153 resultados para Recoil


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The double ionization of helium by electron impact for 106 eV incident energy was studied in a kinematically complete experiment by using a reaction microscope. The pattern of the angular correlation of the three emitted electrons was analyzed by selecting different values of the recoil ion longitudinal momentum. The Wannier predicted geometry appears when the recoil ion carries the full initial projectile momentum. It was found that at this low impact energy, the outgoing electrons still remember the initial-state collision information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various nuclear reactions like quasi-fission, fusion-fission or particle and cluster evaporation from excited compound nuclei were studied in heavy-ion reactions at the velocity filter SHIP of GSI. The velocity filter offers the possibility to detect all reaction products under zero degree relative to the beam direction. Together with the measurement of the product velocity distribution this allows for an identification of the underlying reaction mechanism. This article is focussed on reactions of Mg-25 and Ni-64 beams on Pb-206,Pb-207 targets at energies of 5.9 x A MeV and 8.7 x A MeV. Besides evaporation residues from Mg-25 + Pb-206 collisions we found evidence for rotation and quasi-fission of nuclear molecules formed in the entrance channel after the capture stage. The break-up of the systems showed a preferred clustering leading to isotopes in the region 84 <= Z <= 88 and 122 <= N <= 127 of the chart of nuclei.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The principle and technique details of recoil ion momentum imaging are discussed and summarized. The recoil ion momentum spectroscopy built at the Institute of Modern Physics (Lanzhou) is presented. The first results obtained at the setup are analyzed. For 30 keV He2+ on He collision, it is found that the capture of single electron occurs dominantly into the first excited states, and the related scattering angle results show that the ground state capture occurs at large impact parameters, while the capture into excited states occurs at small impact parameters. The results manifest the collision dynamics for the sub-femto-second process can be studied through the techniques uniquely. Finally, the future possibilities of applications of the recoil ion momentum spectroscopy in other fields are outlined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A recoil separator Wien-filter which was developed for the Radioactive Ion Beam Line in Lanzhou (RIBLL) as an extension is described. It consists of 2 quadruple triplets and a standard Wien-filter. It was designed for study of the fusion-evaporation reactions. The overall design, background suppression, the transmission efficiency, the angular acceptance and the momentum acceptance have been described. All the performances fulfil the designed requirements. Based on the test results, with some modifications the investigations of the nuclei with Z <= 110 and the drip-line nuclei in the medium-heavy mass region can be carried out with this facility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relative partial cross sections for C-13(6+)-Ar collisions at 4.15-11.08 keV/u incident energy are measured. The cross-section ratios sigma(2E)/sigma(SC), sigma(3E)/sigma(SC), sigma(4E)/sigma(SC) and sigma(5E)/sigma(SC) are approximately the constants of 0.51 +/- 0.05, 0.20 +/- 0.03, 0.06 +/- 0.03 and 0.02 +/- 0.01 in this region. The significance of the multi-electron process in highly charged ions (HCIs) with argon collisions is demonstrated (sigma(ME)/sigma(SC) as high as 0.79 +/- 0.06). In multi-electron processes, it is shown that transfer ionization is dominant while pure electron capture is weak and negligible. For all reaction channels, the cross-sections are independent of the incident energy in the present energy region, which is in agreement with the static characteristic of classic models, i.e. the molecular Coulomb over-the-barrier model (MCBM), the extended classical over-the-barrier (ECBM) and the semiempirical scaling laws (SL). The result is compared with these classical models and with our previous work of C-13(6+)-Ne collisions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gamma rays following the beta(+)/EC decay of Ir-176,Ir-178 nuclei have been investigated using in-beam gamma-ray experiment. In addition, with the aid of a helium-jet recoil fast tape transport system, the beta(+)/EC decay of Ir-176 was further studied, the new gamma rays were proved and a low-spin isomer was proposed in Ir-176. The isomeric state was analysized according to the systematics in neighboring nuclei.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Employing the recoil ion momentum spectroscopy we investigate the collision between He2+ and argon atoms. By measuring the recoil longitudinal momentum the energy losses of projectile are deduced for capture reaction channels. It is found that in most cases for single- and double-electron capture, the inner electron in the target atom is removed, the recoil ion is in singly or multiply excited states (hollow ion is formed), which indicates that electron correlation plays an important role in the process. The captured electrons prefer the ground states of the projectile. It is experimentally demonstrated that the average energy losses are directly related to charge transfer and electronic configuration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The beta(+)/EC decay of doubly odd Ir-176 has been investigated using Nd-146(Cl-35, 5n gamma)Ir-176 heavy ion fusion evaporation reaction at 210MeV bombarding energy. With the aid of a helium-jet recoil fast tape transport system, the reaction products were transported to a low-background location for measurements. Based on the data analysis, the previously published gamma rays in Ir-176 decay were proved, moreover, 3 new levels and 10 new gamma rays were assigned to Ir-176 decay. The new level scheme of Os-176 with low excitation energy has been established. The time spectra of typical gamma rays clearly indicate a long-lived low-spin isomer in Ir-176 nuclide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electron emission yields from the interaction of slow highly charged ions (SHCI) He2+, O2+ and Ne2+ with clean Si surface are measured separately. It is found that electron emission yield gamma increases proportionally to projectile kinetic energy E-p/M-p, ranging from 0.75 keV/u to 10.5 keV/u (i.e. 3.8 x 10(5) m/s <= v(p) <= 1.42 x 10(6) m/s), and it is higher for heavy ions (O2+ and Ne2+) than for light ion (He2+). For O2+ and Ne2+, gamma increases with Z(p) decreasing in our energy range, and it shows quite different from the result for higher projectile kinetic energy. After calculating the stopping power by using TRIM 2006, it is found that the fraction of secondary electrons induced by recoil atoms increases significantly at lower projectile energy, thereby leads to the differences in gamma for heavy ions O2+ and Ne2+ between lower and higher projectile kinetic energy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The processes of transfer ionization in He2+ -He collisions at energies ranging from 20 to 40 keV have been studied experimentally by means of cold target recoil ions momentum spectroscopy. From the longitudinal momentum spectra of recoil ions, different mechanisms of transfer ionization have been obtained. The results show that one of the electrons of helium atom being captured into the ground state of projectile ion He2+ and the other one emitted to the continuum state of projectile or target are the dominant mechanisms of transfer ionization. The autoionization cross section of projectile after two-electron capture into a double excited state is small. Transfer ionization for one target electron capture into ground state and the other one into the continuum of projectile mainly occurs at large impact parameter collisions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The momentum distributions of recoil ions were measured in the single ionization of neon by electron impact at incident energies between 80 and 2300 eV. It was found that there are a noticeable number of recoil ions carrying large momenta, and the relative contributions of these ions becomes more pronounced with the further decrease of incident electron energy. These observed behaviors indicate that there is a strong projectile-target-core interaction in the single-ionization reaction. By comparing our results with those of electron-neon elastic scattering, we concluded that the elastic scattering of the projectile electron on the target core plays an important role at low and intermediate collision energies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The neutron deficient nuclide Ir-175 was produced by irradiation of Nd-146 with 210 MeV Cl-35 via a fusion-evaporation reaction channel. The reaction products were transported to a low-background location using a helium-jet recoil fast-moving tape-transport system for measurement. The experimental devices and data analysis method are introduced. Based on the decay-curve fitting of the beta-delayed gamma ray from Ir-175, realized by the least-square method, a new long-lived isomeric state of Ir-175 is proposed and briefly discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

论文介绍了超重充气谱仪的基本原理及此类装置的国际现状,在此基础上,对中国科学院近代物理研究所超重谱仪充气段的基本情况进行了描述。本工作采用离线和在线的方法对超重谱仪充气段进行了调试。在离线实验中,通过改变α源及探测装置的位置,确定了谱仪的接收度,得到了谱仪对不同能量及发散度的α粒子的传输效率,测试了充气对谱仪传输效率的影响,并对靶厚与传输效率间的关系进行了模拟研究。根据离线实验的结果,对谱仪进行了合理的改进。在线实验利用重离子束流轰击薄靶并观测靶反冲核的方法,确认了束流监测装置的最佳探测器和最佳安装位置,测试了谱仪对一些靶反冲核的传输效率。通过初步调试,测试了该超重谱仪充气段的一些基本性能,测量了谱仪的一些相关参数,为其投入今后的物理实验研究提供了必要的经验和参考

Relevância:

10.00% 10.00%

Publicador:

Resumo:

论文介绍了超重充气谱仪的基本原理及此类装置的国际现状,在此基础上,对中国科学院近代物理研究所超重谱仪充气段的基本情况进行了描述。本工作采用离线和在线的方法对超重谱仪充气段进行了调试。在离线实验中,通过改变α源及探测装置的位置,确定了谱仪的接收度,得到了谱仪对不同能量及发散度的α粒子的传输效率,测试了充气对谱仪传输效率的影响,并对靶厚与传输效率间的关系进行了模拟研究。根据离线实验的结果,对谱仪进行了合理的改进。在线实验利用重离子束流轰击薄靶并观测靶反冲核的方法,确认了束流监测装置的最佳探测器和最佳安装位置,测试了谱仪对一些靶反冲核的传输效率。通过初步调试,测试了该超重谱仪充气段的一些基本性能,测量了谱仪的一些相关参数,为其投入今后的物理实验研究提供了必要的经验和参考

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文主要致力于建立一个用多谱勒能移反冲距离法测寿命的主要方法。对所设计加工的多谱勒能移反冲距离法测寿命的实验装置--PLUNGER的结构特点作了详细的说明,描述了用电容法测量和监视PLUNGER的靶与阻止膜间微小距离及其变化的实验,并从中得出零点距即靶与阻止膜间所能达到的最小距离为6-9#mu#m。用激光反射法测定了PLUNGER在运动中靶与阻止膜间的平行度的改变。还叙述了该PLUNGER装置用于~(13)P束轰击~(93)Nb靶的在束实验详细过程及数据处理,给出了~(120)Xe的基带各能级寿命及~(121)Cs、~(117)I的部分能级寿命。最后讨论了探测器的立体角效应、束流照射的热效应等对寿命测量的影响