975 resultados para Steam generators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the wake of an almost decade long economic downturn and increasing competition from developing economies, a new agenda in the Australian Government for science, technology, engineering, and mathematics (STEM) education and research has emerged as a national priority. However, to art and design educators, the pervasiveness and apparent exclusivity of STEM can be viewed as another instance of art and design education being relegated to the margins of curriculum (Greene, 1995). In the spirit of interdisciplinarity, there have been some recent calls to expand STEM education to include the arts and design, transforming STEM into STEAM in education (Maeda, 2013). As with STEM, STEAM education emphasises the connections between previously disparate disciplines, meaning that education has been conceptualised in different ways, such as focusing on the creative design thinking process that is fundamental to engineering and art (Bequette & Bequette, 2012). In this article, we discuss divergent creative design thinking process and metacognitive skills, how, and why they may enhance learning in STEM and STEAM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The widespread deployment of commercial-scale cellulosic ethanol currently hinges on developing and evaluating scalable processes whilst broadening feedstock options. This study investigates whole Eucalyptus grandis trees as a potential feedstock and demonstrates dilute acid pre-treatment (with steam explosion) followed by pre-saccharification simultaneous saccharification fermentation process (PSSF) as a suitable, scalable strategy for the production of bioethanol. Biomass was pre-treated in dilute H2SO4 at laboratory scale (0.1 kg) and pilot scale (10 kg) to evaluate the effect of combined severity factor (CSF) on pre-treatment effectiveness. Subsequently, pilot-scale pre-treated residues (15 wt.%) were converted to ethanol in a PSSF process at 2 L and 300 L scales. Good polynomial correlations (n = 2) of CSF with hemicellulose removal and glucan digestibility with a minimum R2 of 0.91 were recorded. The laboratory-scale 72 h glucan digestibility and glucose yield was 68.0% and 51.3%, respectively, from biomass pre-treated at 190 °C /15 min/ 4.8 wt.% H2SO4. Pilot-scale pre-treatment (180 °C/ 15 min/2.4 wt.% H2SO4 followed by steam explosion) delivered higher glucan digestibility (71.8%) and glucose yield (63.6%). However, the ethanol yields using PSSF were calculated at 82.5 and 113 kg/ton of dry biomass for the pilot and the laboratory scales, respectively. © 2016 Society of Chemical Industry and John Wiley & Sons, Ltd

Relevância:

20.00% 20.00%

Publicador:

Resumo:

n many parts of the world, the goal of electricity supply industries is always the introduction of competition and a lowering of the average consumer price. Because of this it has become much more important to be able to determine which generators are supplying a particular load, how much use each generator is making of a transmission line and what is generator's contribution to the system losses. In this paper a case study on generator contributions towards loads and transmission flows are illustrated with an equivalent 11-bus system, a part of Indian Southern Grid, based on the concepts of circuit flow directions, for normal and network contingency conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results of an investigation dealing with the behaviour of grid-connected induction generators (GCIGs) driven by typical prime movers such as mini-hydro/wind turbines are presented. Certain practical operational problems of such systems are identified. Analytical techniques are developed to study the behavior of such systems. The system consists of the induction generator (IG) feeding a 11 kV grid through a step-up transformer and a transmission line. Terminal capacitors to compensate for the lagging VAr are included in the study. Computer simulation was carried out to predict the system performance at the given input power from the turbine. Effects of variations in grid voltage, frequency, input power, and terminal capacitance on the machine and system performance are studied. An analysis of self-excitation conditions on disconnection of supply was carried out. The behavior of a 220 kW hydel system and 55/11 kW and 22 kW wind driven system corresponding to actual field conditions is discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let O be a monomial curve in the affine algebraic e-space over a field K and P be the relation ideal of O. If O is defined by a sequence of e positive integers some e - 1 of which form an arithmetic sequence then we construct a minimal set of generators for P and write an explicit formula for mu(P).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The amount of reactive power margin available in a system determines its proximity to voltage instability under normal and emergency conditions. More the reactive power margin, better is the systems security and vice-versa. A hypothetical way of improving the reactive margin of a synchronous generator is to reduce the real power generation within its mega volt-ampere (MVA) ratings. This real power generation reduction will affect its power contract agreements entered in the electricity market. Owing to this, the benefit that the generator foregoes will have to be compensated by paying them some lost opportunity cost. The objective of this study is three fold. Firstly, the reactive power margins of the generators are evaluated. Secondly, they are improved using a reactive power optimization technique and optimally placed unified power flow controllers. Thirdly, the reactive power capacity exchanges along the tie-lines are evaluated under base case and improved conditions. A detailed analysis of all the reactive power sources and sinks scattered throughout the network is carried out in the study. Studies are carried out on a real life, three zone, 72-bus equivalent Indian southern grid considering normal and contingency conditions with base case operating point and optimised results presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let K be a field of characteristic zero and let m(0),..., m(e-1) be a sequence of positive integers. Let C be an algebroid monomial curve in the affine e-space A(K)(e) defined parametrically by X-0 = T-m0,..., Xe-1 = Tme-1 and let A be the coordinate ring of C. In this paper, we assume that some e - 1 terms of m(0),..., m(e-1) form an arithmetic sequence and construct a minimal set of generators for the derivation module Der(K)(A) of A and write an explicit formula for mu (Der(K)(A)).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prime focus of this study is to design a 50 mm internal diameter diaphragmless shock tube that can be used in an industrial facility for repeated loading of shock waves. The instantaneous rise in pressure and temperature of a medium can be used in a variety of industrial applications. We designed, fabricated and tested three different shock wave generators of which one system employs a highly elastic rubber membrane and the other systems use a fast acting pneumatic valve instead of conventional metal diaphragms. The valve opening speed is obtained with the help of a high speed camera. For shock generation systems with a pneumatic cylinder, it ranges from 0.325 to 1.15 m/s while it is around 8.3 m/s for the rubber membrane. Experiments are conducted using the three diaphragmless systems and the results obtained are analyzed carefully to obtain a relation between the opening speed of the valve and the amount of gas that is actually utilized in the generation of the shock wave for each system. The rubber membrane is not suitable for industrial applications because it needs to be replaced regularly and cannot withstand high driver pressures. The maximum shock Mach number obtained using the new diaphragmless system that uses the pneumatic valve is 2.125 +/- 0.2%. This system shows much promise for automation in an industrial environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper addresses certain issues pertaining to the technology of lime-stabilised steam-cured blocks used for masonry construction. Properties of lime-stabilised steam-cured blocks using expansive soils and tank bed soils have been examined. Influence of parameters like steam curing period, lime content and fly ash content on wet strength of blocks is studied. Steam curing of lime stabilised blocks at 80degreesC for about 20 hours at atmospheric pressure leads to considerably higher strengths when compared with curing under wet cloth at ambient temperatures. Clay-fly ash fractions of the mix control the optimum lime content yielding maximum strength. Long-term strength behaviour of steam-cured blocks has been monitored. The results indicate a favourable lime-clay ratio for stable long-term strength. A small-scale steam cured block production system has been designed and implemented to construct a load bearing masonry structure, thus demonstrating the potential of steam-cured block as a material for masonry construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we study bases for projective monomial curves and the relationship between the basis and the set of generators for the defining ideal of the curve. We understand this relationship best for curves in P-3 and for curves defined by an arithmetic progression. We are able to prove that the latter are set theoretic complete intersections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper illustrates the application of a new technique, based on Support Vector Clustering (SVC) for the direct identification of coherent synchronous generators in a large interconnected Multi-Machine Power Systems. The clustering is based on coherency measures, obtained from the time domain responses of the generators following system disturbances. The proposed clustering algorithm could be integrated into a wide-area measurement system that enables fast identification of coherent clusters of generators for the construction of dynamic equivalent models. An application of the proposed method is demonstrated on a practical 15 generators 72-bus system, an equivalent of Indian Southern grid in an attempt to show the effectiveness of this clustering approach. The effects of short circuit fault locations on coherency are also investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the application of support vector clustering (SVC) for the direct identification of coherent synchronous generators in large interconnected multi-machine power systems. The clustering is based on coherency measure, which indicates the degree of coherency between any pair of generators. The proposed SVC algorithm processes the coherency measure matrix that is formulated using the generator rotor measurements to cluster the coherent generators. The proposed approach is demonstrated on IEEE 10 generator 39-bus system and an equivalent 35 generators, 246-bus system of practical Indian southern grid. The effect of number of data samples and fault locations are also examined for determining the accuracy of the proposed approach. An extended comparison with other clustering techniques is also included, to show the effectiveness of the proposed approach in grouping the data into coherent groups of generators. This effectiveness of the coherent clusters obtained with the proposed approach is compared in terms of a set of clustering validity indicators and in terms of statistical assessment that is based on the coherency degree of a generator pair.