914 resultados para Reagent Kits


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tris[tetrachlorobenzenediolato]phosphate(v) anion (TRISPHAT) is known to be an efficient NMR chiral shift agent for various chiral cationic species. Here we compare the efficiency of TRISPHAT and of a chiral lanthanide shift reagent for the determination of the enantiomeric purity of the chiral building block [Ru(phen)[2]PY[2]][2][+] which possesses C[2] symmetry. We also discuss our results in terms of the geometry of interaction between the Ru(II) complex and the TRISPHAT anion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract 2,4-Dinitrophenol was employed with benzyloxy-bis-(diisopropylamino)phosphine to synthesise the cyclic phosphate derivatives of a series of alkane diols (HO–(CH2)n–OH, n=2–6) in good isolated yields. Tetrazole and DNP were compared by 31P NMR spectroscopy for their ability to catalyse the cyclisation at the P(III) stage. Investigation of the phosphate triester stability under various oxidation and chromatographic conditions resulted in the optimisation of the isolation procedures of the chemically unstable cyclic compounds. Conditions for debenzylation were developed to yield the corresponding cyclic phosphodiesters quantitatively. The methodology was further applied to the preparation and isolation of the cyclic phosphate derivative of a carbohydrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monensin, a carboxylic acid ionophore, is commonly fed to poultry to control coccidiosis. A method for rapid analysis of unextracted poultry plasma samples has been developed based on a novel immunoassay format: one-step all-in-one dry reagent time resolved fluorimetry. All assay specific components were pre-dried onto microtitration plate wells. Only addition of the serum sample diluted in assay buffer was required to perform analysis. Results were available one hour after sample addition. The limit of detection (mean + 3s) of the assay calculated from the analysis of 23 known negative samples was 14.2 ng ml(-1). Intra- and inter-assay RSD were determined as 15.2 and 7.4%, respectively, using a plasma sample fortified with 50 ng ml(-1) monensin. Eight broiler chickens were fed monensin at a dose rate of 120 mg kg(-1) feed for one week, blood sampled then slaughtered without drug withdrawal. Plasma monensin concentrations, as determined by the fluoroimmunoassay ranged from 101-297 ng ml(-1). This compared with monensin liver concentrations, determined by LC-MS, which ranged fi om 13-41 ng g(-1). The fluoroimmunoassay described is extremely user friendly, gives particularly rapid results and is suitable for the detection and quantification of plasma monensin residues. Data from medicated poultry suggest that analysis of plasma may be useful in predicting the extent of monensin liver residues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple dry chemistry time-resolved fluorescence immunoassay (TR-FIA) method was developed for the measurement of zeranol in bovine urine samples. The samples were purified by immunoaffinity chromatography and a specificity-enhanced zeranol antibody was employed in the immunoassay. This resulted in a highly selective method, which had only negligible reactivity with Fusarium spp, toxins. The all-in-one-well dry chemistry concept made the assay very simple to use because all the assay-specific reagents were already present in the reaction wells in dry form. Only the addition of diluted sample extract was required to perform the competitive one-step TR-FIA and the results were available in less than 1 h. The analytical limit of detection (mean + 3s) for the immunoassay was 0.16 ng ml(-1) (n=12) and the functional limit of detection for the whole method, estimated by the analysis of zeranol-free samples, was 1.3 ng ml(-1) (n=20). The recovery of zeranol at the level of 2 ng ml(-1) was 99% (n=18) and the within-assay variation ranged between 4.5 and 9.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present studies describe our recent work on expanding the use of the Burgess reagent and its reaction with oxiranes. Several new variants of the Burgess reagent and its chiral auxiliary version were evaluated for their thermal stability by NMR spectroscopy. Three new versions of the reagent were synthesized and their stability was determined. The reactivity of all five Burgess reagents was compared in a dehydration reaction and reactions with epoxides and diols. Progress toward a chemoenzymatic synthesis of morphine is also included in this report. The synthesis began with the whole cell oxidation of bromobenzene by Escherichia coli JMI09(pDTG601). The preparation of several precursors for a key step involving the lohnson-Claisen rearrangement and progress toward the total synthesis are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burgess reagent first prepared by E. M. Burgess in 1968, is a mild and selective dehydrating agent for secondary and tertiary alcohols and due to the amphipolar nature it is gainfully employed in a number of creative synthetic ventures. A close examination of the structure of Burgess reagent reveals that it can act as a 1,2-dipole. To the best of our knowledge, no attempts have been made to tap full synthetic potential of the amphipolar nature of this reagent and no reports on 1,3-dipolar addition to a σ-bond in acyclic systems are available in literature. In this context, we propose to unravel novel applications of Burgess reagent based on its amphipolar nature. Rich and multifaceted chemistry of nitrones form the basis of many successful chemical transformations used in attractive synthetic strategies. For the last 50 years special attention has been given to nitrones due to their successful application as building blocks in the synthesis of various natural and biologically active compounds. Our interest in nitrones stems out of its unique character: i.e. it is a 1,3-dipole exhibiting distinct nucleophilic activity. We reasoned that 1,3-dipole possessing significant nucleophilicity should react with amphipolar Burgess reagent with elimination of triethylamine to give the corresponding five-membered ring product by formal dipolar addition to a σ bond. To test this hypothesis we studied the reaction of nitrones with Burgess reagent. This thesis reveals our attempts to explore the [3+2] annulation reaction of nitrones with Burgess reagent which was found to be followed by a rearrangementinvolving C-to-N aryl migration, ultimately resulting in diarylamines and carbamates. We have also examined the reaction of cyanuric chloride with nitrones in DMF with a view to exploit the nucleophilicty of nitrones and to unravel the migratory aptitude, if any, observed in this reaction

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The invention relates to immunoassays, methods for carrying out immunoassays, immunoassay kits and methods for manufacturing immunoassay kits. In particular, the invention has relevance to capillary (especially microcapillary) immunoassay technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we describe general flow processes for the synthesis of alkyl and aryl azides, and the development of a new monolithic triphenylphosphine reagent, which provides a convenient format for the use of this versatile reagent in flow. The utility of these new tools was demonstrated by their application to a flow Staudinger aza-Wittig reaction sequence. Finally, a multistep aza-Wittig, reduction and purification flow process was designed, allowing access to amine products in an automated fashion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recovery and stability of DNA for the detection and genotyping of HPV in UCM-containing specimens, after exposure to denaturing reagents and stored for up to 2 years were evaluated. Samples were collected from 60 women who had cervical cytology specimens harboring cervical intraepithelial neoplasia (CIN) 2 or 3. All samples were stored in UCM and had been frozen at -20 degrees C following the addition of the denaturing reagent (sodium hydroxide) and the removal of the aliquot required for Hybrid Capture 2 testing for the identification of HPV DNA. The samples had been stored for 6, 12 and 24 months (20 samples for each storage time). HPV DNA extraction was performed according to a protocol designed specifically and the presence and quality of DNA was confirmed by human P-globin detection using the consensus primers G73 and G74. HPV DNA was amplified using the consensus primers PGMY09 and PGMY11, and reverse line-blot hybridization was used to detect type-specific amplicons for 37 HPV types. The DNA extracted from the denatured specimen was recovered in 57/60 (95%) of the samples. HPV DNA was detected in 56/57 (98%) of the recovered samples. Twenty-six of the 56 samples recovered (48%) were genotyped successfully. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first one-pot synthesis of neutral and electron-rich [hydroxy(tosyloxy)iodo]arenes (HTIBs) from iodine and arenes is presented, thereby avoiding the need for expensive iodine(III) precursors. A large set of including a polyfluorinated analogue, can be obtained from the corresponding aryl iodide under the same conditions. The reaction proceeds under mild conditions, without excess reagents, and is fast and high-yielding. Together, the two presented routes give access to a wide range of HTIBs, which are useful reagents in a variety of synthetic transformations.