969 resultados para Repeated measurements
Resumo:
We have considered a Bayesian approach for the nonlinear regression model by replacing the normal distribution on the error term by some skewed distributions, which account for both skewness and heavy tails or skewness alone. The type of data considered in this paper concerns repeated measurements taken in time on a set of individuals. Such multiple observations on the same individual generally produce serially correlated outcomes. Thus, additionally, our model does allow for a correlation between observations made from the same individual. We have illustrated the procedure using a data set to study the growth curves of a clinic measurement of a group of pregnant women from an obstetrics clinic in Santiago, Chile. Parameter estimation and prediction were carried out using appropriate posterior simulation schemes based in Markov Chain Monte Carlo methods. Besides the deviance information criterion (DIC) and the conditional predictive ordinate (CPO), we suggest the use of proper scoring rules based on the posterior predictive distribution for comparing models. For our data set, all these criteria chose the skew-t model as the best model for the errors. These DIC and CPO criteria are also validated, for the model proposed here, through a simulation study. As a conclusion of this study, the DIC criterion is not trustful for this kind of complex model.
Resumo:
Objective To investigate if a home environment test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression. Background Seventy-seven patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study at 10 clinics in Sweden and Norway; 40 of them were treated with levodopa-carbidopa intestinal gel (LCIG) and 37 patients were candidates for switching from oral PD treatment to LCIG. They utilized a mobile device test battery, consisting of self-assessments of symptoms and objective measures of motor function through a set of fine motor tests (tapping and spiral drawings), in their homes. Both the LCIG-naïve and LCIG-non-naïve patients used the test battery four times per day during week-long test periods. Methods Assessments The LCIG-naïve patients used the test battery at baseline (before LCIG), month 0 (first visit; at least 3 months after intraduodenal LCIG), and thereafter quarterly for the first year and biannually for the second and third years. The LCIG-non-naïve patients used the test battery from the first visit, i.e. month 0. Out of the 77 patients, only 65 utilized the test battery; 35 were LCIG-non-naïve and 30 LCIG-naïve. In 20 of the LCIG-naïve patients, assessments with the test battery were available during oral treatment and at least one test period after having started infusion treatment. Three LCIG-naïve patients did not use the test battery at baseline but had at least one test period of assessments thereafter. Hence, n=23 in the LCIG-naïve group. In total, symptom assessments in the full sample (including both patient groups) were collected during 379 test periods and 10079 test occasions. For 369 of these test periods, clinical assessments including UPDRS and PDQ-39 were performed in afternoons at the start of the test periods. The repeated measurements of the test battery were processed and summarized into scores representing patients’ symptom severities over a test period, using statistical methods. Six conceptual dimensions were defined; four subjectively-reported: ‘walking’, ‘satisfied’, ‘dyskinesia’, and ‘off’ and two objectively-measured: ‘tapping’ and ‘spiral’. In addition, an ‘overall test score’ (OTS) was defined to represent the global health condition of the patient during a test period. Statistical methods Change in the test battery scores over time, that is at baseline and follow-up test periods, was assessed with linear mixed-effects models with patient ID as a random effect and test period as a fixed effect of interest. The within-patient variability of OTS was assessed using intra-class correlation coefficient (ICC), for the two patient groups. Correlations between clinical rating scores and test battery scores were assessed using Spearman’s rank correlations (rho). Results In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. However, there were no significant changes in mean OTS scores of LCIG-non-naïve patients, except for worse mean OTS at month 36 (p<0.01, n=16). The mean scores of all subjectively-reported dimensions improved significantly throughout the course of the study, except ‘walking’ at month 36 (p=0.41, n=4). However, there were no significant differences in mean scores of objectively-measured dimensions between baseline and other test periods, except improved ‘tapping’ at month 6 and month 36, and ‘spiral’ at month 3 (p<0.05). The LCIG-naïve patients had a higher within-subject variability in their OTS scores (ICC=0.67) compared to LCIG-non-naïve patients (ICC=0.71). The OTS correlated adequately with total UPDRS (rho=0.59) and total PDQ-39 (rho=0.59). Conclusions In this 3-year follow-up study of advanced PD patients treated with LCIG we found that it is possible to monitor PD progression over time using a home environment test battery. The significant improvements in the mean OTS scores indicate that the test battery is able to measure functional improvement with LCIG sustained over at least 24 months.
Resumo:
The aim of this study was to investigate if a telemetry test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression in patients with fluctuations. Sixty-five patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study; 35 treated with levodopa-carbidopa intestinal gel (LCIG) and 30 were candidates for switching from oral PD treatment to LCIG. They utilized a test battery, consisting of self-assessments of symptoms and fine motor tests (tapping and spiral drawings), four times per day in their homes during week-long test periods. The repeated measurements were summarized into an overall test score (OTS) to represent the global condition of the patient during a test period. Clinical assessments included ratings on Unified PD Rating Scale (UPDRS) and 39-item PD Questionnaire (PDQ-39) scales. In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. In LCIG-non-naïve patients, there were no significant changes in mean OTS until month 36. The OTS correlated adequately with total UPDRS (rho = 0.59) and total PDQ-39 (0.59). Responsiveness measured as effect size was 0.696 and 0.536 for OTS and UPDRS respectively. The trends of the test scores were similar to the trends of clinical rating scores but dropout rate was high. Correlations between OTS and clinical rating scales were adequate indicating that the test battery contains important elements of the information of well-established scales. The responsiveness and reproducibility were better for OTS than for total UPDRS.
Resumo:
ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim To evaluate ex vivo effectiveness of the three formulations of bleaching materials for intracoronal bleaching of root filled teeth using the walking bleach technique.Methodology Extracted premolar teeth were stained artificially with human blood. After biomechanical preparation, the root canals were filled and a 3-mm thick intermediate base of zinc phosphate cement was placed at the level of the cementoenamel junction. The teeth were divided into four groups (n = 12): C (control, without bleaching material), A1 (sodium perborate + distilled water), A2 (sodium perborate + 10% carbamide peroxide) and A3 (sodium perborate + 35% carbamide peroxide). The bleaching materials were changed at 7 and 14 days. Evaluation of shade was undertaken with aid of the VITA Easyshade (TM) (Delta E*ab) and was performed after tooth staining and at 7, 14 and 21 days after bleaching, based on the CIELAB system. Data were analysed by ANOVA for repeated measurements, Tukey and Dunnett tests (alpha = 0.05).Results The Tukey test revealed that group A1 (10.58 +/- 4.83 Delta E*ab) was statistically different from the others (A2, 19.57 +/- 4.72 Delta E*ab and A3, 17.58 +/- 3.33 Delta E*ab), which were not different from each other. At 7 days: A1 was significantly different from A2; at 14 and 21 days: A2 and A3 were significantly better than A1; the Dunnett test revealed that the control group was different from A1, A2 and A3 at all periods (P < 0.05).Conclusion Sodium perborate associated with both 10% and 35% carbamide peroxide was more effective than when associated with distilled water.
Resumo:
Statement of problem. Prosthetic restorations that fit poorly may affect periodontal health and occlusion. Studies that have evaluated the accuracy of fit of ceramic restorations before and after cementation assessed primarily intracoronal restorations.Purpose. This in vitro study evaluated the effect of different finish lines, ceramic manufacturing techniques, and luting agents on the vertical discrepancy of ceramic copings.Material and methods. Two stainless steel molars were prepared for complete crowns with 2 different finish lines (heavy chamfer and rounded shoulder); each molar was duplicated to fabricate 90 copings. A total of 180 copings generated 18 groups (n=10 for each finish line-coping material-luting agent combination). Luting agents tested included zinc phosphate, resin-modified glass ionomer (Fuji Plus), and resin composite cements (Panavia F). A metal frame was developed on which to screw the stainless steel model and a ceramic coping; the distance (mum) between 2 predetermined points was measured before and after cementation by a profile projector under a torquing force. A 4-way ANOVA with repeated measurements was performed to assess the influence of each factor in the vertical marginal discrepancy: 3 between-coping factors (finish line-coping material-luting agent) and 1 within-coping factor (before and after cementation) (alpha=.05).Results. Procera copings presented the lowest mean values (P<.05) of vertical marginal discrepancy before and after cementation (25/44 mum) when compared to Empress 2 (68/110 mum) and InCeram Alumina copings (57/117 mum), regardless of any combinations among all finish lines and luting agents tested.Conclusion. Considering each factor separately, the ceramic manufacturing technique appeared to be the most important factor tested for the definitive vertical discrepancy of all-ceramic copings, with lower mean values for Procera copings.
Resumo:
The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.
Comparação entre o desempenho motor de hommes e mulheres em séries múltiplas de exercícios com pesos
Resumo:
The magnitude of men and women's neuromuscular, metabolic, and morphologic responses seems to be quite different even when both are submitted to exercise protocols using similar weight exercises protocols. However, differences in the motor performance between men and women have been predominantly reported in protocols based on isometric and isokinetic contractions. Thus, this study aimed to analyze men and women's behavior during multiple sets of weight exercises achieving the exhaustion, and later verifying possible differences as to the physical performance between genders using weights with similar intensity. For this, 83 subjects (50 men, and 33 women), 48 hours after being submitted to 1-RM tests in bench press, squat and arm curl performed a protocol composed by four sets at 1-RM 80% up to achieving the exhaustion in each of three exercises to evaluate the endurance ability to the fatigue in different muscular groups. It was used the ANOVA and ANCOVA for repeated measurements, followed by the Tukey's post hoc test, where P < 0.05 to the data treatment. It was verified a significant fall in the performance both in men and in women since the first up to the fourth sets of every exercise investigated (P < 0.01). Although the fatigue magnitude was higher in men in all the three exercises, the effect on the gender was only identified in the arm curl exercise (P < 0.01). The results of this study indicated that men and women presented quite different behavior in multiple sets of weight exercises, and women presented a more stable performance and a higher endurance ability to the fatigue in the arm curl as well.
Resumo:
Purpose: To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and rive men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals.
Resumo:
This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.
Resumo:
Purpose. We quantified the main sequence of spontaneous blinks in normal subjects and Graves' disease patients with upper eyelid retraction using a nonlinear and two linear models, and examined the variability of the main sequence estimated with standard linear regression for 10-minute periods of time. Methods. A total of 20 normal subjects and 12 patients had their spontaneous blinking measured with the magnetic search coil technique when watching a video during one hour. The main sequence was estimated with a power-law function, and with standard and trough the origin linear regressions. Repeated measurements ANOVA was used to test the mean sequence stability of 10-minute bins measured with standard linear regression. Results. In 95% of the sample the correlation coefficients of the main sequence ranged from 0.60 to 0.94. Homoscedasticity of the peak velocity was not verified in 20% of the subjects and 25% of the patients. The power-law function provided the best main sequence fitting for subjects and patients. The mean sequence of 10-minute bins measured with standard linear regression did not differ from the one-hour period value. For the entire period of observation and the slope obtained by standard linear regression, the main sequence of the patients was reduced significantly compared to the normal subjects. Conclusions. Standard linear regression is a valid and stable approximation for estimating the main sequence of spontaneous blinking. However, the basic assumptions of the linear regression model should be examined on an individual basis. The maximum velocity of large blinks is slower in Graves' disease patients than in normal subjects. © 2013 The Association for Research in Vision and Ophthalmology, Inc.