957 resultados para Removable partial prosthesis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design of the ParalAB device facilitates transfer of the path of insertion from the diagnostic cast to the mouth quickly and efficiently.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Even nowadays there is in Brasil a large number of edentulous and a precarious financial condition of most of the population. In addition, World Health Organization aims for oral health, which consists on the maintenance of a natural dentition, functional and aesthetic composed of at least 20 teeth, without need of prosthetic intervention throughout life. From this and considering the lack of researches about the permanence of edentulous spaces in the oral cavity, and also avoiding overtreatment, this research has been proposed. Thus, the aim was to evaluate the effect of different lengths of the shortened lower dental arch in the presence or absence of a removable partial denture (RPD) on masticatory function, quality of life and occurrence of temporomandibular dysfunction. To achieve this goal, we compared the masticatory efficiency (colorimetric test), the oral comfort through the analysis of the impact of oral health in quality of life (OHIP-14), the presence of temporomandibular dysfunction (RDC/TMD) and the general quality of life (WHOQOL) of patients with shortened dental arches (SDA) (n=60), which is an arch with a reduction of teeth starting posteriorly, and patients with complete dental arch (Complete DA) (n = 34). The group of patients whit SDA was divided among PPR wears (PPD + SDA) (n = 17) and non-wears (n = 43). The population of this study consisted on patients who received or looked for treatment at the clinics of the Department of Dentistry of UFRN, from clinical analysis and records. The sample was chosen by convenience. For statistical analysis, it was a database in SPSS 17.0, followed by descriptive analysis with frequencies, absolute values, tests of central tendency and variability. The statistical tests used were chi-squared and analysis of variance as well as Tukey s post test, when applicable, all with a 95% confidence level. The results shown a prevalence of TMD of 47,1% among patients using PRP and 69,8% among those who didn t, but this result wasn t statistically significant. The mean of the results of masticatory efficiency, WHOQOL and OHIP didn t show association to the presence or absence of PPR and to the lower number of occlusal units of the patients (0, 1, 2 or more occlusal). The association only occurred among the different groups of SDA and the patients with complete dental arch. Taking into account the results, it could be observed that studied patients with low posterior support using lower PRP didn t have better masticatory efficiency, general quality of life, less impacts of their oral conditions in quality of life or not even less temporomandibular dysfunction or better masticatory efficiency when compared to those who didn t use the prosthesis

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays, aesthetics is very appreciated in the social context and a attractive smile is the object of desire in most of patients requiring prosthesis treatment. In case of removable prosthesis, total or partial, this feature is more significant since some or all teeth may be absents. Implants leading to a significant improvement in relation to function and comfort of removable prosthesis users, but the aesthetics of these prostheses had little attention in the current scientific literature. Thus, the aim of present article was to make a review of the literature on the aesthetic features related to rehabilitation with removable prostheses. In present study we found as significant factors for the aesthetics in removable partial and total prostheses: Selection of artificial teeth and their arrangement, characterization of acrylic resin basis and also the types and location of retainers for the removable partial prostheses. We conclude that the involvement and the aesthetic knowledge during the appropriate planning of this process is responsibility of the professional.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The objective of this study was to describe the oral health of elderly people diagnosed with Alzheimer's disease (AD). Study Design: Thirty elderly subjects with AD (mild, moderate, and severe) and 30 without AD (controls) were included in the study. Volunteer-reported oral health data were collected using the General Oral Health Assessment Index (GOHAI). Demographic and oral characteristics were assessed, including the number of natural teeth; number of decayed, missing, and filled teeth (DMTF); oral health index (OHI); removable prosthesis conditions; and oral pathologies. Results: GOHAI values were similar for both groups. Compared with the controls, the subjects with AD had a higher age, DMTF, OHI, and number of oral pathologies and a lower educational level and number of natural teeth. Conclusions: Elderly subjects with AD had poorer oral health than those without the disease. Despite the positive self-perception of their oral health, the oral health of subjects with AD tended to decline as their disease progressed. © 2012 Elsevier Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the stress distribution in mandibular free-end removable partial dentures (RPD) associated with FPD in the abutment teeth considering different inclinations of the residual ridge: (1) horizontal and (2) distal descending ridges and two designs of free-end RPD with different attachment systems were tested: (1) clasp and (2) system ERA. Methods. Axial loads (100 N) were applied on the teeth of the RPD. The images were recorded and the stress distribution was evaluated through photoelastic fringes. Results. In general, the distal descending ridge presented more photoelastic fringes in the region of the roots of the abutment teeth while the horizontal ridge exhibited higher compression in the base of the prosthesis. In the horizontal ridge, the denture with clasp presented more favourable stress distribution than the denture with the system ERA. In the distal descending ridge, the denture with the system ERA relieved the region of the abutment teeth and overloaded the residual ridge. Conclusion: The horizontal ridge presented more favourable performance; the dentures with clasp exhibited better performance for both ridges evaluated; the denture with the system ERA presented better results in the distal descending ridge. © 2013 Informa Healthcare.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. OBJECTIVE: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. LITERATURE REVIEW AND CONCLUSION: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.