976 resultados para RADIATION DOSAGE


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oral administration with solid dosage forms is a common route in the drug therapy widely used. The drug release by the disintegration process occurs in several gastrointestinal tract (GIT) regions. AC Biosusceptometry (ACB) was originally proposal to characterize the disintegration process of tablets in vitro and in the human stomach, through changes in magnetic signals. The aim of this work was to employ a multisensor ACB system to monitoring magnetic tablets and capsules in the human GIT and to obtain the magnetic images of the disintegration process. The ACB showed accuracy to quantify the gastric residence time, the intestinal transit time and the magnetic images allowed to visualize the disintegration of magnetic formulations in the GIT. The ACB is a non-invasive, radiation free technique, completely safe and harmless to the volunteers and had demonstrated potential to evaluate pharmaceutical dosage forms in the human gastrointestinal tract. © 2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques. © 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA) in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. METHODS: We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. RESULTS AND CONCLUSION: The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm). The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine whether a 3-mm isotropic target margin adequately covers the prostate and seminal vesicles (SVs) during administration of an intensity-modulated radiation therapy (IMRT) treatment fraction, assuming that daily image-guided setup is performed just before each fraction. MATERIALS AND METHODS: In-room computed tomographic (CT) scans were acquired immediately before and after a daily treatment fraction in 46 patients with prostate cancer. An eight-field IMRT plan was designed using the pre-fraction CT with a 3-mm margin and subsequently recalculated on the post-fraction CT. For convenience of comparison, dose plans were scaled to full course of treatment (75.6 Gy). Dose coverage was assessed on the post-treatment CT image set. RESULTS: During one treatment fraction (21.4+/-5.5 min), there were reductions in the volumes of the prostate and SVs receiving the prescribed dose (median reduction 0.1% and 1.0%, respectively, p<0.001) and in the minimum dose to 0.1 cm(3) of their volumes (median reduction 0.5 and 1.5 Gy, p<0.001). Of the 46 patients, three patients' prostates and eight patients' SVs did not maintain dose coverage above 70 Gy. Rectal filling correlated with decreased percentage-volume of SV receiving 75.6, 70, and 60 Gy (p<0.02). CONCLUSIONS: The 3-mm intrafractional margin was adequate for prostate dose coverage. However, a significant subset of patients lost SV dose coverage. The rectal volume change significantly affected SV dose coverage. For advanced-stage prostate cancers, we recommend to use larger margins or improve organ immobilization (such as with a rectal balloon) to ensure SV coverage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The radiation dose rates at flight altitudes can increase by orders of magnitude for a short time during energetic solar cosmic ray events, so called ground level enhancements (GLEs). Especially at high latitudes and flight altitudes, solar energetic particles superposed on galactic cosmic rays may cause radiation that exceeds the maximum allowed dosage limit for the general public. Therefore the determination of the radiation dose rate during GLEs should be as reliable as possible. Radiation dose rates along flight paths are typically determined by computer models that are based on cosmic ray flux and anisotropy parameters derived from neutron monitor and/or satellite measurements. The characteristics of the GLE on 15 April 2001 (GLE60) were determined and published by various authors. In this work we compare these results and investigate the consequences on the computed radiation dose rates along selected flight paths. In addition, we compare the computed radiation dose rates with measurements that were made during GLE60 on board two transatlantic flights.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma irradiation has been widely used as a breeding technique to obtain new cultivars in ornamental species such as Alstroemeria, where several cultivars have been obtained through rhizome radiation. The optimum dosage for an appropriate induction of mutation must be considered for breeding purposes and it depends mainly on plant susceptibility. Thus in this study in vitro cultured rhizomes of Alstroemeria aurea were irradiated with a gamma source using different dosages to evaluate the direct effect produced. Damage and number of rhizome sprouting were observed and recorded during 61 days after irradiation. At the end of this period, rhizomes were weighted and mortality was evaluated. Both mortality and weight increased depending on dosage. All irradiated rhizomes showed early sprouting in comparison with control (0 Gy) and no significant difference in final number of shoots after 61 days among irradiated treatments was observed. Bleaching and necrosis was observed in all irradiated rhizomes and was more evident at higher doses. LD50 was established at about 40 Gy and the optimum dosage to induce mutation was suggested between 2.5 and 5 Gy, when the growth was reduced in 50%, and probably this dosage could be used for breeding purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work analysed the feasibility of using a fast, customized Monte Carlo (MC) method to perform accurate computation of dose distributions during pre- and intraplanning of intraoperative electron radiation therapy (IOERT) procedures. The MC method that was implemented, which has been integrated into a specific innovative simulation and planning tool, is able to simulate the fate of thousands of particles per second, and it was the aim of this work to determine the level of interactivity that could be achieved. The planning workflow enabled calibration of the imaging and treatment equipment, as well as manipulation of the surgical frame and insertion of the protection shields around the organs at risk and other beam modifiers. In this way, the multidisciplinary team involved in IOERT has all the tools necessary to perform complex MC dosage simulations adapted to their equipment in an efficient and transparent way. To assess the accuracy and reliability of this MC technique, dose distributions for a monoenergetic source were compared with those obtained using a general-purpose software package used widely in medical physics applications. Once accuracy of the underlying simulator was confirmed, a clinical accelerator was modelled and experimental measurements in water were conducted. A comparison was made with the output from the simulator to identify the conditions under which accurate dose estimations could be obtained in less than 3 min, which is the threshold imposed to allow for interactive use of the tool in treatment planning. Finally, a clinically relevant scenario, namely early-stage breast cancer treatment, was simulated with pre- and intraoperative volumes to verify that it was feasible to use the MC tool intraoperatively and to adjust dose delivery based on the simulation output, without compromising accuracy. The workflow provided a satisfactory model of the treatment head and the imaging system, enabling proper configuration of the treatment planning system and providing good accuracy in the dosage simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar radiation, especially ultraviolet A (UVA) and ultraviolet B (UVB), can cause damage to the human body, and exposure to the radiation may vary according to the geographical location, time of year and other factors. The effects of UVA and UVB radiation on organisms range from erythema formation, through tanning and reduced synthesis of macromolecules such as collagen and elastin, to carcinogenic DNA mutations. Some studies suggest that, in addition to the radiation emitted by the sun, artificial sources of radiation, such as commercial lamps, can also generate small amounts of UVA and UVB radiation. Depending on the source intensity and on the distance from the source, this radiation can be harmful to photosensitive individuals. In healthy subjects, the evidence on the danger of this radiation is still far from conclusive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB), porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of acupuncture in minimizing the severity of radiation-induced xerostomia in patients with head and neck cancer. A total of 24 consecutive patients receiving > 5000 cGy radiotherapy (RT) involving the major salivary glands bilaterally were assigned to either the preventive acupuncture group (PA, n = 12), treated with acupuncture before and during RT, or the control group (CT, n = 12), treated with RT and not receiving acupuncture. After RT completion, clinical response was assessed in all patients by syalometry, measuring the resting (RSFR) and stimulated (SSFR) salivary flow rates, and by the visual analogue scale (VAS) regarding dry mouth-related symptoms. Statistical analyses were performed with repeated-measures using a mixed-effect modeling procedure and analysis of variance. An alpha level of 0.05 was accepted for statistical significance. Although all patients exhibited some degree of impairment in salivary gland functioning after RT, significant differences were found between the groups. Patients in the PA group showed improved salivary flow rates (RSFR, SSFR; p < 0.001) and decreased xerostomia-related symptoms (VAS, p < 0.05) compared with patients in the CT group. Although PA treatment did not prevent the oral sequelae of RT completely, it significantly minimized the severity of radiation-induced xerostomia. The results suggest that acupuncture focused in a preventive approach can be a useful therapy in the management of patients with head and neck cancer undergoing RT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common side effect of radiotherapy used in the treatment of oral cancer is the occurrence of structural and physiological alterations of the salivary glands due to exposure to ionizing radiation, as demonstrated by conditions such as decreased salivary flow. The present study evaluated ultrastructural alterations in the parotid glands of rats receiving a fractionated dose (1,500-cGy) of radiation emitted by a Cesium-137 source and rats that were not subjected to ionizing radiation. After sacrifice, the parotid glands were removed and examined by transmission electron microscopy. Damage such as cytoplasmic vacuolization, dilatation of the endoplasmic reticulum and destruction of mitochondria, as well as damage to the cellular membrane of acinar cells, were observed. These findings lead to the conclusion that ionizing radiation promotes alterations in the glandular parenchyma, and that these alterations are directly related to the dose level of absorbed radiation. Certain phenomena that appear in the cytoplasm and nuclear material indicate that ionizing radiation causes acinar cell death (apoptosis).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the emission of gravitational radiation in the context of a previously studied metric nonsymmetric theory of gravitation. The part coming from the symmetric part of the metric coincides with the mass quadrupole moment result of general relativity. The one associated to the antisymmetric part of the metric involves the dipole moment of the fermionic charge of the system. The results are applied to binary star systems and the decrease of the period of the elliptical motion is calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionizing radiation OR) imposes risks to human health and the environment. IR at low doses and low (lose rates has the potency to initiate carcinogenesis. Genotoxic environmental agents such as IR trigger a cascade of signal transduction pathways for cellular protection. In this study, using cDNA microarray technique, we monitored the gene expression profiles in lymphocytes derived from radiation-ex posed individuals (radiation workers). Physical dosimetry records on these patients indicated that the absorbed dose ranged from 0.696 to 39.088 mSv. Gene expression analysis revealed statistically significant transcriptional changes in a total of 78 genes (21 up-regulated and 57 clown-regulated) involved in several biological processes such as ubiquitin cycle (UHRF2 and PIAS1), DNA repair (LIG3, XPA, ERCC5, RAD52, DCLRE1C), cell cycle regulation/proliferation (RHOA, CABLES2, TGFB2, IL16), and stress response (GSTP1, PPP2R5A, DUSP22). Some of the genes that showed altered expression profiles in this study call be used as biomarkers for monitoring the chronic low level exposure in humans. Additionally, alterations in gene expression patterns observed in chronically exposed radiation workers reinforces the need for defining the effective radiation dose that causes immediate genetic damage as well as the long-term effects on genomic instability, including cancer.