420 resultados para Shunt embolization
Resumo:
BACKGROUND; Hemoptysis can be an acute medical emergency, which can be localized angiographically and controlled by therapeutic intervention.
Resumo:
We assessed the diagnostic accuracy and time effectiveness of the Statscan low-dose full-body digital x-ray machine in the evaluation of ventriculoperitoneal (VP) shunt dysfunction.
Resumo:
An unintentional embolization of retinal arteries is rare and has been documented as a complication after embolization of arteries supplying head and neck tumors. However, occlusion of the central retinal artery with severe loss of vision has never been reported to be a complication from embolization of tumor-supplying ethmoidal branches of the ophthalmic artery. A 40 year-old male patient with a history of right nephrectomy for renal cell carcinoma underwent preoperative radiological embolization of an ethmoidal metastasis after having experienced a life-threatening sinus bleeding. Repeated probing of the ophthalmic artery with an endovascular microcatheter for particle embolization of the tumor-supplying arteries was performed under anticoagulation with heparin. Postoperatively, a standard ophthalmological examination including extended vascular evaluation by angiography was performed. After extended probing of the ophthalmic artery a marked reduction in its blood flow occurred. Despite post-interventional imaging showing persisting perfusion of the central retinal and ciliary arteries, the patient developed complete loss of vision on this side four days later. At this time fundoscopy and fluorescein angiography revealed a recanalized central artery occlusion, while indocyanin angiography showed infarctions of the choroid. Radiological intervention via the ophthalmic artery can result in complete loss of vision, even after limited and transient obstruction of the vessel.
Resumo:
We describe a new, useful embolization technique applied to occlude narrow vessel branches (≤1.5 mm (0.06″) in diameter) by deployment of one hydrocoil, through a microcatheter, in a way similar to the way in which one might navigate through the vascular lumen with a guidewire.
Resumo:
We evaluated the feasibility of a modified embolization technique of pulmonary arteriovenous malformations (PAVM) using venous sac embolization with detachable coils combined with the feeding artery embolization with the Amplatzer vascular plug (AVP).
Resumo:
Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection.
Resumo:
This report describes the use of transluminal coil embolization to treat pseudoaneurysm of deep femoral artery branch in two patients. The pseudoaneurysms had developed after coronary angiographv in one patient and after hip replacement in the other. Immediate control angiography after embolization procedures demonstrated complete closure of the pseudoaneurysms. During follow-up of 19 and 3 months, respectively, there was no recurrent bleeding. The aim of this case report is to show the advances in endovascular microcatheter technology, and embolic materials, that made percutaneous transluminal embolization of arterial pseudoaneurysms safe and efficient. In addition, it keeps the medical personnel aware of vascular injuries at the access site related to endovascular procedures as well as vascular complications of total hip arthroplasty. It calls their attention to the possibility of endovascular treatment as an alternative to surgery.
Resumo:
Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of substitution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiography diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.
Resumo:
A 4-month-old female Holstein Friesian calf was referred to the Veterinary Teaching Hospital, University of Berne, Switzerland for evaluation of ataxia, weakness, apathy and stunted growth. Clinical examination revealed generalized ataxia, propioceptive deficits, decreased menace response and sensibility. Postmortem examination did not reveal macroscopic changes of major organs. Histologically, the brain and the spinal cord lesions were characterized by polymicrocavitation, preferentially affecting the white matter fibers at the junction of grey and white matter and by the presence of Alzheimer type II cells. The liver revealed lesions consistent with a congenital portosystemic shunt, characterized by increased numbers of arteriolar profiles and hypoplasia to absence of portal veins. The pathological investigations along with the animal history and clinical signs indicated a hepatic encephalomyelopathy due to a congenital portosystemic shunt.
Resumo:
PURPOSE: To retrospectively determine the sensitivity of ovarian artery (OA) visualization at aortography performed after uterine fibroid embolization (UFE) and, using OA arteriography as the reference standard, compare the extent of arterial flow to the uterus at aortography with selective ovarian arteriography, to establish the utility of aortography and ovarian arteriography in the routine practice of UFE. MATERIALS AND METHODS: This study received institutional review board approval with waiver of informed consent and was HIPAA compliant. Retrospective review of 1129 consecutive UFE patients (1072 with aortograms, 57 excluded; mean age, 44 years; range, 21-60 years) was performed to identify all visible OAs. Visible OAs were independently graded by two interventional radiologists according to extent of pelvic arterial flow. If selective arteriography was performed, a second grade was assigned based on assessment of the selective study. Descriptive and summary statistics were used for assessment by the senior observer, and interobserver variability was determined. RESULTS: Of 1072 UFE patients, 184 (17.2%) had at least one visible OA. Ten (0.8%) patients were identified at aortography with collateral OA supply to more than 10% of the uterus. In total, 251 OAs were visualized, and 157 of these were further evaluated with selective study. Sixty-two (5.8%) patients were identified at selective arteriography as having collateral OA supply. The sensitivity of aortography was approximately 18%. Interobserver concordance was high (kappa values of 0.81 and 0.90 for aortography and selective study, respectively), but not perfect. CONCLUSION: Aortography rarely helps identify patients with substantial residual OA supply to the uterus and is a poor predictor of the extent of that supply, and thus may be of limited utility in routine UFE.
Resumo:
PURPOSE: To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS: Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS: IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS: The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.
Resumo:
We describe the successful selective coil embolization of an infected superior gluteal pseudoaneurysm secondary to methicillin-resistant Staphylococcus aureus (MRSA) in a 36-year old women. The patient presented with a long history of drug abuse and perisacral abscesses due to chronic sacroilitis. The chosen strategy provides a safe and successful management of infected false gluteal artery aneurysm.