989 resultados para SCREENING ACCURACY
Resumo:
Background Tools to explore large compound databases in search for analogs of query molecules provide a strategically important support in drug discovery to help identify available analogs of any given reference or hit compound by ligand based virtual screening (LBVS). We recently showed that large databases can be formatted for very fast searching with various 2D-fingerprints using the city-block distance as similarity measure, in particular a 2D-atom pair fingerprint (APfp) and the related category extended atom pair fingerprint (Xfp) which efficiently encode molecular shape and pharmacophores, but do not perceive stereochemistry. Here we investigated related 3D-atom pair fingerprints to enable rapid stereoselective searches in the ZINC database (23.2 million 3D structures). Results Molecular fingerprints counting atom pairs at increasing through-space distance intervals were designed using either all atoms (16-bit 3DAPfp) or different atom categories (80-bit 3DXfp). These 3D-fingerprints retrieved molecular shape and pharmacophore analogs (defined by OpenEye ROCS scoring functions) of 110,000 compounds from the Cambridge Structural Database with equal or better accuracy than the 2D-fingerprints APfp and Xfp, and showed comparable performance in recovering actives from decoys in the DUD database. LBVS by 3DXfp or 3DAPfp similarity was stereoselective and gave very different analogs when starting from different diastereomers of the same chiral drug. Results were also different from LBVS with the parent 2D-fingerprints Xfp or APfp. 3D- and 2D-fingerprints also gave very different results in LBVS of folded molecules where through-space distances between atom pairs are much shorter than topological distances. Conclusions 3DAPfp and 3DXfp are suitable for stereoselective searches for shape and pharmacophore analogs of query molecules in large databases. Web-browsers for searching ZINC by 3DAPfp and 3DXfp similarity are accessible at www.gdb.unibe.ch webcite and should provide useful assistance to drug discovery projects.
Resumo:
Diagnosis of primary ciliary dyskinesia (PCD) lacks a "gold standard" test and is therefore based on combinations of tests including nasal nitric oxide (nNO), high-speed video microscopy analysis (HSVMA), genotyping and transmission electron microscopy (TEM). There are few published data on the accuracy of this approach.Using prospectively collected data from 654 consecutive patients referred for PCD diagnostics we calculated sensitivity and specificity for individual and combination testing strategies. Not all patients underwent all tests.HSVMA had excellent sensitivity and specificity (100% and 93%, respectively). TEM was 100% specific, but 21% of PCD patients had normal ultrastructure. nNO (30 nL·min(-1) cut-off) had good sensitivity and specificity (91% and 96%, respectively). Simultaneous testing using HSVMA and TEM was 100% sensitive and 92% specific.In conclusion, combination testing was found to be a highly accurate approach for diagnosing PCD. HSVMA alone has excellent accuracy, but requires significant expertise, and repeated sampling or cell culture is often needed. TEM alone is specific but misses 21% of cases. nNO (≤30 nL·min(-1)) contributes well to the diagnostic process. In isolation nNO screening at this cut-off would miss ∼10% of cases, but in combination with HSVMA could reduce unnecessary further testing. Standardisation of testing between centres is a future priority.
Resumo:
Purpose. Recent reports reveals that studies of decision aids reported concern about the balance and accuracy of information included in decision aids. This study explores measures of balance in patient decision aids through a review of prostate cancer screening decision aid studies and analysis of patients’ rating of a patient decision aid for prostate cancer screening. ^ Methods. A data-abstraction form was used to collect the key characteristics, pertaining to balance, of studies included in the review. The key characteristics included (1) sample characteristics (age, race, family history of prostate cancer, and education), (2) description of the decision aid and how it was implemented, and (3) if a measure of balance was used for process evaluation and the rating. A summary table was used to report the findings. Deidentified data was received from a decision aid control trial and logistic regression analysis was used to test the association between the dependent variable (balance) and the independent variables (age, family history, race, screening preference at baseline, education, health insurance status). ^ Conclusion. Three sociodemographic variables remained significant in the final regression model: African American race, education and PSA history. Further research is needed to determine if these variables can predict a man’s perception of balance in prostate cancer screening decision aids. If a patient’s perceptions of balance can be predicted based on specific characteristics, patient report may not be the most objective method of evaluating the acceptability of a decision.^
Resumo:
Background: Early and effective identification of developmental disorders during childhood remains a critical task for the international community. The second highest prevalence of common developmental disorders in children are language delays, which are frequently the first symptoms of a possible disorder. Objective: This paper evaluates a Web-based Clinical Decision Support System (CDSS) whose aim is to enhance the screening of language disorders at a nursery school. The common lack of early diagnosis of language disorders led us to deploy an easy-to-use CDSS in order to evaluate its accuracy in early detection of language pathologies. This CDSS can be used by pediatricians to support the screening of language disorders in primary care. Methods: This paper details the evaluation results of the ?Gades? CDSS at a nursery school with 146 children, 12 educators, and 1 language therapist. The methodology embraces two consecutive phases. The first stage involves the observation of each child?s language abilities, carried out by the educators, to facilitate the evaluation of language acquisition level performed by a language therapist. Next, the same language therapist evaluates the reliability of the observed results. Results: The Gades CDSS was integrated to provide the language therapist with the required clinical information. The validation process showed a global 83.6% (122/146) success rate in language evaluation and a 7% (7/94) rate of non-accepted system decisions within the range of children from 0 to 3 years old. The system helped language therapists to identify new children with potential disorders who required further evaluation. This process will revalidate the CDSS output and allow the enhancement of early detection of language disorders in children. The system does need minor refinement, since the therapists disagreed with some questions from the CDSS knowledge base (KB) and suggested adding a few questions about speech production and pragmatic abilities. The refinement of the KB will address these issues and include the requested improvements, with the support of the experts who took part in the original KB development. Conclusions: This research demonstrated the benefit of a Web-based CDSS to monitor children?s neurodevelopment via the early detection of language delays at a nursery school. Current next steps focus on the design of a model that includes pseudo auto-learning capacity, supervised by experts.
Resumo:
To improve the accuracy of predicting membrane protein sorting signals, we developed a general methodology for defining trafficking signal consensus sequences in the environment of the living cell. Our approach uses retroviral gene transfer to create combinatorial expression libraries of trafficking signal variants in mammalian cells, flow cytometry to sort cells based on trafficking phenotype, and quantitative trafficking assays to measure the efficacy of individual signals. Using this strategy to analyze arginine- and lysine-based endoplasmic reticulum localization signals, we demonstrate that small changes in the local sequence context dramatically alter signal strength, generating a broad spectrum of trafficking phenotypes. Finally, using sequences from our screen, we found that the potency of di-lysine, but not di-arginine, mediated endoplasmic reticulum localization was correlated with the strength of interaction with α-COP.
Resumo:
Screening by whole-body clinical skin examination may improve early diagnosis of melanoma and reduce mortality, but objective scientific evidence of this is lacking. As part of a randomized controlled trial of population screening for melanoma in Queensland, Australia, the authors assessed the validity of self-reported history of whole-body skin examination and factors associated with accuracy of recall among 2,704 participants in 2001. Approximately half of the participants were known to have undergone whole-body skin examination within the past 3 years at skin screening clinics conducted as part of the randomized trial. All positive and negative self-reports were compared with screening clinic records. Where possible, reports of skin examinations conducted outside the clinics were compared with private medical records. The validity of self-reports of whole-body skin examination in the past 3 years was high: Concordance between self-reports and medical records was 93.7%, sensitivity was 92.0%, and specificity was 96.3%. Concordance was lower (74.3%) for self-reports of examinations conducted in the past 12 months, and there was evidence of telescoping in recall for this more recent time frame. In multivariate analysis, women and younger participants more accurately recalled their history of skin examinations. Participants with a history of melanoma did not differ from other participants in their accuracy of recall.
Resumo:
Background Cardiac disease is the principal cause of death in patients with chronic kidney disease (CKD). Ischemia at dobutamine stress echocardiography (DSE) is associated with adverse events in these patients. We sought the efficacy of combining clinical risk evaluation with DSE. Methods We allocated 244 patients with CKD (mean age 54 years, 140 men, 169 dialysis-dependent at baseline) into low- and high-risk groups based on two disease-specific scores and the Framingham risk model. All underwent DSE and were further stratified according to DSE results. Patients were followed over 20 +/- 14 months for events (death, myocardial infarction, acute coronary syndrome). Results There were 49 deaths and 32 cardiac events. Using the different clinical scores, allocation of high risk varied from 34% to 79% of patients, and 39% to 50% of high-risk patients had an abnormal DSE. In the high-risk groups, depending on the clinical score chosen, 25% to 44% with an abnormal DSE had a cardiac event, compared with 8% to 22% with a.normal DSE. Cardiac events occurred in 2.0%, 3.1 %, and 9.7% of the low-risk patients, using the two disease-specific and Framingham scores, respectively, and DSE results did not add to risk evaluation in this subgroup. Independent DSE predictors of cardiac events were a lower resting diastolic blood pressure, angina during the test, and the combination of ischemia with resting left ventricular dysfunction. Conclusion In CKD patients, high-risk findings by DSE can predict outcome. A stepwise strategy of combining clinical risk scores with DSE for CAD screening in CKD reduces the number of tests required and identifies a high-risk subgroup among whom DSE results more effectively stratify high and low risk.
Resumo:
OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.
Resumo:
Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.
Resumo:
Measurement of marine algal toxins has traditionally focussed on shellfish monitoring while, over the last decade, passive sampling has been introduced as a complementary tool for exploratory studies. Since 2011, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been adopted as the EU reference method (No.15/2011) for detection and quantitation of lipophilic toxins. Traditional LC-MS approaches have been based on low-resolution mass spectrometry (LRMS), however, advances in instrument platforms have led to a heightened interest in the use of high-resolution mass spectrometry (HRMS) for toxin detection. This work describes the use of HRMS in combination with passive sampling as a progressive approach to marine algal toxin surveys. Experiments focused on comparison of LRMS and HRMS for determination of a broad range of toxins in shellfish and passive samplers. Matrix effects are an important issue to address in LC-MS; therefore, this phenomenon was evaluated for mussels (Mytilus galloprovincialis) and passive samplers using LRMS (triple quadrupole) and HRMS (quadrupole time-of-flight and Orbitrap) instruments. Matrix-matched calibration solutions containing okadaic acid and dinophysistoxins, pectenotoxin, azaspiracids, yessotoxins, domoic acid, pinnatoxins, gymnodimine A and 13-desmethyl spirolide C were prepared. Similar matrix effects were observed on all instruments types. Most notably, there was ion enhancement for pectenotoxins, okadaic acid/dinophysistoxins on one hand, and ion suppression for yessotoxins on the other. Interestingly, the ion selected for quantitation of PTX2 also influenced the magnitude of matrix effects, with the sodium adduct typically exhibiting less susceptibility to matrix effects than the ammonium adduct. As expected, mussel as a biological matrix, quantitatively produced significantly more matrix effects than passive sampler extracts, irrespective of toxin. Sample dilution was demonstrated as an effective measure to reduce matrix effects for all compounds, and was found to be particularly useful for the non-targeted approach. Limits of detection and method accuracy were comparable between the systems tested, demonstrating the applicability of HRMS as an effective tool for screening and quantitative analysis. HRMS offers the advantage of untargeted analysis, meaning that datasets can be retrospectively analysed. HRMS (full scan) chromatograms of passive samplers yielded significantly less complex data sets than mussels, and were thus more easily screened for unknowns. Consequently, we recommend the use of HRMS in combination with passive sampling for studies investigating emerging or hitherto uncharacterised toxins.
Resumo:
Mushrooms have the ability to promote apoptosis in tumor cell lines, but the mechanism of action is not quite well understood. Inhibition of the interaction between Bcl-2 and pro-apoptotic proteins could be an important step that leads to apoptosis. Therefore, the discovery of compounds with the ability to inhibit Bcl-2 is an ongoing research topic in drug discovery. In this study, we started by analyzing Bcl-2 experimental structures that are currently available in Protein Data Bank database. After analysis of the more relevant Bcl-2 structures, 4 were finally selected. An analysis of the best docking methodology was then performed using a cross-docking and re-docking approach while testing 2 docking softwares: AutoDock 4 and AutoDock Vina. Autodock4 provided the best docking results and was selected to perform a virtual screening study applied to a dataset of 40 Low Molecular Weight (LMW) compounds present in mushrooms, using the selected Bcl-2 structures as target. Results suggest that steroid are the more promising family, among the analyzed compounds, and may have the ability to interact with Bcl-2 and this way promoting tumor apoptosis. The steroids that presented lowest estimated binding energy (ΔG) were: Ganodermanondiol, Cerevisterol, Ganoderic Acid X and Lucidenic Lactone; with estimated ΔG values between -8,45 and -8,23 Kcal/mol. A detailed analysis of the docked conformation of these 4 top ranked LMW compounds was also performed and illustrates a plausible interaction between the 4 top raked steroids and Bcl-2, thus substantiating the accuracy of the predicted docked poses. Therefore, tumoral apoptosis promoted by mushroom might be related to Bcl-2 inhibition mediated by steroid family of compounds.
Resumo:
Virtual Screening (VS) methods can considerably aid clinical research, predicting how ligands interact with drug targets. However, the accuracy of most VS methods is constrained by limitations in the scoring function that describes biomolecular interactions, and even nowadays these uncertainties are not completely understood. In order to improve accuracy of scoring functions used in most VS methods we propose a hybrid novel approach where neural networks (NNET) and support vector machines (SVM) methods are trained with databases of known active (drugs) and inactive compounds, this information being exploited afterwards to improve VS predictions.
Resumo:
Background In 2009 Malawi introduced a new protocol to screen potential blood donors for anaemia, using the WHO Haemoglobin Colour Scale (HCS) for initial screening. Published studies of the accuracy of the HCS to screen potential blood donors show varying levels of accuracy and opinion varies whether this is an appropriate screening test. The aim of the study was to assess the validity of the HCS, as a screening test, by comparison to HemoCue in potential blood donors in Malawi. Study design and Methods This was a blinded prospective study in potential blood donors aged over 18 years, at Malawi Blood Transfusion Service in Blantyre, Malawi. Capillary blood samples were analysed using the HCS and HemoCue, independent of each other. The sensitivity and specificity of correctly identifying ineligible blood donors (Hb≤12g/dL) were calculated. Results From 242 participants 234 (96.7%) were correctly allocated and 8 (3.3%), were wrongly allocated on the basis of the Haemoglobin Colour Scale (HCS) compared to HemoCue, all were subjects that were wrongly accepted as donors when their haemoglobin results were ≤12.0g/dL. This gave a sensitivity of 100% and specificity of 96.7% to detect donor eligibilty. The negative predictive value of the HCS was 100% but the positive predictive value to identify ineligible donors on the basis of anaemia was only 20%. Conclusions Initial screening with the HCS correctly predicts eligibility for blood donation in the majority of potential blood donors at considerable cost saving compared with use of HemoCue as the first line anaemia screening test, however, by this method a small number of anaemic patients were allowed to donate blood.
Resumo:
Background: Incidence of jaundice is high in newborn infants. Since well appearing newborns are rapidly and routinely discharged from hospital, performing an inexpensive noninvasive pre-discharge screening test for evaluation of jaundice seems to be necessary. Objectives: This study was conducted to compare the accuracy of cutaneous v/s serum bilirubin measurements in this regard. Patients and Methods: This was a prospective cross sectional study conducted in Mahdieh hospital, Tehran. 613 neonates weighing ≥ 1,800 g with gestational age of ≥ 35 weeks were enrolled. A pre discharge transcutaneous bilirubin test (TcB) was performed in all. Serum samples were taken from neonates with TcB ≥ 5 mg/dL in first and > 8 mg/dL in second 24 hours. Decision for treatment or recheck of bilirubin level after discharge was made based on serum bilirubin results. Results: Based on the study protocol, among 613 studied neonates, 491 (80%) revealed high TcB, of them 240 (49%) cases showed TBC ≥ 5 mg/dL in first and 251 (51 %) in second pre-discharge 24 hours. TcB ranged 3.3 - 17.1, mean TcB in first 24 hours was 6.9 ± 1 .7 (mode 6) and in second 24 hours 9.1 ± 2.1 (mode 10). Of 491 neonates with high TcB, capillary serum sample was taken as the second step and 398 neonates revealed high total serum bilirubin (TsB) with the same protocol for TcB. 108 (27.1%) neonates showed TsB ≥ 5 mg/dL in first and 290 (72.9%) in second 24 hours. According to the study results TcB has a 81% positive predictive value (PPV) in diagnosis of hyperbilirubinemia. Correlation coefficient of TcB and TsB in highest rate is equal to 72% (P value < 0.001). Conclusions: TcB is an inexpensive, noninvasive and precise pre-discharge screening test for evaluation of hyperbilirubinemia, with a high PPV. It is highly recommended to be performed routinely due to high incidence of hyperbilirubinemia in neonates.
Resumo:
Predicting risk of adverse healthcare outcomes is important to enable targeted delivery of interventions. The Risk Instrument for Screening in the Community (RISC), designed for use by public health nurses (PHNs), measures the one-year risk of hospitalisation, institutionalisation and death in community-dwelling older adults according to a five-point global risk score: from low (score 1,2), medium (3) and high (4,5). We examined the inter-rater reliability (IRR) of the RISC between student PHNs (n=32) and expert raters using six cases (two low, medium and high-risk), scored before and after RISC training. Correlations increased for each adverse outcome, statistically significantly for institutionalisation (r=0.72 to 0.80,p=0.04) and hospitalisation, (r=0.51 to 0.71,p<0.01) but not death. Training improved accuracy for low-risk but not all high-risk cases. Overall, the RISC showed good IRR, which increased after RISC training. That reliability reduced for some high-risk cases suggests that the training programme requires adjustment to further improve IRR.