945 resultados para Scanning electronic microscope (SEM)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fibrous materials have morphological similarities to natural cartilage extracellular matrix and have been considered as candidate for bone tissue engineering scaffolds. In this study, we have evaluated a novel electrospun chitosan mat composed of oriented sub-micron fibers for its tensile property and biocompatibility with chondrocytes (cell attachment, proliferation and viability). Scanning electronic microscope images showed the fibers in the electrospun chitosan mats were indeed aligned and there was a slight cross-linking between the parent fibers. The electrospun mats have significantly higher elastic modulus (2.25 MPa) than the cast films (1.19 MPa). Viability of cells on the electrospun mat was 69% of the cells on tissue-culture polystyrene (TCP control) after three days in culture, which was slightly higher than that on the cast films (63% of the TCP control). Cells on the electrospun mat grew slowly the first week but the growth rate increased after that. By day 10, cell number on the electrospun mat was almost 82% that of TCP control, which was higher than that of cast films (56% of TCP). The electrospun chitosan mats have a higher Young’s modulus (P <0.01) than cast films and provide good chondrocyte biocompatibility. The electrospun chitosan mats, thus, have the potential to be further processed into three-dimensional scaffolds for cartilage tissue repair.
Resumo:
O presente trabalho de mestrado teve como meta realizar um estudo do comportamento do cobre particulado em ensaios tribológicos do tipo pino contra disco. O cobre é atualmente utilizado em até 15% em massa das pastilhas de freios automotivos e tal utilização é responsável pela emissão de até 70% do cobre particulado presente no ar. Devido ao caráter carcinogênico do cobre, se faz necessária sua substituição. Foram realizados ensaios tribológicos pino disco com adição de diferentes meios interfaciais. Foram utilizados pares tribológicos aço/aço, em ensaios a seco de pino contra disco com adição de meio interfacial nanoparticulado de óxido de ferro, grafite e de cobre metálico em diferentes granulometrias (400 m, 20 m e 50 nm). Após os ensaios, amostras das superfícies de pinos e discos para cada uma das adições de cobre, bem como para a condição sem adição de meio interfacial, foram caracterizadas utilizando técnicas de microscopia eletrônica de varredura, de forma a entender o comportamento das partículas de cobre e sua contribuição para o coeficiente de atrito. As adições de cobre obtiveram os maiores coeficientes de atrito, e entre elas os coeficientes de atrito foram mais altos durante todos os ensaios para a adição de 50 nm, seguido de 20 m e 400 m. A análise das superfícies tribológicas em MEV mostrou heterogeneidade das superfícies ensaiadas em relação à presença de debris oxidados e camadas compactas. Observou-se a presença de cobre apenas nas superfícies ensaiadas com adição dos cobres de 50 nm e 20 m. A presença de um filme óxido compacto e contínuo foi observada apenas nas superfícies tribológicas ensaiadas sem adição de meio interfacial e com adição de cobre a 400 m.
Resumo:
In this study, we test various parameters in deep-sea sediments (bulk sediment parameters and changes in microfossil abundances and preservation character) which are generally accepted as indicators of calcium carbonate dissolution. We investigate sediment material from station GeoB 1710-3 in the northern Cape Basin (eastern South Atlantic), 280 km away from the Namibian coast, well outside today's coastal upwelling. As northern Benguela upwelling cells were displaced westward and periodically preceded the core location during the past 245 kyr (Volbers et al., submitted), GeoB 1710-3 sediments reflect these changes in upwelling productivity. Results of the most commonly used calcium carbonate dissolution proxies do not only monitor dissolution within these calcareous sediments but also reflect changes in upwelling intensity. Accordingly, these conventional proxy parameters misrepresent, to some extent, the extent of calcium carbonate dissolution. These results were verified by an independent dissolution proxy, the Globigerina bulloides dissolution index (BDX') (Volbers and Henrich, 2002, doi:10.1016/S0025-3227(02)00333-X). The BDX' is based on scanning electronic microscope ultrastructural investigation of planktonic foraminiferal tests and indicates persistent good carbonate preservation throughout the past 245 kyr, with the exception of one pronounced dissolution event at early oxygen isotopic stage (OIS) 6. The early OIS 6 is characterized by calcium carbonate contents, sand contents, and planktonic foraminiferal concentrations all at their lowest levels for the last 245 kyr. At the same time, the ratio of radiolarian to planktonic foraminiferal abundances and the ratio of benthic to planktonic foraminiferal tests are strongly increased, as are the rain ratio, the fragmentation index, and the BDX'. The sedimentary calcite lysocline rose above the core position and GeoB 1710-3 sediments were heavily altered, as attested to by the unusual accumulation of pellets, aggregates, sponge spicules, radiolaria, benthic foraminifera, and planktonic foraminiferal assemblages. Solely the early OIS 6 dissolution event altered the coarse fraction intensely, and is therefore reflected by all conventional calcium carbonate preservation proxies and the BDX'. We attribute the more than 1000 m rise of the sedimentary calcite lysocline to the combination of two processes: (a) a prominent change in the deep-water mass distribution within the South Atlantic and (b) intense degradation of organic material within the sediment (preserved as maximum total organic carbon content) creating microenvironments favorable for calcium carbonate dissolution.
Resumo:
The present work shows a contribution to the studies of development and solid sinterization of a metallic matrix composite MMC that has as starter materials 316L stainless steel atomized with water, and two different Tantalum Carbide TaC powders, with averages crystallite sizes of 13.78 nm and 40.66 nm. Aiming the metallic matrix s density and hardness increase was added different nanometric sizes of TaC by dispersion. The 316L stainless steel is an alloy largely used because it s high resistance to corrosion property. Although, its application is limited by the low wear resistance, consequence of its low hardness. Besides this, it shows low sinterability and it cannot be hardened by thermal treatments traditional methods because of the austenitic structure, face centered cubic, stabilized mainly in nickel presence. Steel samples added with TaC 3% wt (each sample with different type of carbide), following a mechanical milling route using conventional mill for 24 hours. Each one of the resulted samples, as well as the pure steel sample, were compacted at 700 MPa, room temperature, without any addictive, uniaxial tension, using a 5 mm diameter cylindrical mold, and quantity calculated to obtain compacted final average height of 5 mm. Subsequently, were sintered in vacuum atmosphere, temperature of 1290ºC, heating rate of 20ºC/min, using different soaking times of 30 and 60 min and cooled at room temperature. The sintered samples were submitted to density and micro-hardness analysis. The TaC reforced samples showed higher density values and an expressive hardness increase. The complementary analysis in optical microscope, scanning electronic microscope and X ray diffractometer, showed that the TaC, processed form, contributed with the hardness increase, by densification, itself hardness and grains growth control at the metallic matrix, segregating itself to the grain boarders
Resumo:
Interstitial compounds of titanium have been mainly studied due to the large range of properties acquired when C, N, O and H atoms are added. In this work, surfaces of TiCxNy were produced by thermochemical treatments assisted by plasma with different proportions of Ar + N2 + CH4 gas mixture. The Ar gas flow was fixed in 4 sccm, varying only N2 and CH4 gas flows. During the thermochemical treatment, the plasma was monitored by Optical Emission Spectroscopy (OES) for the investigation of the influence of active species. After treatments, C and N concentration profile, crystalline and amorphous phases were analyzed by Nuclear Reaction (NRA). Besides tribomechanical properties of the Ti surface were studied through the nanohardness measurements and friction coefficient determination. The worn areas were evaluated by profilometry and Scanning Electronic Microscope (SEM) in order to verify the wear mechanism present in each material. It has been seen which the properties like nanohardness and friction coefficient have strong relation with luminous intensity of species of the plasma, suggesting a using of this characteristic as a parameter of process
Resumo:
The use of adhesives to join two different substrates is an efficient replacement to classic joining technologies such as welding and soldering. One the one hand adhesion has different advantages over those techniques such as an improved stress distribution and the potential weight reduction of the structure; on the other hand, two of the most important drawbacks are a relatively low fracture toughness and the need of an accurate surface preparation. These two aspects will be accurately analysed in the present work: the use of Nylon nanofibers as reinforcement for the adhesive should increase fracture toughness, while a surface preparation method consisting of mechanical and chemical treatments will be developed. After the specimens are produced, they will be tested in mode I fracture using a DCB (Double Beam Cantilever) test, which allows to measure the fracture toughness during crack propagation. At the end of the test, the surfaces of the adherends will be visually observed and SEM (Scanning Electronic Microscope) analysed in order to evaluate if adhesive or cohesive fracture occurred, and thus if surface treatments has been well developed to allow a better adhesive-aluminium joining.
Resumo:
Since the end of the last millennium, the focused ion beam scanning electron microscopy (FIB-SEM) has progressively found use in biological research. This instrument is a scanning electron microscope (SEM) with an attached gallium ion column and the 2 beams, electrons and ions (FIB) are focused on one coincident point. The main application is the acquisition of three-dimensional data, FIB-SEM tomography. With the ion beam, some nanometres of the surface are removed and the remaining block-face is imaged with the electron beam in a repetitive manner. The instrument can also be used to cut open biological structures to get access to internal structures or to prepare thin lamella for imaging by (cryo-) transmission electron microscopy. Here, we will present an overview of the development of FIB-SEM and discuss a few points about sample preparation and imaging.
Resumo:
La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.
Resumo:
The electronic gap structure of the organic molecule N,N′-diphenyl-N,N′-bis(3-methylphenyl)-(1,1′-biphenyl)-4,4′-diamine, also known as TPD, has been studied by means of a Scanning Tunneling Microscope (STM) and by Photoluminescence (PL) analysis. Hundreds of current-voltage characteristics measured at different spots of the sample show the typical behavior of a semiconductor. The analysis of the curves allows to construct a gap distribution histogram which reassembles the PL spectrum of this compound. This analysis demonstrates that STM can give relevant information, not only related to the expected value of a semiconductor gap but also on its distribution which affects its physical properties such as its PL.
Resumo:
Electronic nicotine delivery systems (ENDS) use has recently grown. E-cig generates carcinogenic chemical compounds and reactive oxygen species (ROS). Carbonyls and ROS are formed when the liquid comes into contact with the heating element. In this study the chemical and biological effects of coil resistance applied on the same device were investigated. A preliminary in-vivo study the new heat-not-burn devices (IQOS®) has been conducted to evaluate the effect of the device on antioxidant biomarkers. The amount of formaldehyde, acetaldehyde, acrolein was measured by GC-MS analysis. The two e-liquids used for carbonyls detection differed only for the presence of nicotine. The nicotine-free liquid was then used for the detection of ROS in the aerosol. The impact of the non-nicotine vapor on cell viability in H1299 human lung carcinoma cells, as well as the biological effects in a rat model of e-cig aerosol exposure, were also evaluated. After the exposure of Sprague Dawley rats to e-cig and IQOS® aerosol, the effect of 28-day treatment was examined on enzymatic and non-enzymatic antioxidant response, lung inflammation, blood homeostasis and tissue damage by using scanning electron microscope (SEM) technique. The results show a significant correlation between the low resistance and the generation of higher concentrations of the selected carbonyls and ROS in aerosols. Cell viability was reduced with an inverse relation to coil resistance. The experimental model highlighted an impairment of the pulmonary antioxidant and detoxifying machinery. Frames from SEM show disorganization of alveolar and bronchial epithelium. IQOS® exposed animals shows a significant production of ROS related to the unbalance of antioxidant defense and alteration of macromolecule integrity. This research demonstrates how several toxicological aspects can potentially occur in e-cig consumers who use low resistance device coupled with nicotine-free liquid. ENDS may expose users to hazardous compounds, which, may promote chronic pathologies and degenerative diseases.
Resumo:
This in situ study investigated, using scanning electron microscopy, the effect of stimulated saliva on the enamel surface of bovine and human substrates submitted to erosion followed by brushing abrasion immediately or after one hour. During 2 experimental 7-day crossover phases, 9 previously selected volunteers wore intraoral palatal devices, with 12 enamel specimens (6 human and 6 bovine). In the first phase, the volunteers immersed the device for 5 minutes in 150 ml of a cola drink, 4 times a day (8h00, 12h00, 16h00 and 20h00). Immediately after the immersions, no treatment was performed in 4 specimens (ERO), 4 other specimens were immediately brushed (0 min) using a fluoride dentifrice and the device was replaced into the mouth. After 60 min, the other 4 specimens were brushed. In the second phase, the procedures were repeated but, after the immersions, the volunteers stimulated the salivary flow rate by chewing a sugar-free gum for 30 min. Enamel superficial alterations of all specimens were then evaluated using a scanning electron microscope. Enamel prism core dissolution was seen on the surfaces submitted to erosion, while on those submitted to erosion and to abrasion (both at 0 and 60 min) a more homogeneous enamel surface was observed, probably due to the removal of the altered superficial prism layer. For all the other variables - enamel substrate and salivary stimulation -, the microscopic pattern of the enamel specimens was similar.
Resumo:
Quantum adiabatic pumping of charge and spin between two reservoirs (leads) has recently been demonstrated in nanoscale electronic devices. Pumping occurs when system parameters are varied in a cyclic manner and sufficiently slowly that the quantum system always remains in its ground state. We show that quantum pumping has a natural geometric representation in terms of gauge fields (both Abelian and non-Abelian) defined on the space of system parameters. Tunneling from a scanning tunneling microscope tip through a magnetic atom could be used to demonstrate the non-Abelian character of the gauge field.
Resumo:
This study compared ultrasonic chemical vapor deposition (CVD)-coated tip (CVDentus #8.1117-1; Clorovale Diamantes Ind. e Com. Ltda Epp, Sao Jose dos Campos, SP, Brazil) versus high-speed (#FG700L) and low-speed (#699) carbide burs for apicoectomy, evaluating the time required for resection and analyzing the root-end surfaces by scanning electron microscopy. Thirty extracted human premolars had the canals instrumented and obturated and were randomly assigned to 3 groups (n = 10), according to the instrument used for root-end resection. The time required for resection of the apical 2 mm of each root was recorded. The resected apical segments were dried, sputter coated with gold, and examined with a scanning electron microscope at X 350 magnification. A four-point (0-3) scoring system was used to evaluate the apical surface smoothness. The results were analyzed statistically by the Kruskal-Wallis test and two-by-two comparisons analyses were performed using the Miller test. The significance level was set at 5%. Root-end resection with the high-speed bur was significantly faster (p < 0.05) compared with the low-speed bur and CVD tip. The carbide burs produced significantly smoother root-end surfaces than the CVD tip (p < 0.05). The low-speed bur produced the smoothest root-end surfaces, whereas the roughest and most irregular root ends (p < 0.05) were obtained with the CVD tip. However, no statistically significant difference (p > 0.05) was found between the high- and low-speed burs regarding the surface roughness of the resected root ends (p > 0.05). In conclusion, under the tested conditions, ultrasonic root-end resection took a longer time and resulted in rougher surfaces compared with the use of carbide burs at both high and low speed. (J Endod 2009;35:265-268)