986 resultados para ROOT-CANAL SEALER
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The prognosis of tooth replantation is usually related to the need of endodontic treatment, which has a direct relationship with the occurrence of root resorptions. Several studies have been undertaken in an attempt to prevent, delay, or treat these complications, which are the main causes of loss of replanted teeth. This literature review examines research evidence on intracanal dressings and root canal filling materials used in cases of tooth replantation. A comprehensive search was performed in the Medline/Pubmed, Bireme and Scielo full-text electronic journal databases to retrieve English-language articles referring to these topics that had been published between 1964 and 2010. Calcium hydroxide (CH) remains the usually recommended choice as an intracanal medicament in replanted teeth; however, there is evidence to support the initial use of a corticosteroid-antibiotic combination such as Ledermix paste to control potential early resorption, prior to the introduction of CH where the beneficial effect in the treatment of progressive root resorption has been well proven. Regarding root filling materials, CH-containing sealers are a good option because of their biological properties. Accurate diagnosis and adequate treatment plan may constitute very complex tasks, particularly in tooth avulsion because several variables are involved. In addition to the technical knowledge and clinical experience directed toward the quality of treatment, patient education may favorably influence the survival of replanted teeth.
Resumo:
The major concern in the therapeutics of tooth replantation refers to the occurrence of root resorption and different approaches have been proposed to prevent or treat these complications. The purpose of this study was to evaluate tissue response to delayed replantation of anterior rat teeth treated endodontically using calcium hydroxide, Sealapex, and Endofill without the placement of gutta-percha cones. Thirty rats had their right upper incisor extracted and maintained in dry storage for 60 min. After removal of the dental papilla, enamel organ, pulp tissue, and periodontal ligament remnants, the teeth were immersed in 2% sodium fluoride phosphate acidulated, pH 5.5, for 10 min. The root canals were dried with absorbent paper points and the teeth were assigned to three groups (n = 10) according to the filling material. Group I - calcium hydroxide and propyleneglycol paste, Group II - Sealapex, and Group III - Endofill. The sockets were irrigated with saline and the teeth were replanted. Replacement resorption, inflammatory resorption and ankylosis were observed in all groups. Although the occurrence of inflammatory resorption was less frequent in Group I, there were no statistically significant differences among the groups. It may be concluded that compared to the paste, filling the root canals with Sealapex and Endofill sealers without the placement of gutta-percha cones did not provide better results.
Resumo:
The purpose of this study was to investigate the influence of the type of vehicle (distilled water or propyleneglycol) on the response of apical tissues of dogs' teeth after root canal filling with mineral trioxide aggregate (MTA) at two different limits. Forty roots of incisors and premolars of two adult dogs were used. After pulpectomy, the root canals were prepared biomechanically, and the roots had the apical cemental barrier penetrated with a #15 K-file and widened to a #25 K-file. The root canals were assigned to four groups according to the vehicle used for MTA (ProRoot-MTA; Tulsa Dental, Tulsa, OK) preparation and the limit of root canal filling: group 1, filling with MTA/distilled water to the limit of the cemental canal; group 2, overfilling with MTA/distilled water, group 3, filling with MTA/propyleneglycol to the limit of the cemental canal; and group 4, overfilling with MTAlpropyleneglycol. The animals were killed by anesthetic overdose 90 days after endodontic treatment and the anatomic pieces were prepared for histomorphological analysis. The sections were stained with hematoxylin and eosin and Brown and Brenn techniques. The results showed that MTA pastes prepared with either distilled water or propyleneglycol as vehicles had similar biological behavior (p > 0.05); root fillings placed at the cemental canal limit showed better results than the overfillings (p = 0.01), and MTA/propyleneglycol paste was more easily placed into the root canals than MTA/distilled water paste.
Resumo:
The purpose of this study was to compare the reaction of rat subcutaneous connective tissue to 0.9% sterile saline, 2.5% sodium hypochlorite (NaOCl), 5.25% NaOCl and 2% chlorhexidine gluconate solution or gel. Six circles were demarcated on the dorsal skin of 24 male Wistar rats, leaving 2 cm between each circle. Using a syringe, 0.1 mL of each root canal irrigant was injected subcutaneously into 5 circles. In the 6th circle, the needle of an empty syringe was introduced into the skin, but no irrigant was injected (control group). Evaluations were undertaken at 2 h, 48 h, 14 days and 30 days post-procedure. Tissue samples were excised, embedded in paraffin blocks and 3-mu m-thick sections were obtained and stained with hematoxylin and eosin. The areas of inflammatory reaction were evaluated and analyzed statistically by ANOVA and Tukey's test. The control group showed few or no inflammatory reaction areas in the subcutaneous tissue. 0.9% saline solution, 2.0% chlorhexidine solution and 2.5% NaOCl showed a good biocompatibility, as very mild inflammatory reaction was detected at 14 days and tissue repair occurred at 30 days. 5.25% NaOCl was the most toxic irrigant, as the number of inflammatory cells remained elevated at 14 and 30 days. The group treated with 2.0% chlorhexidine gluconate gel presented a moderate inflammatory response at 14 days, which decreased at 30 days, being considered similar to that of the control group, 0.9% saline solution, 2.0% chlorhexidine solution and 2.5% NaOCl at this experimental period.
Resumo:
The aim of this study was to evaluate two root canal filling techniques used in teeth that had their apical foramen disrupted and compare the apical infiltration with an ideal clinical situation. Twenty-seven freshly extracted single-rooted teeth were selected and radiographed to confirm the existence of a single and straight root canal. The crowns were removed at a mean distance of 11 mm from the apex. The teeth had the root canals instrumented and were randomly assigned to 3 groups (n=9): ND group-root canals were filled using the lateral compaction technique and no disruption was performed; DRF group-the apical constriction was disrupted by advancing a #40 K-file 1 mm beyond the original working length, the canals were reinstrumented to create an apical ledge at 1 mm from the apical foramen and were obturated with a master gutta-percha cone with same size as the last file used for reinstrumentation; DF group - the teeth had the apical constriction disrupted and the canals were obturated with a master gutta-percha cone that fit at 1 mm from the apex. The teeth were submitted to dye leakage test with Rhodamine B for 7 days, using vaccum on the initial 5 min. The teeth were sectioned longitudinally and the leakage was measured in a linear fashion from apex to crown. There was no statistically significant difference (p>0.05) between the groups that had the apical foramen disrupted (DF, DRF), but significant difference was found between the disrupted groups and the non-disrupted one (p<0.01). In conclusion, none of the evaluated techniques was able to prevent apical infiltration, so working length so the working length determination has to be established and maintained carefully.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the radiopacity of five root canal filling materials (AH Plus, Intrafill, Roeko Seal, Epiphany, and EndoRez). Following the International Organization of Standardization 687612001, five circular specimens (10 X 1 mm) were made from each material. After the material set, radiographs were made using occlusal film and a graduated aluminum step-wedge varying in thickness from 2 to 16 mm. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses/second, and distance of 33.5 cm. The radiographs were digitized, and the radiopacity was compared with the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were analyzed using ANOVA and Tukey tests. AH Plus and Epiphany were the most radiopaque materials (9.8 and 8.8 mm Al, respectively), followed by EndoRez (7.2 mm Al). Roeko Seal and Intrafill presented the lowest radiopacity values (5.7 and 6.1 mm Al, respectively). Although the materials evaluated demonstrated different radiopacities, all had values above the minimum recommended by the international Organization of Standardization.
Resumo:
The aim of this study was to evaluate the efficacy of three rotary instrument systems (K3, ProTaper and Twisted File) in removing calcium hydroxide residues from root canal walls. Thirty-four human mandibular incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA, and filled with a calcium hydroxide intracanal dressing. After 7 days, the calcium hydroxide dressing was removed using the following rotary instruments: G1 - NiTi size 25, 0.06 taper, of the K3 System; G2 - NiTi F2, of the ProTaper System; or G3 - NiTi size 25, 0.06 taper, of the Twisted File System. The teeth were longitudinally grooved on the buccal and lingual root surfaces, split along their long axis, and their apical and cervical canal thirds were evaluated by SEM (×1000). The images were scored and the data were statistically analyzed using the Kruskall Wallis test. None of the instruments removed the calcium hydroxide dressing completely, either in the apical or cervical thirds, and no significant differences were observed among the rotary instruments tested (p > 0.05).
Resumo:
Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim To evaluate differences between anatomic and radiographic measurements of root canal wall thickness (RCWT) after each root canal preparation stage during post placement.Methodology Twenty mandibular premolars with a single canal were decoronated and the roots embedded in resin using a teflon muffle. Roots were sectioned horizontally at a pre-established level and canals were prepared for post placement. Endodontic hand files were used for root canal preparation, followed by Gates Glidden drills and Peeso reamers. Standardized radiographs and photographs at pre-established measurement levels were taken before preparation, after root canal instrumentation, after Gates Glidden preparation and after Peeso enlargement. All images were digitized and RCWT at the mesial and distal walls measured (IMAGETOOL 3.0). Differences between radiographic and anatomic measurements were analysed with paired t-tests. ANOVA was used to compare the percentages of radiographic distortions.Results Regardless of the time-point evaluated, RCWT determined by radiographs were greater than the respective anatomic measurements (P < 0.05). The difference detected at each stage was similar and constant (P > 0.05).Conclusions Throughout preparation for post placement, radiographic images overestimated the RCWT by approximately 25%, regardless of the clinical stage evaluated.
Resumo:
The aim of this report is to contribute to a better understanding of the radiographic, clinical and anatomic findings in maxillary second premolars. This paper reports the endodontic treatment of two cases of three-rooted three-canal maxillary second premolars in different patients, and two sound maxillary second premolars also with three canals and three independent roots in a sibling of one of the patients. Although the presence of maxillary second premolars with one or two canals and one root is much more common, other anatomic conditions can be found. A correct clinical and radiographic diagnosis based on knowledge of root canal anatomy and critical interpretation of radiographs is necessary for a safer and successful endodontic treatment of these teeth.