987 resultados para Subtraction radiography
Resumo:
Considering that ionizing radiation effects are cumulative and the gonads are particularly sensitive to these effects, and also the clinical importance of pelvic radiographs in children, the excess of radiation exposure to the gonads must be avoided. The purpose of this study is to demonstrate the relevance of the correct use of gonad protection shields and to evaluate their use on the hip radiographs performed in a reference clinical institution, through the retrospective analysis of pelvic radiographic images performed in children. According the image quality assessment, 20 (40%) patients were unprotected and gonads shields were incorrectly placed in 24 (80%) patients.
Resumo:
The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.
Resumo:
This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.
Resumo:
Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)
Resumo:
All patients having undergone a coronarography during 1984 have been surveyed in Switzerland. This retrospective study has used existing data in the 13 centers practicing this diagnostic procedure. 4921 coronarographies were carried out in 1984, amongst 4359 patients. In terms of population-based rates, the national figures are 77 procedures/100,000 residents, and 68 patients/100,000 residents. Female rates are one fourth of the male rates (27/100,000 versus 112/100,000). For both sexes, the highest utilization rates are for the age groups 60-64. Swiss figures are relatively low when compared with other developed countries. However, patterns of utilization are very different within the country: according to the Canton of residence of the patient, the utilization rates (standardized for age and sex) vary from 8/100,000 to 160/100,000. There is a distinct gradient from south-west to north-east, which closely corresponds to the distribution of centers practicing the procedure. More intriguing is the fact that cardiovascular mortality shows an inverse geographical gradient, with the highest mortality in Cantons having the lowest rate of coronarography. Various reasons for the observed variations are discussed, in relation with differences in supply of diagnostic and therapeutic equipments, but also in relation with various patterns of demand related to differential morbidity rates and/or differential patterns of clinical decision.
Resumo:
It has been suggested that an inappropriate relationship between renin and exchangeable sodium is responsible for the hypertension of patients with chronic renal failure. Long-term blockade of the renin system by captopril made it possible to test this hypothesis in 8 patients on maintenance hemodialysis. Captopril was administered orally in 2 daily doses of 25 to 200 mg. Previously, blood pressure averaged 179/105 +/- 6/3 (mean +/- SEM) pre- and 182/103 +/- 7/3 mm HG post-dialysis, despite intensive ultrafiltration and conventional antihypertensive therapy. The 4 patients with the highest plasma renin activity normalized their blood pressure with captopril alone, whereas in the 4 remaining patients, captopril therapy was complemented by salt subtraction which consisted in replacement of 1-2 liters of ultrafiltrate by an equal volume of 5% dextrose until blood pressure was controlled. After an average treatment period of 5 months, blood pressure of all 8 patients was reduced to 134/76 +/- 7/5 mm Hg (P less than 0.001) pre- and 144/81 +/- 9/5 mm Hg (P less than 0.001) post-dialysis without a significant change in body weight. The present data suggest that captopril alone or combined with salt subtraction normalizes blood pressure of patients on chronic hemodialysis with so called uncontrollable hypertension.
Resumo:
Workforce Planning Review 2
Resumo:
Workforce Planning Review
Resumo:
Report of the Project Group
Resumo:
The Expert Group on Radiography Grades was established in accordance with proposals from the Labour Relations Commission. Its aim was to examine and make recommendations for the future development of the profession and the diagnostic imaging and therapy services which ensure the highest level of patient care is delivered in a modern health environment Download the Report here
Resumo:
Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.
Resumo:
OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.