead to the high sensitivity detection and identification of the proteins present. The extraction of proteins from a lens is always incomplete. A method that analyses the proteins in situ would be a great advancement. Fourier transform infra red microscopy was developed to a point where a thin section of a contact lens could yield information about the proteins present and their conformation. The three dimensional structure of the gross macroscopic structures termed white spots was investigated using confocal laser microscopy.
Resumo:
Generally, we like to see ageing as a process that is happening to people older than ourselves. However the process of ageing impacts on a wide range of functions within the human body. Whilst many of the outcomes of ageing can now be delayed or reduced, age-related changes in cellular, molecular and physiological functionality of tissues and organs can also influence how drugs enter, distribute and are eliminated from the body. Therefore, the changing profile of barriers to drug delivery should be considered if we are to develop more age-appropriate medicines. Changes in the drug dissolution and absorption in older patients may require the formulation of oral delivery systems that offer enhanced retention at absorption sites to improve drug delivery. Alternatively, liquid and fast-melt dosage systems may address the need of patients who have difficulties in swallowing medication. Ageing-induced changes in the lung can also result in slower drug absorption, which is further compounded by disease factors, common in an ageing population, that reduce lung capacity. In terms of barriers to drug delivery to the eye, the main consideration is the tear film, which like other barriers to drug delivery, changes with normal ageing and can impact on the bioavailability of drugs delivery using eye drops and suspensions. In contrast, whilst the skin as a barrier changes with age, no significant difference in absorption of drugs from transdermal drug delivery is observed in different age groups. However, due to the age-related pharmacokinetic and pharmacodynamic changes, dose adaptation should still be considered for drug delivery across the skin. Overall it is clear that the increasing age demographic of most populations, presents new (or should that be older) barriers to effective drug delivery. © 2012 Elsevier B.V. All rights reserved.
Resumo:
The thesis investigates the ocular response to silicone-hydrogel (SiH) contact lens wear, a relatively new contact lens material that has a higher modulus of rigidity and different surface coating than used in conventional hydrogel materials. The properties of SiH materials differ significantly from conventional hydrogels and, using subjective and objective means of assessment, the thesis examines how these properties affect reflection and biometry, ocular physiology, tear film characteristics, symptomatology, adverse events and complications. A range of standard and newly designed investigative techniques were employed, and latter involving novel imaging techniques, for the objective assessment of physiological changes which occur with contact lens wear. The study is the first to combine these techniques with biochemical analyses of the tear film composition. Forty-seven subjects were fitted with SiH lenses and randomly allocated to one of the two materials currently on the market (Lotrafilcon A or Balafilcon A) on an either daily or continuous wear basis. An additional control group of 14 age-matched non-contact lens wearers were monitored over the same period. Measurements were taken before and 1, 3, 6, 12 and 18 months after initial fitting. The findings reported in this thesis will enable contact lens practitioners and manufacturers to understand further the optical, physiological and biochemical nature of the ocular response to SiH contact lenses and hence facilitate the development of this important generation of contact lens material.
Resumo:
The ability to measure ocular surface temperature (OST) with thermal imaging offers potential insight into ocular physiology that has been acknowledged in the literature. The TH7102MX thermo-camera (NEC San-ei, Japan) continuously records dynamic information about OST without sacrificing spatial resolution. Using purpose-designed image analysis software, it was possible to select and quantify the principal components of absolute temperature values and the magnitude plus rate of temperature change that followed blinking. The techniques was examined for repeatability, reproducibility and the effects of extrinsic factors: a suitable experimental protocol was thus developed. The precise source of the measured thermal radiation has previously been subject toe dispute: in this thesis, the results of a study examining the relationships between physical parameters of the anterior eye and OST, confirmed a principal role for the tear film in OST. The dynamic changes in OST were studied in a large group of young subjects: quantifying the post-blink changes in temperature with time also established a role for tear flow dynamics in OST. Using dynamic thermography, the effects of hydrogel contact lens wear on OST were investigated: a model eye for in vivo work, and both neophyte and adapted contact lens wearers for in vivo studies. Significantly greater OST was observed in contact lens wearers, particularly with silicone hydrogel lenses compared to etafilcon A, and tended to be greatest when lenses had been worn continuously. This finding is important to understanding the ocular response to contact lens wear. In a group of normal subjects, dynamic thermography appeared to measure the ocular response to the application of artificial tear drops: this may prove to be a significant research and clinical tool.
Resumo:
The present thesis evaluates various aspects of videokeratoscopes, which are now becoming increasingly popular in the investigation of corneal topography. The accuracy and repeatability of these instruments has been assessed mainly using spherical surfaces, however, few studies have assessed the performance of videokeratoscopes in measuring convex aspheric surfaces. Using two videokeratoscopes, the accuracy and repeatability of measurements using twelve aspheric surfaces is determined. Overall, the accuracy and repeatability of both instruments were acceptable, however, progressively flatter surfaces introduced greater errors in measurement. The possible reasons for these errors are discussed. The corneal surface is a biological structure lubricated by the precorneal tear film. The effects of variations in the tear film on the repeatability of videokeratoscopes have not been determined in terms of peripheral corneal measurements. The repeatability of two commercially available videokeratoscopes is assessed. The repeatability is found to be dependent on the point of measurement on the corneal surface. Typically, superior and nasal meridians exhibit poorest repeatability. It is suggested that interference of the ocular adnexa is responsible for the reduced repeatability. This localised reduction in repeatability will occur for all videokeratoscopes. Further, comparison with the keratometers and videokeratoscopes used show that measurements between these instruments are not interchangeable. The final stage of this thesis evaluates the performance of new algorithms. The characteristics of a new videokeratoscope are described. This videokeratoscope is used to test the accuracy of the new algorithms for twelve aspheric surfaces. The new algorithms are accurate in determining the shape of aspheric surfaces, more so than those algorithms proposed at present.
Resumo:
Purpose: Lipids play a vital role at interfaces such as the tear film in the protection of the anterior eye. Their role is to act as lubricants and reduce surface and interfacial tension. Although there is a lack of appropriate methods to solubilize and dilute phospholipids to the tear film. Here, we report that styrene-maleic acid copolymers (PSMA), can form polymer–lipid complexes in the form of monodisperse nanometric particles, which can easily solubilise these phospholipid molecules by avoiding for example, the use of any kind of surfactant. Method: The interactions of PSMA with phospholipids have been studied by its adsorption from aqueous solutions into monolayers of dimyristoyl-phosphorylcholine (DMPC). The Langmuir trough (LT) technique is used to study this pH-dependant complex formation. The formed nanoparticles have been also analysed by 31P NMR, particle size distribution by light scattering (DLS) and morphology by electron microscopy (SEM). Results: The LT has been found to be a useful technique for in vitro simulation of in vivo lipid layer behaviour: The limiting surface pressure of unstable tear films ranges between 20 and 30 mN/m. More stable tear films show an increase in surface pressure, within the range of 35–45 mN/m. The DMPC monolayers have a limiting surface pressure of 38 mN/m (water), and 45 mN/m (pH 4 buffer), and the PSMA-DMPC complexes formed at pH 4 have a value of 42 mN/m, which resembles that of the stable tear film. The average particle size distribution is 53 ± 10 nm with a low polydispersity index (PDI) of 0.24 ± 0.03. Conclusions: New biocompatible and cheap lipid solubilising agents such as PSMA can be used for the study of the tear film composition and properties. These polymer–lipid complexes in the form of nanoparticles can be used to solubilise and release in a controlled way other hydrophobic molecules such as some drugs or proteins.
Resumo:
AIM: To determine the validity and reliability of the measurement of corneal curvature and non-invasive tear break-up time (NITBUT) measures using the Oculus Keratograph. METHOD: One hundred eyes of 100 patients had their corneal curvature assessed with the Keratograph and the Nidek ARKT TonorefII. NITBUT was then measured objectively with the Keratograph with Tear Film Scan software and subjectively with the Keeler Tearscope. The Keratograph measurements of corneal curvature and NITBUT were repeated to test reliability. The ocular sensitivity disease index questionnaire was completed to quantify ocular comfort. RESULTS: The Keratograph consistently measured significantly flatter corneal curvatures than the ARKT (MSE difference: +1.83±0.44D), but was repeatable (p>0.05). Keratograph NITBUT measurements were significantly lower than observation using the Tearscope (by 12.35±7.45s; pp < 0.001) and decreased on subsequent measurement (by -1.64 ± 6.03s; p < 0.01). The Keratograph measures the first time the tears break up anywhere on the cornea with 63% of subjects having NI-TBUT's <5s and a further 22% having readings between 5 and 10s. The Tearscope results were found to correlate better with the patients symptoms (r = -0.32) compared to the Keratograph (r = -0.19). Conclusions: The Keratograph requires a calibration off-set to be comparable to other keratometry devices. Its current software detects very early tear film changes, recording significantly lower NITBUT values than conventional subjective assessment. Adjustments to instrumentation software have the potential to enhance the value of Keratograph objective measures in clinical practice.
Resumo:
The principle theme of this thesis is the advancement and expansion of ophthalmic research via the collaboration between professional Engineers and professional Optometrists. The aim has been to develop new and novel approaches and solutions to contemporary problems in the field. The work is sub divided into three areas of investigation; 1) High technology systems, 2) Modification of current systems to increase functionality, and 3) Development of smaller more portable and cost effective systems. High Technology Systems: A novel high speed Optical Coherence Tomography (OCT) system with integrated simultaneous high speed photography was developed achieving better operational speed than is currently available commercially. The mechanical design of the system featured a novel 8 axis alignment system. A full set of capture, analysis, and post processing software was developed providing custom analysis systems for ophthalmic OCT imaging, expanding the current capabilities of the technology. A large clinical trial was undertaken to test the dynamics of contact lens edge interaction with the cornea in-vivo. The interaction between lens edge design, lens base curvature, post insertion times and edge positions was investigated. A novel method for correction of optical distortion when assessing lens indentation was also demonstrated. Modification of Current Systems: A commercial autorefractor, the WAM-5500, was modified with the addition of extra hardware and a custom software and firmware solution to produce a system that was capable of measuring dynamic accommodative response to various stimuli in real time. A novel software package to control the data capture process was developed allowing real time monitoring of data by the practitioner, adding considerable functionality of the instrument further to the standard system. The device was used to assess the accommodative response differences between subjects who had worn UV blocking contact lens for 5 years, verses a control group that had not worn UV blocking lenses. While the standard static measurement of accommodation showed no differences between the two groups, it was determined that the UV blocking group did show better accommodative rise and fall times (faster), thus demonstrating the benefits of the modification of this commercially available instrumentation. Portable and Cost effective Systems: A new instrument was developed to expand the capability of the now defunct Keeler Tearscope. A device was developed that provided a similar capability in allowing observation of the reflected mires from the tear film surface, but with the added advantage of being able to record the observations. The device was tested comparatively with the tearscope and other tear film break-up techniques, demonstrating its potential. In Conclusion: This work has successfully demonstrated the advantages of interdisciplinary research between engineering and ophthalmic research has provided new and novel instrumented solutions as well as having added to the sum of scientific understanding in the ophthalmic field.