887 resultados para Robotic Assisted Minimally Invasive Surgery (RAMIS)
Resumo:
Residents learning nontechnical skills in Europe face two problems: (1) the difficulty to fit learning time in their overloaded schedules; and (2) the lack of standard pedagogical models for all countries. Online video-based repositories such as WeBSurg or WebOP provide ubiquitous access to surgical contents. However, their pedagogical facets have not been fully exploited and they are often seen as quick-reference repositories rather than full e-learning alternatives. We present a new pedagogically-supported Technology Enhanced Learning (TEL) solution, MISTELA, designed by surgeons, pedagogical experts and engineers. MISTELA aims at building a common European pedagogical model supported by ICT technologies and elearning. The solution proposes a pedagogical model based on a framework for pedagogically-informed design of e-learning platforms. It is composed of (1) an authoring tool for editing and augmenting videos; (2) a media asset management system; and (3) a virtual learning environment. Support of the European Association for Endoscopic Surgery (EAES) and validation of the solution, will help to determine its full potential.
Resumo:
To compare intraoperative cerebral microembolic load between minimally invasive extracorporeal circulation (MiECC) and conventional extracorporeal circulation (CECC) during isolated surgical aortic valve replacement (SAVR), we conducted a randomized trial in patients undergoing primary elective SAVR at a tertiary referral hospital. The primary outcome was the procedural phase-related rate of high-intensity transient signals (HITS) on transcranial Doppler ultrasound. HITS rate was used as a surrogate of cerebral microembolism in pre-defined procedural phases in SAVR using MiECC or CECC with (+F) or without (-F) an oxygenator with integrated arterial filter. Forty-eight patients were randomized in a 1:1 ratio to MiECC or CECC. Due to intraprocedural Doppler signal loss (n = 3), 45 patients were included in final analysis. MiECC perfusion regimen showed a significantly increased HITS rate compared to CECC (by a factor of 1.75; 95% confidence interval, 1.19-2.56). This was due to different HITS rates in procedural phases from aortic cross-clamping until declamping [phase 4] (P = 0.01), and from aortic declamping until stop of extracorporeal perfusion [phase 5] (P = 0.05). Post hoc analysis revealed that MiECC-F generated a higher HITS rate than CECC+F (P = 0.005), CECC-F (P = 0.05) in phase 4, and CECC-F (P = 0.03) in phase 5, respectively. In open-heart surgery, MiECC is not superior to CECC with regard to gaseous cerebral microembolism. When using MiECC for SAVR, the use of oxygenators with integrated arterial line filter appears highly advisable. Only with this precaution, MiECC confers a cerebral microembolic load comparable to CECC during this type of open heart surgery.
Resumo:
Background: We aimed to assess the outcomes including the effect on quality of life (QoL) of a group of patients having a minimally invasive esophagectomy (MIE). Methods: Patients with esophageal cancer were offered MIE over a 22-month period. Data on outcomes were collected prospectively, including formal quality-of-assessments. Results: There were 25 patients offered MIE. Two patients were converted to a laparotomy to improve the lymphadenectomy. There were no deaths. Respiratory problems (pneumonia, 28%) were the most common in the 64% of patients who had a complication. The median blood loss was 300 ml, time of surgery 330 min, and time to discharge 11 days. There was a decrease in the measured QoL both in general and specifically for the esophageal patients, taking 18-24 months to return to baseline. Conclusion: MIE was performed with morbidity similar to other approaches. There were no clear benefits shown in this group of patients with respect to postoperative recovery or short- to medium-term QoL.
Resumo:
Background: Medial UKA performed in England and Wales represents 7 to 11% of all knee arthroplasty procedures, and is most commonly performed using mobile-bearing designs. Fixed bearing eliminates the risk of bearing dislocation, however some studies have shown higher revision rates for all-polyethylene tibial components compared to those that utilize metal-backed implants. The aim of the study is to analyse survivorship and maximum 8-year clinical outcome of medial fixed bearing, Uniglide unicompartmental knee arthroplasty performed using an all-polyethylene tibial component with a minimal invasive approach. Methods: Between 2002 and 2009, 270 medial fixed UKAs were performed in our unit. Patients were reviewed pre-operatively, 5 and 8 years post-operatively. Clinical and radiographic reviews were carried out. Patients’ outcome scores (Oxford, WOMAC and American Knee Score) were documented in our database and analysed. Results: Survival and clinical outcome data of 236 knees with a mean 7.3 years follow-up are reported. Every patient with less than 4.93 years follow-up underwent a revision. The patients’ average age at the time of surgery was 69.5 years. The American Knee Society Pain and Function scores, the Oxford Knee Score and the WOMAC score all improved significantly. The 5 years survival rate was 94.1% with implant revision surgery as an end point. The estimated 10 years survival rate is 91.3%. 14 patients were revised before the 5 year follow-up. Conclusion: Fixed bearing Uniglide UKA with an all-polyethylene tibial component is a valuable tool in the management of a medial compartment osteoarthritis, affording good short term survivorship.
Resumo:
BACKGROUND: Treatment of proximal humerus fractures in elderly patients is challenging because of reduced bone quality. We determined the in vitro characteristics of a new implant developed to target the remaining bone stock, and compared it with an implant in clinical use. METHODS: Following osteotomy, left and right humeral pairs from cadavers were treated with either the Button-Fix or the Humerusblock fixation system. Implant stiffness was determined for three clinically relevant cases of load: axial compression, torsion, and varus bending. In addition, a cyclic varus-bending test was performed. RESULTS: We found higher stiffness values for the humeri treated with the ButtonFix system--with almost a doubling of the compression, torsion, and bending stiffness values. Under dynamic loading, the ButtonFix system had superior stiffness and less K-wire migration compared to the Humerusblock system. INTERPRETATION: When compared to the Humerusblock design, the ButtonFix system showed superior biomechanical properties, both static and dynamic. It offers a minimally invasive alternative for the treatment of proximal humerus fractures.
Resumo:
Objectives: We compared post-operative analgesic requirements between women with early stage endometrial cancer treated by total abdominal hysterectomy (TAH) or total laparoscopic hysterectomy (TLH). Methods: 760 patients with apparent stage I endometrial cancer were treated in the international, multicentre, prospective randomised trial (LACE) by TAH (n=353) or TLH (n=407) (2005-2010). Epidural, opioid and non-opioid analgesic requirements were collected until ten months after surgery. Results: Baseline demographics and analgesic use were comparable between treatment arms. TAH patients were more likely to receive epidural analgesia than TLH patients (33% vs 0.5%, p<0.001) during the early postoperative phase. Although opioid use was comparable in the TAH vs TLH groups during postoperative 0-2 days (99.7% vs 98.5%, p 0.09), a significantly higher proportion of TAH patients required opioids 3-5 days (70% vs 22%, p<0.0001), 6-14 days (35% vs 15%, p<0.0001), and 15-60 days (15% vs 9%, p 0.02) post-surgery. Mean pain scores were significantly higher in the TAH versus TLH group one (2.48 vs 1.62, p<0.0001) and four weeks (0.89 vs 0.63, p 0.01) following surgery. Conclusion: Treatment of early stage endometrial cancer with TLH is associated with less frequent use of epidural, lower post-operative opioid requirements and better pain scores than TAH.
Resumo:
Background: The emerging field of microneedle-based minimally invasive patient monitoring and diagnosis is reviewed. Microneedle arrays consist of rows of micron-scale projections attached to a solid support. They have been widely investigated for transdermal drug and vaccine delivery applications since the late 1990s. However, researchers and clinicians have recently realized the great potential of microneedles for extraction of skin interstitial fluid and, less commonly, blood, for enhanced monitoring of patient health.
Methods: We reviewed the journal and patent literature, and summarized the findings and provided technical insights and critical analysis.
Results: We describe the basic concepts in detail and extensively review the work performed to date.
Conclusions: It is our view that microneedles will have an important role to play in clinical management of patients and will ultimately improve therapeutic outcomes for people worldwide.
Minimal intervention dentistry and older patients part 2: minimally invasive operative interventions
Resumo:
As described in the first paper of this two part series, the expansion of our older population and the concomitant reduction in levels of edentulism will result in an increase in the number of patients presenting in general practice with complex restorative challenges. The application of the concepts of minimal intervention dentistry and minimally invasive operative techniques may offer a powerful armamentarium to the general dentist to provide ethical and conservative treatment to older patients.
Clinical Relevance: When it is unavoidable, operative intervention should be as minimally invasive as practicable in older patients to preserve the longevity of their natural dentition.
Resumo:
OBJECTIVES: The aim of this study was to investigate if a minimally invasive oral health package with the use of atraumatic restorative treatment (ART) or a conventional restorative technique (CT) would result in any perceived benefit from the patients' perspective and if there would be any difference between the two treatment groups.
MATERIALS AND METHODS: In this randomised clinical trial, 99 independently living older adults (65-90 years) with carious lesions were randomly allocated to receive either ART or conventional restorations using minimally invasive/intervention dentistry (MID) principles. Patients completed an Oral Health Impact Profile (OHIP)-14 questionnaire before and 2 months after treatment. They were also asked to complete a global transition question about their oral health after treatment.
RESULTS: At baseline, the mean OHIP-14 scores recorded were 7.34 (ART) and 7.44 (CT). Two months after treatment intervention, 90 patients answered the OHIP-14 and the mean scores were 7.23 (not significant (n.s.)) and 10.38 (n.s.) for the ART and CT groups, respectively. Overall, 75.5 % of patients stated that their oral health was better compared to the beginning of treatment.
CONCLUSIONS: Although not shown by the OHIP-14, patients perceived an improvement in their overall oral status after treatment, as demonstrated by the global transition ratings in both groups.
CLINICAL RELEVANCE: Dental treatment using minimally invasive techniques might be a good alternative to treat older individuals, and it can improve their oral health both objectively and subjectively.
Resumo:
We describe, for the first time, hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of lithium in vitro and in vivo. MN arrays, prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) and crosslinked by poly(ethyleneglycol), imbibed interstitial fluid (ISF) upon skin insertion. Such MN were always removed intact. In vitro, mean detected lithium concentrations showed no significant difference following 30 min MN application to excised neonatal porcine skin for lithium citrate concentrations of 0.9 and 2 mmol/l. However, after 1 h application, the mean lithium concentrations extracted were significantly different, being appropriately concentration-dependent. In vivo, rats were orally dosed with lithium citrate equivalent to 15 mg/kg and 30 mg/kg lithium carbonate, respectively. MN arrays were applied 1 h after dosing and removed 1 h later. The two groups, having received different doses, showed no significant difference between lithium concentrations in serum or MN. However, the higher dosed rats demonstrated a lithium concentration extracted from MN arrays equivalent to a mean increase of 22.5 % compared to rats which received the lower dose. Hydrogel-forming MN clearly have potential as a minimally-invasive tool for lithium monitoring in out-patient settings. We will now focus on correlation of serum and MN lithium concentrations.
Resumo:
Réalisé sous la co-direction des Drs Denis Bouchard et Michel Pellerin