981 resultados para Separation (Technology)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nano(bio)science and nano(bio)technology play a growing and tremendous interest both on academic and industrial aspects. They are undergoing rapid developments on many fronts such as genomics, proteomics, system biology, and medical applications. However, the lack of characterization tools for nano(bio)systems is currently considered as a major limiting factor to the final establishment of nano(bio)technologies. Flow Field-Flow Fractionation (FlFFF) is a separation technique that is definitely emerging in the bioanalytical field, and the number of applications on nano(bio)analytes such as high molar-mass proteins and protein complexes, sub-cellular units, viruses, and functionalized nanoparticles is constantly increasing. This can be ascribed to the intrinsic advantages of FlFFF for the separation of nano(bio)analytes. FlFFF is ideally suited to separate particles over a broad size range (1 nm-1 μm) according to their hydrodynamic radius (rh). The fractionation is carried out in an empty channel by a flow stream of a mobile phase of any composition. For these reasons, fractionation is developed without surface interaction of the analyte with packing or gel media, and there is no stationary phase able to induce mechanical or shear stress on nanosized analytes, which are for these reasons kept in their native state. Characterization of nano(bio)analytes is made possible after fractionation by interfacing the FlFFF system with detection techniques for morphological, optical or mass characterization. For instance, FlFFF coupling with multi-angle light scattering (MALS) detection allows for absolute molecular weight and size determination, and mass spectrometry has made FlFFF enter the field of proteomics. Potentialities of FlFFF couplings with multi-detection systems are discussed in the first section of this dissertation. The second and the third sections are dedicated to new methods that have been developed for the analysis and characterization of different samples of interest in the fields of diagnostics, pharmaceutics, and nanomedicine. The second section focuses on biological samples such as protein complexes and protein aggregates. In particular it focuses on FlFFF methods developed to give new insights into: a) chemical composition and morphological features of blood serum lipoprotein classes, b) time-dependent aggregation pattern of the amyloid protein Aβ1-42, and c) aggregation state of antibody therapeutics in their formulation buffers. The third section is dedicated to the analysis and characterization of structured nanoparticles designed for nanomedicine applications. The discussed results indicate that FlFFF with on-line MALS and fluorescence detection (FD) may become the unparallel methodology for the analysis and characterization of new, structured, fluorescent nanomaterials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Noninvasive molecular-imaging technologies are playing a keyrole in drug discovery, development and delivery. Positron Emission Tomography (PET) is such a molecular imaging technology and a powerful tool for the observation of various diseases. However, it is limited by the availability of agents with high selectivity to the target and a physical half-life of the used positron emitting nuclide which matches the biological half-life of the observed process. For the long lasting enrichment of antibodies in tumor tissue few suitable isotopes for PET imaging are currently available. The element arsenic provides a range of isotopes, which could be used for diagnosis and also for endoradiotherapy. This work describes the development of radiochemical separation procedures to separate arsenic isotopes in no-carrier-added (nca) purity from reactor or cyclotron irradiated targets, the development and evaluation of a labeling chemistry to attach these separated arsenic isotopes to monoclonal antibodies, the in vitro and in vivo evaluation of antibodies labeled with radioactive arsenic isotopes and the molecular imaging using small animal PET.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel design based on electric field-free open microwell arrays for the automated continuous-flow sorting of single or small clusters of cells is presented. The main feature of the proposed device is the parallel analysis of cell-cell and cell-particle interactions in each microwell of the array. High throughput sample recovery with a fast and separate transfer from the microsites to standard microtiter plates is also possible thanks to the flexible printed circuit board technology which permits to produce cost effective large area arrays featuring geometries compatible with laboratory equipment. The particle isolation is performed via negative dielectrophoretic forces which convey the particles’ into the microwells. Particles such as cells and beads flow in electrically active microchannels on whose substrate the electrodes are patterned. The introduction of particles within the microwells is automatically performed by generating the required feedback signal by a microscope-based optical counting and detection routine. In order to isolate a controlled number of particles we created two particular configurations of the electric field within the structure. The first one permits their isolation whereas the second one creates a net force which repels the particles from the microwell entrance. To increase the parallelism at which the cell-isolation function is implemented, a new technique based on coplanar electrodes to detect particle presence was implemented. A lock-in amplifying scheme was used to monitor the impedance of the channel perturbed by flowing particles in high-conductivity suspension mediums. The impedance measurement module was also combined with the dielectrophoretic focusing stage situated upstream of the measurement stage, to limit the measured signal amplitude dispersion due to the particles position variation within the microchannel. In conclusion, the designed system complies with the initial specifications making it suitable for cellomics and biotechnology applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays microfluidic is becoming an important technology in many chemical and biological processes and analysis applications. The potential to replace large-scale conventional laboratory instrumentation with miniaturized and self-contained systems, (called lab-on-a-chip (LOC) or point-of-care-testing (POCT)), offers a variety of advantages such as low reagent consumption, faster analysis speeds, and the capability of operating in a massively parallel scale in order to achieve high-throughput. Micro-electro-mechanical-systems (MEMS) technologies enable both the fabrication of miniaturized system and the possibility of developing compact and portable systems. The work described in this dissertation is towards the development of micromachined separation devices for both high-speed gas chromatography (HSGC) and gravitational field-flow fractionation (GrFFF) using MEMS technologies. Concerning the HSGC, a complete platform of three MEMS-based GC core components (injector, separation column and detector) is designed, fabricated and characterized. The microinjector consists of a set of pneumatically driven microvalves, based on a polymeric actuating membrane. Experimental results demonstrate that the microinjector is able to guarantee low dead volumes, fast actuation time, a wide operating temperature range and high chemical inertness. The microcolumn consists of an all-silicon microcolumn having a nearly circular cross-section channel. The extensive characterization has produced separation performances very close to the theoretical ideal expectations. A thermal conductivity detector (TCD) is chosen as most proper detector to be miniaturized since the volume reduction of the detector chamber results in increased mass and reduced dead volumes. The microTDC shows a good sensitivity and a very wide dynamic range. Finally a feasibility study for miniaturizing a channel suited for GrFFF is performed. The proposed GrFFF microchannel is at early stage of development, but represents a first step for the realization of a highly portable and potentially low-cost POCT device for biomedical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymeric membranes represent a promising technology for gas separation processes, thanks to low costs, reduced energy consumption and limited waste production. The present thesis aims at studying the transport properties of two membrane materials, suitable for CO2 purification applications. In the first part, a polyimide, Matrimid 5218, has been throughout investigated, with particular reference to the effect of thermal treatment, aging and the presence of water vapor in the gas transport process. Permeability measurements showed that thermal history affects relevantly the diffusion of gas molecules across the membrane, influencing also the stability of the separation performances. Subsequently, the effect of water on Matrimid transport properties has been characterized for a wide set of incondensable penetrants. A monotonous reduction of permeability took place at increasing the water concentration within the polymer matrix, affecting the investigated gaseous species to the same extent, despite the different thermodynamic and kinetic features. In this view, a novel empirical model, based on the Free Volume Theory, has been proposed to qualitatively describe the phenomenon. Moreover, according to the accurate representation of the experimental data, the suggested approach has been combined with a more rigorous thermodynamic tool (NELF Model), allowing an exhaustive description of water influence on the single parameters contributing to the gas permeation across the membrane. In the second part, the study has focused on the synthesis and characterization of facilitated transport membranes, able to achieving outstanding separation performances thanks to the chemical enhancement of CO2 permeability. In particular, the transport properties have been investigated for high pressure CO2 separation applications and specific solutions have been proposed to solve stability issues, frequently arising under such severe conditions. Finally, the effect of different process parameters have been investigated, aiming at the identification of the optimal conditions capable to maximize the separation performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In dieser Dissertation wird die Ladungsträgergeneration und -rekombination in neuen polymeren Absorbermaterialien für organische Solarzellen untersucht. Das Verständnis dieser Prozesse ist wesentlich für die Entwicklung neuer photoaktiver Materialsysteme, die hohe Effizienzen erzielen und organische Solarzellen konkurrenzfähig im Bereich der erneuerbaren Energien machen. Experimentell verwendet diese Arbeit hauptsächlich die Methode der transienten Absorptionsspektroskopie, die sich für die Untersuchung photophysikalischer Prozesse auf einer Zeitskala von 100 fs bis 1 ms als sehr leistungsfähig erweist. Des Weiteren wird eine soft-modeling Methode vorgestellt, die es ermöglicht, photophysikalische Prozesse aus einer gemessenen transienten Absorptions-Datenmatrix zu bestimmen, wenn wenig a priori Kenntnisse der Reaktionskinetiken vorhanden sind. Drei unterschiedliche Donor:Akzeptor-Systeme werden untersucht; jedes dieser Systeme stellt eine andere Herangehensweise zur Optimierung der Materialien dar in Bezug auf Lichtabsorption über einen breiten Wellenlängenbereich, effiziente Ladungstrennung und schnellen Ladungstransport. Zuerst wird ein Terpolymer untersucht, das aus unterschiedlichen Einheiten für die Lichtabsorption und den Ladungstransport besteht. Es wird gezeigt, dass es möglich ist, den Fluss angeregter Zustände vom Chromophor auf die Transporteinheit zu leiten. Im zweiten Teil wird der Einfluss von Kristallinität auf die freie Ladungsträgergeneration mit einer Folge von ternären Mischungen, die unterschiedliche Anteile an amorphem und semi-kristallinem Polymer enthalten, untersucht. Dabei zeigt es sich, dass mit steigendem amorphen Polymeranteil sowohl der Anteil der geminalen Ladungsträgerrekombination erhöht als auch die nicht-geminale Rekombination schneller ist. Schlussendlich wird ein System untersucht, in dem sowohl Donor als auch Akzeptor Polymere sind, was zu verbesserten Absorptionseigenschaften führt. Die Rekombination von Ladungstransferzuständen auf der unter 100 ps Zeitskala stellt hier den hauptsächliche Verlustkanal dar, da freie Ladungsträger nur an Grenzflächen erzeugt werden können, an denen Donor und Akzeptor face-to-face zueinander orientiert sind. Darüber hinaus wird festgestellt, dass weitere 40-50% der Ladungsträger durch die Rekombination von Grenzflächenzuständen verloren gehen, die aus mobilen Ladungsträgern geminal gebildet werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was the final stage of a four-year study of managerial behaviour and company performance in Bulgaria and examined the influence of changing ownership and control structures of companies on managerial behaviour and initiative. It provides a theoretical summary of the specific types of ownership, control, governance structures and managerial strategies in the Bulgarian transitional economy during 1992-1996. It combines two theoretical approaches, the property-rights approach to show concentrated property-rights structure and private and majority types of control as determinants of efficient enterprise risk bearing and constrained managerial discretion, and the agency theory approach to reveal the efficient role of direct non-market governance mechanisms over managers. Mr. Peev also used empirical information collected from the Central Statistical office in Bulgaria, three different enterprise investigations of corporatised state-owned enterprises between 1992 and 1994, and his own data base of privatised and private de novo industrial companies in 1996-1996. The project gives a detailed description of the main property-rights structures in Bulgaria at the present time and of the various control structures related to these. It found that there is a strong owner type of control in private and privatised firms, although, contrary to expectations, 100% state -owned enterprises tended to be characterised by a separation of ownership from control, leaving scope for managerial discretion. Mr. Peev predicts that after the forthcoming mass privatisation, many companies will acquire a dispersed ownership structure and there will be a greater separation of ownership from control and potential or inefficient managerial behaviour. The next aspect considered in detail was governance structures and the influence of the generally unstable macroeconomic environment in the country during the period in question. In examining managerial strategies, Mr. Peev divided the years since 1990 into 3 periods. Even in the first period (1990-1992) there were some signs of a more efficient role for managers and between 1992 and 1994 the picture of control structures and different managerial behaviour in state-owned companies became more diversified. Managerial strategies identified included managerial initiatives for privatisation, where managers took initiative in resolving problems of property rights and introducing restructuring measures and privatisation proposals, managerial initiatives for restructuring without privatisation, and passive adjustment and passive management, where managers seek outside services for marketing, finance management, etc. in order to adjust to the new environment. During 1995-1996 some similarities and differences between the managerial behaviour of privatised and state-owned firms emerged. Firstly, the former have undergone many changes in investment and technology, while managers of state-owned companies have changed little in this field, indicating that the private property-rights structure is more efficient for the long-term adaptation of enterprises. In the area of strategies relating to product quality, marketing, and pricing policy there was little difference between managers of private, privatised and state-owned firms. The most passive managerial behaviour was found in non-incorporated state-owned firms, although these have only an insignificant stake in the economy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the current market system, power systems are operated at higher loads for economic reasons. Power system stability becomes a genuine concern in such operating conditions. In case of failure of any larger component, the system may become stressed. These events may start cascading failures, which may lead to blackouts. One of the main reasons of the major recorded blackout events has been the unavailability of system-wide information. Synchrophasor technology has the capability to provide system-wide real time information. Phasor Measurement Units (PMUs) are the basic building block of this technology, which provide the Global Positioning System (GPS) time-stamped voltage and current phasor values along with the frequency. It is being assumed that synchrophasor data of all the buses is available and thus the whole system is fully observable. This information can be used to initiate islanding or system separation to avoid blackouts. A system separation strategy using synchrophasor data has been developed to answer the three main aspects of system separation: (1) When to separate: One class support machines (OC-SVM) is primarily used for the anomaly detection. Here OC-SVM was used to detect wide area instability. OC-SVM has been tested on different stable and unstable cases and it is found that OC-SVM has the capability to detect the wide area instability and thus is capable to answer the question of “when the system should be separated”. (2) Where to separate: The agglomerative clustering technique was used to find the groups of coherent buses. The lines connecting different groups of coherent buses form the separation surface. The rate of change of the bus voltage phase angles has been used as the input to this technique. This technique has the potential to exactly identify the lines to be tripped for the system separation. (3) What to do after separation: Load shedding was performed approximately equal to the sum of power flows along the candidate system separation lines should be initiated before tripping these lines. Therefore it is recommended that load shedding should be initiated before tripping the lines for system separation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dielectrophoresis—the tendency of a material of high dielectric permittivity to migrate in an electrical field gradient to a region of maximum field strength—provides an ideal motive force for manipulating small volumes of biological analytes in microfluidic microsystems. The work described in this thesis was based on the hypothesis that dielectrophoresis could be exploited to provide high-resolution cell separations in microsystems as well as a means for the electrically-controllable manipulation of solid supports for molecular analysis. To this end, a dielectrophoretic/gravitational field-flow-fractionation (DEP/G-FFF) system was developed and the separation performance evaluated using various types and sizes of polystyrene microspheres as model particles. It was shown that separation of the polystyrene beads was based on the differences in their effective dielectrophoretic properties. The ability of an improved DEP/G-FFF system to separate genetically identical, but phenotypically dissimilar cell types was demonstrated using mixtures of 6m2 mutant rat kidney cells grown under transforming and non-transforming culture conditions. Additionally, a panel of engineered dielectric microspheres was designed with specific, predetermined dielectrophoretic properties such that their dielectrophoretic behaviors would be controllable and predictable. The fabrication method involved the use of gold-coated polystyrene microsphere cores coated with a self-assembled monolayer of alkanethiol and, optionally, a self-assembled monolayer of phospholipid to form a thin-insulating-shell-over-conductive-interior structure. The successful development of the DEP/G-FFF separation system and the dielectrically engineered microspheres provides proof-of-principle demonstrations of enabling dielectrophoresis-based microsystem technology that should provide powerful new methods for the manipulation, separation and identification of analytes in many diverse fields. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"Interim report for period January 1976-February 1976."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this work is to establish the application of a fully automated microfluidic chip based protein separation assay in tear analysis. It is rapid, requires small sample volumes and is vastly superior to, and more convenient than, comparable conventional gel electrophoresis assays. The protein sizing chip technology was applied to three specific fields of analysis. Firstly tear samples were collected regularly from subjects establishing the baseline effects of tear stimulation, tear state and patient health. Secondly tear samples were taken from lens wearing eyes and thirdly the use of microfluidic technology was assessed as a means to investigate a novel area of tear analysis, which we have termed the 'tear envelope'. Utilising the Agilent 2100 Bioanalyzer in combination with the Protein 200 Plus LabChip kit, these studies investigated tear proteins in the range of 14-200 kDa. Particular attention was paid to the relative concentrations of lysozyme, tear lipocalin, secretory IgA (sIgA), IgG and lactoferrin, together with the overall tear electropherogram 'fingerprint'. Furthermore, whilst lens-tear interaction studies are generally thought of as an investigation into the effects of tears components on the contact lens material, i.e. deposition studies, this report addresses the reverse phenomenon-the effect of the lens, and particularly the newly inserted lens, on the tear fluid composition and dynamics. The use of microfluidic technology provides a significant advance in tear studies and should prove invaluable in tear diagnostics and contact lens performance analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the clinical/microbiological laboratory there are currently several ways of separating specific cells from a fluid suspension. Conventionally cells can be separated based on size, density, electrical charge, light-scattering properties, and antigenic surface properties. Separating cells using these parameters can require complex technologies and specialist equipment. This paper proposes new Bio-MEMS (microelectromechanical systems) filtration chips manufactured using deep reactive ion etching (DRIE) technology that, when used in conjunction with an optical microscope and a syringe, can filter and grade cells for size without the requirement for additional expensive equipment. These chips also offer great versatility in terms of design and their low cost allows them to be disposable, eliminating sample contamination. The pumping mechanism, unlike many other current filtration techniques, leaves samples mechanically and chemically undamaged. In this paper the principles behind harnessing passive pumping are explored, modelled, and validated against empirical data, and their integration into a microfluidic device to separate cells from a mixed population suspension is described. The design, means of manufacture, and results from preliminary tests are also presented. © IMechE 2007.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the horizontal deflection behaviour of the streams of particles in paramagnetic fluids under a high-gradient superconducting magnetic field, which is the continued work on the exploration of particle magneto-Archimedes levitation. Based on the previous work on the horizontal deflection of a single particle, a glass box and collector had been designed to observe the movement of particle group in paramagnetic fluids. To get the exact separation efficiency, the method of "sink-float" involved the high density fluid polytungstate (dense medium separation) and MLA (Mineral Liberation Analyser) was performed. It was found that the particles were deflected and settled at certain positions on the container floor due to the combined forces of gravity and magneto-Archimedes forces as well as a lateral buoyancy (displacement) force. Mineral particles with different densities and susceptibilities could be deflected to different positions, thus producing groups of similar types of particles. The work described here, although in its infancy, could form the basis of new approach of separating particles based on a combination of susceptibility and density. © 2014 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Funded by European Research Council ERC. Grant Number: project GA 335910 VEWA