988 resultados para Repeated loading tests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P < 0.05) relationships occurred between muscle-to-bone ratio and both CMJs height (r ranging from 0.56 to 0.69) as well as with all RSA-related variables (r < -0.53 for sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P < 0.01 and r = 0.55, P < 0.05, respectively) but not with total time (TT, r = 0.44 and 0.33, P > 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to determine adjustments in spring-mass model characteristics, plantar loading and foot mobility induced by an exhaustive run. DESIGN: Within-participants repeated measures. METHODS: Eleven highly-trained adolescent middle-distance runners ran to exhaustion on a treadmill at a constant velocity corresponding to 95% of velocity associated with VO₂max (17.8 ± 1.4 kmh(-1), time to exhaustion=8.8 ± 3.4 min). Contact time obtained from plantar pressure sensors was used to estimate spring-mass model characteristics, which were recorded (during 30 s) 1 min after the start and prior to exhaustion using pressure insoles. Foot mobility magnitude (a composite measure of vertical and medial-lateral mobility of the midfoot) was measured before and after the run. RESULTS: Mean contact area (foot to ground), contact time, peak vertical ground reaction force, centre of mass vertical displacement and leg compression increased significantly with fatigue, while flight time, leg stiffness and mean pressure decreased. Leg stiffness decreased because leg compression increased to a larger extent than peak vertical ground reaction forces. Step length, step frequency and foot mobility magnitude did not change at exhaustion. CONCLUSIONS: The stride pattern of adolescents when running on a treadmill at high constant velocity deteriorates near exhaustion, as evidenced by impaired leg-spring behaviour (leg stiffness) and altered plantar loading.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We explored the washout period of creatine (Cr) after repeated ingestions of high doses of exogenous Cr. Ten athletes ingested daily, in a randomized double-blind study design, 30 g of exoge- nous Cr (n = 5, Cr-group) or a placebo (n = 5, Pl-group). Serum and urine samples were collected 1) before supplementation (BEFO- RE), 2) after one week Cr supplementation (AFTER), and 3) one week later without supplementation (LATER). The Cr and crea- tinine (Crn) concentrations in serum (sCr, sCrn) and in multiple spots urine (uCr, uCrn) were measured. We observed a significant rise (p < 0.01) in sCr, uCr and sCrn between BEFORE and AFTER supplementation in Cr-group, as well as a significant difference between Cr-group and Pl-group. Body weight increased signifi- cantly (+1.5 kg), but relative body fat (%fat) was unchanged. After the washout period in LATER Cr-group, sCr and uCr decreased to low residual values. No loss of body weight occurred during thisperiod. In contrast, sCrn and uCrn returned to baseline values. In conclusion, regular uptake of high doses of exogenous Cr affects both Cr and Crn concentrations in serum (sCr: 14 folds; sCrn: 1.2 folds) and urine (uCr: 140 folds; uCrn: 1.5 folds). An abuse of Cr is therefore mostly spilled over in urine. Surprise drug tests, such as doping controls, happening during the period of Cr supplementa- tion can reveal an important increase in Cr and Crn concentrations, although subjects stopped suddenly Cr loading. The discernible effect of Cr supplementation on these values disappeared within one week.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Expansion joints increase both the initial cost and the maintenance cost of bridges. Integral abutment bridges provide an attractive design alternative because expansion joints are eliminated from the bridge itself. However, the piles in these bridges are subjected to horizontal movement as the bridge expands and contracts during temperature changes. The objective of this research was to develop a method of designing piles for these conditions. Separate field tests simulating a pile and a bridge girder were conducted for three loading cases: (1) vertical load only, (2) horizontal displacement of pile head only, and (3) combined horizontal displacement of pile head with subsequent vertical load. Both tests (1) and (3) reached the same ultimate vertical load, that is, the horizontal displacement had no effect on the vertical load capacity. Several model tests were conducted in sand with a scale factor of about 1:10. Experimental results from both the field and model tests were used to develop the vertical and horizontal load-displacement properties of the soil. These properties were input into the finite element computer program Integral Abutment Bridge Two-Dimensional (IAB2D), which was developed under a previous research contract. Experimental and analytical results compared well for the test cases. Two alternative design methods, both based upon the American Association of State Highway and Transportation Officials (AASHTO) Specification, were developed. Alternative One is quite conservative relative to IAB2D results and does not permit plastic redistribution of forces. Alternative Two is also conservative when compared to IAB2D, but plastic redistribution is permitted. To use Alternative Two, the pile cross section must have sufficient inelastic rotation capacity before local buckling occurs. A design example for a friction pile and an end-bearing pile illustrates both alternatives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the results of the static and dynamic testing of a three-span continuous I-beam highway bridge. Live load stress frequency curves for selected points are shown, and the static and dynamic load distribution to the longitudinal composite beam members are given. The bridge has four traffic lanes with a roadway width of 48 ft. Six longitudinal continuous WF beams act compositely with the reinforced concrete slab to carry the live load. The beams have partial length cover plates at the piers. Previous research has indicated that beams with partial length cover plates have a very low fatigue strength. It was found in this research that the magnitude of the stresses due to actual highway loads were very much smaller than those computed from specification loading. Also, the larger stresses which were measured occurred a relatively small number of times. These data indicate that some requirements for reduced allowable stresses at the ends of cover plates are too conservative. The load distribution to the longitudinal beams was determined for static and moving loads and includes the effect of impact on the distribution. The effective composite section was found at various locations to evaluate the load distribution data. The composite action was in negative as well as positive moment regions. The load distribution data indicate that the lateral distribution of live load is consistent with the specifications, but that there is longitudinal distribution, and therefore the specifications are too conservative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite a low positive predictive value, diagnostic tests such as complete blood count (CBC) and C-reactive protein (CRP) are commonly used to evaluate whether infants with risk factors for early-onset neonatal sepsis (EOS) should be treated with antibiotics. We investigated the impact of implementing a protocol aiming at reducing the number of diagnostic tests in infants with risk factors for EOS in order to compare the diagnostic performance of repeated clinical examination with CBC and CRP measurement. The primary outcome was the time between birth and the first dose of antibiotics in infants treated for suspected EOS. Among the 11,503 infants born at ≥35 weeks during the study period, 222 were treated with antibiotics for suspected EOS. The proportion of infants receiving antibiotics for suspected EOS was 2.1% and 1.7% before and after the change of protocol (p = 0.09). Reduction of diagnostic tests was associated with earlier antibiotic treatment in infants treated for suspected EOS (hazard ratio 1.58; 95% confidence interval [CI] 1.20-2.07; p <0.001), and in infants with neonatal infection (hazard ratio 2.20; 95% CI 1.19-4.06; p = 0.01). There was no difference in the duration of hospital stay nor in the proportion of infants requiring respiratory or cardiovascular support before and after the change of protocol. Reduction of diagnostic tests such as CBC and CRP does not delay initiation of antibiotic treatment in infants with suspected EOS. The importance of clinical examination in infants with risk factors for EOS should be emphasised.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges crossing the river were scheduled for removal. Two of these were incorporated into a comprehensive test program to study the behavior of old pin-connected high-truss single-lane bridges. The test program consisted of ultimate load tests, service load tests and a supplementary test program. The results reported in this report cover the service load tests on the two bridges as well as the supplementary tests, both static and fatigue, of eyebar members removed from the two bridges. The field test results of the service loading are compared with theoretical results of the truss analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rectangular hollow section (RHS) members are components widely used in engineering applications because of their good-looking, good properties in engineering areas and inexpensive cost comparing to members with other sections. The increasing use of RHS in load bearing structures makes it necessary to analyze the fatigue behavior of the RHS members. In this thesis, concentration will be given to the fatigue behavior of the RHS members under variable amplitude pure torsional loading. For the RHS members, failure will normally occur in the corner region if the welded regions are under full penetration. This is because of the complicated stress components' distributions at the RHScorners, where all of three fracture mechanics modes will happen. Mode I is mainly caused by the residual stresses that caused by the manufacturing process. Modes II and III are caused by the applied torsional loading. Stress based Findleymodel is also used to analyze the stress components. Constant amplitude fatigue tests have been done as well as variable amplitude fatigue tests. The specimens under variable amplitude loading gave longer fatigue lives than those under constant amplitude loading. Results from tests show an S-N curvewith slope around 5.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Despite a low positive predictive value, diagnostic tests such as complete blood count (CBC) and C-reactive protein (CRP) are commonly used to evaluate whether infants with risk factors for early-onset neonatal sepsis (EOS) should be treated with antibiotics. STUDY DESIGN: We investigated the impact of imple- menting a protocol aiming at reducing the number of dia- gnostic tests in infants with risk factors for EOS in order to compare the diagnostic performance of repeated clinical examination with CBC and CRP measurement. The primary outcome was the time between birth and the first dose of antibiotics in infants treated for suspected EOS. RESULTS: Among the 11,503 infants born at 35 weeks during the study period, 222 were treated with antibiotics for suspected EOS. The proportion of infants receiving an- tibiotics for suspected EOS was 2.1% and 1.7% before and after the change of protocol (p = 0.09). Reduction of dia- gnostic tests was associated with earlier antibiotic treat- ment in infants treated for suspected EOS (hazard ratio 1.58; 95% confidence interval [CI] 1.20-2.07; p <0.001), and in infants with neonatal infection (hazard ratio 2.20; 95% CI 1.19-4.06; p = 0.01). There was no difference in the duration of hospital stay nor in the proportion of infants requiring respiratory or cardiovascular support before and after the change of protocol. CONCLUSION: Reduction of diagnostic tests such as CBC and CRP does not delay initiation of antibiotic treat- ment in infants with suspected EOS. The importance of clinical examination in infants with risk factors for EOS should be emphasised.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, finite element analyses and experimental tests are carried out in order to investigate the effect of loading type and symmetry on the fatigue strength of three different non-load carrying welded joints. The current codes and recommendations do not give explicit instructions how to consider degree of bending in loading and the effect of symmetry in the fatigue assessment of welded joints. The fatigue assessment is done by using effective notch stress method and linear elastic fracture mechanics. Transverse attachment and cover plate joints are analyzed by using 2D plane strain element models in FEMAP/NxNastran and Franc2D software and longitudinal gusset case is analyzed by using solid element models in Abaqus and Abaqus/XFEM software. By means of the evaluated effective notch stress range and stress intensity factor range, the nominal fatigue strength is assessed. Experimental tests consist of the fatigue tests of transverse attachment joints with total amount of 12 specimens. In the tests, the effect of both loading type and symmetry on the fatigue strength is studied. Finite element analyses showed that the fatigue strength of asymmetric joint is higher in tensile loading and the fatigue strength of symmetric joint is higher in bending loading in terms of nominal and hot spot stress methods. Linear elastic fracture mechanics indicated that bending reduces stress intensity factors when the crack size is relatively large since the normal stress decreases at the crack tip due to the stress gradient. Under tensile loading, experimental tests corresponded with finite element analyzes. Still, the fatigue tested joints subjected to bending showed the bending increased the fatigue strength of non-load carrying welded joints and the fatigue test results did not fully agree with the fatigue assessment. According to the results, it can be concluded that in tensile loading, the symmetry of joint distinctly affects on the fatigue strength. The fatigue life assessment of bending loaded joints is challenging since it depends on whether the crack initiation or propagation is predominant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the relative effectiveness of two computerized remedial reading programs in improving the reading word recognition, rate, and comprehension of adolescent readers demonstrating significant and longstanding reading difficulties. One of the programs involved was Autoskill Component Reading Subskills Program, which provides instruction in isolated letters, syllables, and words, to a point of rapid automatic responding. This program also incorporates reading disability subtypes in its approach. The second program, Read It Again. Sam, delivers a repeated reading strategy. The study also examined the feasibility of using peer tutors in association with these two programs. Grade 9 students at a secondary vocational school who satisfied specific criteria with respect to cognitive and reading ability participated. Eighteen students were randomly assigned to three matched groups, based on prior screening on a battery of reading achievement tests. Two I I groups received training with one of the computer programs; the third group acted as a control and received the remedial reading program offered within the regular classroom. The groups met daily with a trained tutor for approximately 35 minutes, and were required to accumulate twenty hours of instruction. At the conclusion of the program, the pretest battery was repeated. No significant differences were found in the treatment effects of the two computer groups. Each of the two treatment groups was able to effect significantly improved reading word recognition and rate, relative to the control group. Comprehension gains were modest. The treatment groups demonstrated a significant gain, relative to the control group, on one of the three comprehension measures; only trends toward a gain were noted on the remaining two measures. The tutoring partnership appeared to be a viable alternative for the teacher seeking to provide individualized computerized remedial programs for adolescent unskilled readers. Both programs took advantage of computer technology in providing individualized drill and practice, instant feedback, and ongoing recordkeeping. With limited cautions, each of these programs was considered effective and practical for use with adolescent unskilled readers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les simulations et figures ont été réalisées avec le logiciel R.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La aplicación de materiales compuestos de matriz polimérica reforzados mediante fibras largas (FRP, Fiber Reinforced Plastic), está en gradual crecimiento debido a las buenas propiedades específicas y a la flexibilidad en el diseño. Uno de los mayores consumidores es la industria aeroespacial, dado que la aplicación de estos materiales tiene claros beneficios económicos y medioambientales. Cuando los materiales compuestos se aplican en componentes estructurales, se inicia un programa de diseño donde se combinan ensayos reales y técnicas de análisis. El desarrollo de herramientas de análisis fiables que permiten comprender el comportamiento mecánico de la estructura, así como reemplazar muchos, pero no todos, los ensayos reales, es de claro interés. Susceptibilidad al daño debido a cargas de impacto fuera del plano es uno de los aspectos de más importancia que se tienen en cuenta durante el proceso de diseño de estructuras de material compuesto. La falta de conocimiento de los efectos del impacto en estas estructuras es un factor que limita el uso de estos materiales. Por lo tanto, el desarrollo de modelos de ensayo virtual mecánico para analizar la resistencia a impacto de una estructura es de gran interés, pero aún más, la predicción de la resistencia residual después del impacto. En este sentido, el presente trabajo abarca un amplio rango de análisis de eventos de impacto a baja velocidad en placas laminadas de material compuesto, monolíticas, planas, rectangulares, y con secuencias de apilamiento convencionales. Teniendo en cuenta que el principal objetivo del presente trabajo es la predicción de la resistencia residual a compresión, diferentes tareas se llevan a cabo para favorecer el adecuado análisis del problema. Los temas que se desarrollan son: la descripción analítica del impacto, el diseño y la realización de un plan de ensayos experimentales, la formulación e implementación de modelos constitutivos para la descripción del comportamiento del material, y el desarrollo de ensayos virtuales basados en modelos de elementos finitos en los que se usan los modelos constitutivos implementados.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resistive respiratory loading is an established stimulus for the induction of experimental dyspnoea. In comparison to unloaded breathing, resistive loaded breathing alters end-tidal CO2 (PETCO2), which has independent physiological effects (e.g. upon cerebral blood flow). We investigated the subjective effects of resistive loaded breathing with stabilized PETCO2 (isocapnia) during manual control of inspired gases on varying baseline levels of mild hypercapnia increased PETCO2). Furthermore, to investigate whether perceptual habituation to dyspnoea stimuli occurs, the study was repeated over four experimental sessions. Isocapnic hypercapnia did not affect dyspnoea unpleasantness during resistive loading. A post hoc analysis revealed a small increase of respiratory unpleasantness during unloaded breathing at +0.6 kPa, the level that reliably induced isocapnia. We didnot observe perceptual habituation over the four sessions. We conclude that isocapnic respiratory loading allows stable induction of respiratory unpleasantness, making it a good stimulus for multi-session studies of dyspnoea.