995 resultados para Portable devices


Relevância:

40.00% 40.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Office of Driver and Pedestrian Programs, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Positive emotions are central to human life and have implications to the overall quality of people's life (Fredrickson, 1998). This paper reports on positive experiences with two types of portable interactive devices (PIDs), specifically media/entertainment and medical/health devices. The study is based on a six-month longitudinal study exploring people's emotional experience and how PIDs mediate these experiences in everyday contexts. Previous findings by the authors (Gomez, Popovic & Blackler, 2011) presented four categories of activities including Feature, Functional, Mediation and Auxiliary activities and their relationship to emotional experience. The paper presents emotional experiences with specific activities reported with a focus on positive emotions. It concludes with a discussion of the findings on positive experiences and the implications for the future design of PIDs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A microchip thermocycler, fabricated from silicon and Pyrex #7740 glass, is described. Usual resistive heating has been replaced by induction heating, leading to much simpler fabrication steps. Heating and cooling rates of 6.5 and 4.2 degreesC/s, respectively have been achieved, by optimising the heater dimensions and heating frequency (similar to200 kHz). Four devices are mounted on a heater, resulting in low power consumption (similar to 1.4 W per device on the average). Using simple on-off electronic temperature control, a temperature stability within -0.2 degreesC is achieved. Features such as induction heating, good temperature control, battery operation, and low power consumption make the device suitable for portable applications, particularly in polymerase chain reaction (PCR) systems. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present the design and development of a portable, hand-operated composite compliant mechanism for estimating the failure-load of cm-sized stiff objects whose stiffness is of the order of 10 s of kN/m. The motivation for the design comes from the need to estimate the failure-load of mesoscale cemented sand specimens in situ, which is not possible with traditional devices used for large specimens or very small specimens. The composite compliant device, developed in this work, consists of two compliant mechanisms: a force-amplifying compliant mechanism (FaCM) to amplify sufficiently the force exerted by hand in order to break the specimen and a displacement-amplifying compliant mechanism (DaCM) to enable measurement of the force using a proximity sensor. The two mechanisms are designed using the selection-maps technique to amplify the force up to 100N by about a factor of 3 and measure the force with a resolution of 15 mN. The composite device, made using a FaCM, a DaCM, and a Hall effect-based proximity sensor, was tested on mesoscale cemented sand specimens that were 10mm in diameter and 20mm in length. The results are compared with those of a large commercial instrument. Through the experiments, it was observed that the failure-load of the cemented sand specimens varied from 0.95N to 24.33 N, depending on the percentage of cementation and curing period. The estimation of the failure-load using the compliant device was found to be within 1.7% of the measurements obtained using the commercial instrument and thus validating the design. The details of the design, prototyping, specimen preparation, testing, and the results comprise the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical microscopy is a versatile diagnostic platform used for diagnosis of a multitude of diseases. In the recent past, many microfluidics based point-of-care diagnostic devices have been developed, which serve as alternatives to microscopy. However, these point-of-care devices are not as multi-functional and versatile as clinical microscopy. With the use of custom designed optics and microfluidics, we have developed a versatile microscopy-based cellular diagnostic platform, which can be used at the point of care. The microscopy platform presented here is capable of detecting infections of very low parasitemia level (in a very small quantity of sample), without the use of any additional computational hardware. Such a cost-effective and portable diagnostic device, would greatly impact the quality of health care available to people living in rural locations of the world. Apart from clinical diagnostics, it's applicability to field research in environmental microbiology has also been outlined. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tissue micro array (TMA) is based on the idea of applying miniaturization and a high throughput approach to hybridization-based analyses of tissues. It facilitates biomedical research on a large scale in a single experiment; thus representing one of the most commonly used technologies in translational research. A critical analysis of the existing TMA instruments indicates that there are potential constraints in terms of portability, apart from costs and complexity. This paper will present the development of an affordable, configurable, and portable TMA instrument to allow an efficient collection of tissues, especially in instrument-to-tissue scenarios. The purely mechanical instrument requires no energy sources other than the user, is light weight, portable, and simple to use. [DOI: 10.1115/1.4004922]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The technique of diffusive gradients in thin films (DGT) is often employed to quantify labile metals in situ; however, it is a challenge to perform the measurements in-field. This study evaluated the capability of field-portable X-ray fluorescence (FP-XRF) to swiftly generate elemental speciation information with DGT. Biologically available metal ions in environmental samples passively preconcentrate in the thin films of DGT devices, providing an ideal and uniform matrix for XRF nondestructive detection. Strong correlation coefficients (r > 0.992 for Mn, Cu, Zn, Pb and As) were obtained for all elements during calibration. The limits of quantitation (LOQ) for the investigated elements of FP-XRF on DGT devices are 2.74 for Mn, 4.89 for Cu, 2.89 for Zn, 2.55 for Pb, and 0.48 for As (unit: µg cm(-2)). When Pb and As co-existed in the solution trials, As did not interfere with Pb detection when using Chelex-DGT. However, there was a significant enhancement of the Pb reading attributed to As when ferrihydrite binding gels were tested, consistent with Fe-oxyhydroxide surfaces absorbing large quantities of As. This study demonstrates the value of the FP-XRF technique to rapidly and nondestructively detect the metals accumulated in DGT devices, providing a new and simple diagnostic tool for on-site environmental monitoring of labile metals/metalloids

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prostate cancer (PCa) is the most common form of cancer in men, in Europe (World Health Organization data). The most recent statistics, in Portuguese territory, confirm this scenario, which states that about 50% of Portuguese men may suffer from prostate cancer and 15% of these will die from this condition. Its early detection is therefore fundamental. This is currently being done by Prostate Specific Antigen (PSA) screening in urine but false positive and negative results are quite often obtained and many patients are sent to unnecessary biopsy procedures. This early detection protocol may be improved, by the development of point-of-care cancer detection devices, not only to PSA but also to other biomarkers recently identified. Thus, the present work aims to screen several biomarkers in cultured human prostate cell lines, serum and urine samples, developing low cost sensors based on new synthetic biomaterials. Biomarkers considered in this study are the following: prostate specific antigen (PSA), annexin A3 (ANXA3), microseminoprotein-beta (MSMB) and sarcosine (SAR). The biomarker recognition may occurs by means of molecularly imprinted polymers (MIP), which are a kind of plastic antibodies, and enzymatic approaches. The growth of a rigid polymer, chemically stable, using the biomarker as a template allows the synthesis of the plastic antibody. MIPs show high sensitivity/selectivity and present much longer stability and much lower price than natural antibodies. This nanostructured material was prepared on a carbon solid. The interaction between the biomarker and the sensing-material produces electrical signals generating quantitative or semi-quantitative data. These devices allow inexpensive and portable detection in point-of-care testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From the early stages of the twentieth century, polyaniline (PANI), a well-known and extensively studied conducting polymer has captured the attention of scientific community owing to its interesting electrical and optical properties. Starting from its structural properties, to the currently pursued optical, electrical and electrochemical properties, extensive investigations on pure PANI and its composites are still much relevant to explore its potentialities to the maximum extent. The synthesis of highly crystalline PANI films with ordered structure and high electrical conductivity has not been pursued in depth yet. Recently, nanostructured PANI and the nanocomposites of PANI have attracted a great deal of research attention owing to the possibilities of applications in optical switching devices, optoelectronics and energy storage devices. The work presented in the thesis is centered around the realization of highly conducting and structurally ordered PANI and its composites for applications mainly in the areas of nonlinear optics and electrochemical energy storage. Out of the vast variety of application fields of PANI, these two areas are specifically selected for the present studies, because of the following observations. The non-linear optical properties and the energy storing properties of PANI depend quite sensitively on the extent of conjugation of the polymer structure, the type and concentration of the dopants added and the type and size of the nano particles selected for making the nanocomposites. The first phase of the work is devoted to the synthesis of highly ordered and conducting films of PANI doped with various dopants and the structural, morphological and electrical characterization followed by the synthesis of metal nanoparticles incorporated PANI samples and the detailed optical characterization in the linear and nonlinear regimes. The second phase of the work comprises the investigations on the prospects of PANI in realizing polymer based rechargeable lithium ion cells with the inherent structural flexibility of polymer systems and environmental safety and stability. Secondary battery systems have become an inevitable part of daily life. They can be found in most of the portable electronic gadgets and recently they have started powering automobiles, although the power generated is low. The efficient storage of electrical energy generated from solar cells is achieved by using suitable secondary battery systems. The development of rechargeable battery systems having excellent charge storage capacity, cyclability, environmental friendliness and flexibility has yet to be realized in practice. Rechargeable Li-ion cells employing cathode active materials like LiCoO2, LiMn2O4, LiFePO4 have got remarkable charge storage capacity with least charge leakage when not in use. However, material toxicity, chance of cell explosion and lack of effective cell recycling mechanism pose significant risk factors which are to be addressed seriously. These cells also lack flexibility in their design due to the structural characteristics of the electrode materials. Global research is directed towards identifying new class of electrode materials with less risk factors and better structural stability and flexibility. Polymer based electrode materials with inherent flexibility, stability and eco-friendliness can be a suitable choice. One of the prime drawbacks of polymer based cathode materials is the low electronic conductivity. Hence the real task with this class of materials is to get better electronic conductivity with good electrical storage capability. Electronic conductivity can be enhanced by using proper dopants. In the designing of rechargeable Li-ion cells with polymer based cathode active materials, the key issue is to identify the optimum lithiation of the polymer cathode which can ensure the highest electronic conductivity and specific charge capacity possible The development of conducting polymer based rechargeable Li-ion cells with high specific capacity and excellent cycling characteristics is a highly competitive area among research and development groups, worldwide. Polymer based rechargeable batteries are specifically attractive due to the environmentally benign nature and the possible constructional flexibility they offer. Among polymers having electrical transport properties suitable for rechargeable battery applications, polyaniline is the most favoured one due to its tunable electrical conducting properties and the availability of cost effective precursor materials for its synthesis. The performance of a battery depends significantly on the characteristics of its integral parts, the cathode, anode and the electrolyte, which in turn depend on the materials used. Many research groups are involved in developing new electrode and electrolyte materials to enhance the overall performance efficiency of the battery. Currently explored electrolytes for Li ion battery applications are in liquid or gel form, which makes well-defined sealing essential. The use of solid electrolytes eliminates the need for containment of liquid electrolytes, which will certainly simplify the cell design and improve the safety and durability. The other advantages of polymer electrolytes include dimensional stability, safety and the ability to prevent lithium dendrite formation. One of the ultimate aims of the present work is to realize all solid state, flexible and environment friendly Li-ion cells with high specific capacity and excellent cycling stability. Part of the present work is hence focused on identifying good polymer based solid electrolytes essential for realizing all solid state polymer based Li ion cells.The present work is an attempt to study the versatile roles of polyaniline in two different fields of technological applications like nonlinear optics and energy storage. Conducting form of doped PANI films with good extent of crystallinity have been realized using a level surface assisted casting method in addition to the generally employed technique of spin coating. Metal nanoparticles embedded PANI offers a rich source for nonlinear optical studies and hence gold and silver nanoparticles have been used for making the nanocomposites in bulk and thin film forms. These PANI nanocomposites are found to exhibit quite dominant third order optical non-linearity. The highlight of these studies is the observation of the interesting phenomenon of the switching between saturable absorption (SA) and reverse saturable absorption (RSA) in the films of Ag/PANI and Au/PANI nanocomposites, which offers prospects of applications in optical switching. The investigations on the energy storage prospects of PANI were carried out on Li enriched PANI which was used as the cathode active material for assembling rechargeable Li-ion cells. For Li enrichment or Li doping of PANI, n-Butyllithium (n-BuLi) in hexanes was used. The Li doping as well as the Li-ion cell assembling were carried out in an argon filled glove box. Coin cells were assembled with Li doped PANI with different doping concentrations, as the cathode, LiPF6 as the electrolyte and Li metal as the anode. These coin cells are found to show reasonably good specific capacity around 22mAh/g and excellent cycling stability and coulombic efficiency around 99%. To improve the specific capacity, composites of Li doped PANI with inorganic cathode active materials like LiFePO4 and LiMn2O4 were synthesized and coin cells were assembled as mentioned earlier to assess the electrochemical capability. The cells assembled using the composite cathodes are found to show significant enhancement in specific capacity to around 40mAh/g. One of the other interesting observations is the complete blocking of the adverse effects of Jahn-Teller distortion, when the composite cathode, PANI-LiMn2O4 is used for assembling the Li-ion cells. This distortion is generally observed, near room temperature, when LiMn2O4 is used as the cathode, which significantly reduces the cycling stability of the cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a new, power-free and flexible detection system named MCFphone for portable colorimetric and fluorescence quantitative sandwich immunoassay detection of prostate specific antigen (PSA). The MCFphone is composed by a smartphone integrated with a magnifying lens, a simple light source and a miniaturised immunoassay platform, the Microcapillary Film (MCF). The excellent transparency and flat geometry of fluoropolymer MCF allowed quantitation of PSA in the range 0.9 to 60 ng/ml with < 7 % precision in 13 minutes using enzymatic amplification and a chromogenic substrate. The lower limit of detection was further improved from 0.4 to 0.08 ng/ml in whole blood samples with the use of a fluorescence substrate. The MCFphone has shown capable of performing rapid (13 to 22 minutes total assay time) colorimetric quantitative and highly sensitive fluorescence tests with good %Recovery, which represents a major step in the integration of a new generation of inexpensive and portable microfluidic devices with commercial immunoassay reagents and off-the-shelf smartphone technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

If it is the case that artists and art explore organization of the brain (Zeki & Lamb, 1994), then the investigation of response to artistic performance holds promise as a window to perceptual and cognitive processes. The portable Audience Response Facility (pARF) is an instrument for recording real‐time audience response (Stevens et al. 2009). Twenty, handheld, Personal Digital Assistants (PDAs) collect responses on customizable skin interfaces. The pARF server transmits the customizable options, synchronizes devices and collects data for export. In this paper we report ratings of the usability of the pARF that were collected after 37 participants had used it to continuously rate engagement along a single dimension while a female dance artist gave two performances of a short solo contemporary dance work. The motion of the dancer was also captured as she performed the piece but only usability rating data are reported here. Ratings indicate that the cognitive load imposed by continuously rating engagement while watching a dance performance was manageable and the pARF was easy to use. An extended familiarization phase may further reduce dual task demand.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The filling of printed forms has always been an issue for the visually impaired. Though optical character recognition technology has helped many blind people to ‘read’ the world, there is not a single device that allows them to fill out a paper-based form without a human assistant. The task of filling forms is however an essential part of their daily lives, for example, for access to social security or benefits. This paper describes a solution that allows a blind person to complete paper-based forms, pervasively and independently, using only off-the-shelf equipment including a Smartphone, a clipboard with sliding ruler, and a ballpoint pen. A dynamic color fiduciary (point of reference) marker is designed so that it can be moved by the user to any part of the form such that all regions can be “visited”. This dynamic color fiduciary marker is robust to camera focus and partial occlusion, allowing flexibility in handling the Smartphone with embedded camera. Feedback is given to the blind user via both voice and tone to facilitate efficient guidance in filling out the form. Experimental results have shown that this prototype can help visually impaired people to fill out a form independently.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eye-tracking equipment is now affordable and portable, making it a practical instrument for consumer research. Engineered to best analyze gaze on a plane (e.g., a retail shelf), both portable eye-tracking glasses and computer monitor–mounted hardware can play key roles in analyzing merchandise displays to better understand what consumers view. Researchers and practitioners can use that information to improve the sales efficacy of displays. Eye-tracking hardware was nearly exclusively used to investigate the reading process but can now be used for a broader range of study, namely in retail settings. This article presents an approach to using glasses eye tracker (GET) and light eye tracker (LET) eye-tracking hardware for applied consumer research in the field. We outline equipment use, study construction, data extraction as well as benefits and limitations of the technology collected from several pilot studies.