899 resultados para Replacement mortar
Resumo:
3rd Historic Mortars Conference, 11-14 September 2013, Glasgow, Scotland
Resumo:
Construction and Building Materials 49 (2013), 315-327
Resumo:
Materials Science Forum Vols. 730-732 (2013) pp 617-622
Resumo:
Construction and Building Materials 54 (2014) 378–384
Resumo:
2nd Historic Mortars Conference - HMC 2010 and RILEM TC 203-RHM Final Workshop, Prague, September 2010
Resumo:
Earthen plastering mortars are becoming recognized as highly eco-efficient. The assessment of their technical properties needs to be standardized but only the German standard DIN 18947 exists for the moment. An extended experimental campaign was developed in order to assess multiple properties of a ready-mixed earth plastering mortar and also to increase scientific knowledge of the influence of test procedures on those properties. The experimental campaign showed that some aspects related to the equipment, type of samples and sample preparation can be very important, while others seemed to have less influence on the results and the classification of mortars. It also showed that some complementary tests can easily be performed and considered together with the standardized ones, while others may need to be improved. The plaster satisfied the requirements of the existing German standard but, most importantly, it seemed adequate for application as rehabilitation plaster on historic and modern masonry buildings. Apart from their aesthetic aspect, the contribution of earthen plasters to eco-efficiency and particularly to hygrometric indoor comfort should be highlighted.
Resumo:
INTRODUCTION: In the postmenopausal period, an average of 25% of women will present symptomatic ovarian failure requiring hormonal replacement therapy. Estrogen can relieve vasomotor symptoms. Hormonal replacement therapy is generally not recommended for breast cancer patients due to the potential risk of tumor recurrence. To answer the questions about the safety of hormonal replacement therapy in this subgroup of women, it is necessary to establish the acceptance of treatment. METHODS: Between September 1998 and February 2001, a cohort of 216 breast cancer patients were asked to complete a questionnaire. All patients had completed their treatment and were informed about survival rates after breast cancer and hormonal replacement therapy. RESULTS: Among the 216 patients, 134 (62%) would refuse hormonal replacement therapy. A hundred patients were afraid of relapse (74.6%). Adjuvant tamoxifen therapy was the only statistically significant variable (70.3% versus 29.7% p=0.003). Understanding clinical stage (p= 0.045) and type of medical assistance (private versus public , p=0.033) also seemed to influence the decision. Early stage disease (p= 0.22), type of surgical procedure (radical versus conservative, p=0.67), adjuvant chemotherapy (p=0.082) or marital status (p=0.98 ) were not statistically significant in decision making. Several patients submitted to adjuvant chemotherapy (41.6%) would accept hormonal replacement therapy under medical supervision, as did most of advanced clinical stage patients (58.3%; p=0.022). CONCLUSION: There is a high level of rejection for hormonal replacement therapy among breast cancer patients when current data on tumor cure rates, and potential risks of estrogen use is available. Adverse effects of tamoxifen in the adjuvant setting may be the reason for refusal of hormonal replacement therapy .
Resumo:
The use of testosterone in older men, known as male hormonal replacement therapy or androgen replacement therapy, has become of increasing interest to both the medical and lay communities over the past decade. Even though the knowledge of the potential benefits and risks of male Androgen Replacement Therapy has increased dramatically, there is still much that needs to be determined. Although there are a number of potential benefits of male Androgen Replacement Therapy and data concerning clinical effects of such replacement have accumulated, as yet there have not been any large multicenter randomized controlled trials of this therapy. It is the purpose of this article to review what is currently known about the possible risks and benefits of male Androgen Replacement Therapy by discussing the clinical trials to date.
Resumo:
Premature degradation of ordinary Portland cement (OPC) concrete infrastructures is a current and serious problem with overwhelming costs amounting to several trillion dollars. The use of concrete surface treatments with waterproofing materials to prevent the access of aggressive substances is an important way of enhancing concrete durability. The most common surface treatments use polymeric resins based on epoxy, silicone (siloxane), acrylics, polyurethanes or polymethacrylate. However, epoxy resins have low resistance to ultraviolet radiation while polyurethanes are sensitive to high alkalinity environments. Geopolymers constitute a group of materials with high resistance to chemical attack that could also be used for coating of concrete infrastructures exposed to harsh chemical environments. This article presents results of an experimental investigation on the resistance to chemical attack (by sulfuric and nitric acid) of several materials: OPC concrete, high performance concrete (HPC), epoxy resin, acrylic painting and a fly ash based geopolymeric mortar. Three types of acids, each with high concentrations of 10%, 20% and 30%, were used to simulate long term degradation by chemical attack. The results show that the epoxy resin had the best resistance to chemical attack, irrespective of the acid type and acid concentration.
Resumo:
Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.
Resumo:
Nowadays, the concrete production sector is challenged by attempts to minimize the usage of raw materials and energy consumption, as well as by environmental concerns. Therefore, it is necessary to choose better options, e.g. new technologies or materials with improved life-cycle performance. One solution for using resources in an efficient manner is to close the materials' loop through the recycling of materials that result either from the end-of-life of products or from being the by-product of an industrial process. It is well known that the production of Portland cement, one of the materials most used in the construction sector, has a significant contribution to the environmental impacts, mainly related with carbon dioxide emission. Therefore, the study and utilization of by-products or wastes usable as cement replacement in concrete can supply more sustainable options, provided that these type of concrete produced has same durability and equivalent quality properties as standard concrete. This work studied the environmental benefits of incorporating different percentages of two types of fly ashes that can be used in concrete as cement replacement. These ashes are waste products of power and heat production sectors using coal or biomass as fuels. The results showed that both ashes provide a benefit for the concrete production both in terms of environmental impact minimization and a better environmental performance through an increase in cement replacement. It is possible to verify that the incorporation of fly ashes is a sustainable option for cement substitution and a possible path to improve the environmental performance of the concrete industry.
Resumo:
The behaviour of masonry elements under in-plane and out-of-plane loads can be improved through the application of strengthening systems based on reinforcing overlays. After strengthening, the transition region between the original substrate and the strengthening layer is especially stressed, and premature failure of the strengthened masonry is reached if insufficient interfacial capacity is assured. Therefore, the assessment of the mechanical behaviour of the interface is critical to the development of the masonry strengthening system based on the application of strengthening overlays. In this research a method for the characterization of the interface behaviour between two different materials, a polypropylene fibre reinforced mortar (PFRM) and a ceramic brick used for masonry construction is presented. Direct shear tests were carried out in couplet specimens. Due to the orthotropic nature of the bricks surface, the shear load was applied along three different directions in order to perform an overall estimation of the interface behaviour. The peak and residual shear stresses, as well as the failure modes, were obtained at different levels of the normal stress. Based on these experimental results constitutive laws were assessed for the simulation of the interface mechanical behaviour based on the Mohr and Mohr-Coulomb failure criteria.
Resumo:
Artigo completo publicado na revista "Journal of The Electrochemical Society" 161:6 (2014) C349-C362 e disponível no RepositóriUM em: http://hdl.handle.net/1822/33784
Resumo:
Artigo completo publicado na revista "Journal of The Electrochemical Society" 161:6 (2014) C349-C362 e disponível no RepositóriUM em: http://hdl.handle.net/1822/33784. Errata disponível no RepositóriUM em: http://hdl.handle.net/1822/40064. (Publisher’s note: An erratum that addressed the errors in Figure 9 was originally published on Dec. 10, 2014, however the graphs in that erratum were not correct.)
Resumo:
This article presents results of an experimental investigation on the resistance to chemical attack (with sulphuric, hydrochloric and nitric acid) of several materials: OPC concrete, high-performance concrete, epoxy resin, acrylic painting and a fly ash-based geopolymeric mortar). Three types of acids with three high concentrations (10, 20 and 30%) were used to simulate long-term degradation. A cost analysis was also performed. The results show that the epoxy resin has the best resistance to chemical attack independently of the acid type and the acid concentration. However, the cost analysis shows that the epoxy resin-based solution is the least cost-efficient solution being 70% above the cost efficiency of the fly ash-based geopolymeric mortar.