964 resultados para Raman amplifiers
Resumo:
Dissertação de Mestrado em Conservação e Restauro área de Especialização de Cerâmica e Vidro
Resumo:
Thesis presented in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the subject of Electrical and Computer Engineering
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Modern fully integrated receiver architectures, require inductorless circuits to achieve their potential low area, low cost, and low power. The low noise amplifier (LNA), which is a key block in such receivers, is investigated in this thesis. LNAs can be either narrowband or wideband. Narrowband LNAs use inductors and have very low noise figure, but they occupy a large area and require a technology with RF options to obtain inductors with high Q. Recently, wideband LNAs with noise and distortion cancelling, with passive loads have been proposed, which can have low NF, but have high power consumption. In this thesis the main goal is to obtain a very low area, low power, and low-cost wideband LNA. First, it is investigated a balun LNA with noise and distortion cancelling with active loads to boost the gain and reduce the noise figure (NF). The circuit is based on a conventional balun LNA with noise and distortion cancellation, using the combination of a common-gate (CG) stage and common-source (CS) stage. Simulation and measurements results, with a 130 nm CMOS technology, show that the gain is enhanced by about 3 dB and the NF is reduced by at least 0.5 dB, with a negligible impact on the circuit linearity (IIP3 is about 0 dBm). The total power dissipation is only 4.8 mW, and the active area is less than 50 x 50 m2 . It is also investigated a balun LNA in which the gain is boosted by using a double feedback structure.We propose to replace the load resistors by active loads, which can be used to implement local feedback loops (in the CG and CS stages). This will boost the gain and reduce the noise figure (NF). Simulation results, with the same 130 nm CMOS technology as above, show that the gain is 24 dB and NF is less than 2.7 dB. The total power dissipation is only 5.4 mW (since no extra blocks are required), leading to a figure-of-merit (FoM) of 3.8 mW
Resumo:
Raman spectroscopy has been applied to characterize fiber dyes and determine the discriminating ability of the method. Black, blue, and red acrylic, cotton, and wool samples were analyzed. Four excitation sources were used to obtain complementary responses in the case of fluorescent samples. Fibers that did not provide informative spectra using a given laser were usually detected using another wavelength. For any colored acrylic, the 633-nm laser did not provide Raman information. The 514-nm laser provided the highest discrimination for blue and black cotton, but half of the blue cottons produced noninformative spectra. The 830-nm laser exhibited the highest discrimination for red cotton. Both visible lasers provided the highest discrimination for black and blue wool, and NIR lasers produced remarkable separation for red and black wool. This study shows that the discriminating ability of Raman spectroscopy depends on the fiber type, color, and the laser wavelength.
Resumo:
The aim of this work is to evaluate the capabilities and limitations of chemometric methods and other mathematical treatments applied on spectroscopic data and more specifically on paint samples. The uniqueness of the spectroscopic data comes from the fact that they are multivariate - a few thousands variables - and highly correlated. Statistical methods are used to study and discriminate samples. A collection of 34 red paint samples was measured by Infrared and Raman spectroscopy. Data pretreatment and variable selection demonstrated that the use of Standard Normal Variate (SNV), together with removal of the noisy variables by a selection of the wavelengths from 650 to 1830 cm−1 and 2730-3600 cm−1, provided the optimal results for infrared analysis. Principal component analysis (PCA) and hierarchical clusters analysis (HCA) were then used as exploratory techniques to provide evidence of structure in the data, cluster, or detect outliers. With the FTIR spectra, the Principal Components (PCs) correspond to binder types and the presence/absence of calcium carbonate. 83% of the total variance is explained by the four first PCs. As for the Raman spectra, we observe six different clusters corresponding to the different pigment compositions when plotting the first two PCs, which account for 37% and 20% respectively of the total variance. In conclusion, the use of chemometrics for the forensic analysis of paints provides a valuable tool for objective decision-making, a reduction of the possible classification errors, and a better efficiency, having robust results with time saving data treatments.
Resumo:
La contrefaçon de médicaments est un délit qui n'a cessé d'augmenter ces dernières années. Diff érents spectromètres portables ont été proposés sur le marché afi n de permettre une détection rapide des contrefaçons sur le terrain. Les spectroscopies Raman, Infrarouge et Proche Infrarouge présentent des caractéristiques intéressantes pour l'analyse de médicaments douteux, propriétés qui sont exposées dans cet article. Une comparaison des diff érents instruments portables permet de présenter l'intérêt d'utiliser ces spectromètres pour la détection de contrefaçons.
Resumo:
A transportable Raman spectrometer was tested for the detection of illicit drugs seized during border controls. In a first step, the analysis methodology was optimized using reference substances such as diacetylmorphine (heroin), cocaine and amphetamine (as powder or liquid forms). Adequate focalisation distance and times of analysis, influence of daylight and artificial light sources, repeatability and limits of detection were studied. In a second step the applications and limitations of the technique to detect the illicit substances in different mixtures and containers was evaluated. Transportable Raman spectroscopy was found to be adequate for a rapid screen of liquids and powders for the detection and identification of controlled substances. Additionally, it had the advantage over other portable techniques, such as ion mobility spectrometry, of being non-destructive and capable of rapid analysis of large quantities of substances through containers such as plastic bags and glass bottles.
Resumo:
Raman spectroscopy has become an attractive tool for the analysis of pharmaceutical solid dosage forms. In the present study it is used to ensure the identity of tablets. The two main applications of this method are release of final products in quality control and detection of counterfeits. Twenty-five product families of tablets have been included in the spectral library and a non-linear classification method, the Support Vector Machines (SVMs), has been employed. Two calibrations have been developed in cascade: the first one identifies the product family while the second one specifies the formulation. A product family comprises different formulations that have the same active pharmaceutical ingredient (API) but in a different amount. Once the tablets have been classified by the SVM model, API peaks detection and correlation are applied in order to have a specific method for the identification and allow in the future to discriminate counterfeits from genuine products. This calibration strategy enables the identification of 25 product families without error and in the absence of prior information about the sample. Raman spectroscopy coupled with chemometrics is therefore a fast and accurate tool for the identification of pharmaceutical tablets.
Resumo:
Raman spectroscopy has become a widespread technique for the analysis ofpharmaceutical solid forms. The application proposed here is the investigationof counterfeit medicines. This serious global issue requires quick and accurateidentification methods to fight against this phenomenon. Thanks to its chemicalselectivity, rapidity of analysis and potential of generating repeatable spectralprofiles, Raman spectroscopy presents distinct advantages for the analysis ofcounterfeits. Combined with chemometric tools, the technique enablesthe detection, the determination of chemical composition and the profiling ofmedicine counterfeits.
Resumo:
RESUME La méthode de la spectroscopie Raman est une technique d'analyse chimique basée sur l'exploitation du phénomène de diffusion de la lumière (light scattering). Ce phénomène fut observé pour la première fois en 1928 par Raman et Krishnan. Ces observations permirent à Raman d'obtenir le Prix Nobel en physique en 1930. L'application de la spectroscopie Raman a été entreprise pour l'analyse du colorant de fibres textiles en acrylique, en coton et en laine de couleurs bleue, rouge et noire. Nous avons ainsi pu confirmer que la technique est adaptée pour l'analyse in situ de traces de taille microscopique. De plus, elle peut être qualifiée de rapide, non destructive et ne nécessite aucune préparation particulière des échantillons. Cependant, le phénomène de la fluorescence s'est révélé être l'inconvénient le plus important. Lors de l'analyse des fibres, différentes conditions analytiques ont été testées et il est apparu qu'elles dépendaient surtout du laser choisi. Son potentiel pour la détection et l'identification des colorants imprégnés dans les fibres a été confirmé dans cette étude. Une banque de données spectrale comprenant soixante colorants de référence a été réalisée dans le but d'identifier le colorant principal imprégné dans les fibres collectées. De plus, l'analyse de différents blocs de couleur, caractérisés par des échantillons d'origine inconnue demandés à diverses personnes, a permis de diviser ces derniers en plusieurs groupes et d'évaluer la rareté des configurations des spectres Raman obtenus. La capacité de la technique Raman à différencier ces échantillons a été évaluée et comparée à celle des méthodes conventionnelles pour l'analyse des fibres textiles, à savoir la micro spectrophotométrie UV-Vis (MSP) et la chromatographie sur couche mince (CCM). La technique Raman s'est révélée être moins discriminatoire que la MSP pour tous les blocs de couleurs considérés. C'est pourquoi dans le cadre d'une séquence analytique nous recommandons l'utilisation du Raman après celle de la méthode d'analyse de la couleur, à partir d'un nombre de sources lasers le plus élevé possible. Finalement, la possibilité de disposer d'instruments équipés avec plusieurs longueurs d'onde d'excitation, outre leur pouvoir de réduire la fluorescence, permet l'exploitation d'un plus grand nombre d'échantillons. ABSTRACT Raman spectroscopy allows for the measurement of the inelastic scattering of light due to the vibrational modes of a molecule when irradiated by an intense monochromatic source such as a laser. Such a phenomenon was observed for the first time by Raman and Krishnan in 1928. For this observation, Raman was awarded with the Nobel Prize in Physics in 1930. The application of Raman spectroscopy has been undertaken for the dye analysis of textile fibers. Blue, black and red acrylics, cottons and wools were examined. The Raman technique presents advantages such as non-destructive nature, fast analysis time, and the possibility of performing microscopic in situ analyses. However, the problem of fluorescence was often encountered. Several aspects were investigated according to the best analytical conditions for every type/color fiber combination. The potential of the technique for the detection and identification of dyes was confirmed. A spectral database of 60 reference dyes was built to detect the main dyes used for the coloration of fiber samples. Particular attention was placed on the discriminating power of the technique. Based on the results from the Raman analysis for the different blocs of color submitted to analyses, it was possible to obtain different classes of fibers according to the general shape of spectra. The ability of Raman spectroscopy to differentiate samples was compared to the one of the conventional techniques used for the analysis of textile fibers, like UV-Vis Microspectrophotometry (UV-Vis MSP) and thin layer chromatography (TLC). The Raman technique resulted to be less discriminative than MSP for every bloc of color considered in this study. Thus, it is recommended to use Raman spectroscopy after MSP and light microscopy to be considered for an analytical sequence. It was shown that using several laser wavelengths allowed for the reduction of fluorescence and for the exploitation of a higher number of samples.
Resumo:
Thermal analysis, powder diffraction, and Raman scattering as a function of the temperature were carried out on K2BeF4. Moreover, the crystal structure was determined at 293 K from powder diffraction. The compound shows a transition from Pna21 to Pnam space group at 921 K with a transition enthalpy of 5 kJ/mol. The transition is assumed to be first order because the compound shows metastability. Structurally and spectroscopically the transition is similar to those observed in (NH4)2SO4, which suggests that the low-temperature phase is ferroelectric. In order to confirm it, the spontaneous polarization has been computed using an ionic model.