965 resultados para Segment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new approach to speech enhancement from single-channel measurements involving both noise and channel distortion (i.e., convolutional noise), and demonstrates its applications for robust speech recognition and for improving noisy speech quality. The approach is based on finding longest matching segments (LMS) from a corpus of clean, wideband speech. The approach adds three novel developments to our previous LMS research. First, we address the problem of channel distortion as well as additive noise. Second, we present an improved method for modeling noise for speech estimation. Third, we present an iterative algorithm which updates the noise and channel estimates of the corpus data model. In experiments using speech recognition as a test with the Aurora 4 database, the use of our enhancement approach as a preprocessor for feature extraction significantly improved the performance of a baseline recognition system. In another comparison against conventional enhancement algorithms, both the PESQ and the segmental SNR ratings of the LMS algorithm were superior to the other methods for noisy speech enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV). DESIGN: Observational case series. METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS: 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS: There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS: Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the agreement between optical low-coherence reflectometry (OLCR) and anterior segment optical coherence tomography (AS-OCT) for biometry of the anterior segment. SETTING: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Evaluation of diagnostic technology. METHODS: A series of OLCR (Lenstar LS 900) and AS-OCT measurements of the anterior segment were taken for consecutive subjects aged 35 years and older in a population-based study. The differences and correlations between the 2 methods of ocular biometry were assessed. Agreement was calculated as the 95% limits of agreement (LoA). RESULTS: The mean age of the 776 subjects was 55.2 years ± 12.0 (SD); 54.6% were women. The mean central corneal thickness (CCT) was smaller with OLCR than with AS-OCT (537.84 ± 31.46 μm versus 559.39 ± 32.02 μm) as was anterior chamber depth (ACD) (2.60 ± 0.37 mm versus 2.72 ± 0.37 mm) and anterior chamber width (ACW) (11.76 ± 0.47 mm versus 12.04 ± 0.55 mm) (all P<.001). The 95% LoA between the 2 instruments were -44.80 to 1.71 μm for CCT, -0.17 to -0.06 mm for ACD, and -1.28 to 0.72 mm for ACW. CONCLUSION: Optical low-coherence reflectometry and AS-OCT yielded potentially interchangeable ACD measurements, while the CCT and ACW measurements acquired by the 2 devices showed clinically significant differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report discusses an unusual presentation of ST-segment elevation myocardial infarction (STEMI) with normal coronary arteries and severe mechanical complications successfully treated with surgery. An 82-year-old man presented STEMI with angiographically normal coronary arteries and no major echocardiographic alterations at discharge. At the first month follow-up, he complained of fatigue and dyspnea, and contrast echocardiography complemented by cardiac magnetic resonance imaging revealed a large left ventricular apical aneurysm with a thrombus communicating by two jets of a turbulent flow to an aneurysmatic formation of the right ventricular apex. The patient underwent a Dor procedure, which was successful. Ventricular septal defects and ventricular aneurysms are rare but devastating complications of STEMI, with almost all patients presenting multivessel coronary artery disease. Interestingly in this case, the angiographic pattern was normal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field lab: Business project

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. Clinicians commonly assess posture in persons with musculoskeletal disorders and tend to do so subjectively. Evidence-based practice requires the use of valid, reliable and sensitive tools to monitor treatment effectiveness. The purpose of this article was to determine which methods were used to assess posture quantitatively in a clinical setting and to identify psychometric properties of posture indices measured from these methods or tools. Methods. We conducted a comprehensive literature review. Pertinent databases were used to search for articles on quantitative clinical assessment of posture. Searching keywords were related to posture and assessment, scoliosis, back pain, reliability, validity and different body segments. Results. We identified 65 articles with angle and distance posture indices that corresponded to our search criteria. Several studies showed good intra- and inter-rater reliability for measurements taken directly on the persons (e.g., goniometer, inclinometer, flexible curve and tape measurement) or from photographs, but the validity of these measurements was not always demonstrated. Conclusion. Taking measurements of all body angles directly on the person is a lengthy process and may affect the reliability of the measurements. Measurement of body angles from photographs may be the most accurate and rapid way to assess global posture quantitatively in a clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Earlier studies on measurement of customer satisfaction are based on either transaction specific or overall approaches. The transaction specific approach evaluates customer satisfaction with single components in the whole purchase process but the overall satisfaction was based on all the encounters or experiences to the customer throughout the purchase process. Consumers will comment on particular events of their purchase process when asked about transaction-specific satisfaction and they will comment their overall impression and general experiences in overall satisfaction (Bitner & Hubbert 1994) Through a critical review on the literature, it has been identified a new approaches to customer satisfaction, say, cumulative approaches that can be more useful than overall and transaction specific approaches for strategic decision making (Fornell et al 1996). The cumulative approach to customer satisfaction doesn’t study earlier due to the difficulty in operationalization of the concept. But the influencers of customer satisfaction are context specific and the prevailing models doesn’t give the sources of variations in the satisfaction, the importance of cumulative approaches to customer satisfaction has emerges that lights to a new research. The current study has focused to explore the influencers of overall customer satisfaction to form individual elements that can be used to identify the cumulative customer satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three terminal ‘dotted-I’ interconnect structures, with vias at both ends and an additional via in the middle, were tested under various test conditions. Mortalities (failures) were found in right segments with jL value as low as 1250 A/cm, and the mortality of a dotted-I segment is dependent on the direction and magnitude of the current in the adjacent segment. Some mortalities were also found in the right segments under a test condition where no failure was expected. Cu extrusion along the delaminated Cu/Si₃N₄ interface near the central via region was believed to cause the unexpected failures. From the time-to-failure (TTF), it is possible to quantify the Cu/Si₃N₄ interfacial strength and bonding energy. Hence, the demonstrated test methodology can be used to investigate the integrity of the Cu dual damascene processes. As conventionally determined critical jL values in two-terminal via-terminated lines cannot be directly applied to interconnects with branched segments, this also serves as a good methodology to identify the critical effective jL values for immortality.