994 resultados para Shape Optimisation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with severe back deformities can greatly benefit from customized medical seating. Customized medical seating is made by taking measurements of each individual patient and making the seat as per these measurements. The current measuring systems employed by the industry are limited to use in clinics which are generally located only in major population centres. Patients living in remote areas are severely affected by this as the clinics could be far away and inaccessible for these patients. To provide service of customized medical seating requires a new measurement system which is portable so that the system could be transported to the patients in remote areas. The requirements for a new measurement system are analysed to suite the needs of Equipment Technology Services of the Cerebral Palsy League of Queensland. Design for a new measurement system was conceptualised by reviewing systems and technologies in various scientific disciplines. Design for a new system was finalised by optimizing each individual component. The final approach was validated by measuring difficult models and repeating the process to check for process variances. This system has now been adopted for clinical evaluation by ETS Suggestions have been made for further improvements in this new measurement approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semi-automatic segmentation of still images has vast and varied practical applications. Recently, an approach "GrabCut" has managed to successfully build upon earlier approaches based on colour and gradient information in order to address the problem of efficient extraction of a foreground object in a complex environment. In this paper, we extend the GrabCut algorithm further by applying an unsupervised algorithm for modelling the Gaussian Mixtures that are used to define the foreground and background in the segmentation algorithm. We show examples where the optimisation of the GrabCut framework leads to further improvements in performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This correspondence presents a microphone array shape calibration procedure for diffuse noise environments. The procedure estimates intermicrophone distances by fitting the measured noise coherence with its theoretical model and then estimates the array geometry using classical multidimensional scaling. The technique is validated on noise recordings from two office environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis investigates Theatre for Young People (TYP) as a site of performance innovation. The inquiry is focused on contemporary dramaturgy and its fieldwork aims to identify new dramaturgical principles operating in the creation and presentation of TYP. The research then seeks to assess how these new principles contribute to Postdramatic Theatre theory. This research inquiry springs from an imperative based in practice: Young people under 25 years have a literacy based on online hypertextual experiences which take the reader outside the frames of a dramatic narrative and beyond principles such as linearity, dramatic unity, teleology and resolution. As a dramaturg and educator I wanted to understand the new ways that young people engage in cultural products, to identify and utilize the new principles of dramaturgy that are now in evidence. My research examines how two playwright/directors approach their work and the new principles that can be identified in their dramaturgy. The fieldwork is scoped into two case studies: the first on TJ Eckleberg working in Australian Theatre for Young People and the second on Kristo Šagor working in German Children’s and Young People’s Theatre (KJT). These case studies address both types of production dramaturgy - the dramaturgy emergent through process in devised performance making, and that emergent in a performance based on a written playscript. On Case Study One the researcher, as participant observer, worked as production dramaturg on a large scale, site specific performance, observing the dramaturgy in process of its director and chief devisor. On Case Study Two the researcher, as observer and analyst, undertook a performance analysis of three playscripts and productions by a contemporary German playwright and director. Utilizing participant observation, reflective practice and grounded analysis the case studies have identified two new principles animating the dramaturgy of these TYP practitioners, namely ‘displacement’ and ‘installation.’ Taking practice into theory, the thesis concludes by demonstrating how displacement and installation contribute to Postdramatic Theatre’s “arsenal of expressive gestures which serve as theatre’s response to changed social communication under the conditions of generalized communication technologies” (Lehmann, H.-T., 2006, p.23). This research makes an original contribution to knowledge by evidencing that the principles of Postdramatic Theory lie within the practice of contemporary Theatre for Young People. It also contributes valuable research to a specialized, often overlooked terrain, namely Dramaturgy in Theatre for Young People, presented here with a contemporary, international and intercultural perspective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Severe spinal deformity in young children is a formidable challenge for optimal treatment. Standard interventions for adolescents, such as spinal deformity correction and fusion, may not be appropriate for young patients with considerable growth remaining. Alternative surgical options that provide deformity correction and protect the growth remaining in the spine are needed to treat this group of patients 1, 2. One such method is the use of shape memory alloy staples. We report our experience to date using video-assisted thoracoscopic insertion of shape memory alloy staples. A retrospective review was conducted of 13 patients with scoliosis, aged 7 to 13 years, who underwent video-assisted thoracoscopic insertion of shape memory staples. In our experience, video-assisted thoracoscopic insertion of shape memory alloy staples is a safe procedure with no complications noted. It is a reliable method of providing curve stability, however the follow up results to date indicate that the effectiveness of the procedure is greater in younger patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main aims in artificial intelligent system is to develop robust and efficient optimisation methods for Multi-Objective (MO) and Multidisciplinary Design (MDO) design problems. The paper investigates two different optimisation techniques for multi-objective design optimisation problems. The first optimisation method is a Non-Dominated Sorting Genetic Algorithm II (NSGA-II). The second method combines the concepts of Nash-equilibrium and Pareto optimality with Multi-Objective Evolutionary Algorithms (MOEAs) which is denoted as Hybrid-Game. Numerical results from the two approaches are compared in terms of the quality of model and computational expense. The benefit of using the distributed hybrid game methodology for multi-objective design problems is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shell structures find use in many fields of engineering, notably structural, mechanical, aerospace and nuclear-reactor disciplines. Axisymmetric shell structures are used as dome type of roofs, hyperbolic cooling towers, silos for storage of grain, oil and industrial chemicals and water tanks. Despite their thin walls, strength is derived due to the curvature. The generally high strength-to-weight ratio of the shell form, combined with its inherent stiffness, has formed the basis of this vast application. With the advent in computation technology, the finite element method and optimisation techniques, structural engineers have extremely versatile tools for the optimum design of such structures. Optimisation of shell structures can result not only in improved designs, but also in a large saving of material. The finite element method being a general numerical procedure that could be used to treat any shell problem to any desired degree of accuracy, requires several runs in order to obtain a complete picture of the effect of one parameter on the shell structure. This redesign I re-analysis cycle has been achieved via structural optimisation in the present research, and MSC/NASTRAN (a commercially available finite element code) has been used in this context for volume optimisation of axisymmetric shell structures under axisymmetric and non-axisymmetric loading conditions. The parametric study of different axisymmetric shell structures has revealed that the hyperbolic shape is the most economical solution of shells of revolution. To establish this, axisymmetric loading; self-weight and hydrostatic pressure, and non-axisymmetric loading; wind pressure and earthquake dynamic forces have been modelled on graphical pre and post processor (PATRAN) and analysis has been performed on two finite element codes (ABAQUS and NASTRAN), numerical model verification studies are performed, and optimum material volume required in the walls of cylindrical, conical, parabolic and hyperbolic forms of axisymmetric shell structures are evaluated and reviewed. Free vibration and transient earthquake analysis of hyperbolic shells have been performed once it was established that hyperbolic shape is the most economical under all possible loading conditions. Effect of important parameters of hyperbolic shell structures; shell wall thickness, height and curvature, have been evaluated and empirical relationships have been developed to estimate an approximate value of the lowest (first) natural frequency of vibration. The outcome of this thesis has been the generation of new research information on performance characteristics of axisymmetric shell structures that will facilitate improved designs of shells with better choice of shapes and enhanced levels of economy and performance. Key words; Axisymmetric shell structures, Finite element analysis, Volume Optimisation_ Free vibration_ Transient response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the influence of soft contact lenses on regional variations in corneal thickness and shape while taking account of natural diurnal variations in these corneal parameters. Methods: Twelve young, healthy subjects wore 4 different types of soft contact lenses on 4 different days. The lenses were of two different materials (silicone hydrogel, hydrogel), designs (spherical, toric) and powers (–3.00, –7.00 D). Corneal thickness and topography measurements were taken before and after 8 hours of lens wear and on two days without lens wear, using the Pentacam HR system. Results: The hydrogel toric contact lens caused the greatest level of corneal thickening in the central (20.3 ± 10.0 microns) as well as peripheral cornea (24.1 ± 9.1 microns) (p < 0.001) with an obvious regional swelling of the cornea beneath the stabilizing zones. The anterior corneal surface generally showed slight flattening. All contact lenses resulted in central posterior corneal steepening and this was weakly correlated with central corneal swelling (p = 0.03) and peripheral corneal swelling (p = 0.01). Conclusions: There was an obvious regional corneal swelling apparent after wear of the hydrogel soft toric lenses, due to the location of the thicker stabilization zones of the toric lenses. However with the exception of the hydrogel toric lens, the magnitude of corneal swelling induced by the contact lenses over the 8 hours of wear was less than the natural diurnal thinning of the cornea over this same period.