943 resultados para Reliable multicast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integration without cytotoxic effects and long-term expression of a transgene constitutes a major challenge in gene therapy and biotechnology applications. In this context, transposons represent an attractive system for gene transfer because of their ability to promote efficient integration of a transgene in a variety of cell lines. However, the transgene integration can lead to insertional mutagenesis and/or unstable transgene expression by epigenetic modifications. These unwanted events may be limited by the use of chromatin control elements called MARs (matrix attachment regions). Indeed, the insertion of these DNA elements next to the transgene usually results in higher and more stable expression by maintaining transgene chromatin in an active configuration and preventing gene silencing. In this study, we tested if the inclusion of the MAR 1-68 in the piggyBac transposon system may lead to efficient and safer transgene integration and ensure reliable stable and long-term expression of a transgene. The MAR-containing transposon construct was tested in CHO cells, for biotechnology applications, and in mesoangioblast cells that can differentiate into muscle cells and are important candidates for potential stem cell therapies of myopathies. We showed that the addition of the MAR 1 -68 in the piggyBac transposon did not interfere with transposition, thereby maintaining high frequency of transgene integrations in these cells. Moreover, the MAR allowed higher transgene expression from fewer transposon integration events. We also found that enriched transgene-expressing cell populations could be obtained without the need of selection pressure. Since antibiotic-enforced selection protocols often result in a higher integrated copy number and mosaic expression patterns, this strategy could benefit many applications in which a low copy number of integrated transgenes and antibiotic-free conditions are desired. In addition, the intramuscular transplantation of mouse tibialis anterior muscles with mesoangioblasts containing the transposon led to widespread and sustained myofiber transgene expression after differentiation of these cells in vivo. These findings indicated that piggyBac vectors may provide a viable approach to achieve stable gene transfer in the context of Duchenne muscular dystrophy therapy. - L'intégration sans effets cytotoxiques et l'expression à long terme d'un transgène constituent un défi majeur en thérapie génique et en biotechnologie. Dans ce contexte, les transposons représentent un système attrayant pour le transfert de gènes en raison de leur capacité à promouvoir l'intégration efficace d'un transgène dans une variété de lignées cellulaires. Toutefois, l'intégration d'un transgène peut conduire à une mutagénèse insertionnelle et/ou à une expression instable due au silençage du transgène suite à des modifications épigénétiques. Ces événements indésirables de silençage génique peuvent être diminués par l'utilisation d'éléments de contrôle de la chromatine appelés MAR (matrix attachment region). En effet, l'insertion de ces éléments d'ADN à proximité du transgène se traduit généralement par une expression plus élevée et plus stable de celui-ci, en permettant le maintien d'une chromatine dans une configuration active autour du transgène et en empêchant l'inactivation du gène. Dans cette étude, nous avons testé si l'inclusion du MAR 1-68 dans le système transposon piggyBac peut améliorer l'efficacité d'intégration de façon sécuritaire et l'expression à long terme d'un transgène. Le transposon contenant l'élément MAR a été testé dans les cellules CHO, couramment utilisées en biotechnologie, et dans des cellules progénitrices appelées mésoangioblastes, qui peuvent se différencier en cellules musculaires, et qui constituent ainsi des candidats prometteurs pour la thérapie à partir de cellules souches de patients souffrant de myopathie. Nous avons montré que l'addition du MAR 1-68 dans le transposon piggyBac n'interfère pas avec la transposition et permet de maintenir une fréquence élevée d'intégration du transgène dans ces deux types cellulaires. De plus, il semble que cette association mène à une meilleure expression du transgène à partir de peu d'événements d'intégration du transposon. En outre, ces populations enrichies en cellules exprimant de façon stable le transgène ont pu être obtenues sans avoir recours à une pression de sélection. Etant donné que les protocoles de sélection basée sur l'utilisation d'antibiotiques conduisent souvent à un nombre plus élevé de copies intégrées et à la variégation de l'expression du transgène et qu'ils impliquent une longue culture in vitro, cette stratégie pourrait profiter à des applications pour lesquelles on souhaite un faible nombre de copies intégrées et/ou l'utilisation d'antibiotiques n'est pas souhaitable. De plus, la transplantation intramusculaire de mésoangioblastes contenant le transposon dans le muscle tibial antérieur de souris a conduit, après la différentiation de ces cellules in vivo, à une expression constante et étendue du transgène dans les myofibres. Ces résultats indiquent que les vecteurs piggyBac pourraient fournir une approche viable pour assurer un transfert de gènes stables dans le contexte d'un traitement de la dystrophic musculaire de Duchenne.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To detect directional couplings from time series various measures based on distances in reconstructed state spaces were introduced. These measures can, however, be biased by asymmetries in the dynamics' structure, noise color, or noise level, which are ubiquitous in experimental signals. Using theoretical reasoning and results from model systems we identify the various sources of bias and show that most of them can be eliminated by an appropriate normalization. We furthermore diminish the remaining biases by introducing a measure based on ranks of distances. This rank-based measure outperforms existing distance-based measures concerning both sensitivity and specificity for directional couplings. Therefore, our findings are relevant for a reliable detection of directional couplings from experimental signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the fundamental operational limits of a class of Gaussian multicast channels with an interference setting. In particular, the paper considers two base stations multicasting separate messages to distinct sets of users. In the presence of channel state information at the transmitters and at the respective receivers, the capacity region of the Gaussian multicast channel with interference is characterized to within one bit. At the crux of this result is an extension to the multicast channel with interference of the Han-Kobayashi or the Chong-Motani-Garg achievable region for the interference channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines how MPEG-2 Transport Stream, used in DVB-T video transmission, can be reliably and efficiently transferred to remote locations over an MPLS network. All the relevant technologies used in this scenario are also discussed in the study. This study was done for Digita Oy, which is a major radio and television content distributor in Finland. The theoretical part of the study begins with the introduction to MPLS technology and continues with explanation of IP Multicast and its components. The fourth section discusses MPEG-2 and the formation and content of MPEG-2 Transport Stream. These technologies were studied in relevant literature and RFC documentation. After the theoretical part of the study, the test setup and the test cases are presented. The results of the test cases, and the conclusions that can be drawn based on them, are discussed in the last section of the study. The tests showed that it is possible to transfer digital video quite reliably over an MPLS network using IP Multicast. By configuring the equipment correctly, the recovery time of the network in case of a failure can be shortened remarkably. Also, the unwanted effect of other traffic on the critical video traffic can be eliminated by defining the Quality of Service parameters correctly. There are, however, some issues that need to be tested further before this setup can be used in broadcast networks. Reliable operation of IP Multicast and proper error correction are the main subjects for future testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Pathologic choroidal neovascularizations (CNV) are implicated in the wet form of age-related macular degeneration (ARMD). Abnormal vessel growth is also observed in disease when hypoxia and/or inflammation occur. Our goal is to establish a standard protocol of laser-induced CNV in mice that have different levels of pigmentation to identify the most reliable animal model.Methods: CNV was induced by 4 burns around the optic disk, using a green argon laser (100μm diameter spot size; 0,05 sec. duration) in C57/Bl6, DBA/1 and Balb/c to ascertain the efficacy of the method in function of retina pigmentation. Five different intensities were tested and Bruch's membrane disruption was identified by the appearance of a bubble at the site of photocoagulation. Fluorescein angiographies (FA) were undertaken 14 days post lesion and CNV area was quantified by immunohistochemistry on cryosections.Results: CNV retina area was related to spot intensity after laser injury. While 180mW and 200mW do not induce reliable CNV (respectively 27.85±0.35% and 29±1.67% of the retina surface), 260mW is required to induce 51,07±8.52% of CNV in C57/Bl6 mice. For the DBA/1 strain, less pigmented, 200mW was sufficient to induce 49.35±3.9% of CNV, indicating that lower intensity are required to induce CNV. Furthermore, an intensity of 180mW induced greater CNV (35.55±6.01%) than in C57/Bl6 mice. Nevertheless, laser did not induce reproducible 50% CNV in Balb/c albino mice for all intensities tested. Isolectin-B4 and GFAP stainings revealed neovessel formation and photoreceptor (PR) degeneration at the impact site. The presence of glia was observed throughout all the retinal layers and angiograms showed fluorescein leakage in pigmented mice.Conclusions: The establishment of a standard protocol to induce CNV and subsequent PR degeneration is of prime importance for the use of the laser-induced CNV model and will allow to evaluate the therapeutic potency of agents to prevent CNV and retinal degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surfactants are used as additives in topical pharmaceuticals and drug delivery systems. The biocompatibility of amino acid-based surfactants makes them highly suitable for use in these fields, but tests are needed to evaluate their potential toxicity. Here we addressed the sensitivity of tumor (HeLa, MCF-7) and non-tumor (3T3, 3T6, HaCaT, NCTC 2544) cell lines to the toxic effects of lysine-based surfactants by means of two in vitro endpoints (MTT and NRU). This comparative assay may serve as a reliable approach for predictive toxicity screening of chemicals prior to pharmaceutical applications. After 24-h of cell exposure to surfactants, differing toxic responses were observed. NCTC 2544 and 3T6 cell lines were the most sensitive, while both tumor cells and 3T3 fibroblasts were more resistant to the cytotoxic effects of surfactants. IC50-values revealed that cytotoxicity was detected earlier by MTT assay than by NRU assay, regardless of the compound or cell line. The overall results showed that surfactants with organic counterions were less cytotoxic than those with inorganic counterions. Our findings highlight the relevance of the correct choice and combination of cell lines and bioassays in toxicity studies for a safe and reliable screen of chemicals with potential interest in pharmaceutical industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: An article by the Swiss AIDS Commission states that patients with stably suppressed viraemia [i.e. several successive HIV-1 RNA plasma concentrations (viral loads, VL) below the limits of detection during 6 months or more of highly active antiretroviral therapy (HAART)] are unlikely to be infectious. Questions then arise: how reliable is the undetectability of the VL, given the history of measures? What factors determine reliability? METHODS: We assessed the probability (henceforth termed reliability) that the n+1 VL would exceed 50 or 1000 HIV-1 RNA copies/mL when the nth one had been <50 copies/mL in 6168 patients of the Swiss HIV Cohort Study who were continuing to take HAART between 2003 and 2007. General estimating equations were used to analyse potential factors of reliability. RESULTS: With a cut-off at 50 copies/mL, reliability was 84.5% (n=1), increasing to 94.5% (n=5). Compliance, the current type of HAART and the first antiretroviral therapy (ART) received (HAART or not) were predictive factors of reliability. With a cut-off at 1000 copies/mL, reliability was 97.5% (n=1), increasing to 99.1% (n=4). Chart review revealed that patients had stopped their treatment, admitted to major problems with compliance or were taking non-HAART ART in 72.2% of these cases. Viral escape caused by resistance was found in 5.6%. No explanation was found in the charts of 22.2% of cases. CONCLUSIONS: After several successive VLs at <50 copies/mL, reliability reaches approximately 94% with a cut-off of 50 copies/mL and approximately 99% with a cut-off at 1000 copies/mL. Compliance is the most important factor predicting reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèseLe syndrome d'apnées obstructives du sommeil (SAOS) est une pathologie respiratoire fréquente. Sa prévalence est estimée entre 2 et 5% de la population adulte générale. Ses conséquences sont importantes. Notamment, une somnolence diurne, des troubles de la concentration, des troubles de la mémoire et une augmentation du risque d'accident de la route et du travail. Il représente également un facteur de risque cardiovasculaire indépendant.Ce syndrome est caractérisé par la survenue durant le sommeil d'obstructions répétées des voies aériennes supérieures. L'arrêt ou la diminution d'apport en oxygène vers les poumons entraîne des épisodes de diminution de la saturation en oxygène de l'hémoglobine. Les efforts ventilatoires visant à lever l'obstacle présent sur les voies aériennes causent de fréquents réveils à l'origine d'une fragmentation du sommeil.La polysomnographie (PSG) représente le moyen diagnostic de choix. Il consiste en l'enregistrement dans un laboratoire du sommeil et en présence d'un technicien diplômé, du tracé électroencéphalographique (EEG), de l'électrooculogramme (EOG), de l'électromyogramme mentonnier (EMG), du flux respiratoire nasal, de l'oxymétrie de pouls, de la fréquence cardiaque, de l'électrocardiogramme (ECG), des mouvements thoraciques et abdominaux, de la position du corps et des mouvements des jambes. L'examen est filmé par caméra infrarouge et les sons sont enregistrés.Cet examen permet entre autres mesures, de déterminer les événements respiratoires obstructifs nécessaires au diagnostic de syndrome d'apnée du sommeil. On définit une apnée lors d'arrêt complet du débit aérien durant au moins 10 secondes et une hypopnée en cas, soit de diminution franche de l'amplitude du flux respiratoire supérieure à 50% durant au moins 10 secondes, soit de diminution significative (20%) de l'amplitude du flux respiratoire pendant au minimum 10 secondes associée à un micro-éveil ou à une désaturation d'au moins 3% par rapport à la ligne de base. La détection des micro-éveils se fait en utilisant les dérivations électroencéphalographiques, électromyographiques et électrooculographiques. Il existe des critères visuels de reconnaissance de ces éveils transitoire: apparition de rythme alpha (8.1 à 12.0 Hz) ou beta (16 à 30 Hz) d'une durée supérieure à 3 secondes [20-21].Le diagnostic de S AOS est retenu si l'on retrouve plus de 5 événements respiratoires obstructifs par heure de sommeil associés soit à une somnolence diurne évaluée selon le score d'Epworth ou à au moins 2 symptômes parmi les suivants: sommeil non réparateur, étouffements nocturne, éveils multiples, fatigue, troubles de la concentration. Le S AOS est gradué en fonction du nombre d'événements obstructifs par heure de sommeil en léger (5 à 15), modéré (15 à 30) et sévère (>30).La polysomnographie (PSG) comporte plusieurs inconvénients pratiques. En effet, elle doit être réalisée dans un laboratoire du sommeil avec la présence permanente d'un technicien, limitant ainsi son accessibilité et entraînant des délais diagnostiques et thérapeutiques. Pour ces mêmes raisons, il s'agit d'un examen onéreux.La polygraphie respiratoire (PG) représente l'alternative diagnostique au gold standard qu'est l'examen polysomnographique. Cet examen consiste en l'enregistrement en ambulatoire, à savoir au domicile du patient, du flux nasalrespiratoire, de l'oxymétrie de pouls, de la fréquence cardiaque, de la position du corps et du ronflement (par mesure de pression).En raison de sa sensibilité et sa spécificité moindre, la PG reste recommandée uniquement en cas de forte probabilité de SAOS. Il existe deux raisons principales à l'origine de la moindre sensibilité de l'examen polygraphique. D'une part, du fait que l'état de veille ou de sommeil n'est pas déterminé avec précision, il y a dilution des événements respiratoires sur l'ensemble de l'enregistrement et non sur la période de sommeil uniquement. D'autre part, en l'absence de tracé EEG, la quantification des micro-éveils est impossible. Il n'est donc pas possible dans l'examen poly graphique, de reconnaître une hypopnée en cas de diminution de flux respiratoire de 20 à 50% non associée à un épisode de désaturation de l'hémoglobine de 3% au moins. Alors que dans l'examen polysomnographique, une telle diminution du flux respiratoire pourrait être associée à un micro-éveil et ainsi comptabilisée en tant qu'hypopnée.De ce constat est né la volonté de trouver un équivalent de micro-éveil en polygraphie, en utilisant les signaux à disposition, afin d'augmenter la sensibilité de l'examen polygraphique.Or plusieurs études ont démontrés que les micro-éveils sont associés à des réactions du système nerveux autonome. Lors des micro-éveils, on met en évidence la survenue d'une vasoconstriction périphérique. La variation du tonus sympathique associée aux micro-éveils peut être mesurée par différentes méthodes. Les variations de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie représentant un marqueur fiable de la vasoconstriction périphérique associée aux micro-réveils, il paraît donc opportun d'utiliser ce marqueur autonomique disponible sur le tracé des polygraphies ambulatoires afin de renforcer la sensibilité de cet examen.Le but de l'étude est d'évaluer la sensibilité des variations de l'amplitude de l'onde de pouls pour détecter des micro-réveils corticaux afin de trouver un moyen d'augmenter la sensibilité de l'examen polygraphique et de renforcer ainsi sont pouvoir diagnostic.L'objectif est de démontrer qu'une diminution significative de l'amplitude de l'onde pouls est concomitante à une activation corticale correspondant à un micro¬réveil. Cette constatation pourrait permettre de déterminer une hypopnée, en polygraphie, par une diminution de 20 à 50% du flux respiratoire sans désaturation de 3% mais associée à une baisse significative de l'amplitude de pouls en postulant que l'événement respiratoire a entraîné un micro-réveil. On retrouve par cette méthode les mêmes critères de scoring d'événements respiratoires en polygraphie et en polysomnographie, et l'on renforce la sensibilité de la polygraphie par rapport au gold standard polysomnographique.La méthode consiste à montrer en polysomnographie qu'une diminution significative de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie est associée à une activation du signal électroencéphalographique, en réalisant une analyse spectrale du tracé EEG lors des baisses d'amplitude du signal d'onde de pouls.Pour ce faire nous avons réalisé une étude rétrospective sur plus de 1000 diminutions de l'amplitude de l'onde de pouls sur les tracés de 10 sujets choisis de manière aléatoire parmi les patients référés dans notre centre du sommeil (CIRS) pour suspicion de trouble respiratoire du sommeil avec somnolence ou symptomatologie diurne.Les enregistrements nocturnes ont été effectués de manière standard dans des chambres individuelles en utilisant le système d'acquisition Embla avec l'ensemble des capteurs habituels. Les données ont été par la suite visuellement analysées et mesurées en utilisant le software Somnologica version 5.1, qui fournit un signal de l'amplitude de l'onde de pouls (puise wave amplitude - PWA).Dans un premier temps, un technicien du sommeil a réalisé une analyse visuelle du tracé EEG, en l'absence des données du signal d'amplitude d'onde de pouls. Il a déterminé les phases d'éveil et de sommeil, les stades du sommeil et les micro¬éveils selon les critères standards. Les micro-éveils sont définis lors d'un changement abrupt dans la fréquence de l'EEG avec un pattern d'ondes thêta-alpha et/ou une fréquence supérieure à 16 Hz (en l'absence de fuseau) d'une durée d'au minimum trois secondes. Si cette durée excède quinze secondes, l'événement correspond à un réveil.Puis, deux investigateurs ont analysé le signal d'amplitude d'onde de pouls, en masquant les données du tracé EEG qui inclut les micro-éveils. L'amplitude d'onde de pouls est calculée comme la différence de valeur entre le zénith et le nadir de l'onde pour chaque cycle cardiaque. Pour chaque baisse de l'amplitude d'onde de pouls, la plus grande et la plus petite amplitude sont déterminées et le pourcentage de baisse est calculé comme le rapport entre ces deux amplitudes. On retient de manière arbitraire une baisse d'au moins 20% comme étant significative. Cette limite a été choisie pour des raisons pratiques et cliniques, dès lors qu'elle représentait, à notre sens, la baisse minimale identifiable à l'inspection visuelle. Chaque baisse de PWA retenue est divisée en 5 périodes contiguës de cinq secondes chacune. Deux avant, une pendant et deux après la baisse de PWA.Pour chaque période de cinq secondes, on a pratiqué une analyse spectrale du tracé EEG correspondant. Le canal EEG C4-A1 est analysé en utilisant la transformée rapide de Fourier (FFT) pour chaque baisse de PWA et pour chaque période de cinq secondes avec une résolution de 0.2 Hz. La distribution spectrale est catégorisée dans chaque bande de fréquence: delta (0.5 à 4.0 Hz); thêta (4.1 à 8.0Hz); alpha (8.1 à 12.0 Hz); sigma (12.1 à 16 Hz) et beta (16.1 à 30.0 Hz). La densité de puissance (power density, en μΥ2 ) pour chaque bande de fréquence a été calculée et normalisée en tant que pourcentage de la puissance totale. On a déterminé, ensuite, la différence de densité de puissance entre les 5 périodes par ANOVA on the rank. Un test post hoc Tukey est été utilisé pour déterminer si les différences de densité de puissance étaient significatives. Les calculs ont été effectués à l'aide du software Sigmastat version 3.0 (Systat Software San Jose, California, USA).Le principal résultat obtenu dans cette étude est d'avoir montré une augmentation significative de la densité de puissance de l'EEG pour toutes les bandes de fréquence durant la baisse de l'amplitude de l'onde de pouls par rapport à la période avant et après la baisse. Cette augmentation est par ailleurs retrouvée dans la plupart des bande de fréquence en l'absence de micro-réveil visuellement identifié.Ce résultat témoigné donc d'une activation corticale significative associée à la diminution de l'onde de pouls. Ce résulat pourrait permettre d'utiliser les variations de l'onde de pouls dans les tracés de polygraphie comme marqueur d'une activation corticale. Cependant on peut dire que ce marqueur est plus sensible que l'analyse visuelle du tracé EEG par un technicien puisque qu'on notait une augmentation de lactivité corticale y compris en l'absence de micro-réveil visuellement identifié. L'application pratique de ces résultats nécessite donc une étude prospective complémentaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Even though much improvement has been made in plant transformation methods, the screening of transgenic plants is often a laborious work. Most approaches for detecting the transgene in transformed plants are still timeconsuming, and can be quite expensive. The objective of this study was to search for a simpler method to screen for transgenic plants. The infiltration of kanamycin (100 mg/mL) into tobacco leaves resulted in conspicuous chlorotic spots on the non-transgenic plant leaves, while no spots were seen on the leaves of transformed plants. This reaction occurred regardless of age of the tested plants, and the method has proven to be simple, fast, non-destructive, relatively cheap, and reliable. These results were comparable to those obtained by the polymerase chain reaction (PCR) amplification of the transgene using specific primers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the spatial resolution of a computed tomography (CT) scanner with an automatic approach developed for routine quality controls when varying CT parameters. The methods available to assess the modulation transfer functions (MTF) with the automatic approach were Droege's and the bead point source (BPS) methods. These MTFs were compared with presampled ones obtained using Boone's method. The results show that Droege's method is not accurate in the low-frequency range, whereas the BPS method is highly sensitive to image noise. While both methods are well adapted to routine stability controls, it was shown that they are not able to provide absolute measurements. On the other hand, Boone's method, which is robust with respect to aliasing, more resilient to noise and provides absolute measurements, satisfies the commissioning requirements perfectly. Thus, Boone's method combined with a modified Catphan 600 phantom could be a good solution to assess CT spatial resolution in the different CT planes.