954 resultados para Radioactive waste disposal.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwaters; and surface waters around two waste disposal areas at Rio Claro municipality, nearly in the center of São Paulo State, Brazil, were chemically analysed with the purpose of evaluating the influence on the water quality of the chemicals released without any care with the environment and using a prevention system for the containment of environmentally polluting substances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling. Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation of all the test results indicates that the contamination plume has already overreached the landfill's west-northwest borders. Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing gradually, indicating the need for continuous monitoring of the groundwater.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation reports the results of a study realized in an area related to the development of sand mining activities, which belongs to Sibelco Mineração Ltd. The site is located around Analândia municipality, nearly in the center of São Paulo State, Brazil. Hydrochemical analyses of groundwater were realized under different periods of time, with the aim of evaluating the possibility of release of several constituents to the liquid phase, which may be a source of pollution of the surface hydrological resources and of the deeper Guarani aquifer. This is because the site is located at the recharge area of Guarani aquifer and some tributaries from Corumbataí river may also be suffering contamination, implying on the impoverishment of the water quality that are very important resources in the region, as they are extensively used for drinking purposes, among others.© 2011 WIT Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A contaminated site from a downstream municipal solid waste disposal site in Brazil was investigated by using a 3D resistivity and induced polarization (IP) imaging technique. This investigation purpose was to detect and delineate contamination plume produced by wastes. The area was selected based on previous geophysical investigations, and chemical analyses carried out in the site, indicating the presence of a contamination plume in the area. Resistivity model has successfully imaged waste presence (rho < 20 Omega m), water table depth, and groundwater flow direction. A conductive anomaly (rho < 20 Omega m) outside wastes placement was interpreted as a contamination plume. Chargeability model was also able to imaging waste presence (m > 31 mV/V), water table depth, and groundwater flow direction. A higher chargeability zone (m > 31 mV/V) outside wastes placement and following conductive anomaly was interpreted as a contamination plume. Normalized chargeability (MN = m/rho) confirmed polarizable zone, which could be an effect of a salinity increase (contamination plume), and the clay presence in the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work demonstrates that the plasma - induced combustion of intermediate to low-level radioactive waste is a suitable method for volume reduction and stabilization. Weaknesses of existing facilities can be overcome with novel developments. Plasma treatment of LILW has a high economical advantage by volume reduction for storage in final repositories.

Relevância:

100.00% 100.00%

Publicador: