877 resultados para Spinal flexibility
Resumo:
Flexible design concept is a relatively new trend in airport terminal design which is believed to facilitate the ever changing needs of a terminal. Current architectural design processes become more complex every day because of the introduction of new building technologies where the concept of flexible airport terminal would apparently make the design process even more complex. Previous studies have demonstrated that ever growing aviation industry requires airport terminals to be planned, designed and constructed in such a way that should allow flexibility in design process. In order to adopt the philosophy of ‘design for flexibility’ architects need to address a wide range of differing needs. An appropriate integration of the process models, prior to the airport terminal design process, is expected to uncover the relationships that exist between spatial layout and their corresponding functions. The current paper seeks to develop a way of sharing space adjacency related information obtained from the Business Process Models (BPM) to assist in defining flexible airport terminal layouts. Critical design parameters are briefly investigated at this stage of research whilst reviewing the available design alternatives and an evaluation framework is proposed in the current paper. Information obtained from various design layouts should assist in identifying and defining flexible design matrices allowing architects to interpret and to apply those throughout the lifecycle of the terminal building.
Resumo:
Presentation delivered to the Australian and New Zealand Consumer Law Roundtable held at the University of Melbourne Law School on Friday, 16 November 2012. The paper covers the background to the 'Future of Financial Advice' reforms and their context. In addition to this the scope of best interests duty is discussed. The paper concludes with an assessment of the likely effectives of best interest duty as a consumer protection measure.
Resumo:
Adolescent idiopathic scoliosis (AIS) is a three-dimensional spinal deformity involving the side-to-side curvature of the spine in the coronal plane and axial rotation of the vertebrae in the transverse plane. For patients with a severe or rapidly progressing deformity, corrective instrumented fusion surgery is performed. The wide choice of implants and large variability between patients make it difficult for surgeons to choose optimal treatment strategies. This paper describes the patient specific finite element modelling techniques employed and the results of preliminary analyses predicting the surgical outcomes for a series of AIS patients. This report highlights the importance of not only patient-specific anatomy and material parameters, but also patient-specific data for the clinical and physiological loading conditions experienced by the patient who has corrective scoliosis surgery.
Resumo:
The project investigated the relationships between diversification in modes ofdelivery, use of information and communication technologies, academics’ teaching practices, and the context in which those practices are employed, in two of the three large universities in Brisbane—Griffith University and the Queensland University of Technology (QUT). The project’s initial plan involved the investigation of two sites: Queensland University of Technology’s Faculty of Education (Kelvin Grove campus) and Griffith University’s Faculty of Humanities(Nathan campus). Interviews associated with the Faculty of Education led to a decision to include a third site—the School of Law within Queensland University of Technology’s Faculty of Law, which is based on the Gardens Point Campus. Here the investigation focused on the use of computer-based flexible learning practices, as distinct from the more text-based practices identified within the original two sites.
Resumo:
Context: The Ober and Thomas tests are subjective and involve a "negative" or "positive" assessment, making them difficult to apply within the paradigm of evidence-based medicine. No authors have combined the subjective clinical assessment with an objective measurement for these special tests. Objective: To compare the subjective assessment of iliotibial band and iliopsoas flexibility with the objective measurement of a digital inclinometer, to establish normative values, and to provide an evidence-based critical criterion for determining tissue tightness. Design: Cross-sectional study. Setting: Clinical research laboratory. Patients or Other Participants: Three hundred recreational athletes (125 men, 175 women; 250 in injured group, 50 in control group). Main Outcome Measure(s): Iliotibial band and iliopsoas muscle flexibility were determined subjectively using the modified Ober and Thomas tests, respectively. Using a digital inclinometer, we objectively measured limb position. lnterrater reliability for the subjective assessment was compared between 2 clinicians for a random sample of 100 injured participants, who were classified subjectively as either negative or positive for iliotibial band and iliopsoas tightness. Percentage of agreement indicated interrater reliability for the subjective assessment. Results: For iliotibial band flexibility, the average inclinometer angle was -24.59 degrees +/- 7.27 degrees. A total of 432 limbs were subjectively assessed as negative (-27.13 degrees +/- 5.53 degrees) and 168 as positive (-16.29 degrees +/- 6.87 degrees). For iliopsoas flexibility, the average inclinometer angle was -10.60 degrees +/- 9.61 degrees. A total of 392 limbs were subjectively assessed as negative (-15.51 degrees +/- 5.82 degrees) and 208 as positive (0.34 degrees +/- 7.00 degrees). The critical criteria for iliotibial band and iliopsoas flexibility were determined to be -23.16 degrees and -9.69 degrees, respectively. Between-clinicians agreement was very good, ranging from 95.0% to 97.6% for the Thomas and Ober tests, respectively. Conclusions: Subjective assessments and instrumented measurements were combined to establish normative values and critical criterions for tissue flexibility for the modified Ober and Thomas tests.
Resumo:
The role of inflammatory response after spinal cord injury remains unclear. This thesis was a step forward in studying how promoting the inflammation, by delivery pro-inflammatory growth factors, affects the outcomes of spinal cord injury. A significant functional improvement was observed after treatment and these results suggest an interesting avenue for future clinical treatments and may provide a platform to improve the efficacy of other treatments.
Resumo:
In this study, a treatment plan for a spinal lesion, with all beams transmitted though a titanium vertebral reconstruction implant, was used to investigate the potential effect of a high-density implant on a three-dimensional dose distribution for a radiotherapy treatment. The BEAMnrc/DOSXYZnrc and MCDTK Monte Carlo codes were used to simulate the treatment using both a simplified, recltilinear model and a detailed model incorporating the full complexity of the patient anatomy and treatment plan. The resulting Monte Carlo dose distributions showed that the commercial treatment planning system failed to accurately predict both the depletion of dose downstream of the implant and the increase in scattered dose adjacent to the implant. Overall, the dosimetric effect of the implant was underestimated by the commercial treatment planning system and overestimated by the simplified Monte Carlo model. The value of performing detailed Monte Carlo calculations, using the full patient and treatment geometry, was demonstrated.
Resumo:
Aims To integrate existing theoretical perspectives on change management, subjective fit and occupational stress to better understand the effects of change on employee adjustment. Background Although subjective fit with organizational goals and objectives has been shown to have positive effects on employee adjustment, its role in the organizational change–occupational stress context is not understood. This represents a caveat in research when considering the notion that those who feel that they fit with the organization's goals may be better equipped to reconcile and deal with change. Design A cross-sectional survey of nurses from public and non-profit sector hospitals was conducted. Method Data were collected from 252 public and non-profit sector nurses via online surveys. Data were collected from June–October in 2010. Structural equation modelling was used to test the direct and indirect effects among the focal variables. Results The results showed that public and non-profit nurses experience flexibility-limiting and flexibility-promoting change initiatives and that these are differentially related to the perception of administrative stressors and adjustment with these relationships directly and indirectly influenced by perceptions of subjective fit. Flexibility-limiting change initiatives led to lower levels of subjective fit, higher levels of administrative stressors and less favourable adjustment. On the other hand, flexibility-promoting change practices led to higher levels of subjective fit, lower levels of administrative stressors and ultimately better adjustment. Conclusion The results further the theoretical understanding of the role of subjective fit in organizational change and occupational stress theories.
Resumo:
Suspension bridges meet the steadily growing demand for lighter and longer bridges in today’s infrastructure systems. These bridges are designed to have long life spans, but with age, their main cables and hangers could suffer from corrosion and fatigue. There is a need for a simple and reliable procedure to detect and locate such damage, so that appropriate retrofitting can be carried out to prevent bridge failure. Damage in a structure causes changes in its properties (mass, damping and stiffness) which in turn will cause changes in its vibration characteristics (natural frequencies, modal damping and mode shapes). Methods based on modal flexibility, which depends on both the natural frequencies and mode shapes, have the potential for damage detection. They have been applied successfully to beam and plate elements, trusses and simple structures in reinforced concrete and steel. However very limited applications for damage detection in suspension bridges have been identified to date. This paper examines the potential of modal flexibility methods for damage detection and localization of a suspension bridge under different damage scenarios in the main cables and hangers using numerical simulation techniques. Validated finite element model (FEM) of a suspension bridge is used to acquire mass normalized mode shape vectors and natural frequencies at intact and damaged states. Damage scenarios will be simulated in the validated FE models by varying stiffness of the damaged structural members. The capability of damage index based on modal flexibility to detect and locate damage is evaluated. Results confirm that modal flexibility based methods have the ability to successfully identify damage in suspension bridge main cables and hangers.
Resumo:
The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS) which aims to harness potential growth in order to correct spinal deformity. This study compared through in-vitro experiments the biomechanical response of two different rod designs under axial rotation loading. The study showed that a new design of telescoping growing rod preserved the rotational flexibility of the spine in comparison with rigid rods indicating them to be a more physiological way to improve the spinal deformity.
Resumo:
Software to create individualised finite element (FE) models of the osseoligamentous spine using pre-operative computed tomography (CT) data-sets for spinal surgery patients has recently been developed. This study presents a geometric sensitivity analysis of this software to assess the effect of intra-observer variability in user-selected anatomical landmarks. User-selected landmarks on the osseous anatomy were defined from CT data-sets for three scoliosis patients and these landmarks were used to reconstruct patient-specific anatomy of the spine and ribcage using parametric descriptions. The intra-observer errors in landmark co-ordinates for these anatomical landmarks were calculated. FE models of the spine and ribcage were created using the reconstructed anatomy for each patient and these models were analysed for a loadcase simulating clinical flexibility assessment. The intra-observer error in the anatomical measurements was low in comparison to the initial dimensions, with the exception of the angular measurements for disc wedge and zygapophyseal joint (z-joint) orientation and disc height. This variability suggested that CT resolution may influence such angular measurements, particularly for small anatomical features, such as the z-joints, and may also affect disc height. The results of the FE analysis showed low variation in the model predictions for spinal curvature with the mean intra-observer variability substantially less than the accepted error in clinical measurement. These findings demonstrate that intra-observer variability in landmark point selection has minimal effect on the subsequent FE predictions for a clinical loadcase.
Resumo:
Inflammation of the spinal cord after traumatic spinal cord injury leads to destruction of healthy tissue. This “secondary degeneration” is more damaging than the initial physical damage and is the major contributor to permanent loss of functions. In our previous study we showed that combined delivery of two growth factors, vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF), significantly reduced secondary degeneration after hemi-section injury of the spinal cord in the rat. Growth factor treatment reduced the size of the lesion cavity at 30d compared to control animals and further reduced the cavity at 90d in treated animals while in control animals the lesion cavity continued to increase in size. Growth factor treatment also reduced astrogliosis and reduced macroglia/macrophage activation around the injury site. Treatment with individual growth factors alone had similar effects to control treatments. The present study investigated whether growth factor treatment would improve locomotor behaviour after spinal contusion injury, a more relevant preclinical model of spinal cord injury. The growth factors were delivered for the first 7d to the injury site via osmotic minipump. Locomotor behaviour was monitored at 1-28d after injury using the BBB score and at 30d using automated gait analysis. Treated animals had BBB scores of 18; Control animals scored 10. Treated animals had significantly reduced lesion cavities and reduced macroglia/macrophage activation around the injury site. We conclude that growth factor treatment preserved spinal cord tissues after contusion injury, thereby allowing functional recovery. This treatment has the potential to significantly reduce the severity of human spinal cord injuries.
Resumo:
A procurement decision-making model is developed based on a novel integration of leading-edge microeconomic theory and empirically tested in major road and health projects. The model provides a more reliable approach to identifying projects suited to Public-Private-Partnerships (PPPs) and it is expected that the model will enable government to deliver improved value-for-money from their portfolio of PPP projects.
Resumo:
INTRODUCTION Managing spinal deformities in young children is challenging, particularly early onset scoliosis (EOS). Surgical intervention is often required if EOS has been unresponsive to conservative treatment particularly with rapidly progressive curves. An emerging treatment option for EOS is fusionless scoliosis surgery. Similar to bracing, this surgical option potentially harnesses growth, motion and function of the spine along with correcting spinal deformity. Dual growing rods are one such fusionless treatment, which aims to modulate growth of the vertebrae. The aim of this study was to ascertain the extent to which semiconstrained growing rods (Medtronic, Sofamor, Danek, Memphis, TN) with a telescopic sleeve component, reduce rotational constraint on the spine compared with standard "constrained / rigid" rods and hence potentially provide a more physiological mechanical environment for the growing spine. METHODS Six 40-60kg English Large White porcine spines served as a model for the paediatric human spine. Each spine was dissected into a 7 level thoracolumbar multi-segment unit (MSU), removing all non-ligamentous soft tissues and leaving 3cm of ribs either side. Pure nondestructive axial rotation moments of ±4Nm at a constant rotation rate of 8deg.s-1 were applied to the mounted MSU spines using a biaxial Instron testing machine. Displacement of each vertebral level was captured using a 3D motion tracking system (Optotrak 3020, Northern Digital Inc, Waterloo, ON). Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained growing rods and rigid rods in alternating sequence. The rods were secured by multi-axial pedicle screws (Medtronic CD Horizon) at levels 2 and 6 of the construct. The range of motion (ROM), neutral zone (NZ) size and stiffness (Nm.deg-1) were calculated from the Instron load-displacement data and intervertebral ROM was calculated through a MATLAB algorithm from Optotrak data. RESULTS Irrespective of the order of testing, rigid rods significantly reduced the total ROM compared with semi-constrained rods (p<0.05) with in a significantly stiffer spine for both left and right axial rotation (p<0.05). Analysing the intervertebral motion within the instrumented levels 2-6, rigid rods showed reduced ROM compared with semi-constrained growing rods and compared with un-instrumented motion segments. CONCLUSION Semi-constrained growing rods maintain similar stiffness in axial rotation to un-instrumented spines, while dual rigid rods significantly reduce axial rotation. Clinically the effect of semi-constrained growing rods as observed in this study is that they would be expected to allow growth via the telescopic rod components while maintaining the axial flexibility of the spine, which may reduce occurrence of the crankshaft phenomenon.