71 resultados para Semiotécnica oftálmica
Resumo:
Objective: To evaluate the differences between goblet cell density (GCD) and symptomatology after one month of orthokeratology lens wear. Methods: A pilot, short-term study was conducted. Twenty-two subjects (29.7. ±. 7.0 years old) participated voluntarily in the study. Subjects were divided into two groups: habitual silicone hydrogel contact lens wearers (SiHCLW) and new contact lens wearers (NCLW). Schirmer test, tear break up time (TBUT), Ocular Surface Disease Index (OSDI) questionnaire and conjunctival impression cytology. GCD, mucin cloud height (MCH) and cell layer thickness (CLT) were measured. All measurements were performed before orthokeratology fitting and one month after fitting to assess the evolution of the changes throughout this time. Results: No differences in tear volume and TBUT between groups were found (p>0.05). However, the OSDI score was statistically better after one month of orthokeratology lens wear than the baseline for the SiHCLW group (p=0.03). Regarding the goblet cell analysis, no differences were found in CLT and MCH from the baseline visit to the one month visit for the SiHCLW compared with NCLW groups (p>0.05). At baseline, the GCD in the SiHCLW group were statistically lower than NCLW group (p<0.001). There was a significant increase in GCD after orthokeratology fitting from 121±140cell/mm2 to 254±130cell/mm2 (p<0.001) in the SiHCLW group. Conclusion: Orthokeratology improves the dry eye subject symptoms and GCD after one month of wearing in SiHCLW. These results suggest that orthokeratology could be considered a good alternative for silicone hydrogel contact lens discomfort and dryness. © 2016 British Contact Lens Association.
Resumo:
Purpose.: To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap4A) and diadenosine pentaphosphate (Ap5A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment. Methods.: Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap4A and Ap5A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated. Results.: Ap4A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period. Conclusions.: Daily wear of RGP lenses increased the levels of Ap4A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.
Resumo:
Objetivo/Método: Valorar la sensibilidad al contraste fotópica, sin y con deslumbramiento con un nuevo instrumento. Se estudiaron 78 ojos derechos de 49 adultos jóvenes y de 29 adultos entre 35 y 55 años. La sensibilidad al contraste se midió con el Contrast Glaretester CGT-1000 mediante una estrategia automatizada de reconocimiento para seis frecuencias espaciales. Resultados/Conclusiones: Los valores de sensibilidad al contraste fueron semejantes a los obtenidos con otros tests clínicos. El aumento de la edad disminuyó significativamente la sensibilidad al contraste sin y con deslumbramiento. Sin embargo, el deslumbramiento no modificó la sensibilidad al contraste fotópica.
Resumo:
Dissertação de mestrado, Ciências Farmacêuticas, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2012
Resumo:
In the study of the spatial characteristics of the visual channels, the power spectrum model of visual masking is one of the most widely used. When the task is to detect a signal masked by visual noise, this classical model assumes that the signal and the noise are previously processed by a bank of linear channels and that the power of the signal at threshold is proportional to the power of the noise passing through the visual channel that mediates detection. The model also assumes that this visual channel will have the highest ratio of signal power to noise power at its output. According to this, there are masking conditions where the highest signal-to-noise ratio (SNR) occurs in a channel centered in a spatial frequency different from the spatial frequency of the signal (off-frequency looking). Under these conditions the channel mediating detection could vary with the type of noise used in the masking experiment and this could affect the estimation of the shape and the bandwidth of the visual channels. It is generally believed that notched noise, white noise and double bandpass noise prevent off-frequency looking, and high-pass, low-pass and bandpass noises can promote it independently of the channel's shape. In this study, by means of a procedure that finds the channel that maximizes the SNR at its output, we performed numerical simulations using the power spectrum model to study the characteristics of masking caused by six types of one-dimensional noise (white, high-pass, low-pass, bandpass, notched, and double bandpass) for two types of channel's shape (symmetric and asymmetric). Our simulations confirm that (1) high-pass, low-pass, and bandpass noises do not prevent the off-frequency looking, (2) white noise satisfactorily prevents the off-frequency looking independently of the shape and bandwidth of the visual channel, and interestingly we proved for the first time that (3) notched and double bandpass noises prevent off-frequency looking only when the noise cutoffs around the spatial frequency of the signal match the shape of the visual channel (symmetric or asymmetric) involved in the detection. In order to test the explanatory power of the model with empirical data, we performed six visual masking experiments. We show that this model, with only two free parameters, fits the empirical masking data with high precision. Finally, we provide equations of the power spectrum model for six masking noises used in the simulations and in the experiments.
Resumo:
PURPOSE To investigate the cortical mechanisms that prevent diplopia in intermittent exotropia (X(T)) during binocular alignment (orthotropia). METHODS The authors studied 12 X(T) patients aged 5 to 22 years. Seventy-five percent had functional stereo vision with stereoacuity similar to that of 12 age-matched controls (0.2-3.7 min arc). Identical face images were presented to the two eyes for 400 ms. In one eye, the face was presented at the fovea; in the other, offset along the horizontal axis with up to 12° eccentricity. The task was to indicate whether one or two faces were perceived. RESULTS All X(T) patients showed normal diplopia when the nonfoveal face was presented to nasal hemiretina, though with a slightly larger fusional range than age-matched controls. However, 10 of 12 patients never experienced diplopia when the nonfoveal face was presented to temporal hemiretina (i.e., when the stimulus simulated exodeviation). Patients showed considerable variability when the single image was perceived. Some patients suppressed the temporal stimulus regardless of which eye viewed it, whereas others suppressed a particular eye even when it viewed the foveal stimulus. In two patients, the simulated exodeviation might have triggered a shift from normal to anomalous retinal correspondence. CONCLUSIONS Antidiplopic mechanisms in X(T) can be reliably triggered by purely retinal information during orthotropia, but the nature of these mechanisms varies between patients.
Resumo:
In a previous contribution [Appl. Opt. 51, 8599 (2012)], a coauthor of this work presented a method for reconstructing the wavefront aberration from tangential refractive power data measured using dynamic skiascopy. Here we propose a new regularized least squares method where the wavefront is reconstructed not only using tangential but also sagittal curvature data. We prove that our new method provides improved quality reconstruction for typical and also for highly aberrated wavefronts, under a wide range of experimental error levels. Our method may be applied to any type of wavefront sensor (not only dynamic skiascopy) able to measure either just tangential or tangential plus sagittal curvature data.
Resumo:
Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.
Resumo:
We propose in this work a model for describing visual acuity (VV) as a function of defocus and pupil diameter. Although the model is mainly based on geometrical optics, it also incorporates nongeometrical effects phenomenologically. Compared to similar visual acuity models, the proposed one considers the effect of astigmatism and the variability of best corrected VV among individuals; it also takes into account the accommodation and the “tolerance to defocus,” the latter through a phenomenological parameter. We have fitted the model to the VV data provided in the works of Holladay et al. and Peters, showing the ability of this model to accurately describe the variation of VV against blur and pupil diameter. We have also performed a comparison between the proposed model and others previously published in the literature. The model is mainly intended for use in the design of ophthalmic compensations, but it can also be useful in other fields such as visual ergonomics, design of visual tests, and optical instrumentation.
Resumo:
Introdução: Serious games podem viabilizar ambiente simulado virtual transformando a experiência de jogo em aprendizagem significativa (Marsh, 2011). Os recursos multimídias são também interessantes para uso no ensino, enriquecendo, por meio da tecnologia, conteúdo cientificamente estruturado (Fonseca et al., 2013). Outra estratégia bastante utilizada na área da saúde, na qual também temos interesse, é a simulação, que oferece vantagens como segurança do paciente, ética na assistência e oportunidades de aprendizagem clínica (Martins et al., 2012). Objectivos: Avaliar a aprendizagem cognitiva de estudantes de enfermagem sobre avaliação clínica neonatal em um curso semipresencial utilizando simulação virtual e em laboratório; comparar a aprendizagem cognitiva dos estudantes assumindo como intervenção do grupo experimental a simulação em laboratório; e avaliar o curso na perspectiva dos estudantes. Metodologia: Foi conduzido estudo quase-experimental junto a 14 estudantes portugueses incluindo pré-teste, teste intermediário e pós-teste. As tecnologias incluídas no curso oferecido foram serious game e-Baby (jogo educacional com formato de simulação virtual), software instrucional de semiologia e semiotécnica (recursos multimídia e conteúdo embasado cientificamente) e simulação em laboratório, todos no tema avaliação clínica do bebê prematuro. Para a avaliação do curso e caracterização dos estudantes foram utilizados instrumentos de coleta de dados desenvolvidos especificamente para este estudo, e análise descritiva. A análise estatística foi não paramétrica: Mann-Whitney e Wilcoxon. Resultados: O uso de tecnologias digitais e de simulação em laboratório, evidenciou diferença estatisticamente significativa (p=0,001) na aprendizagem dos participantes. O curso foi avaliado como muito satisfatório pelos estudantes, que afirmaram, unanimemente, ter sido esta a primeira vez em que participaram de um curso envolvendo tecnologias educacionais digitais, apesar de já terem participado de outras simulações em laboratório. A simulação em laboratório isoladamente não representou diferença significativa no aprendizado (p=0,845), quando comparado grupo experimental em relação ao controle. Os resultados de avaliação do curso foram majoritariamente positivos variando essencialmente entre "muito bom" e "excelente" em todos os critérios. Sobre avaliação negativa, caracterizada pela opção "insuficiente", verificou-se no quesito: "Tempo reservado às práticas de simulação em laboratório" (n=3/21,5%). Tanto para a simulação em laboratório como a virtual, alguns estudantes sugeriram que fossem inseridos mais casos para estudo, de forma a oferecer mais material de natureza semelhante, reforçando a satisfação em utilizá-los como apoio para o curso oferecido. Conclusões: A aprendizagem cognitiva dos participantes aumentou significativamente ao se comparar os escores no fim do curso em relação ao início. A simulação em laboratório, analisada isoladamente, não representou mudança significativa nas pontuações quando se comparou grupo controle e experimental, o que destaca a importância da associação de ferramentas e estratégias no ensino superior em enfermagem. Considera-se que o uso de tecnologia seja parte do sucesso do mesmo, podendo ser uma importante ferramenta de inovação didática e motivação da aprendizagem na área da saúde. A avaliação dos estudantes sobre o curso reforça o interesse em ferramentas diferenciadas para apoio dos estudos.
Resumo:
Introdução: Serious games podem viabilizar ambiente simulado virtual transformando a experiência de jogo em aprendizagem significativa (Marsh, 2011). Os recursos multimídias são também interessantes para uso no ensino, enriquecendo, por meio da tecnologia, conteúdo cientificamente estruturado (Fonseca et al., 2013). Outra estratégia bastante utilizada na área da saúde, na qual também temos interesse, é a simulação, que oferece vantagens como segurança do paciente, ética na assistência e oportunidades de aprendizagem clínica (Martins et al., 2012). Objectivos: Avaliar a aprendizagem cognitiva de estudantes de enfermagem sobre avaliação clínica neonatal em um curso semipresencial utilizando simulação virtual e em laboratório; comparar a aprendizagem cognitiva dos estudantes assumindo como intervenção do grupo experimental a simulação em laboratório; e avaliar o curso na perspectiva dos estudantes. Metodologia: Foi conduzido estudo quase-experimental junto a 14 estudantes portugueses incluindo pré-teste, teste intermediário e pós-teste. As tecnologias incluídas no curso oferecido foram serious game e-Baby (jogo educacional com formato de simulação virtual), software instrucional de semiologia e semiotécnica (recursos multimídia e conteúdo embasado cientificamente) e simulação em laboratório, todos no tema avaliação clínica do bebê prematuro. Para a avaliação do curso e caracterização dos estudantes foram utilizados instrumentos de coleta de dados desenvolvidos especificamente para este estudo, e análise descritiva. A análise estatística foi não paramétrica: Mann-Whitney e Wilcoxon. Resultados: O uso de tecnologias digitais e de simulação em laboratório, evidenciou diferença estatisticamente significativa (p=0,001) na aprendizagem dos participantes. O curso foi avaliado como muito satisfatório pelos estudantes, que afirmaram, unanimemente, ter sido esta a primeira vez em que participaram de um curso envolvendo tecnologias educacionais digitais, apesar de já terem participado de outras simulações em laboratório. A simulação em laboratório isoladamente não representou diferença significativa no aprendizado (p=0,845), quando comparado grupo experimental em relação ao controle. Os resultados de avaliação do curso foram majoritariamente positivos variando essencialmente entre "muito bom" e "excelente" em todos os critérios. Sobre avaliação negativa, caracterizada pela opção "insuficiente", verificou-se no quesito: "Tempo reservado às práticas de simulação em laboratório" (n=3/21,5%). Tanto para a simulação em laboratório como a virtual, alguns estudantes sugeriram que fossem inseridos mais casos para estudo, de forma a oferecer mais material de natureza semelhante, reforçando a satisfação em utilizá-los como apoio para o curso oferecido. Conclusões: A aprendizagem cognitiva dos participantes aumentou significativamente ao se comparar os escores no fim do curso em relação ao início. A simulação em laboratório, analisada isoladamente, não representou mudança significativa nas pontuações quando se comparou grupo controle e experimental, o que destaca a importância da associação de ferramentas e estratégias no ensino superior em enfermagem. Considera-se que o uso de tecnologia seja parte do sucesso do mesmo, podendo ser uma importante ferramenta de inovação didática e motivação da aprendizagem na área da saúde. A avaliação dos estudantes sobre o curso reforça o interesse em ferramentas diferenciadas para apoio dos estudos.