85 resultados para RADIOPACITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the antibiofilm activity against Enterococcus faecalis, compressive strength. and radiopacity of Portland cement (PC) added to zirconium oxide (ZrO2), as radiopacifier, with or without nanoparticulated zinc oxide (ZnO).The following experimental materials were evaluated: PC, PC + ZrO2, PC + ZrO2 + ZnO (5%), and PC + ZrO2 + ZnO (10%). Antibiofilm activity was analyzed by using direct contact test (DCT) on Enterococcus faecalis biofilm, for 5 h or 15 h. The analysis was conducted by using the number of colony-forming units (CFU/mL). The compressive strength was performed in a mechanical testing machine. For the radiopacity tests, the specimens were radiographed together with an aluminium stepwedge. The results were submitted to ANOVA and Tukey tests, with level of significance at 5%. The results showed that all materials presented similar antibiofilm activity (

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Portland cement has shown similar biological properties to calcium hydroxide, but its radiopacity is lower. Therefore, the addition of materials that minimize this deficiency should be considered. OBJECTIVE: To evaluate the apical sealing ability and pH of a white Portland cement added of several radiopacifying agents. MATERIAL AND METHODS: Forty bovine roots with incomplete apices were selected, and the foraminal openings were standardized to PM 720G bur. After the external root sealing, an apical intracanal barrier 10.0 mm thick was executed with the white Portland cement powder, pure or added of a radiopacifying agent (iodoform, zinc oxide or bismuth subnitrate), and distilled water (0.37 mL). The apical roots were immersed 24h in water in humid atmosphere, and after that they were immersed 24h in 2% Rhodamine B, under vacuum. In sequence, the roots were longitudinally sectioned, the root fragments were photographed, the images were digitalized and the apical infiltration was measured by the Image Tool program. The pH solutions were also evaluated, in 24h and 48h and 7 and 30 days. Data were submitted to Anova test. RESULTS: The zinc oxide solution has the lowest apical infiltration in relation to the other groups (p < 0.05). The pH behavior varied during the analysis, and in the period of 24h all groups showed the highest values (p < 0.05). CONCLUSION: The type of radiopacifying agent used interferes in the sealing ability of the apical barrier, and zinc oxide showed to be the most beneficial one. The pH varies according to the period of analysis, and the highest values were obtained in the first 24h (p < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the physicochemical properties and bioactivity of two formulations of calcium silicate-based cements containing additives (CSCM) or resin (CSCR), associated with radiopacifying agents zirconium oxide (ZrO2) and niobium oxide (Nb2O5) as micro- and nanoparticles; calcium tungstate (CaWO4); and bismuth oxide (Bi2O3). MTA Angelus was used as control. Methods. Surface features and bioactivity were evaluated by scanning electron microscopy and the chemical composition by energy dispersive X-ray spectrometry (EDS-X). Results. CSCM and CSCR presented larger particle sizes than MTA. Hydroxyapatite deposits were found on the surface of some materials, especially when associated with the radiopacifier with ZrO2 nanoparticles. All the cements presented calcium, silicon, and aluminum in their composition. Conclusion. Both calcium silicate-based cements presented composition and bioactivity similar to MTA when associated with the radiopacifiers evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to characterize and to evaluate the bioactivity potential of experimental root canal sealers (ES) based on Portland cement, epoxy resin with nano- and micro-particles of niobium or zirconium oxide used as radiopacifiers in comparison to AH Plus and MTA Fillapex. Methods Specimens of the sealers (10 mm in diameter × 1 mm thick) were prepared and the radiopacity was evaluated according to ISO 6876 (2012) specifications. Characterization of the sealers was performed under the scanning electron microscope (SEM) immediately after setting and after immersion for 28 days in Hank's balanced salt solution (HBSS). In addition X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy were also performed. The pH and calcium ion release were measured after 1, 7, 14, 21 and 28 days after completion of seating using a digital pH meter and an atomic absorption spectrophotometer, respectively. Results The experimental sealers exhibited an average radiopacity of 2.5 mm thickness of aluminum, which was similar to MTA Fillapex (P > 0.05) and inferior to AH Plus (P < 0.05). AH Plus did not show bioactivity. Although the experimental sealers did not exhibit the formation of hydration product, they encouraged the deposition of crystalline spherical structures of calcium deficient phosphate. The highest pH and calcium release values were observed with the experimental sealers (P < 0.01). ES-Nb-micro was the only sealer to present hexagonal shaped crystal deposition. Significance Novel root canal sealers based on a mixture of Portland cement, epoxy resin and radiopacifier exhibited a degree of bioactivity although no evidence of cement hydration was demonstrated on material characterization. The radiopacifier particle size had limited effect on the sealer microstructure and chemical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peripheral cement-ossifying fibroma is a relatively common gingival growth of a reactive rather than neoplastic nature, whose pathogenesis is uncertain. It predominantly affects adolescents and young adults, with peak prevalence between 10 and 19 years. We report here the clinical case of a 5-year-old girl with disease duration of 3 years, who was followed up for 4 years, showing a gingival health and normal radiopacity of bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: It has been suggested that bone grafts combined with platelet rich plasma (PRP) present greater density than bone grafts without PRP after healing process. However, this result may depend on proportion PRP/autogenous bone (AB) graft used. Objective: The purpose of this study was to analyze radiographically the influence of the proportion PRP/particulate autogenous bone (AB) graft on bone healing in surgically created criticalsize defects (CSD) in rat calvaria. Material and method: 50 rats were divided into 5 groups: C, AB, AB/PRP-50, AB/PRP-100 and AB/PRP-150. A 5 mm diameter CSD was created in the calvarium of each animal. In Group C the defect was filled by blood clot only. In Group AB the defect was filled with 0.01 mL of AB graft. In groups AB/ RP-50, AB/PRP-100 and AB/PRP-150 the defects were filled with 0.01 mL of AB graft combined with 50, 100 and 150 µL of PRP, respectively. All animals were euthanized at 30 days post-operative. Standardized radiographic images of the rat calvaria were obtained using Digora System (Soredex, Finland). The images were evaluated by three examiners using scores that indicated the percentage of radiopacity of the defect. The obtained data were subjected to statistical analysis (Kruskal-Wallis test, p < 0.05). Result: Group C presented radiopacity significantly lower than groups AB, AB/PRP-50, AB/PRP-100 and AB/PRP-150. Group AB/PRP-50 showed radiopacity significantly greater than groups AB/PRP-100 and AB. Conclusion: It can be concluded that the proportion PRP/AB graft influences bone healing in CSD in rat calvaria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)