939 resultados para Sonic and ultrasonic device
Resumo:
BACKGROUND AND AIMS: little is known regarding the reproducibility of body fat measuring devices; hence, we assessed the between and within-device reproducibility, and the within-day variability of body fat measurements. METHODS: body fat percentage was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 ± 2.5 kg/m2 (mean ± SD) using seven bipolar bioelectrical impedance devices. Each participant was also measured each hour between 7:00 and 22:00. RESULTS: the correlation between first and second measurements was very high (Spearman r between 0.985 and 1.000, p<0.001), as well as between devices (Spearman r between 0.916 and 0.991, p<0.001). Repeated measurements analysis showed no differences were between devices (p=0.59) or readings (first vs. second: p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon (F test for repeated values= 6.58, p<0.001). CONCLUSIONS: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
Malnutrition, a risk factor for osteoporotic fractures, is frequent in elderly people and, is underdiagnosed and undertreated. There are only few studies on the nutritional status of elderly people in Europe. The Mini Nutritional Assessment (MNA) is a non invasive and validated questionnaire to evaluate nutritional status in elderly people, classified in three groups: 1 degree score < 17: malnourished, 2 degrees score >17 and < 24: at risk of malnutrition, 3 degrees score >24: well-nourished, with a maximum of 30 points. Quantitative ultrasound of bone (QUS) is a method for assessing quality of bone which can be easily performed in nursing homes. Therefore, these two tests allowed to study the relationships between nutritional status and ultrasonic parameters of bone in 78 institutionalized women aged 86 +/- 6 years, living in 11 nursing homes around Lausanne (Switzerland). All were assessed by the MNA, had a measurement of the tricipital skin fold and of the grip strength. Functional status was evaluated by the scale "Activity of Daily Living" (ADL), and serum albumin level was measured when permitted. All had QUS of the calcaneus (with an Achilles, GE Lunar). The measured parameters are the Broadband Ultrasound Attenuation (BUA), attenuation of a band of ultrasonic frequencies through the medium, expressed in dB/MHz, and the Speed of Sound (SOS), speed of the ultrasounds through the medium, expressed in m/s. A third parameter, the stiffness index (SI), expressed as a percentage of the values obtained by the manufacturer in a young population and derived from BUA and SOS, was calculated automatically : SI = (0.67xBUA) + (0.28xSOS) - 420, expressed in percent compared to a young adult population (%YA). Fifteen percent of the women were undernourished and 58% were at risk of malnutrition. As expected, compared with the well-nourished minority, undernourished subjects had significant lower body mass index (BMI), tricipital skin fold (TSF), ADL score and albumin level (p < 0,01). The subjects "at risk of malnutrition" had significant lower BMI, ADL score (p < 0.01), tricipital skin fold and serum albumin (p < 0.05). Ultrasound parameters were low independently of the nutritional status. MNA score correlated significantly with tricipital skin fold (r = 0.508, p < 0.01), ADL (r = 0.538, p < 0.01) and albumin serum level (r = 0.409, p = 0.01). There was a trend for a correlation between the MNA and the ultrasound parameter BUA (r = 0.207, p = 0.07), whereas no correlation was found with SOS and SI. A multivariate analysis showed that tricipital skin fold and ADL explained 61% of the variance of the MNA. In conclusion, using simple and non invasive methods, this study showed that malnutrition and osteoporosis are frequent in institutionalized elderly persons in our country, and the ultrasound parameters are influenced by many others factors in addition to nutrition, especially at this age and in elderly residents of nursing homes.
Resumo:
Objective: to assess the between and within-device reproducibility, as well as within-day variability of body fat measurements. Methods: body fat percentage (%BF) was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 22.6 kg/m2 (mean SD) using seven bipolar bioelectrical impedance devices (BF-306) according to the manufacturer's recommendations. Each student was also measured each hour between 7:00 and 22:00. Statistical analysis was conducted using a general linear model for repeated measurements. Results: the correlation between first and second measurements was very high (Pearson r between 0.985 and 1.000, p<0.001), as well as the correlation between devices (Pearson r between 0.986 and 0.999, all p<0.001). Repeated measurements analysis showed no differences were between devices (F test=0.83, p=0.59) or readings (first vs. second: F test=0.12, p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon. Assuming an overall daily average of 100 (based on all measurements), the values were 95.8 3.2 (mean SD) at 8:00 versus 101.3 3.0 at 20:00, corresponding to a mean change of 2.2 1.1 in %BF (F test for repeated values=6.58, p<0.001). Conclusions: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Differential scanning calorimetry (DSC) was used to study the dehydrogenation processes that take place in three hydrogenated amorphous silicon materials: nanoparticles, polymorphous silicon, and conventional device-quality amorphous silicon. Comparison of DSC thermograms with evolved gas analysis (EGA) has led to the identification of four dehydrogenation processes arising from polymeric chains (A), SiH groups at the surfaces of internal voids (A'), SiH groups at interfaces (B), and in the bulk (C). All of them are slightly exothermic with enthalpies below 50 meV/H atoms , indicating that, after dissociation of any SiH group, most dangling bonds recombine. The kinetics of the three low-temperature processes [with DSC peak temperatures at around 320 (A),360 (A'), and 430°C (B)] exhibit a kinetic-compensation effect characterized by a linea relationship between the activation entropy and enthalpy, which constitutes their signature. Their Si-H bond-dissociation energies have been determined to be E (Si-H)0=3.14 (A), 3.19 (A'), and 3.28 eV (B). In these cases it was possible to extract the formation energy E(DB) of the dangling bonds that recombine after Si-H bond breaking [0.97 (A), 1.05 (A'), and 1.12 (B)]. It is concluded that E(DB) increases with the degree of confinement and that E(DB)>1.10 eV for the isolated dangling bond in the bulk. After Si-H dissociation and for the low-temperature processes, hydrogen is transported in molecular form and a low relaxation of the silicon network is promoted. This is in contrast to the high-temperature process for which the diffusion of H in atomic form induces a substantial lattice relaxation that, for the conventional amorphous sample, releases energy of around 600 meV per H atom. It is argued that the density of sites in the Si network for H trapping diminishes during atomic diffusion
Resumo:
BACKGROUND: Higher nighttime blood pressure (BP) and the loss of nocturnal dipping of BP are associated with an increased risk for cardiovascular events. However, the determinants of the loss of nocturnal BP dipping are only beginning to be understood. We investigated whether different indicators of physical activity were associated with the loss of nocturnal dipping of BP. METHODS: We conducted a cross-sectional study of 103 patients referred for 24-hour ambulatory monitoring of BP. We measured these patients' step count (SC), active energy expenditure (AEE), and total energy expenditure simultaneously, using actigraphs. RESULTS: In our study population of 103 patients, most of whom were hypertensive, SC and AEE were associated with nighttime systolic BP in univariate (SC, r = -0.28, P < 0.01; AEE, r = -0.20, P = 0.046) and multivariate linear regression analyses (SC, coefficient beta = -5.37, P < 0.001; AEE, coefficient beta = -0.24, P < 0.01). Step count was associated with both systolic (r = 0.23, P = 0.018) and diastolic (r = 0.20, P = 0.045) BP dipping. Nighttime systolic BP decreased progressively across the categories of sedentary, moderately active, and active participants (125mm Hg, 116mm Hg, 112mm Hg, respectively; P = 0.002). The degree of BP dipping of BP increased progressively across the same three categories of activity (respectively 8.9%, 14.6%, and 18.6%, P = 0.002, for systolic BP and respectively 12.8%, 18.1%, and 22.2%, P = 0.006, for diastolic BP). CONCLUSIONS: Step count is continuously associated with nighttime systolic BP and with the degree of BP dipping independently of 24-hour mean BP. The combined use of an actigraph for measuring indicators of physical activity and a device for 24-hour measurement of ambulatory BP may help identify patients at increased risk for cardiovascular events in whom increased physical activity toward higher target levels may be recommended.
Resumo:
Introduction: Quantification of daily upper-limb activity is determinant in the evaluation of shoulder surgery. For a number of shoulder diseases, roblems in performing daily activities have been expressed in terms of upper-limb usage. Althought many instruments measure upper-limb movements, there is no accepted standard or widely used objective measure and no device to differenciate left or right shoulder usage. We present an objective method to measure the mobility and quantify the usage of dominant and healthy or painfull shoulder movement during daily life. Methods: 12 patients with unilateral pathological shoulder (rotator cuff disease) are compared to 18 control subjects (10 right and 8 left handed). Both SST and DASH questionnaires were completed by each one. Three inertial miniature modules including triaxial gyroscopes and accelerometers were fixed on the dorsal side of both humerus, and on the thorax. An ambulatory datalogger have recorded the signals during one day. Results: We observed that right handed healthy subjects used 18% and 26% more their dominant shoulder during respectively stand and sit postures while left handed subjects used 8% and 18% more their left side. In walking periods, shoulder mobility was quite alike for both sides. Patients affected on their dominant arm (PD group) mostly used their non-dominant side (respectively 5% and 9% during stand and sit). For the patients affected on their non-dominant shoulder (PND group), this difference is respectively 28% and 26%. Moreover, we can note that, during walking periods, a difference can be observed (on the contrary to controls). Patients used 13% and 15% more their nonpathologic side respectively for PD and PND groups. Conclusion: Inertial sensors, during long-term ambulatory monitoring of upper limbs, can quantify the difference between dominant and nondominant sides. Patients used more their non affected shoulder during daily life. For the PD group, the difference with control can be shown during walking. These results are very encouraging for future evaluation of patients with shoulder injuries since it can provide an objective evaluation of the shoulder mobility and of the treatment outcome during daily life.
Resumo:
The calculation of elasticity parameters by sonic and ultra sonic wave propagation in saturated soils using Biot's theory needs the following variables : forpiation density and porosity (p, ø), compressional and shear wave velocities (Vp, Vs), fluid density, viscosity and compressibility (Pfi Ilfi Ki), matrix density and compressibility (p" K), The first four parameters can be determined in situ using logging probes. Because fluid and matrix characteristics are not modified during core extraction, they can be obtained through laboratory measurements. All parameters necessitate precise calibrations in various environments and for specific range of values encountered in soils. The slim diameter of boreholes in shallow geophysics and the high cost of petroleum equipment demand the use of specific probes, which usually only give qualitative results. The measurement 'of density is done with a gamma-gamma probe and the measurement of hydrogen index, in relation to porosity, by a neutron probe. The first step of this work has been carried out in synthetic formations in the laboratory using homogeneous media of known density and porosity. To establish borehole corrections different casings have been used. Finally a comparison between laboratory and in situ data in cored holes of known geometry and casing has been performed.
Resumo:
A new high-precision ultrasonic device was developed to determine noninvasively arterial compliance as a function of blood pressure. Because of the nonlinear elastic properties of arterial walls, measurements of compliance can be appropriately compared only if obtained over a range of pressures. This apparatus was used to evaluate in a double-blind, parallel fashion the effect of three different antihypertensive drugs and of a placebo on radial artery compliance. Thirty-two normotensive volunteers were randomly allocated to an 8-day, once-a-day oral treatment with either a placebo, 100 mg atenolol, 20 mg nitrendipine, or 20 mg lisinopril. Blood pressure, heart rate, radial artery diameter, and arterial compliance were measured immediately before as well as 6 hours after dosing on the first and last days of the study. On the eighth day of administration, within 6 hours after dosing, lisinopril induced an acute increase in radial artery diameter, from 2.99 +/- 0.06 to 3.28 +/- 0.09 mm (mean +/- SEM, p less than 0.01). The compliance-pressure curve was shifted upward on day 1 (p less than 0.01) as well as on day 8 (p less than 0.05). None of the other drugs induced any significant modification of these parameters. Arterial compliance has a strong nonlinear dependency on intra-arterial pressure and therefore has to be defined as a function of pressure. Antihypertensive drugs acting by different mechanisms may have different effects on the mechanical properties of large arteries.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Työn tavoitteena oli selvittää mitä käsittelyvaihtoehtoja on olemassa jäteveden puhdistamon tertiäärikäsittelyyn ja miten suuri tarve paperi- ja selluteollisuuden prosessivesien puhdistukseen on. Tarkoituksena oli saada käsitys koko tertiäärikäsittelystä eri näkökulmista. Lopuksi läpikäytiin tertiäärikäsittelymenetelmiä ja etsittiin mahdollisia uusia menetelmiä, joita voitaisiin käyttää jäteveden tertiääripuhdistukseen. Ensimmäisenä työssä on perehdytty jäteveden koostumukseen paperi- ja selluteollisuudessa ja puhdistukseen ilmastetulla aktiivilietemenetelmällä, jotta tertiäärikäsittely ymmärrettäisiin konseptina paremmin. Lisäksi työssä selvitettiin tertiäärikäsittelyn tarvetta ja vaihtoehtoja sen käyttämättä jättämiselle teollisuuden ja muun ympäristöä vahingoittavan toiminnan ympäristönäkökohdat huomioonottaen. Lyhyiden menetelmäesitysten jälkeen kiteytetään tertiäärikäsittelyn ympäristönäkökohdatja vaihtoehdot sen käytölle yhteenvetona, jossa otetaan huomioon myös viranomaisten, yrityksen ja BAT referenssien sisältämä tieto tertiäärikäsittelystä. Työn kokeellinen osa sisältää erään tertiäärikäsittelysovelluksenrakentamisen, koekäytön ja laboratorioanalyysien yhteenvedon. Lisäksi menetelmää verrataan kustannus-tehokkuudeltaan vastaavien menetelmien kanssa. Tarkoituksena oli löytää jäteveden tertiäärikäsittelyyn sopiva laitteisto, jonka toimintaanei sisältyisi kemikaalien annostelua ja sitä käytettäisiin lähinnä jätevedenpuhdistamon ongelmatilanteiden väliaikaiseksi ratkaisuksi. Mahdollisesti se voisi toimia myös jatkuvatoimisesti veden kirkastuksessa. Diplomityössä rakennettu laitteisto, jota käytettiin myös pilot koeajoissa, ei ollut paras mahdollinen laitteisto tertiäärikäsittelyn toteuttamiseksi paperi- ja selluteollisuudessa, mutta kilpailukykyinen muiden laitteistojen kanssa. Laitteiston toimintaperiaate on kuitenkin käyttökelpoinen tietyin varauksin ja sitä voidaan käyttää vedenpuhdistamiseen.
Resumo:
Introduction: « Osteo-Mobile Vaud » is a mobile osteoporosis (OP) screening program. The women > 60 years living in the region Vaud will be offered OP screening with new equipment installed in a bus. The main goal is to evaluate the fracture risk with the combination of clinical risk factors (CRF) and informations extracted by a single DXA: bone mineral density (BMD), vertebral fracture assessment (VFA), and micro-architecture (MA) evaluation. MA is yet evaluable in daily practice by the Trabecular Bone Score (TBS) measure. TBS is a novel grey-level texture measurement reflecting bone MA based on the use of experimental variograms of 2D projection images. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis value, partially independent of CRF and BMD. A 55-years follow- up is planned. Method: The Osteo-Mobile Vaud cohort (1500 women, > 60 years, living in the region Vaud) started in July 2010. CRF for OP, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded. Preliminary results are reported. Results: In July 31th, we evaluated 510 women: mean age 67 years, BMI 26 kg/m². 72 women had one or more fragility fractures, 39 had vertebral fracture (VFx) grade 2/3. TBS decreases with age (-0.005 / year, p<0.001), and with BMI (-0.011 per kg/m², p<0.001). Correlation between BMD and site matched TBS is low (r=0.4, p<0.001). For the lowest T-score BMD, odds ratio (OR, 95% CI) for VFx grade 2/3 and clinical OP Fx are 1.8 (1.1-2.9) and 2.3 (1.5-3.4). For TBS, age-, BMI- and BMD adjusted ORs (per SD decrease) for VFx grade 2/3 and clinical OP Fx are 1.9 (1.2-3.0) and 1.8 (1.2-2.7). The TBS added value was independent of lumbar spine BMD or the lowest T-score (femoral neck, total hip or lumbar spine). Conclusion: As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS and BMD may increase significantly the identification of women with prevalent OP Fx. For the first time we are able to have complementary information about fracture (VFA), density (BMD), and micro-architecture (TBS) from a simple, low ionizing radiation and cheap device: DXA. The value of such informations in a screening program will be evaluated.
Resumo:
PURPOSE: To evaluate the clinical characteristics of the 3 classifications of vitreous seeds in retinoblastoma-dust (class 1), spheres (class 2), and clouds (class 3)-and their responses to intravitreal melphalan. DESIGN: Retrospective, bi-institutional cohort study. PARTICIPANTS: A total of 87 patient eyes received 475 intravitreal injections of melphalan (median dose, 30 μg) given weekly, a median of 5 times (range, 1-12 times). METHODS: At presentation, the vitreous seeds were classified into 3 groups: dust, spheres, and clouds. Indirect ophthalmoscopy, fundus photography, ultrasonography, and ultrasonic biomicroscopy were used to evaluate clinical response to weekly intravitreal melphalan injections and time to regression of vitreous seeds. Kaplan-Meier estimates of time to regression and ocular survival, patient survival, and event-free survival (EFS) were calculated and then compared using the Mantel-Cox test of curve. MAIN OUTCOME MEASURES: Time to regression of vitreous seeds, patient survival, ocular survival, and EFS. RESULTS: The difference in time to regression was significantly different for the 3 seed classes (P < 0.0001): the median time to regression was 0.6, 1.7, and 7.7 months for dust, spheres, and clouds, respectively. Eyes with dust received significantly fewer injections and a lower median and cumulative dose of melphalan, whereas eyes with clouds received significantly more injections and a higher median and cumulative dose of melphalan. Overall, the 2-year Kaplan-Meier estimates for ocular survival, patient survival, and EFS (related to target seeds) were 90.4% (95% confidence interval [CI], 79.7-95.6), 100%, and 98.5% (95% CI, 90-99.7), respectively. CONCLUSIONS: The regression and response of vitreous seeds to intravitreal melphalan are different for each seed classification. The vitreous seed classification can be predictive of time to regression, number, median dose, and cumulative dose of intravitreal melphalan injections required.
Resumo:
Tämän työn tarkoitus on seuloa oleelliset prosessiparametrit superkondensaattoreiden elektrodikomposiittien valmistuksessa, jotka vaikuttavat kondensaattorin laatuun. Tarkoitus on tutkia parametreja, joiden avulla prosessia on mahdollista optimoida. Työn tarkoituksena on tutkia myös itse komponenttimateriaalien valmistusvaiheen sekoitusprosessia mitatulla ja laskennallisella seokseen siirtyvällä tehonkulutuksella. Työn kirjallisuusosassa esitetään superkondensaattoreiden rakennetta, toimintamekanismia ja ominaisuuksia sähköenergian varastoijana. Lisäksi tarkastellaan tavallisimpia kondensaattoreihin sisältyviä materiaaleja, erityisesti hiilinanoputkia ja selluloosakuituja. Sekoitusprosesseista tarkastellaan kokeellisessa osassa käytettävien sekoituslaitteita ja niiden toimintamekanismeja komponenttien sekoitusprosesseissa. Kokeellisessa osassa tutkimuskysymyksiksi asetettiin eri sekoitusparametrien (materiaalin määrä ja laatu sekä sekoitusajat) vaikutus superkondensaattorien elektrodiarkkien ominaiskapasitansseihin. Testit suoritettiin LUT Prosessien laboratoriossa, ja testeissä massojen sekoitukseen käytettiin roottoristaattoria ja ultraäänisekoitinta. Lisäksi tutkittiin prosessin skaalausta varten skaalatulla laitteistolla sekoitettuja massanäytteitä. Sekoitusprosessin riittävyyttä varten tutkittiin kokeellisesti käytettyjen sekoituslaitteiden tehonkulutusta. Lisäksi roottoristaattorille tehtiin laskentaohjelmalla virtaussimulaatio paikallisen tehonkulutuksen selvittämiseksi Testeissä todettiin tutkittujen parametrien vaikutus, mutta tulosten perusteella varsinaista optimointia ei kyetty tekemään. Tulokset kuitenkin antavat suunnan, johon prosessia voi optimointia varten kehittää. Myös sekoitukseen todettiin siirtyvän suuri määrä tehoa tutkituilla laitteilla, mitä voidaan pitää mahdollisesti riittävänä käytettyjen komponenttien sekoitukseen.
Resumo:
The present study has both theoretical and practical aspects. The theoretical intent of the study was to closely examine the relationship between muscle activity (EMG) and EEG state during the process of falling asleep. Sleep stages during sleep onset (SO) have been generally defined with regards to brain wave activity (Recht schaff en & Kales (1968); and more precisely by Hori, Hayashi, & Morikawa (1994)). However, no previous study has attempted to quantify the changes in muscle activity during this same process. The practical aspect of the study examined the reliability ofa commercially developed wrist-worn alerting device (NovAlert™) that utilizes changes in muscle activity/tension in order to alert its user in the event that he/she experiences reduced wakefulness that may result in dangerous consequences. Twelve female participants (aged 18-42) sp-ent three consecutive nights in the sleep lab ("Adaptation", "EMG", and "NOVA" nights). Each night participants were given 5, twenty-minute nap opportunities. On the EMG night, participants were allowed to fall asleep freely. On the NOV A night, participants wore the Nov Alert™ wrist device that administered a Psychomotor Vigilance Test (PVT) when it detected that muscle activity levels had dropped below baseline. Nap sessions were scored using Hori's 9-stage scoring system (Hori et aI, 1994). Power spectral analyses (FFT) were also performed. Effects ofthe PVT administration on EMG and EEG frequencies were also examined. Both chin and wrist EMG activity showed reliable and significant decline during the early stages ofHori staging (stages HO to H3 characterized by decreases in alpha activity). All frequency bands studied went through significant changes as the participants progressed through each ofHori's 9 SO stages. Delta, theta, and sigma activity increased later in the SO continuum while a clear alpha dominance shift was noted as alpha activity shifted from the posterior regions of the brain (during Hori stages HO to H3) to the anterior portions (during Hori stages H7 to H9). Administration of the PVT produced significant increases in EMG activity and was effective in reversing subjective drowsiness experienced during the later stages of sleep onset. Limitations of the alerting effects of the PVTs were evident following 60 to 75 minutes of use in that PVTs delivered afterwards were no longer able to significantly increase EMG levels. The present study provides a clearer picture of the changes in EMG and EEG during the sleep onset period while testing the efficacy of a commercially developed alerting device. EMG decreases were found to begin during Hori stage 0 when EEG was - dominated by alpha wave activity and were maximal as Hori stages 2 to 5 were traversed (coincident with alpha and beta activity). This signifies that EMG decrements and the loss of resting alpha activity are closely related. Since decreased alpha has long been associated with drowsiness and impending sleep, this investigation links drops in muscle tone with sleepiness more directly than in previous investigations. The EMG changes were reliably demonstrated across participants and the NovAlert™ detected the EMG decrements when Hori stage 3 was entered. The alerting vibrations produced by the NovAlert™ occurred early enough in the SO process to be of practical importance as a sleepiness monitoring and alerting device.