919 resultados para Sacroiliac Joint
Resumo:
Background: In vitro investigations have demonstrated the importance of the ribcage in stabilising the thoracic spine. Surgical alterations of the ribcage may change load-sharing patterns in the thoracic spine. Computer models are used in this study to explore the effect of surgical disruption of the rib-vertebrae connections on ligament load-sharing in the thoracic spine. Methods: A finite element model of a T7-8 motion segment, including the T8 rib, was developed using CT-derived spinal anatomy for the Visible Woman. Both the intact motion segment and the motion segment with four successive stages of destabilization (discectomy and removal of right costovertebral joint, right costotransverse joint and left costovertebral joint) were analysed for a 2000Nmm moment in flexion/extension, lateral bending and axial rotation. Joint rotational moments were compared with existing in vitro data and a detailed investigation of the load sharing between the posterior ligaments carried out. Findings: The simulated motion segment demonstrated acceptable agreement with in vitro data at all stages of destabilization. Under lateral bending and axial rotation, the costovertebral joints were of critical importance in resisting applied moments. In comparison to the intact joint, anterior destabilization increases the total moment contributed by the posterior ligaments. Interpretation: Surgical removal of the costovertebral joints may lead to excessive rotational motion in a spinal joint, increasing the risk of overload and damage to the remaining ligaments. The findings of this study are particularly relevant for surgical procedures involving rib head resection, such as some techniques for scoliosis deformity correction.
Resumo:
When compared with other arthoplasties, Total Ankle Joint Replacement (TAR) is much less successful. Attempts to remedy this situation by modifying the implant design, for example by making its form more akin to the original ankle anatomy, have largely met with failure. One of the major obstacles is a gap in current knowledge relating to ankle joint force. Specifically this is the lack of reliable data quantifying forces and moments acting on the ankle, in both the healthy and diseased joints. The limited data that does exist is thought to be inaccurate [1] and is based upon simplistic two dimensional discrete and outdated techniques.
Resumo:
Inspection of solder joints has been a critical process in the electronic manufacturing industry to reduce manufacturing cost, improve yield, and ensure project quality and reliability. This paper proposes the use of the Log-Gabor filter bank, Discrete Wavelet Transform and Discrete Cosine Transform for feature extraction of solder joint images on Printed Circuit Boards (PCBs). A distance based on the Mahalanobis Cosine metric is also presented for classification of five different types of solder joints. From the experimental results, this methodology achieved high accuracy and a well generalised performance. This can be an effective method to reduce cost and improve quality in the production of PCBs in the manufacturing industry.
Resumo:
The purpose of this study was to determine the effects of cryotherapy, in the form of cold water immersion, on knee joint position sense. Fourteen healthy volunteers, with no previous knee injury or pre-existing clinical condition, participated in this randomized cross-over trial. The intervention consisted of a 30-min immersion, to the level of the umbilicus, in either cold (14 ± 1°C) or tepid water(28 ± 1°C). Approximately one week later, in a randomized fashion, the volunteers completed the remaining immersion. Active ipsilateral limb repositioning sense of the right knee was measured, using weight-bearing and non-weight bearing assessments, employing video-recorded 3D motion analysis. These assessments were conducted immediately before and after a cold and tepid water immersion. No significant differences were found between treatments for the absolute (P = 0.29), relative (P = 0.21) or variable error (P = 0.86). The average effect size of the outcome measures was modest (range –0.49 to 0.9) and all the associated 95% confidence intervals for these effect sizes crossed zero. These results indicate that there is no evidence of an enhanced risk of injury, following a return to sporting activity, after cold water.
Resumo:
Objective: To (1) search the English-language literature for original research addressing the effect of cryotherapy on joint position sense (JPS) and (2) make recommendations regarding how soon healthy athletes can safely return to participation after cryotherapy. Data Sources: We performed an exhaustive search for original research using the AMED, CINAHL, MEDLINE, and SportDiscus databases from 1973 to 2009 to gather information on cryotherapy and JPS. Key words used were cryotherapy and proprioception, cryotherapy and joint position sense, cryotherapy, and proprioception. Study Selection: The inclusion criteria were (1) the literature was written in English, (2) participants were human, (3) an outcome measure included JPS, (4) participants were healthy, and (5) participants were tested immediately after a cryotherapy application to a joint. Data Extraction: The means and SDs of the JPS outcome measures were extracted and used to estimate the effect size (Cohen d) and associated 95% confidence intervals for comparisons of JPS before and after a cryotherapy treatment. The numbers, ages, and sexes of participants in all 7 selected studies were also extracted. Data Synthesis: The JPS was assessed in 3 joints: ankle (n 5 2), knee (n 5 3), and shoulder (n 5 2). The average effect size for the 7 included studies was modest, with effect sizes ranging from 20.08 to 1.17, with a positive number representing an increase in JPS error. The average methodologic score of the included studies was 5.4/10 (range, 5–6) on the Physiotherapy Evidence Database scale. Conclusions: Limited and equivocal evidence is available to address the effect of cryotherapy on proprioception in the form of JPS. Until further evidence is provided, clinicians should be cautious when returning individuals to tasks requiring components of proprioceptive input immediately after a cryotherapy treatment.
Resumo:
This paper presents the results of a recent investigation into Insulated Rail Joint Tie Plate fatigue failures. In particular it focuses on the results of data obtained through field strain gauge and accelerometer measurements of in-service Insulated Rail Joint Tie Plates. These measurements have identified a significant variability in the strains present in similar joints operating under identical load conditions. This variability in stress invariably has a significant influence on the life of the joints. The results of rainflow counting and a fatigue analysis are also presented.
Resumo:
The standard Exeter stem has a length of 150mm with offsets 37.5mm to 56mm. Shorter stems of lengths 95mm, 115mm and 125mm with offsets 35.5mm or less are available for patients with smaller femurs. Concern has been raised regarding the behaviour of the smaller implants. This paper analysed data from the Australian Orthopaedic Association National Joint Replacement Registry comparing survivorship of stems of offset 35.5mm or less with the standard stems of 37.5mm offset or greater. At seven years there was no significant difference in the Cumulative Percent Revision Rate in the short stems (3.4%, 95% CI 2.4-4.8%) compared with the standard length stems (3.5%, 95% CI 3.3-3.8%) despite its use in a greater proportion of potentially more difficult developmental dysplasia of the hip cases.
Resumo:
When wheels pass over insulated rail joints (IRJs) a vertical impact force is generated. The ability to measure the impact force is valuable as the force signature helps understand the behaviour of the IRJs, in particular their potential for failure. The impact forces are thought to be one of the main factors that cause damage to the IRJ and track components. Study of the deterioration mechanism helps finding new methods to improve the service life of IRJs in track. In this research, the strain-gage-based wheel load detector, for the first time, is employed to measure the wheel–rail contact-impact force at an IRJ in a heavy haul rail line. In this technique, the strain gages are installed within the IRJ assembly without disturbing the structural integrity of IRJ and arranged in a full wheatstone bridge to form a wheel load detector. The instrumented IRJ is first tested and calibrated in the lab and then installed in the field. For comparison purposes, a reference rail section is also instrumented with the same strain gage pattern as the IRJ. In this paper the measurement technique, the process of instrumentation, and tests as well as some typical data obtained from the field and the inferences are presented.
Resumo:
This submission addresses the following terms of reference: 1) the nature, prevalence and level of cybersafety risks and threats experienced by senior Australians; 2) the impact and implications of those risks and threats on access and use of information and communication technologies by senior Australians; 3) the adequacy and effectiveness of current government and industry initiatives to respond to those threats, including education initiatives aimed at senior Australians; 4) best practice safeguards, and any possible changes to Australian law, policy or practice that will strengthen the cybersafety of senior Australians.
Resumo:
Following on from the 2nd edition published in 2005, this new edition updates its predecessor and adds considerable new material as a result of changes in the law generally and commercial approaches to financing joint ventures in particular. Of special note, Financing of Joint Ventures has been completely re-written with considerable additions to take account of the new legislative regimes such as the Personal Property Securities. The impact of climate change legislation has been covered, specifically carbon pricing with additional material on structuring generally and particularly in relation to large joint ventures with governments through Public Private Partnerships. A new Chapter has been added called Resources Joint Ventures and undertakes a thorough analysis of a typical resources joint venture and is heavily cross referenced into the chapter on Default which has also been updated. In addition, International Joint Ventures now includes additional material on structuring and dispute resolution and Joint Ventures and the Competition and Consumer Act has been substantially re-written to take account of 2009 legislative amendments on cartel conduct, and the impact of changes wrought by the Competition and Consumer Act 2010. All other chapters and material has been updated to accommodate other legislative changes and new case law over the seven years since the last edition.
Resumo:
This chapter is devoted to the issue of non-fiduciary common law obligations of good faith, as they may arise in the performance and enforcement of joint ventures. In recent times a rush of commercial contractual claims involving good faith has signified the need for a separate chapter examining this issue. Although most of these decisions have arisen in commercial contexts other than joint ventures, the decisions, nevertheless, warrant careful consideration to the extent that they cast light on the likely contours of the common law good faith obligation as it may apply in the joint venture context.
Resumo:
The purpose of this chapter is to analyse the way in which joint venture agreements can fall within the competition provisions of the Competition and Consumer Act 2010, and the circumstances in which authorisation may be available for joint venture collaborations.
Resumo:
Following upon the success of the 2nd edition published in 2005, this new edition not only updates its predecessor but also adds considerable new material in consequences of changes in the law generally and commercial approaches to financing joint ventures in particular. Of special note are the following: Financing of Joint Ventures has been completely re-written with considerable additions to take account of the new legislative regimes such as the Personal Property Securities, the impact of climate change legislation, specifically carbon pricing with additional material on structuring generally and particularly in relation to large joint ventures with governments through Public Private Partnerships. A new Chapter called Resources Joint Ventures undertakes a thorough analysis of a typical resources joint venture and is heavily cross referenced into the chapter on Default which has also been updated. International Joint Ventures now includes additional material on structuring and dispute resolution. Joint Ventures and the Competition and Consumer Act has been substantially re-written to take account of 2009 legislative amendments on cartel conduct, and the impact of changes wrought by the Competition and Consumer Act 2010. All other chapters and material has been updated to accommodate other legislative changes and new case law over the seven years since the last edition.
Resumo:
At common law, a corporation may be liable vicariously for the conduct of its appointed agents, employees or directors. This generally requires the agent or employee to be acting in the course of his or her agency or employment and, in the case of representations, to have actual or implied authority to make the representations. The circumstances in which a corporation may be liable for the conduct of its agents, employees or directors is broadened under the Australian Consumer Law (ACL) to where one of these parties engages in conduct “on behalf of” the corporation. As the decision in Bennett v Elysium Noosa Pty Ltd (in liq) demonstrates, this may extend to liability for the misleading conduct of a salesperson for the joint venture to parties who are not formal members of the joint venture, but where the joint venture activities are within the course of the entity’s “business, affairs or activities”.