789 resultados para Shoulder Girdle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We aimed to establish values and parameters using multislice reconstruction in axial computerized tomography (CT) in order to quantify the erosion of the glenoid cavity in cases of shoulder instability. Methods: We studied two groups using CT. Group I had normal subjects and Group II had patients with shoulder instability. We measured values of the vertical segment, the superior horizontal, medial and inferior segments, and also calculated the ratio of the horizontal superior and inferior segments of the glenoid cavity in both normal subjects and those with shoulder instability. These variables were recorded during arthroscopy for cases with shoulder instability. Results The mean values were 40.87 mm, 17.86 mm, 26.50 mm, 22.86 mm and 0.79 for vertical segment, the superior horizontal, medial and inferior segments, and the ratio between horizontal superior and inferior segments of the glenoid cavity respectively, in normal subjects. For subjects with unstable shoulders the mean values were 37.33 mm, 20.83 mm, 23.07 mm and 0.91 respectively. Arthroscopic measurements yielded an inferior segment value of 24.48 mm with a loss of 2.39 mm (17.57%). The ratio between the superior and inferior segments of the glenoid cavity was 0.79. This value can be used as a normative value for evaluating degree of erosion of the anterior border of the glenoid cavity. However, values found using CT should not be used on a comparative basis with values found during arthroscopy. Conclusions: Computerized tomographic measurements of the glenoid cavity yielded reliable values consistent with those in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last years the number of shoulder arthroplasties has been increasing. Simultaneously the study of their shape, size and strength and the reasons that bring to a possible early explantation have not yet been examined in detail. The research carried out directly on explants is practically nonexistent, this means a poor understanding of the mechanisms leading the patient and so the surgeon, to their removal. The analysis of the mechanisms which are the cause of instability, dislocation, broken, fracture, etc, may lead to a change in the structure or design of the shoulder prostheses and lengthen the life of the implant in situ. The idea was to analyze 22 explants through three methods in order to find roughness, corrosion and surface wear. In the first method, the humeral heads and/or the glenospheres were examined with the interferometer, a machine that through electromagnetic waves gives information about the roughness of the surfaces under examination. The output of the device was a total profile containing both roughness and information on the waves (representing the spatial waves most characteristic on the surface). The most important value is called "roughness average" and brings the average value of the peaks found in the local defects of the surfaces. It was found that 42% of the prostheses had considerable peak values in the area where the damage was caused by the implant and not only by external events, such as possibly the surgeon's hand. One of the problems of interest in the use of metallic biomaterials is their resistance to corrosion. The clinical significance of the degradation of metal implants has been the purpose of the second method; the interaction between human body and metal components is critical to understand how and why they arrive to corrosion. The percentage of damage in the joints of the prosthetic components has been calculated via high resolution photos and the software ImageJ. The 40% and 50% of the area appeared to have scratches or multiple lines due to mechanical artifacts. The third method of analysis has been made through the use of electron microscopy to quantify the wear surface in polyethylene components. Different joint movements correspond to different mechanisms of damage, which were imprinted in the parts of polyethylene examined. The most affected area was located mainly in the side edges. The results could help the manufacturers to modify the design of the prostheses and thus reduce the number of explants. It could also help surgeons in choosing the model of the prosthesis to be implanted in the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In patients with a rotator cuff-deficient shoulder, a combined loss of active elevation and external rotation (CLEER) can occur when both the infraspinatus and teres minor muscles are absent. A reverse shoulder arthroplasty (RSA) can restore active elevation in these patients but cannot restore active external rotation because there are no other external rotator cuff muscles. We hypothesized that a modified L'Episcopo procedure (latissimus dorsi [LD] and teres major [TM] transfer) with a simultaneous RSA would restore shoulder function and activities of daily living (ADLs).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shoulder complaints and functional impairment are common sequelae of neck dissection. This is often attributed to injury of the spinal accessory nerve by dissection or direct trauma. Nevertheless, shoulder morbidity may also occur in cases in which the spinal accessory nerve has been preserved. In this article, the physiology and pathophysiology of the shoulder are discussed, followed by a consideration of the impact of neck dissection on shoulder complaints, functional impairment, and quality of life. Finally, rehabilitation will be considered. © 2010 Wiley Periodicals, Inc. Head Neck, 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The etiology of shoulder pain in the overhead athlete is often difficult to determine. This study hypothesized that (1) instability can present in a purely painful form, without any apparent history of instability, but with anatomic lesions indicative of instability, termed unstable painful shoulder (UPS), and that (2) arthroscopic shoulder stabilization is effective.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[1] The evolution of the rift shoulder and the sedimentary sequence of the Morondava basin in western Madagascar was mainly influenced by a Permo-Triassic continental failed rift (Karroo rift), and the early Jurassic separation of Madagascar from Africa. Karroo deposits are restricted to a narrow corridor along the basement-basin contact and parts of this contact feature a steep escarpment. Here, apatite fission track (AFT) analysis of a series of both basement and sediment samples across the escarpment reveals the low-temperature evolution of the exhuming Precambrian basement in the rift basin shoulder and the associated thermal evolution of the sedimentary succession. Seven basement and four Karroo sediment samples yield apparent AFT ages between ∼330 and ∼215 Ma and ∼260 and ∼95 Ma, respectively. Partially annealed fission tracks and thermal modeling indicate post-depositional thermal overprinting of both basement and Karroo sediment. Rocks presently exposed in the rift shoulder indicate temperatures of >60°C associated with this reheating whereby the westernmost sample in the sedimentary plain experienced almost complete resetting of the detrital apatite grains at temperatures of about ∼90–100°C. The younging of AFT ages westward indicates activity of faults, re-activating inherited Precambrian structures during Karroo sedimentation. Furthermore, our data suggest onset of final cooling/exhumation linked to (1) the end of Madagascar's drift southward relative to Africa during the Early Cretaceous, (2) activity of the Marion hot spot and associated Late Cretaceous break-up between Madagascar and India, and (3) the collision of India with Eurasia and subsequent re-organization of spreading systems in the Indian Ocean.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent studies have suggested that tenotomy and repair of the subscapularis tendon carried out for anterior approaches to the shoulder can be followed by failure of the tendon repair and by changes resulting in permanent loss of subscapularis function. We hypothesized that release of the subscapularis with use of a superficial osteotomy of the lesser tuberosity followed by repair of the two opposing bone surfaces would lead to consistent bone-to-bone healing, which would be possible to monitor radiographically, and would lead to satisfactory clinical and structural outcomes. METHODS: Thirty-nine shoulders in thirty-six consecutive patients who, at an average age of fifty-seven years, had undergone total shoulder replacement through an anterior approach involving an osteotomy of the lesser tuberosity were evaluated at an average of thirty-nine months. Assessment included a standardized interview and physical examination, scoring according to the system described by Constant and Murley, and imaging with conventional radiography and computed tomography to assess healing of the osteotomy site and changes in the subscapularis. RESULTS: The osteotomized tuberosity fragment healed in an anatomical position in all shoulders, and no cuff tendon ruptures were observed. At the time of follow-up, thirty-three (89%) of thirty-seven shoulders evaluated with a belly-press test had a negative result and twenty-seven (75%) of thirty-six shoulders evaluated with a lift-off test had an unequivocally normal result. Fatty infiltration of the subscapularis muscle increased after the operation (p < 0.0001) and was at least stage two in eleven (32%) of thirty-four shoulders. The fatty infiltration had progressed by one stage in eight (24%) of the thirty-four shoulders, by two stages in five shoulders (15%), and by three stages in two shoulders (6%). CONCLUSIONS: Osteotomy of the lesser tuberosity provides an easy anterior approach for total shoulder replacement and is followed by consistent bone-to-bone healing, which can be monitored, and good subscapularis function. In the presence of documented anatomical healing of the osteotomy site, postoperative fatty infiltration of the subscapularis muscle remains unexplained and needs to be investigated further as it is associated with a poorer clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: (1) To analyse the imaging appearances of nine patients with acromioclavicular joint cysts presenting as shoulder masses for tumor staging with operative, histopathological and joint aspiration findings.DESIGN AND PATIENTS: Retrospective review of imaging and correlation with clinical, operative and surgical notes. Images were reviewed by two musculoskeletal radiologists by consensus. Nine patients who presented clinically with a shoulder mass were evaluated by radiographs (n=9), ultrasound (n=1), conventional arthrography (n=3), MRI (n=6; with direct MR arthrography n=2, indirect MR arthrography n=4).RESULTS: All patients had a focal mass superior to the AC joint, with a size ranging from 1.5 cm to 6 cm and a mean of 3.27 cm. Correlation was available with surgery (n=7), histopathology (n=2) and cyst aspiration (n=2). Two patients were managed conservatively. Geyser sign was positive in all three arthrograms. All MRIs revealed extensive rotator cuff tears with a column of fluid extending from the glenohumeral joint through the rotator cuff tear into the acromioclavicular joint and acromioclavicular cyst. Chondrocalcinosis was seen in the acromioclavicular joint cyst (n=2) and in the glenohumeral joint (n=1). Aspirate in two patients contained calcium pyrophosphate dihydrate crystals.CONCLUSION: Acromioclavicular joint cysts may present as a tumor mass. They are associated with extensive rotator cuff tears and there is usually communication of the cyst with the joint space. This feature excludes a diagnosis of tumor. AC joint cysts may be associated with calcium pyrophosphate dihydrate deposition disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the main types of MRI pseudotumors in and around the shoulder region. Some unusual types of pseudotumor will also be mentioned. Suggestions on how to improve awareness and diagnosis are also given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radical changes in prosthetic design made in the mid 1980s transformed the historically poorly performing reverse ball-and-socket total shoulder prosthesis into a highly successful salvage implant for pseudoparalytic, severely rotator cuff-deficient shoulders. Moving the center of rotation more medial and distal as well as implanting a large glenoid hemisphere that articulates with a humeral cup in 155 degrees of valgus are the biomechanical keys to sometimes spectacular short- to mid-term results. Use of the reverse total shoulder arthroplasty device allows salvage of injuries that previously were beyond surgical treatment. However, this technique has a complication rate approximately three times that of conventional arthroplasty. Radiographic and clinical results appear to deteriorate over time. Proper patient selection and attention to technical details are needed to reduce the currently high complication rate.