849 resultados para Preparos dentários
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Avaliação das dimensões e relacionamento dos arcos dentários após tratamento com Bionator de Balters
Resumo:
The deficiency of data in the literature took us to evaluate the Bionator of Balters appliance in the alterations of the dimensions and the relationship of the dental archs in children with malocclusion Class II, division 1 of Angle. The experimental group was constituted by 36 pairs cast Caucasians patients, aged between 7 years and 10 months - 11 years and 8 months, being 10 females and 8 males. The Levene´s test showed statistical evidences of likeness among the groups. Statistical analysis was preceded and showed significant alterations (p < 0,005) in the variable indicatives of maxillary first molars' distance, overjet, upper arch total length, upper arch anterior length, right molar relationship, left molar relationship, right canine relationship and left canine relationship. On the other hand, there wasn't significant alteration related to the lower arch and maxillary intercanines distance. The Balters' Bionator appliance had a favorable effect in the improvement of the correction of the malocclusion in Class II (foremost in molars and canines relationship) and transversal increase of the upper arch, mainly in the posterior area of arch.
Resumo:
This study evaluated the maxillary transversal changes caused by the rapid maxillary expansion (RME) accomplished by Hyrax appliance. Sixteen children from both genders were selected and treated, with ages between 7.7 to 10.8 years, who presented unilateral or bilateral posterior crossbite. Postero-anterior radiographs were taken at the beginning of the treatment, end and post-retention period. The treatment promoted an average opening of 8.8 mm of IMD (intermolar distance), 2.33 mm of IAD (interapex distance) and none of IID (interincisal distance). At the end of retention period, relapse was observed, with a decrease of 4.3 mm of IMD, 1.23 mm of IAD, a non-significant enlargement of IID (0,38 mm).These results confirm the significant influence of Hyrax appliance on transverse dimensions, represented by enlargement of IMD and IAD and its effectiveness to solve posterior crossbites.
Resumo:
The aim of this study is to describe, illustrate and discuss a simple, effective and rational method for preparing anterior all-ceramic restorations. This procedure uses a reduced number of diamond burs and a few clinical steps. The biological, mechanical, functional and aesthetic principles are obtained in a reasonable manner, regarding the requirements’ supported by the contemporary aesthetic dentistry. At the end of reading, it is expected that the professionals understand the design of the axial and cervical dental walls. Finally, the dental preparations will be made in a rapid and efficient manner. Despite the citation of specific diamond burs, it is expected that the reader use them as a reference. The understanding of their geometric configuration and volume are more important than their manufacturer’s reference number. Other manufacturers have diamond burs with the same geometric configuration of those recommended in this technique. Thus, the clinical professional must select the diamond points according to their manufacturer of choice.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Patients infected with HIV can present several complications related to oral health. Today, the reduction of morbidity and mortality is evidenttreatment with antiviral enhances the quality of life of patients. The increase in comfort, stability, function and improving quality of life have led these patients to seek treatment with osseointegrated implants. This study aimed to discuss, based on the literature, the rehabilitation treatment with osseointegrated implants in patients HIV positive. For this we carried out a literature review including the subject in the databases: PubMed, Cochrane, ISI Dentistry and Oral Science in the last 20 years. The issue was addressed for the first time in 1998, describing a clinical case, the patient had successful rehabilitation with osseointegrated implants. However, the literature states that the indications must be carefully analyzed (2007), since there are few prospective controlled studies. There is doubt as to the use of dental implant therapy in patients with HIV-positive, and the complications are related to the patient’s systemic condition. It is essential to understand the clinical manifestations and complications of the disease before the implant therapy. It is observed that the dental implant therapy in patients with HIV positive is a predictable treatment option, it´s need an adequate control of oral and systemic conditions, and studies with larger sample, longer follow-up and randomized studies are important for evaluating the success therapy.
Resumo:
The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.
Resumo:
Various surface treatments of dental implants have been developed in order to ensure anchorage to bone tissue, optimization of the determinants of electronic structure, crystallinity, composition and properties. Coating techniques have been proposed in order tocreate unionbiochemicalable to accelerate the early stages ofbone tissue, combining the positive properties of titanium and its alloys bioactivity of ceramic materials. This paper discusses protocol for handling the SBF coating of titanium alloys. The apatite phase nucleation occurs by immersing the substrate in synthetic solution simulating blood plasma (Simulated Body Fluid). The protocol allows manipulation of the SBF solution to establish guidelines regarding the usestreamlinedand organized to make practical application.